Bacharach PCA3 Specifications

Complies with:
U.S. EPA Test Methods,
CTM-030, & State and
Local Protocols
including SCAQMD
P
t
s
i
u
b
m
o
C
e
l
b
a
t
r
o
A
C
P
PCA®3
Features & Benets:
• Full color, multilingual graphic display with backlighting, zoom display and dimming mode
• Sturdy metal gas and draft connectors
• Measures up to 4 gases simultaneously
• Exclusive B-Smart reduces downtime and calibration costs
• Ten different fuels – ability to load custom fuels
• Automatic CO over-range protection
• Measures and displays ue gas oxygen, carbon monoxide, stack temperature, combustion air temperature, draft and differential pressure
• Loss and efciency are calculated from standard heat-loss calculations or using the Siegert formula for Europe
®
o
n
A
®
3
eld-replaceable sensors
n
a
l
y
z
e
r
• NO
Bacharach’s all new PCA®3 is the denitive combustion and emissions analyzer that enables fast and accurate
measurement for on-demand or semi-continuous sampling of light industrial, institutional, commercial and residential furnaces, boilers and appliances. Exclusive B-Smart calibration as simple as pushing a button.
®
plug-and-play sensor technology makes
reading from NO+NO2 or calculated from
x
NO only
The Bacharach PCA®3 is the perfect tool for service technicians and boiler contractors who need to ensure safe
operating conditions, determine combustion efciency and perform emissions testing. This lightweight handheld combustion and emissions analyzer directly measures and displays Flue Gas Oxygen (O Stack Temperature, Draft, Differential Pressure, Combustion Air Temperature and optionally measures and displays Nitric Oxide (NO), Nitrogen Dioxide (NO displays Combustion Efciency (EFF), Excess Air (EA), Carbon Dioxide (CO Plus, the PCA from a choice of up to 6 eld-upgradable electrochemical sensors. With its large, vibrant color display, reading combustion and emissions test results in any work environment has never been easier!
1-800-736-4666 | 724-334-5000 | www.MyBacharach.com | help@MyBacharach.com
®
3 performs combustion calculations for ten different fuels and can measure 4 gases simultaneously
) and Sulfur Dioxide (SO2). The PCA®3 simultaneously calculates and
2
), NOx and Oxygen reference values.
2
), Carbon Monoxide (CO),
2
PCA®3 Specifications
North American Version European Version
Measurement Ranges:
Primary/Ambient Air Temperature Stack Temperature -4 Oxygen 0.1 to 20.9% 0.1 to 20.9% Carbon Monoxide 0 to 4,000 ppm 0 to 4,000 ppm
Compensated)
(H
2
Carbon Monoxide (High Range) 4,001 to 20,000 ppm 4,001 to 20,000 ppm Nitric Oxide 0 to 3,000 ppm 0 to 3,000 ppm Nitrogen Dioxide 0 to 500 ppm 0 to 500 ppm Sulfur Dioxide 0 to 5,000 ppm 0 to 5,000 ppm Pressure +/- 72 inwc +/- 179 mB
Calculated Ranges:
Combustion Efciency 0.1 to 100.0 % EFF 0.1 to 100.0%
ETA 0.1 to 112.0% (Fuel Dependent)
Stack Loss ---- qA 0.1 to 100.0% Excess Air 1.0 to 250% Lambda 1 to 9.55% Carbon Dioxide 0 to Fuel Dependent Maximum 0 to Fuel Dependent Maximum
(NO + NO2) 0 to 3500 ppm 0 to 3500 ppm
NO
x
(Calculated from NO) 0 to 3500 ppm 0 to 3500 ppm
NO
x
Referenced to %O2 0 to 9999 ppm 0 to 9999 ppm
NO
x
CO Referenced to % O NO Referenced to % O
Referenced to % O2 0 to 9999 ppm 0 to 9999 ppm
NO
2
Referenced to % O2 0 to 9999 ppm 0 to 9999 ppm
SO
2
---- 0.0001 to Fuel Dependent
CO/CO
2
Maximum Selectable Fuels: Natural Gas Natural Gas Oil #2 KOKS Oil #4 LEG Oil #6 Propane Propane Oil #2 Coal Oil #6 Wood Coal Kerosene BioFuel Bagasse LPG Digester Gas Butane
Accuracy:
Oxygen +/- 0.3% O Stack Temperature +/- 4
+/- 6 +/- 8
Primary/Ambient Air Temperature Pressure/Draft +/- 0.02 inwc between -1 to 1 inwc +/- 0.05 mB between -2.49 to 2.49 mB
CO +/- 5% of reading or 10 ppm in the range of 0 to 2000 ppm CO
+ 10% of reading in the range of 2001 to 4000 ppm NO +/- 5% of reading or 5 ppm whichever is greater in the range of 0 to 2000 ppm NO
