Axis Q6045-S Installation Manual

AXISQ60-SSeries
ENGLISH
FRANÇAIS
DEUTSCH
ITALIANO
ESPANÕL
ò
ò
¨
¨
¾
¾
AXISQ6042-SPTZDomeNetworkCamera AXISQ6044-SPTZDomeNetworkCamera AXISQ6045-SMkIIPTZDomeNetworkCamera
LegalConsiderations
Videosurveillancecanberegulatedbylawsthatvaryfrom countrytocountry.Checkthelawsinyourlocalregion beforeusingthisproductforsurveillancepurposes.
Thisproductincludesone(1)H.264decoderlicense.To purchasefurtherlicenses,contactyourreseller.
Liability
Everycarehasbeentakeninthepreparationofthis document.PleaseinformyourlocalAxisofceofany inaccuraciesoromissions.AxisCommunicationsABcannot beheldresponsibleforanytechnicalortypographicalerrors andreservestherighttomakechangestotheproductand manualswithoutpriornotice.AxisCommunicationsAB makesnowarrantyofanykindwithregardtothematerial containedwithinthisdocument,including,butnotlimited to,theimpliedwarrantiesofmerchantabilityandtnessfor aparticularpurpose.AxisCommunicationsABshallnot beliablenorresponsibleforincidentalorconsequential damagesinconnectionwiththefurnishing,performance oruseofthismaterial.Thisproductisonlytobeusedfor itsintendedpurpose.
IntellectualPropertyRights
AxisABhasintellectualpropertyrightsrelatingto technologyembodiedintheproductdescribedinthis document.Inparticular,andwithoutlimitation,these intellectualpropertyrightsmayincludeoneormoreof thepatentslistedatwww.axis.com/patent.htmandoneor moreadditionalpatentsorpendingpatentapplicationsin theUSandothercountries.
Thisproductcontainslicensedthird-partysoftware.See themenuitem“About”intheproduct’suserinterfacefor moreinformation.
ThisproductcontainssourcecodecopyrightAppleComputer, Inc.,underthetermsofApplePublicSourceLicense2.0 (seewww.opensource.apple.com/apsl).Thesourcecodeis availablefromhttps://developer.apple.com/bonjour/
EquipmentModications
Thisequipmentmustbeinstalledandusedin strictaccordancewiththeinstructionsgiveninthe userdocumentation.Thisequipmentcontainsno user-serviceablecomponents.Unauthorizedequipment changesormodicationswillinvalidateallapplicable regulatorycerticationsandapprovals.
TrademarkAcknowledgments
AXISCOMMUNICATIONS,AXIS,ETRAX,ARTPECandVAPIX areregisteredtrademarksortrademarkapplicationsofAxis ABinvariousjurisdictions.Allothercompanynamesand productsaretrademarksorregisteredtrademarksoftheir respectivecompanies.
Apple,Boa,Apache,Bonjour,Ethernet,InternetExplorer, Linux,Microsoft,Mozilla,Real,SMPTE,QuickTime,UNIX, Windows,WindowsVistaandWWWareregistered trademarksoftherespectiveholders.Javaandall Java-basedtrademarksandlogosaretrademarksor registeredtrademarksofOracleand/oritsafliates.
TM
UPnP
isacerticationmarkoftheUPnP
Corporation. SD,SDHCandSDXCaretrademarksorregisteredtrademarks
ofSD-3C,LLCintheUnitedStates,othercountriesorboth. Also,miniSD,microSD,miniSDHC,microSDHC,microSDXC arealltrademarksorregisteredtrademarksofSD-3C,LLC intheUnitedStates,othercountriesorboth.
TM
Implementers
RegulatoryInformation
Europe
ThisproductcomplieswiththeapplicableCEmarking
directivesandharmonizedstandards:
ElectromagneticCompatibility(EMC)Directive
2004/108/EC.SeeElectromagneticCompatibility(EMC) onpage2.
LowVoltage(LVD)Directive2006/95/EC.SeeSafety
onpage3.
RestrictionsofHazardousSubstances(RoHS)Directive
201 1/65/EU.SeeDisposalandRecyclingonpage3. Acopyoftheoriginaldeclarationofconformitymaybe obtainedfromAxisCommunicationsAB.SeeContact Informationonpage3.
ElectromagneticCompatibility(EMC)
Thisequipmenthasbeendesignedandtestedtofulll applicablestandardsfor:
Radiofrequencyemissionwheninstalledaccordingto
theinstructionsandusedinitsintendedenvironment.
Immunitytoelectricalandelectromagneticphenomena
wheninstalledaccordingtotheinstructionsandused
initsintendedenvironment.
USA
Thisequipmenthasbeentestedusingashieldednetwork cable(STP)andfoundtocomplywiththelimitsfora ClassAdigitaldevice,pursuanttopart15oftheFCCRules. Theselimitsaredesignedtoprovidereasonableprotection againstharmfulinterferencewhentheequipmentis operatedinacommercialenvironment.Thisequipment generates,uses,andcanradiateradiofrequencyenergy and,ifnotinstalledandusedinaccordancewiththe instructionmanual,maycauseharmfulinterferenceto radiocommunications.Operationofthisequipmentin aresidentialareaislikelytocauseharmfulinterference inwhichcasetheuserwillberequiredtocorrectthe interferenceathisownexpense. Theproductshallbeconnectedusingashieldednetwork cable(STP)thatisproperlygrounded.
