Axis 221, 223M Installation

AXIS 221/223M
Network Camera
Installation Guide
ENGLISH
FRANCAIS
DEUTSCH ESPAÑOL
ITALIANO
Important!
This product must be used in compliance with local laws and regulations.
AXIS 221/223M
Installation Guide
This installation guide provides instructions for installing the AXIS 221/223M on your network. For all other aspects of using the product, please see the User’s Manual, available on the CD included in this package, or from www.axis.com/techsup

Installation steps

1. Check the package contents against the list below.
2. Hardware overview. See page 4.
3. Connect the cables. See page 5.
4. Set an IP address. See page 6.
5. Set the password. See page 9.
6. Adjust the image and focus. See page 10

Package contents

Item Models/variants/notes
Network camera AXIS 221 Network Camera
AXIS 223M Network Camera
CS lens adaptor ring (AXIS 223M only) PS-K indoor power supply country specific Terminal block connector 10-pin connector block for connecting external devices to the I/O
terminal connector
3-pin connector block for connecting power to the 3-pin power
connector CD AXIS Network Video Product CD, including product documentation,
installation tools and other software Printed Materials AXIS 221/223M Installation Guide (this document)
Axis Warranty Document
ENGLISH
ENGLISH
ENGLISH
Important!
To use the AXIS 221/223M outdoors it must be installed in a protective housing. For more information on protective housings and other accessories, please visit www.axis.com
Page 4 AXIS 221/223M Installation Guide
Dimensions
HxWxD = 49 x 88 x 200mm (1.9" x 3.5" x 7.9") Weight = 620g (21.9oz) (power supply not included)
Status indicator
Zoom puller
(Tele/wide) Focus puller
DC-Iris
PS-K power adapter
connector
10-pin I/O terminal
Power indicator
Network indicator
Reset/Control button
connector
RS-232 connector
DC-Iris control cable
DC-Iris control cable
PS-K
connector
RS-232 connector
Network
(also PoE)
connector
Power and network indicators
Reset/Control button
Audio out
Audio in
connector
10-pin I/O
AXIS 223M - Rear view
AXIS 221 - Rear view
AXIS 221/223M
Front view
Power connector block
terminal
Product ID & Serial number (S/N). The serial number may be required during the installation.
Network
(also PoE)
connector
Network
(also PoE)
connector
power adapter
connector
Power
block

Hardware overview

GND DC+
Connect DC power (7-24V) on pins 1 and 2.
Connect AC power (10-24V) on pins 2 and 3.
AC AC
1
2
3

Connect the cables

1. Connect the camera to the network using a shielded network cable.
2. Optionally connect external input/output devices, such as alarm devices. See page 13 for information on the terminal connector pins.
3. Optionally connect an active speaker and/or external microphone (AXIS 223M only).
4. Connect power, using one of the methods listed below:
• PoE (Power over Ethernet). If available, this is automatically detected when the network cable is connected (see above).
• Connect the supplied indoor power adapter* to the power connector on the camera.
• The 3 pin power connector block on the rear panel. See the illustration below.
5. Check that the LED indicators show the correct conditions. See the table below for further details. Note that some LEDs can be disabled and may be unlit.
3 pin power connector block
ENGLISH
ENGLISH
ENGLISH
LED indicators
LED Color Description
Network Green Steady for connection to 100 Mbit/s network. Flashes for network
Status Green Shows steady green for normal operation. Note: The Status LED can be
Power Green Normal operation.
activity. Amber Steady for connection to 10 Mbit/s network. Flashes for network activity. Unlit No connection.
configured to be unlit during normal operation, or to flash only when the
camera is accessed. See the online help files for more information. Go to
Setup > System Options > LED settings
Amber Steady during startup, reset to factory default or when restoring settings. Red Slow flash for failed upgrade.
Amber Flashes green/amber during firmware upgrade.
* only use the supplied PS-K power adapter
Page 6 AXIS 221/223M Installation Guide