+/- 5% of reading or 5 ppm whichever is greater
NO
2
+/- 5% of reading or 10 ppm whichever is greater in the range of 0 to 2000 ppm SO
SO
2
Dimensions: 9” x 3” x 2 ½” 22.9 cm x 7.6 cm x 6.3 cm Weight: 1.4 lbs (w/batteries) 0.6 kg (w/batteries) Body Materials: Durable ABS Housing/Rugged Rubberized Over-molding and Protective Boot w/Magnet User Interface: Full Color Graphic Display (320 x 240 pixels), Optional Infrared Printer Operating Temperature Range: 32 Operating Humidity Range: 15-90% RH Non-condensing Power: 4 AA Alkaline Batteries
Optional Universal AC Adapter (100 to 240 Volts at 47 to 63 Hz)
Battery Life: Minimum of 10 Hours of Operation Approvals: CE Mark • EN 55011, EN 50270, CE Mark, EN 50379-2
Distributed By:
-4o to 999o F -20o to 537o C
o
to 2192o F -20o to 1200o C
0 to 9999 ppm 0 to 9999 ppm
2
0 to 9999 ppm 0 to 9999 ppm
2
2
(Flue Gas)
o
F between 32o to 255o F +/- 2o C between 0o to 124o C
o
F between 256o to 480o F +/- 3o C between 125o to 249o C
o
+/- 2o F between 32o to 212o F +/- 1o C between 0 o to 100o C
F between 481o to 752o F +/- 4o C between 250o to 400o C
+/- 2% Reading between -10 to 10 inwc +/- 3% Reading between -40 to 40 inwc
o
to 104o F 0o to 40o C
+/- 2% Reading between – 24.9 to 24.9 mB +/- 3% Reading between -100 to 100 mB
2
PCA®3 Kit
PCA®3 Combustion Analyzer, 12” Probe Assembly,
Protective Boot w/Magnet, Fyrite® User Software, USB Cable, Replacement Filter Element (pkg. of 3), 8 ‘AA’ Alkaline Batteries, Hard Carrying Case and
Printer
PCA®3 Basic
PCA®3 Combustion Analyzer, 12” Probe Assembly,
Protective Boot w/Magnet, Fyrite® User Software, USB Cable, Replacement Filter Element (pkg. of 3), 4 ‘AA’ Alkaline Batteries and Hard Carrying Case
PCA®3 Ordering Information
N. AM EU
0024-8440 0024-8460 PCA®3 225 (O2, CO) 0024-8441 0024-8461 PCA 0024-8442 0024-8462 PCA 0024-8443 0024-8463 PCA 0024-8444 0024-8464 PCA 0024-8445 0024-8465 PCA 0024-8446 0024-8466 PCA 0024-8447 0024-8467 PCA 0024-8448 0024-8468 PCA 0024-8449 0024-8469 PCA 0024-8450 0024-8470 PCA 0024-8451 0024-8471 PCA 0024-8452 0024-8472 PCA 0024-8453 0024-8473 PCA
PCA®3 Replacement Parts & Accessories
0024-1541 B-Smart® CO (H2 Compensated) Sensor 0024-1542 B-Smart 0024-1545 B-Smart 0024-1544 B-Smart 0024-1543 B-Smart 0024-0788 Replacement O 0024-0789 Replacement CO Sensor 0024-0881 Replacement NO Sensor 0024-0997 Replacement CO (high range) 0024-0998 Replacement SO 0024-1027 Replacement NO 0024-1400 IrDA Printer w/Disposable Batteries (comes with Reporting Pkg. Kit) 0024-1310 Printer Paper (5 rolls) 0006-8733 Printer Paper (1 roll) 0024-1254 Universal AC Power Adapter (110-240V) 0007-1644 Replacement Filter Element (pkg. of 3) 0024-7224 Compact Sample Conditioner* 0024-3004 Replacement Probe Assembly (North American) 0024-3053 Replacement Probe Assembly (European) 0024-1124 20 ft. Hose Extension with Sample, Draft and Thermocouple Lines 0024-1470 Fyrite 0021-7006 Tru Spot Smoke Tester
All instruments can be upgraded to include combinations of CO (high), NO, NO2
2
and SO
*The Compact Sample Conditioner is recommended when measuring NO
2
to ensure the highest degree of measurement accuracy.
SO
®
User Software
®
3 235 (O2, CO, NO)
®
3 245 (O2, CO, CO high)
®
3 255 (O2, CO, SO2)
®
3 265 (O2, CO, NO, NO2)
®
3 275 (O2, CO, NO, SO2)
®
3 285 (O2, CO, NO, CO high)
®
3 225 Kit (O2, CO, printer)
®
3 235 Kit (O2, CO, NO, printer)
®
3 245 Kit (O2, CO, CO high, printer)
®
3 255 Kit (O2, CO, SO2, printer)
®
3 265 Kit (O2, CO, NO, NO2, printer)
®
3 275 Kit (O2, CO, NO, SO2, printer)
®
3 285 Kit (O2, CO, NO, CO high, printer)
®
CO (high range) Sensor
®
NO Sensor
®
NO2 Sensor
®
SO2 Sensor
Sensor
2
Sensor
2
Sensor
2
2
and
Made in the USa
©2012. Bacharach, Inc., all rights reserved. All information is subject to verication.
Bacharach® is a registered trademark of Bacharach, Inc.
September 2012 – Rev. 2 Printed in U.S.A.
Loading...