Canada
ThisdigitalapparatuscomplieswithCANICES-3(ClassA). Theproductshallbeconnectedusingashieldednetwork cable(STP)thatisproperlygrounded. Cetappareilnumériqueestconformeàlanorme NMBICES-3(classeA).Leproduitdoitêtreconnectéà l'aided'uncâbleréseaublindé(STP)quiestcorrectement misàlaterre.
Europe
ThisdigitalequipmentfulllstherequirementsforRF emissionaccordingtotheClassAlimitofEN55022.The productshallbeconnectedusingashieldednetworkcable (STP)thatisproperlygrounded.Notice!ThisisaClassA product.Inadomesticenvironmentthisproductmaycause RFinterference,inwhichcasetheusermayberequired totakeadequatemeasures.
Thisproductfulllstherequirementsforemissionand immunityaccordingtoEN50121-4andIEC62236-4railway applications.
Thisproductfulllstherequirementsforimmunity accordingtoEN61000-6-1residential,commercialand light-industrialenvironments.
Thisproductfulllstherequirementsforimmunity accordingtoEN61000-6-2industrialenvironments.
Thisproductfulllstherequirementsforimmunity accordingtoEN55024ofceandcommercialenvironments
Australia/NewZealand
ThisdigitalequipmentfulllstherequirementsforRF emissionaccordingtotheClassAlimitofAS/NZSCISPR22. Theproductshallbeconnectedusingashieldednetwork cable(STP)thatisproperlygrounded.Notice!Thisisa ClassAproduct.Inadomesticenvironmentthisproduct maycauseRFinterference,inwhichcasetheusermaybe requiredtotakeadequatemeasures.
Japan
この装置は、クラスA情報技術装置です。この装 置を家庭環境で使用すると電波妨害を引き起こす ことがあります。この場合には使用者が適切な対 策を講ずるよう要求されることがあります。本 製品は、シールドネットワークケーブル(STP)を 使用して接続してください。また適切に接地し てください。
Korea
이기기는업무용(A급)전자파적합기기로서판매 자또는사용자는이점을주의하시기바라며,가 정외의지역에서사용하는것을목적으로합니다. 적절히접지된STP(shieldedtwistedpair)케이블 을사용하여제품을연결하십시오.
Safety
ThisproductcomplieswithIEC/EN/UL60950-1and IEC/EN/UL60950-22,SafetyofInformationTechnology Equipment.Theproductshallbegroundedeitherthrougha shieldednetworkcable(STP)orotherappropriatemethod.
Thepowersupplyusedwiththisproductshallfulllthe requirementsforSafetyExtraLowVoltage(SELV)according toIEC/EN/UL60950-1.
DisposalandRecycling
Whenthisproducthasreachedtheendofitsusefullife, disposeofitaccordingtolocallawsandregulations.For informationaboutyournearestdesignatedcollectionpoint, contactyourlocalauthorityresponsibleforwastedisposal. Inaccordancewithlocallegislation,penaltiesmaybe applicableforincorrectdisposalofthiswaste.
Europe
Tel:+46462721800 Fax:+4646136130
www.axis.com
Support
Shouldyourequireanytechnicalassistance,pleasecontact yourAxisreseller.Ifyourquestionscannotbeanswered immediately,yourresellerwillforwardyourqueriesthrough theappropriatechannelstoensurearapidresponse.Ifyou areconnectedtotheInternet,youcan:
downloaduserdocumentationandsoftwareupdates
ndanswerstoresolvedproblemsintheFAQdatabase.
Searchbyproduct,category,orphrase
reportproblemstoAxissupportstaffbylogginginto
yourprivatesupportarea
chatwithAxissupportstaff(selectedcountriesonly)
visitAxisSupportatwww.axis.com/techsup/
LearnMore!
VisitAxislearningcenterwww.axis.com/academy/for usefultrainings,webinars,tutorialsandguides.
Thissymbolmeansthattheproductshallnotbe disposedoftogetherwithhouseholdorcommercialwaste. Directive2012/19/EUonwasteelectricalandelectronic equipment(WEEE)isapplicableintheEuropeanUnion memberstates.Topreventpotentialharmtohumanhealth andtheenvironment,theproductmustbedisposedofin anapprovedandenvironmentallysaferecyclingprocess. Forinformationaboutyournearestdesignatedcollection point,contactyourlocalauthorityresponsibleforwaste disposal.Businessesshouldcontacttheproductsupplierfor informationabouthowtodisposeofthisproductcorrectly.
Thisproductcomplieswiththerequirementsof Directive2011/65/EUontherestrictionoftheuseof certainhazardoussubstancesinelectricalandelectronic equipment(RoHS).