Assign an IP address

To make it accessible on the network, the AXIS 221/223M must be assigned an IP address.
Depending on the number of cameras you wish to install, the recommended method for assigning IP addresses in Windows is either AXIS IP Utility or AXIS Camera Management. Use the method that best suits your purpose.
Both of these free applications are available on the Axis Network Video Product CD supplied with this product, or they can be downloaded from www.axis.com/techsup
Method Recommended for Operating system
AXIS IP Utility See page 7
AXIS Camera Management See page 8
Notes:
• A network DHCP server is optional.
• The AXIS 221/223M has the default IP address 192.168.0.90
• If assigning the IP address fails, check that there is no firewall blocking the operation.
• For other methods of assigning or discovering the IP address of the AXIS 221/223M, e.g. in other operating systems, see page 12.
Single camera Small installations
Multiple cameras Large installations Installation on a different subnet
Windows
Windows 2000 Windows XP Pro Windows 2003 Server
AXIS IP Utility - single camera/small installation
AXIS IP Utility automatically discovers and displays Axis devices on your network. The application can also be used to manually assign a static IP address.
Note that the computer running AXIS IP Utility must be on the same network segment (physical subnet) as the AXIS 221/223M.
Automatic discovery
1. Check that the AXIS 221/223M is connected to the network and that power has been applied.
2. Start AXIS IP Utility.
3. When the camera appears in the window, double-click it to open its home page.
4. See page 9 for instructions on how to assign the password.
ENGLISH
ENGLISH
ENGLISH
Assign the IP address manually
1. Acquire an unused IP address on the same network segment as your computer.
2. Click the button Assign new IP address using serial number and enter the serial number and IP address for the AXIS 221/223M. The serial number is located on the
product label.
3. Click the Assign button and follow the instructions.
4. Click the Home Page button to access the camera’s web pages.
5. See page 9 for instructions on how to set the password.
Page 8 AXIS 221/223M Installation Guide
AXIS Camera Management - multiple cameras/large installations
AXIS Camera Management can automatically find and set IP addresses, show connection status, and manage firmware upgrades for multiple Axis video products.
Automatic discovery
1. Check that the camera is connected to the network and that power has been applied.
2. Start AXIS Camera Management. When the AXIS 221/223M appears in the window, double-click it to open the camera’s home page.
3. See page 9 for instructions on how to set the password.
Set the IP address in multiple devices
AXIS Camera Management speeds up the process of assigning IP addresses to multiple devices, by suggesting IP addresses from a specified range.
1. Select the devices you wish to configure (different models can be selected) and click the Assign IP button.
2. Select Obtain IP addresses automatically (DHCP), click the Update button and the program will search in the specified range and suggest an IP address for each device.
-or­Enter the range of IP addresses, the subnet mask and default router that devices can use and click the Update button.
Setup - Provides all the necessary tools for setting up the camera to requirements.
Help ­Displays online help

Set the password

When accessing the AXIS 221/223M for the first time, the ‘Configure Root Password’ dialog will be displayed.
1. Enter a password and then re-enter it, to confirm the spelling. Click OK.
2. Enter the user name root in the dialog. Note: The default administrator user name ‘root’ cannot be deleted.
3. Enter the password as set above, and click OK. If the password is lost, the AXIS 221/ 223M must be reset to the factory default settings. See page 14.
4. If required, click Yes to install AMC (AXIS Media Control), which allows viewing of the video stream in Internet Explorer. You will need administrator rights on the computer to do this.
The Live View page of the AXIS 221/223M is displayed, with links to the Setup tools, which allow you to customize the camera.
ENGLISH
ENGLISH
ENGLISH
Page 10 AXIS 221/223M Installation Guide
Zoom puller
(Tele/wide)
Focus puller