China
Thisproductcomplieswiththerequirementsofthe legislativeactAdministrationontheControlofPollution CausedbyElectronicInformationProducts(ACPEIP).
ContactInformation
AxisCommunicationsAB Emdalavägen14 22369Lund Sweden
AXISQ60-SSeries
ENGLISH
SafetyInformation
ReadthroughthisInstallationGuidecarefullybeforeinstallingtheproduct.KeeptheInstallation Guideforfuturereference.
HazardLevels
DANGER
WARNING
CAUTION
NO
TICE
NO NO
TICE TICE
Indicatesahazardoussituationwhich,ifnotavoided,willresultin deathorseriousinjury.
Indicatesahazardoussituationwhich,ifnotavoided,couldresult indeathorseriousinjury.
Indicatesahazardoussituationwhich,ifnotavoided,couldresult inminorormoderateinjury.
Indicatesasituationwhich,ifnotavoided,couldresultindamage toproperty.
OtherMessageLevels
ImportantIndicatessignicantinformationwhichisessentialfortheproduct
NoteIndicatesusefulinformationwhichhelpsingettingthemostout
tofunctioncorrectly.
oftheproduct.
5
AXISQ60-SSeries
SafetyInstructions
WARNING
•TheAxisproductshallbeinstalledbyatrainedprofessional.
NO
TICE
NO NO
TICE TICE
•TheAxisproductshallbeusedincompliancewithlocallawsandregulations.
•StoretheAxisproductinadryandventilatedenvironment.
•AvoidexposingtheAxisproducttoshocksorheavypressure.
•Donotinstalltheproductonunstablebrackets,surfacesorwalls.
•UseonlyapplicabletoolswheninstallingtheAxisproduct.Excessiveforcecouldcause damagetotheproduct.
•Donotusechemicals,causticagents,oraerosolcleaners.
•Useacleanclothdampenedwithpurewaterforcleaning.
•Useonlyaccessoriesthatcomplywithtechnicalspecicationoftheproduct.Thesecanbe providedbyAxisorathirdparty.
•UseonlysparepartsprovidedbyorrecommendedbyAxis.
•Donotattempttorepairtheproductbyyourself.ContactAxissupportoryourAxis resellerforservicematters.
Transportation
NO
TICE
NO NO
TICE TICE
•Keeptheprotectivepackaging.WhentransportingtheAxisproduct,theprotective packagingshallbereplacedinitsoriginalposition.
•WhentransportingtheAxisproduct,usetheoriginalpackagingorequivalenttoprevent damagetotheproduct.
Battery
TheAxisproductusesa3.0VBR/CR2032lithiumbatteryasthepowersupplyforitsinternal real-timeclock(RTC).Undernormalconditionsthisbatterywilllastforaminimumofveyears.
LowbatterypoweraffectstheoperationoftheRTC,causingittoresetateverypower-up.When thebatteryneedsreplacing,alogmessagewillappearintheproduct’sserverreport.Formore informationabouttheserverreport,seetheproduct´ssetuppagesorcontactAxissupport.
Thebatteryshouldnotbereplacedunlessrequired,butifthebatterydoesneedreplacing,contact Axissupportatwww.axis.com/techsupforassistance.
6
AXISQ60-SSeries
ENGLISH
WARNING
•Riskofexplosionifthebatteryisincorrectlyreplaced.
•ReplaceonlywithanidenticalbatteryorabatterywhichisrecommendedbyAxis.
•Disposeofusedbatteriesaccordingtolocalregulationsorthebatterymanufacturer's instructions.
DomeCover
NO
TICE
NO NO
TICE TICE
•Becarefulnottoscratch,damageorleavengerprintsonthedomecoverbecausethis coulddecreaseimagequality.Ifpossible,keeptheprotectiveplasticonthedomecover untiltheinstallationiscomplete.
•Donotcleanadomecoverthatlookscleantotheeyeandneverpolishthesurface. Excessivecleaningcoulddamagethesurface.
•Forgeneralcleaningofthedomecoveritisrecommendedtouseanon-abrasive, solvent-freeneutralsoapordetergentmixedwithpurewaterandasoft,cleancloth.Rinse wellwithpurelukewarmwater.Drywithasoft,cleanclothtopreventwaterspotting.
•Neveruseharshdetergentsoralcohols(isopropyl,butyl,propyl)andavoidcleaningthe domecoverindirectsunlightoratelevatedtemperatures.
7
8
AXISQ60-SSeries
ENGLISH
InstallationGuide
ThisInstallationGuideprovidesinstructionsforinstallingAXISQ6042-SPTZDomeNetwork Camera,AXISQ6044-SPTZDomeNetworkCameraorAXISQ6045-SMkIIPTZDomeNetwork Cameraonyournetwork.Forotheraspectsofusingtheproduct,seetheUserManualavailable atwww.axis.com
InstallationSteps
1.Makesurethepackagecontents,toolsandothermaterialsnecessaryfortheinstallation
areinorder.Seepage9.
2.Studythehardwareoverview.Seepage1 1.
3.Studythespecications.Seepage18.
4.Installthehardware.Seepage22.
5.Accesstheproduct.Seepage31.
PackageContents
•AXISQ6042-SPTZDomeNetworkCamera,AXISQ6044-SPTZDomeNetworkCameraor
AXISQ6045-SMkIIPTZDomeNetworkCamera
•AXIST8605MediaConverterSwitch
•Multi-connectorcable(IP66),7m(23ft)
•DINrailclip
•InstallationandManagementSoftwareCD
•Printedmaterials
-InstallationGuide(thisdocument)
-Extraserialnumberlabel(2x)
-AVHSAuthenticationkey
RecommendedTools
NO
TICE
NO NO
TICE TICE
Stainlesssteeliscorrosion-resistant,butextraneousrustcanappearifthematerialis handledincorrectly.Usestainlesstoolstoavoidruststainsorpittingcorrosion.
•TorxscrewdriverT10(lid,cableclampingMediaConverterSwitch)
•TorxscrewdriverT20(domecoverremoval)
•TorxscrewdriverT25(domereplacement)
•Slottedscrewdriver2.5mm(socket,MediaConverterSwitch)
9
AXISQ60-SSeries
•7mmwrench(groundscrewMediaConverterSwitch)
•8mm(5/16”)wrench/socket(Sunshield,PoleBracketT91C67(hoseclamp))
•10mm(3/8”)wrench/socket(BracketadapterAXIST91C61,AXIST94S01D,PoleBracket T91C67)
•Cableshoepliers(groundcableMediaConverterSwitch)
•Diagonalpliers(cables)
•Wirestrippingtool(cableconnecting)
OptionalAccessories
•AXIST91C61WallMount
•AXIST94S01DPendantKit
•AXIST91C67PoleMount
•Sunshield
•Smokeddomecover
•AXIST8008PS12PowerSupply
•AXIST8310VideoSurveillanceControlBoard
•AXIST90BIlluminators
•InstallationDisplay
Forinformationaboutavailableaccessories,seewww.axis.com
10
AXISQ60-SSeries
21 3 4 5 6 7 8
9 10 11
ENGLISH
HardwareOverview
1 2 3 4 5 6 7 8 9 10 11
Mountingholeforsunshield(3x) Pressurereliefvalve Multiconnector Hookforsafetywire Guidehole Inletvalve Mountinghole(3x) Partnumber(P/N)&Serialnumber(S/N) SDcardslot(SDHC) StatusLEDindicator Controlbutton
11
AXISQ60-SSeries
1
3
4
2
5
6
1
DomeCover
Sunshield(SoldSeparately)
1
DomebracketscrewT25(4x)
2
Domecover
3
Rubbergasket
4
Rubbergasket
5
Domering
6
DomeringscrewT20(4x)
1
Screwholes
12
MediaConverterSwitch
1
2
3
4
5
6
7
8
10
9
11
12
13
ENGLISH
AXISQ60-SSeries
1
Powerconnector(DCinput)
2
Powerconnector(DCoutput)
3
Networkconnector(internal)
4
NetworkslotSFP(external)(2x)
5
NetworkconnectorRJ45(external)(2x)
6
CameraLEDindicator
7
NetworkLEDindicator(4x)
8
PowerLEDindicator
9
Groundclip
10
I/Oconnector(internal)
11
I/Oconnector(external)
12
Multi-connectorcable
13
Groundscrew
LEDIndicators
StatusLED
Unlit
Indication
Connectionandnormaloperation.
13
AXISQ60-SSeries
GreenShowssteadygreenfor10secondsfornormaloperationafter
Amber
Amber/RedFlashesamber/redifnetworkconnectionisunavailableorlost. RedFlashesredforrmwareupgradefailure.
startupcompleted. Steadyduringstartup.Flashesduringrmwareupgrade.
MediaConverterSwitchLEDIndicators
LED
Power
Network(4x)
CameraGreen
Color
Unlit
GreenDCpowerconnected. Amber10Mbitconnection.Flashesduringactivity. Green
Indication
DCpowerunconnectedorcurrentprotectionengaged(power overload)
100/1000Mbitconnection.Flashesduringactivity. 100Mbitconnection.Flashesduringactivity.
ConnectorsandButtons
Forspecicationsandoperatingconditions,seepage18.
NetworkConnector
NO
TICE
NO NO
TICE TICE
Theproductshallbeconnectedusingashieldednetworkcable(STP).Allcablesconnecting theproducttothenetworkshallbeintendedfortheirspecicuse.Makesurethatthe networkdevicesareinstalledinaccordancewiththemanufacturer’sinstructions.For informationaboutregulatoryrequirements,seeElectromagneticCompatibility(EMC)on page2.
Multi-connector
Terminalconnectorforconnectingthesuppliedmediaconverterswitch,whichprovidesthe followingsignals:
•DCPower
•Network(Ethernet10/100Base-T)
•Input/Output(I/O)
Thesuppliedmulti-connectorcableisrequiredinordertomaintaintheproduct’sNEMA/IPrating. Formoreinformation,seeMulti-ConnectorCableonpage15.