Adjust the image and focus

To adjust the position of the lens:
1. Open the Live View page in your web browser.
2. Check the image in the Live View page, and move the lens to the desired position.
To focus the AXIS 221/223M:
1. From the Basic Configuration page in the setup tools, open the Focus adjustment page.
2. Set the DC-Iris to Disabled and click Save.
3. Unscrew the zoom puller on the lens by turning it anti-clockwise. Adjust the zoom setting as required.
4. Re-tighten the zoom puller.
5. Unscrew the focus puller on the lens. Adjust the focus as required. Re-tighten the focus puller.
6. From the Focus adjustment page, set the DC-Iris to Enabled and
click Save.
Note:
The DC-Iris should always be disabled while focusing the camera. This opens the iris to its maximum, which gives the smallest depth of field and thus the best conditions for correct focusing. When the focus is set with this method it will then be maintained in any light conditions.
AXIS 221/223M Installation Guide Page 11
screw holding C/CS ring
C/CS ring
Underside of the camera
Back focus adjustment
When the lens is changed to a non­standard lens or when the focus achieved using the instructions above is not satisfactory, perform back focus adjustment as follows:
1. Loosen the screw that holds the C/ CS-ring. C is standard for AXIS 223M and CS for AXIS 221.
2. Direct the camera towards an object at least 7 meters away, set the zoom puller to max wide and check if it is possible to focus the lens.
3. Set the zoom puller to max tele and again check if it is possible to focus the lens.
4. Direct the camera towards a close object, about 30cm away, and set the zoom puller to max wide and check if it is possible to focus the lens. Set the zoom puller to max tele and again check if it is possible to focus the lens.
5. If it is not possible to focus the lens in any of the four situations above, adjust the C/CS­ring, and go back to step 2.
6. Tighten the screw that holds the C/CS-ring again.
7. After making the back focus adjustment as explained above, adjust the zoom and focus position for the desired view.
ENGLISH
ENGLISH
ENGLISH
Page 12 AXIS 221/223M Installation Guide

Other methods of setting the IP address

The table below shows the other methods available for setting or discovering the IP address. All methods are enabled by default, and all can be disabled.
UPnP™
Bonjour
Operating system
Windows (ME or XP)
MAC OSX (10.4 or later)
Notes
When enabled on your computer, the camera is automatically detected and added to “My Network Places.”
Applicable to browsers with support for Bonjour. Navigate to the Bonjour bookmark in your browser (e.g. Safari) and click on the link to access the camera’s web pages.
AXIS Dynamic DNS Service
All A free service from Axis that allows you to quickly and simply
install your camera. Requires an Internet connection with no HTTP proxy. See www.axiscam.net for more information.
ARP/Ping
All See below. The command must be issued within 2 minutes of
connecting power to the camera.
View DHCP server admin pages
All To view the admin pages for the network DHCP server, see the
server’s own documentation.
Set the IP address with ARP/Ping
1. Acquire an IP address on the same network segment your computer is connected to.
2. Locate the serial number (S/N) on the AXIS 221/223M label.
3. Open a command prompt on your computer and enter the following commands:
Windows syntax Windows example
arp -s <IP Address> <Serial Number> ping -l 408 -t <IP Address>
arp -s 192.168.0.125 00-40-8c-18-10-00 ping -l 408 -t 192.168.0.125
UNIX/Linux/Mac syntax UNIX/Linux/Mac example
arp -s <IP Address> <Serial Number> temp ping -s 408 <IP Address>
arp -s 192.168.0.125 00:40:8c:18:10:00 temp ping -s 408 192.168.0.125
4. Check that the network cable is connected to the camera and then start/restart the camera, by disconnecting and reconnecting power.
5. Close the command prompt when you see ‘Reply from 192.168.0.125: ...’ or similar.
6. In your browser, type in http://<IP address> in the Location/Address field and press Enter on your keyboard.
Notes:
• To open a command prompt in Windows: from the Start menu, select Run... and type cmd. Click OK.
• To use the ARP command on a Mac OS X, use the Terminal utility in Application > Utilities.
AXIS 221/223M Installation Guide Page 13

Unit connectors

Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet. Using shielded cables is recommended.
Power connector - For the supplied power adapter, PS-K, 9W. The center pin is positive (+).
Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is
used from a stereo signal).
Audio out - Audio output (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo connector must be used for the audio out.
Note:
Audio connectors are present only in AXIS 223M.
10 pin I/O terminal connector block
Pin Function Description
1 Output A On the external device output terminals (A and B), there is 2 Output B
3 Digital Input 1
Photocoupler Anode (+)
4 Digital Input 1
Photocoupler Cathode (-)
5 Digital Input 2
Photocoupler Anode (+)
6 Digital Input 2
Photocoupler Cathode (-) 7 RS-485-A (non-inverting) A half-duplex RS-485 interface for controlling auxiliary 8 RS-485-B (inverting) 9 DC+ Power Output This can drive the photocoupler inputs or other equipment.
10 GND Ground
no distinction between positive and negative (+ and -). The terminals use a photocoupler and are electrically isolated from the other internal circuitry. The maximum load should not exceed 100mA and the max­imum voltage should be not more than 50 VDC or 35 VAC.
Photocoupled Input 1. Electrically isolated from the chassis and connectors, this input can be supplied from an external DC voltage or the DC Power Input/Output on pins 9 (DC+) and 10 (GND).
Photocoupled Input 2. As above.
equipment.
The output voltage level is 3.0 V. A maximum current of 100mA can be sourced from the DC output.
ENGLISH
ENGLISH
ENGLISH
Page 14 AXIS 221/223M Installation Guide
Tip!
Visit www.axis.com/techsup to check if there is updated firmware available for your AXIS 221/223M. To see the currently installed firmware version, see the Basic Configuration web page in the product’s Setup tools.

Accessing the AXIS 221/223M from the Internet

Once installed, your AXIS 221/223M is accessible on your local network (LAN). To access the camera from the Internet, network routers must be configured to allow incoming traffic, which is usually done on a specific port. Please refer to the documentation for your router for further instructions. For more information on this and other topics, visit the Axis Support Web at www.axis.com/techsup

Resetting to the Factory Default Settings

This will reset all parameters, including the IP address, to the Factory Default settings:
1. Disconnect power from the camera.
2. Press and hold the Control button and reconnect power.
3. Keep the Control button pressed until the Status indicator displays amber (this may take up to 15 seconds), then release the button.
4. When the Status indicator displays green (which can take up to 1 minute) the process is complete and the camera has been reset.
5. Re-assign the IP address, using one of the methods described in this document.
It is also possible to reset parameters to the original factory default settings via the web interface. For more information, please see the online help or the user’s manual.

Further information

The user’s manual is available from the Axis Web site at www.axis.com or from the Axis Network Video Product CD supplied with this product.

AXIS 221/223M Guide d'installation Page 15

Important !
Ce produit doit être utilisé conformément aux lois et dispositions locales en vigueur.
AXIS 221/223M
Guide d'installation
Ce guide d'installation vous explique comment installer l’AXIS 221/223M sur votre réseau. Pour d'autres informations sur l'utilisation de ce produit, consultez le Manuel de l'utilisateur, disponible sur le CD fourni ou sur www.axis.com/techsup.

Étapes de l'installation

1. Vérifiez le contenu de la livraison à l'aide de la liste ci-dessous.
2. Présentation du matériel. Reportez-vous à la page 16.
3. Branchez les câbles. Reportez-vous à la page 17.
4. Paramétrez une adresse IP. Reportez-vous à la page 18.
5. Définissez le mot de passe. Reportez-vous à la page 21.