14
AXISQ60-SSeries
ENGLISH
SDCardSlot
SupportsSDcardswithupto64GBofstorage.Forbestrecordingperformance,useanSDHC orSDXCcardwithspeedclass10.
ControlButton
Forlocationofthecontrolbutton,seeHardwareOverviewonpage11.
Thecontrolbuttonisusedfor:
•Resettingtheproducttofactorydefaultsettings.Seepage31.
•ConnectingtoanAXISVideoHostingSystemserviceorAXISInternetDynamicDNS Service.Formoreinformationabouttheseservices,seetheUserManual.
Multi-ConnectorCable
Note
Thesuppliedmulti-connectorcableisrequiredinordertomaintainthecamera’sNEMA/IP rating.
Themulti-connectorcableisconnectedtothecamera’smulti-connector,seeHardwareOverview onpage11.
Thewiresareconnectedtothesuppliedmediaconverterswitch,seeMediaConverterSwitch onpage13.
Thecableprovidesthefollowingsignals:
•DCpowertocamera
•Network(Ethernet10/100Base-T)
•Input/Output(I/O)
15
AXISQ60-SSeries
1
2
3
4
5
6
7
8
9
10
12 11
1 8
2 7
9
3 6
4 5
Multi-connectorcableoverview
1
Powerwire(red)
2
DigitalI/Owire(blue)
3
Ethernetwire(green/white)
4
Ethernetwire(green)
5
Ethernetwire(orange/white)
6
Ethernetwire(orange)
7
DigitalI/Owire(yellow)
8
Groundwire(black)
9
Powerwire(red)
10
Ethernetwirefoilshield(2x)
11
Outerfoilshield
12
Braidedshieldcoil
FunctionPin–wireNotes
Congurable (Inputor Output)
RX+
2–blue 7–yellow
3–green/white
Digitalinput–Connecttopin 8toactivate,orleaveoating (unconnected)todeactivate.
Digitaloutput–Connectedto pin1whenactivated,oating (unconnected)whendeactivated.If usedwithaninductiveload,e.g.a relay,adiodemustbeconnectedin parallelwiththeload,forprotection againstvoltagetransients.
Ethernet–receiving
16
Specications
0tomax30VDC
0tomax30VDC, opendrain, 100mA
AXISQ60-SSeries
ENGLISH
RX­TX+
TX-
0VDC(-)
DCoutput (12V)
4–green
5–orange/white 6–orange
8–black
1,9–redUsedtopowercamera
Ethernet–receiving Ethernet–transmitting
Ethernet–transmitting
MediaConverterSwitchConnectors
Forspecications,seepage18.
NO
TICE
NO NO
TICE TICE
Theproductshallbeconnectedusingashieldednetworkcable(STP).Allcablesconnecting theproducttothenetworkshallbeintendedfortheirspecicuse.Makesurethatthe networkdevicesareinstalledinaccordancewiththemanufacturer’sinstructions.For informationaboutregulatoryrequirements,seeElectromagneticCompatibility(EMC)on page2.
Important
Themediaconverterswitchdoesnotsupporthotswapping.Disconnectpowerfromthe switchbeforeswappingcameras.Anattempttohotswapcouldcausetheswitchtofreeze, inwhichcaseitmustberestarted.
Powerconnector(DCinput)-2-pinterminalblockforpowerinput.
0VDC
12–13.2VDC
Powerconnector(DCoutput)-Two2-pinterminalblockforpoweroutput(pin4isnotused).
NetworkconnectorRJ45(external)-TwoRJ45connectors(10/100Base-T)fornetwork
connectivity.
NetworkslotSFP(external)-TwoSFPslots(100Base-FX/1000Base-X)fornetworkconnectivity.
EachRJ45andSFPporthasitsowndipswitch.Thedipswitchescontrolhowtheportforwards data.Formoreinformation,seetheUserManual.
DipswitchpositionDescriptionofuse
Default(middle)
BWhenconnectingtothenetwork,directlyorthrougha
routerornetworkswitch.
17
AXISQ60-SSeries
LeftAWhenconnectingtoacameraoradevicethatisnot
Right
Networkconnector(internal)-Two2-pinEthernetterminalblocks.
I/Oconnector(external)-6-pincongurableI/Oterminalblock,whichisconnectedtothe
camerathroughthemulti-connectorcable.Usewithexternaldevicesincombinationwith,for example,tamperingalarms,motiondetection,eventtriggering,timelapserecordingandalarm notications.Inadditiontothe0VDCreferencepointandpower(DCoutput),theI/Oconnector providestheinterfaceto:
Digitaloutput–ForconnectingexternaldevicessuchasrelaysandLEDs.
ConnecteddevicescanbeactivatedbytheVAPIX®ApplicationProgramming Interface,outputbuttonsontheLiveViewpageorbyanActionRule.Theoutput willshowasactive(shownunderSystemOptions>Port&Devices>Port Status)ifthealarmdeviceisactivated.
Digitalinput–Analarminputforconnectingdevicesthatcantogglebetween
anopenandclosedcircuit,forexample:PIRs,door/windowcontacts,glass breakdetectors,etc.Whenasignalisreceivedthestatechangesandtheinput becomesactive(shownunderSystemOptions>Port&Devices>PortStatus).
I/Oconnector(internal)-2–pinI/Oterminalblock.
C
intendedforviewingdata. Whenconnectingtoanothermediaconverterswitch.
Specications
OperatingConditions
TheAxisproductisintendedforoutdooruse.
Product
AXISQ6042-S AXISQ6044-S AXISQ6045-SMkII
Classication
IEC60721-4-3 Class3K3 IEC/EN60529IP66 ISO20653IP6K9K
StorageConditions
TheAxisproductisintendedforoutdooruse.
TemperatureHumidity
-30°Cto50°C (-22°Fto122°F)
18
10–100%RH(con­densing)
AXISQ60-SSeries
1 2 3
70 W
65 W
60 W
ENGLISH
ProductTemperature
AXISQ6042-S AXISQ6044-S AXISQ6045-SMkII
ElectricalSpecication
NO
TICE
NO NO
TICE TICE
ForconrmedcompliancewiththerequirementsforSafetyExtraLowVoltage(SELV)and LimitedPowerSource(LPS),usethepowersupply(soldseparately)recommendedbyAxis. Forinformationaboutcompatiblepoweraccessories,seewww.axis.com
ProductFunctionDescription
AXISQ6042-S AXISQ6044-S AXISQ6045-SMkII
Mediaconverterswitch
-40°Cto60°C (-40°Fto140°F)
Inputpower
Inputvoltage Inputpower
Availableoutputpower
Nominaloutputvoltage
12VDC,max60W
12.0–13.2VDC
70W(min)
65W(min)
12.5VDC
1
Mediaconverterswitch
2
Multi-connectorcable
3
Networkcamera
19
AXISQ60-SSeries
- +
21
21 43 65
Connectors
SDCardSlot
SupportsSDcardswithupto64GBofstorage.Forbestrecordingperformance,useanSDHC orSDXCcardwithspeedclass10.
MediaConverterSwitchConnectors
ExternalConnectors
GroundScrewGroundscrewforconnectingthemedia
Powerconnector
2-pinterminalblockforpowerinput.
FunctionPinNotes
0VDC(-) 12VDC
I/Oterminalconnector
6-pinterminalblocksfor:
•DigitalInput/Output
•Power(DCoutput)
•0VDC(-)
FunctionPinNotes
0VDC(-) DCoutput
1
2
1,4,6
2
Powerinfrompower supply(soldseparately)
Powerout
converterswitchtoearthground.Make surethatbothendsofthegrounding wireareincontactwiththeirrespective groundingsurfaces.
Specications
0VDC DCinput
12.0-13.2VDC, min75W
Specications
0VDC
12VDC,50mA
20
AXISQ60-SSeries
+ +
21 43
-
ENGLISH
3
I/O1(InputorOutput)
5
I/O2(InputorOutput)
CameraConnectors
Powerconnector
Two2-pinterminalblocksforpoweroutput(pin4 isnotused).
FunctionPinNotes
DC output
12VDC
0VDC(-)
N/a
1,2
3
4
Digitalinput
Digitaloutput(transistor– opencollector)
Digitalinput
Digitaloutput(transistor– opencollector)
Powerouttocamera
N/a
0tomax30VDC Congurable 0tomax30VDC,
opendrain,100mA
0tomax30VDC Congurable 0tomax30VDC,
opendrain,100mA
Specications
12.0-13.2VDC, min70W
0VDC
Networkconnector
Two2-pinEthernetterminalblocks.
I/Oterminalconnector
2-pinterminalblock.
21
AXISQ60-SSeries
InstalltheHardware
NO
TICE
NO NO
TICE TICE
•Duetolocalregulationsortheenvironmentalandelectricalconditionsinwhichthe productistobeused,ashieldednetworkcable(STP)maybeappropriateorrequired. Allcablesconnectingtheproducttothenetworkandthatareroutedoutdoorsorin demandingelectricalenvironmentsshallbeintendedfortheirspecicuse.Makesurethat thenetworkdevicesareinstalledinaccordancewiththemanufacturer’sinstructions.For informationaboutregulatoryrequirements,seeRegulatoryInformationonpage2.
•Mounttheproductwiththedomecoverfacingdownward.
•Becarefulnottoscratch,damageorleavengerprintsonthedomecoverbecausethis coulddecreaseimagequality.Ifpossible,keeptheprotectiveplasticonthedomecover untiltheinstallationiscomplete.
TheAxisproductcanbeinstalledwiththecablesroutedthroughoralongthewallorroof.
Readalltheinstructionsbeforeinstallingtheproduct.Someinstallationstepswouldbenetfrom beingcompletedtogetherbecausetheyrequireremovalofthedomecover.