Contenu de l'emballage

Article Modèles/variantes/remarques
Caméra réseau Caméra réseau AXIS 221
Caméra réseau AXIS 223M
Bague adaptatrice pour objectif CS (AXIS 223M uniquement) Alimentation intérieure PS-K dépend du pays Connecteur pour terminaux Connecteur 10 broches pour la connexion d'équipements externes au con-
necteur E/S
Connecteur 3 broches pour la connexion de l'alimentation au connecteur
d'alimentation 3 broches CD CD AXIS Network Video Product avec la documentation du produit, les out-
ils d'installation et d'autres logiciels Documentation imprimée AXIS 221/223M Guide d'installation (le présent document)
Document de garantie d'Axis
FRANÇAIS
FRANÇAIS
FRANCAIS
Important !
Pour pouvoir être utilisée à l'extérieur, la AXIS 221/223M doit être placée dans un caisson de protection d'autres accessoires, visitez le site www.axis.com.
. Pour plus d'informations sur les caissons de protection et sur
Page 16 AXIS 221/223M Guide d'installation
Dimensions
H x L x P = 49 x 88 x 200 mm (1,9 " x 3,5 " x 7,9 ") Poids = 620 g (21,9 oz) (alimentation non incluse)
Voyant d'état
Zoom
(Avant/Arrière)
Mise au point
Iris DC
Voyant d'alimentation
Voyant de réseau
Bouton de
réinitialisation/commande
Connecteur RS-232
Câble de commande de l'iris DC
Câble de commande de l'iris DC
Connecteur RS-232
Voyants d'alimentation et de réseau
Bouton de réinitialisation/ commande
Sortie audio
Entrée audio
E/S à 10 broches
AXIS 223M - Vue arrière
AXIS 221 - Vue arrière
AXIS 221/223M-
Vue avant
Connecteur
ID du produit et numéro de série (S/N). Le numéro de série peut être requis pendant l'installation.
(également PoE)
Connecteur de réseau (également PoE)
Connecteur de réseau
d'alimentation
Connecteur
Connecteur du transformateur (PS-K)
d'alimentation
Connecteur
Connecteur du transformateur (PS-K)

Présentation du matériel

Terminal E/S à 10 broches
AXIS 221/223M Guide d'installation Page 17
GND CC+
Branchez l'alimentation CC (7-24V) sur les broches 1 et 2.
Branchez l'alimentation CA (10-24V) sur les broches 2 et 3.
CA CA
12
3

Branchement des câbles

1. Connectez la caméra à votre réseau à l'aide d'un câble de réseau blindé.
2. Si vous le souhaitez, connectez des dispositifs d'entrée/sortie externes, par exemple des dispositifs d'alarme. Reportez-vous à la page 26 pour plus d'informations sur les broches du connecteur E/S.
3. Si vous le souhaitez, connectez un haut-parleur actif et/ou un microphone externe (AXIS 223M uniquement).
4. Branchez l'alimentation à l'aide de l'une des 3 méthodes reprises ci-dessous.
• PoE (Power over Ethernet). Si elle est disponible, cette option est automatiquement
détectée lorsque le câble réseau est branché (voir ci-dessus).
• Branchez le transformateur fourni au connecteur d'alimentation* de la caméra.
• Connecteur d'alimentation 3 broches sur le panneau arrière.
Consultez la figure ci-dessous.
5. Vérifiez que les DEL indiquent les conditions correctes. Pour plus d'informations, consultez le tableau ci-dessous. Notez que certains témoins DEL peuvent être désactivés et éteints.
Connecteur d'alimentation à 3 broches
FRANÇAIS
FRANÇAIS
FRANCAIS
Témoins DEL
DEL Couleur Description
Réseau Vert Continu en cas de connexion à un réseau 100 Mbits/s. Clignote en cas
Orange Continu en cas de connexion à un réseau 10 Mbits/s. Clignote en cas
Éteint Pas de connexion.
État Vert Vert continu en cas de fonctionnement normal. Remarque : Le voyant d'état
Orange En continu pendant la réinitialisation des valeurs d'usine ou des paramètres. Rouge Clignote lentement en cas d'échec de la mise à niveau.
Alimentation Vert Fonctionnement normal.
Orange Clignote en vert/orange pendant la mise à niveau du microprogramme.
* Utilisez uniquement le bloc d'alimentation PS-K fourni
d'activité réseau.
d'activité réseau.
peut être configuré pour être éteint au cours du fonctionnement normal, ou pour clignoter uniquement lors des accès à la caméra. Reportez-vous à l'aide en ligne pour plus d'informations. Cliquez sur Setup > System Options > LED settings.
Page 18 AXIS 221/223M Guide d'installation