Ahardwareinstallationcanincludethefollowing:
•Theproductissuppliedwithacleardomecover(premounted).Asmokeddomecoveris
availableasanaccessory.Toreplacethedomecover,seepage22.
•AstandardorhighcapacitySDcard(notincluded)canbeusedtostorerecordingslocally
intheproduct.ToinstallanSDcard,seepage23.
•ToinstalltheproductusingaT91C61WallMount(soldseparately),seepage29.
AttachtheSunshield
Attachingthesunshieldisoptional.Thesunshieldhelpskeepthetemperatureinsidethecamera down.
1.Removethescrewplugsfromthecameraunit.
2.Placethesunshieldonthecameraunit.
3.Securethesunshieldusingthesuppliedscrews.
ReplacetheDomeCover
Replacingthedomecoverisonlynecessaryifyouwanttouseasmokeddomecoverorifthe domecoverisscratchedordamaged.Smokeddomecoversandsparecleardomecoverscanbe purchasedfromyourAxisreseller.
UsetheInstallationGuidedeliveredwiththedomecover.
22
AXISQ60-SSeries
ENGLISH
InstallanSDCard
ItisoptionaltoinstallanSDcard(notincluded),whichcanbeusedforlocalrecordingwith removablestorage.
1.Loosenthedomeringscrewsandremovethedomecover.
2.InsertanSDcard(notincluded)intotheSDcardslot.
3.Attachthedomecovertothetopcoverandtightenthescrews(torque3.2Nm).
NO
TICE
NO NO
TICE TICE
Topreventcorruptionofrecordings,theSDcardshouldbeunmountedbeforeitisejected. Tounmount,gotoSetup>SystemOptions>Storage>SDCardandclickUnmount.
PressurizetheCamera(Recommended)
ThecamerahousingcanbelledwithNitrogengastopreventcondensation.
Thellingprocessisrepeatedthreetimes,releasingthepressurebetweenllings,tomakesurethat allairandhumidityispurgedfromthehousing.
Note
Thecamerahousinghasanpressurereliefvalvethatlimitsthellingpressureto0.5bar (7psi).Duringnormalusethepressureinsidethecamerahousingmaydropbelowthat pressure.Forfullprotectionmakesurethatthepressureisabove0.2bar(3psi).
1.Settheregulatorgaugeonthegascylinderto0.5bar(7psi).
2.Removethecapsfromtheinletvalveandthepressurereliefvalve.
3.Placethechuckontheinletvalveandpressdowntollthecamerawithnitrogen.
4.Whenthepressureinsidethecamerahousingreaches0.5bar(7psi)thepressurerelief valvewillopen.Placeyourhandoverthepressurereliefvalvetoverifythatthegas isowingout.
5.Keepthegasowingthroughthecamerahousingforoneminutebeforeremovingthe chuckfromtheinletvalve.
6.Liftthepressurereliefvalvetolettheoverpressureoutofthecameraunit.
7.Repeatthellingprocessatotalof3times,leavingthethecamerapressurizedthe lasttime.
8.Putthecapsbackontheinletvalveandthepressurereliefvalve.
InstallthePowerSupplyandtheMediaConverterSwitch
Thesuppliedmediaconverterswitchenablesthemulti-connectorcabletosendpowerfromthe powersupply(soldseparately)andtosendandreceivedatatoandfromexternalalarmdevices andthenetwork.
23
AXISQ60-SSeries
1
2
3
NO
TICE
NO NO
TICE TICE
•Makesuretheconnectionstothemainssupplyandconduitshavebeeninstalledbya trainedprofessional,accordingtothemanufacturer’sinstructionsandincompliance withlocalregulations.
•Thepowersupply(soldseparately)andthemediaconverterswitchshallbeinstalledinan environmentprotectedagainstdustandwater,forexampleindoorsorinanappropriate cabinet.
•Duetolocalregulationsortheenvironmentalandelectricalconditionsinwhichthe productistobeused,ashieldednetworkcable(STP)maybeappropriateorrequired. Allcablesconnectingtheproducttothenetworkandthatareroutedoutdoorsorin demandingelectricalenvironmentsshallbeintendedfortheirspecicuse.Makesurethat thenetworkdevicesareinstalledinaccordancewiththemanufacturer’sinstructions.For informationaboutregulatoryrequirements,seeRegulatoryInformationonpage2.
Important
Axiscanonlyguaranteefullfunctionalitywiththesuppliedmediaconverterswitch.No otherdevicesaresupported.
1.Makesurethemainssupplyisswitchedoff.
2.Mountthepowersupplyandthemediaconverterswitchonthewallor,ifapplicable,
attachthemtoaDINrailinthecabinet.Ifdrillingisrequired,makesuretousedrillbits, screws,andplugsthatareappropriateforthematerial.
3.Loosenthescrewsandremovethecoverfromthemediaconverterswitch.
1 2 3
Screw(2x) Cover Mediaconverterswitch
24
AXISQ60-SSeries
1 22
34
ENGLISH
4.Stripoff40mm(1.57in)ofthemulti-connectorcablejacket.