Attribution d'une adresse IP

Pour que l'appareil AXIS 221/223M soit accessible sur le réseau, vous devez lui affecter une adresse IP.
Selon le nombre de caméras à installer, pour attribuer des adresses IP sous Windows, il est recommandé d'utiliser AXIS IP Utility ou AXIS Camera Management. Employez l'application qui vous convient le mieux.
Ces deux applications gratuites sont disponibles sur le CD de la caméra vidéo réseau Axis fourni avec ce produit. Vous pouvez également les télécharger à partir du site www.axis.com/techsup.
Méthode Recommandée pour Système d'exploitation
AXIS IP Utility Voir page 19
AXIS Camera Man­agement Voir page 20
Remarques :
• Un serveur DHCP réseau est fourni en option.
• L'adresse IP par défaut de l'appareil AXIS 221/223M est 192.168.0.90.
• En cas d'échec de l'attribution de l'adresse IP, vérifiez qu'aucun pare-feu ne bloque l'opération.
• Pour connaître les autres méthodes d'affectation ou de repérage de l'adresse IP de la caméra AXIS 221/223M, par exemple sur d'autres systèmes d'exploitation, reportez-vous à la page page 24.
Une seule caméra Les petites installations
Plusieurs caméras Les grandes installations Installation sur un autre sous-réseau
Windows
Windows 2000 Windows XP Pro Windows 2003 Server
AXIS 221/223M Guide d'installation Page 19
AXIS IP Utility - Une seule caméra/petite installation
L'utilitaire AXIS IP Utility détecte et affiche automatiquement les périphériques Axis de votre réseau. Cette application sert également à attribuer manuellement une adresse IP statique.
Notez que l'ordinateur exécutant l'application AXIS IP Utility doit se trouver sur le même segment de réseau (sous-réseau physique) que l'appareil AXIS 221/223M.
Détection automatique
1. Vérifiez que l'appareil AXIS 221/223M est connecté au réseau et que l'alimentation est activée.
2. Démarrez AXIS IP Utility.
3. Lorsque l'icône de la caméra apparaît dans la fenêtre, double-cliquez dessus pour ouvrir la page d'accueil correspondante.
4. Consultez la page 21 pour savoir comment définir le mot de passe.
FRANÇAIS
FRANÇAIS
FRANCAIS
Affectez manuellement l'adresse IP
1. Trouvez une adresse IP inutilisée sur le même segment de réseau que celui de votre ordinateur.
2. Cliquez sur le bouton Assign IP address using serial number (Affecter l'adresse IP en utilisant le numéro de série), puis saisissez le numéro de série et l'adresse IP de la
AXIS 221/223M. Le numéro de série se trouve sur l'étiquette du produit.
3. Cliquez sur le bouton Assign (Affecter) et suivez les instructions.
4. Cliquez sur le bouton Home Page (Page d'accueil) pour accéder aux pages Web de la caméra.
5. Consultez la page 21 pour savoir comment définir le mot de passe.
Page 20 AXIS 221/223M Guide d'installation
AXIS Camera Management - Plusieurs caméras/grandes installations
AXIS Camera Management détecte et définit automatiquement les adresses IP, affiche les états de connexion et gère les mises à niveau de microprogrammes de nombreux produits vidéo Axis.
Détection automatique
1. Vérifiez que la caméra est connectée au réseau et que l'alimentation est activée.
2. Démarrez AXIS Camera Management. Double-cliquez sur l'icône AXIS 221/223M, lorsqu'elle apparaît dans la fenêtre de façon à ouvrir la page d'accueil.
3. Consultez la page 21 pour savoir comment définir le mot de passe.
Paramétrez l'adresse IP sur plusieurs appareils
AXIS Camera Management accélère le processus d'affectation d'adresses IP sur plusieurs appareils en suggérant les adresses IP parmi une plage spécifiée.
1. Sélectionnez les appareils à configurer (il peut s'agir de plusieurs modèles), puis cliquez sur le bouton Assign IP (Affecter une adresse IP).
2. Sélectionnez Obtain IP addresses automatically (DHCP) (Obtenir les adresses IP automatiquement (DHCP)), puis cliquez sur le bouton Update (Mettre à jour). L'application effectue une recherche dans la plage indiquée et suggère une adresse IP pour chaque appareil.
-ou­Saisissez la plage d'adresses IP, le masque de sous-réseau et le routeur par défaut que les appareils peuvent utiliser, puis cliquez sur le bouton Update (Mettre à jour).
AXIS 221/223M Guide d'installation Page 21
Setup (Configuration) - Contient tous les outils nécessaires pour adapter la caméra à vos besoins.
Help (Aide)
Affiche l'aide en ligne