5.Leavethebraidedshieldintact,butcutoff30mm(1.18in)oftheouterfoilshield.
6.Foldbacktheleftoverouterfoilshieldandtwistthebraidedshieldintoacoil.
7.Cutoffabout7–8mm(0.27–0.32in)oftheEthernetwirefoilshields.
8.Stripoffabout4–5mm(0.16–0.20in)ofthepowerwirejackets.
1
Multi-connectorcablejacket
2
Outerfoilshield
3
Braidedshield
4
Ethernetwirefoilshield(2x)
9.ConnectthenetworkandI/OwirestotheinternalnetworkandI/Oconnectors.Open thelid,insertthewiresandclose.
10.Connectthegroundandpowerwirestothepowerconnector(DCoutput).
25
AXISQ60-SSeries
1
8
9
3
4
5
6
2
7
10
11
12
13
16
14
15
17
18
1
Powerwire(red)
2
DigitalI/Owire(blue)
3
Ethernetwire(green/white)
4
Ethernetwire(green)
5
Ethernetwire(orange/white)
6
Ethernetwire(orange)
7
DigitalI/Owire(yellow)
8
Groundwire(black)
9
Powerwire(red)
10
Powerconnector(DCoutput)
11
Ethernetconnector(internal)
12
Ethernetconnector(internal)
13
I/Oconnector(internal)
14
Groundclip
15
Braidedshieldcoil
16
Outerfoilshield
17
Ethernetwireshield(2x)
18
Clamp
26
AXISQ60-SSeries
1
2
8
3
4
5
6
7
ENGLISH
11.Makesuretheclampisinplace,insertthebraidedshieldcoilintothegroundclipand tightenthescrews.
NO
TICE
NO NO
TICE TICE
•Theshieldsandtheclampsurfacesshallbeinfullcontactwitheachothersothatthe
multi-connectorcableisgrounded.
•Makesurethatthemulti-connectorcablejacketisrmlysecuredbytheclamp.
•Makesureallsurfacesandcontactsarecleanandfreefromscrapshieldmaterial.
12.Connectthenetworkcablestotheexternalnetworkconnectors(RJ45,SFP)asrequired.
Note
AnSFPmodule(notincluded)hastobeusedwhenconnectinganopticalbercable.
1
Powercable(DCinput)
2
Powerconnector(DCinput)
3
NetworkconnectorSFP(external)(2x)
4
NetworkconnectorRJ45(external)(2x)
5
I/Oconnector(external)
6
Multi-connectorcableIP66
27
AXISQ60-SSeries
1
7
Groundwire
8
Groundscrew
13.Ifapplicable,connectanI/OdevicetotheexternalI/Oconnector.
14.Connectthepowercable(DCinput)tothepowerconnector(DCinput)viatheterminal blockplug.
15.Attachthegroundwiretothegroundscrew(position8intheillustration).
16.Ifconnectingseveralmediaconverterswitchesinadaisychain,setthedipswitchof eachoutgoingnetworkconnectorportthatconnectstoanothermediaconverterswitch topositionC.
Leavethedipswitchinitsdefaultposition(positionB)whenconnectingtheportdirectly tothenetwork.Formoreinformation,seeMediaConverterSwitchConnectorsonpage 17andtheUserManual.
Important
Ifthesystemisnotdened,usethedefaultdipswitchsetting(positionB).
1
Dipswitch(4x)
17.Attachthecovertothemediaconverterswitch.
18.Switchonthemainssupply.
19.MakesuretheLEDindicatorsonthemediaconverterswitchindicatethecorrect conditions.Formoreinformation,seeMediaConverterSwitchLEDIndicatorsonpage14.
28
AXISQ60-SSeries
1
2
3
ENGLISH
1
PowerLEDindicator
2
NetworkLEDindicator(4x)ETH1/2/3/4
3
CameraLEDindicator
InstalltheNetworkCamera
NO
TICE
NO NO
TICE TICE
TocomplywiththeIP66-rateddesignofthecameraandmaintaintheIP66protection,the suppliedmulti-connectorcableshallbeused.
1.Installtheselectedbracket(soldseparately)accordingtotheinstructionssuppliedwith thebracket.Ifdrillingisrequired,makesuretousedrillbits,screws,andplugsthatare appropriateforthematerial.Seewww.axis.comforinformationonavailablemounting accessories.
2.Routethemulti-connectorcablethroughtheholesinthemountingbracket.
3.Securethecamerausingthesuppliedsafetywire.
29
AXISQ60-SSeries
1
Mountingexample(wallbracketsoldseparately)
1
Safetywire
4.Removetheprotectioncapcoveringthemulti-connectoronthecamera.
5.Connectthemulti-connectorcabletotheconnectoronthecamera.Usethealignment indicatorstondthecorrectposition.
NO
TICE
NO NO
TICE TICE
Becarefulnotdodamagethemulti-connectorcablewhenconnectingit.
6.Aligntheguideholeinthecamerawiththeguidepinintheangeandfastenthe networkcameratothemountingbracketwiththescrews.
30
Loading...
+ 152 hidden pages