Définition du mot de passe

Si vous accédez à la caméra AXIS 221/223M pour la première fois, la boîte de dialogue « Configure Root Password » (Configurer le mot de passe root) s'affiche à l'écran.
1. Entrez un mot de passe et entrez-le une seconde fois pour en confirmer l'orthographe. Cliquez sur OK.
2. Saisissez le nom d'utilisateur root dans la boîte de dialogue. Remarque: Le nom d'utilisateur par défaut de l'administrateur, à savoir root, ne peut pas être supprimé.
3. Entrez le mot de passe comme expliqué ci-dessus, puis cliquez sur OK. Si vous avez oublié votre mot de passe, vous devrez rétablir les paramètres d'usine par défaut de la caméra AXIS 221/223M. Reportez-vous à la page 27.
4. Si nécessaire, cliquez sur Yes (oui) pour installer AMC (Axis Media Control) afin de pouvoir visualiser le flux vidéo dans Internet Explorer. Pour ce faire, vous devrez être connecté à votre ordinateur avec les droits d'administrateur.
La page Live View (Vidéo en direct) de la caméra AXIS 221/223M s'affiche, avec des liens vers les outils de configuration pour adapter la caméra à vos besoins.
FRANÇAIS
FRANÇAIS
FRANCAIS
Page 22 AXIS 221/223M Guide d'installation
Vis de la bague de Zoom (Tele/Wide)
Vis de la bague de Focus

Réglage de l'image et du focus

Régler la position des lentilles.
1. Ouvrez la page Live View via votre navigateur WEB.
2. Vérifiez la qualité de l´image dans le live view, et régler les lentilles sur la position désirée.
Mise au point de l´AXIS 221/223M :
1. Ouvrez la page Focus Adjustment (Réglage et mise au point) de l'interface Web sous Basic Configuration > Focus (Configuration de base - Mise au point) et suivez les instructions à l'écran.
2. Placer le paramètre DC-IRIS sur Disabled puis cliquez sur Save.
3. Devissez la vis de la bague du ZOOM de l´objectif en tournant dans le sens inverse des aiguilles d'une montre, puis régler la bague de Zoom.
4. Revissez la vis de la bague du Zoom.
5. Devissez la vis de la bague de focus de l´objectif en tournant dans le sens inverse des aiguilles d'une montre, puis régler la bague de focus. Revissez la vis de la bague de focus.
6. Placer le paramètre DC­IRIS sur Enabled puis
cliquez sur Save.
Note:
Le paramètre DC-IRIS doit toujours être désactivé lors de la mise au point de la caméra. Cela ouvre l´IRIS à son maximum, ce qui permet d´avoir la plus petite profondeur de champ, et donc les meilleures conditions pour le réglage du focus. Lorsque le focus est réglé avec cette méthode, il sera conservé quelques soit les conditions de luminosités.
Loading...
+ 49 hidden pages