Installation steps
1. Check the package contents against the list below.
2. Hardware overview. See page 4.
3. Mount the hardware. See page 5.
4. Assign an IP address. See page 10.
5. Set the password. See page 13.
Package contents
ItemModels/variants/notes
Network camera•AXIS 215 PTZ 50Hz (PAL)
•AXIS 215 PTZ 60Hz (NTSC)
Power adapter12V DC
Power adapter mains
cable
(country-specific)
4-pin block connectorFor connecting external devices to the I/O terminal connector
Drop ceiling mounting kit 1 inner bracket, 1 outer bracket
Plastic domes x 21 x for surface mounting
ScrewdriverResitorx T20
Screw kit•1 x safety wire 1m (3.3 ft)
TemplateUse to mark positions for surface/drop ceiling mounting
CDAXIS Network Video Product CD, including product documentation,
Status, Network & Power
Indicator LEDs (see
page 16)
Audio out
Control button
Audio in
Position 0
°
Weights
• Camera: 0.60kg (1.32lb)
• Drop ceiling mount 0.54kg (1.19lb)
• Drop ceiling cover 0.12kg (0.26lb)
• Surface mount cover 0.13kg (0.29lb)
• Power adapter, including mains cable: 0.43kg (0.95lb)
Connectors & buttons
ENGLISH
ENGLISH
Mounting
IMPORTANT! - The AXIS 215 PTZ is designed for indoor and outdoor use. To
use the camera outdoors, it must be installed in an approved outdoor housing.
!
Please see www.axis.com for more information on outdoor housings.
Do not use the camera’s dome bubble if it is to be installed in an outdoor
housing as the use of two dome bubbles will reduce the image quality and
cause image blurring.
The front position
The AXIS 215 PTZ can pan (swivel) ±180° from position 0°, i.e. the metal tab to the left of
the connectors, as illustrated above. This position can be thought of as the “front” of the
camera, and is the point to which the camera will return whenever it is (re)started.
Page 6AXIS 215 PTZ Installation Guide
Cable inlet
4.2x38mm
screw
M4x10 resitorx
screw
The AXIS 215 PTZ can be mounted in 2 different ways:
• Surface mounted on a hard ceiling, in which case the unit is fastened directly to the
ceiling material
• Recessed in a drop ceiling, which involves cutting a hole in the ceiling and using
the supplied drop ceiling mount
Surface mounting
If the required cabling is also surface mounted, the cables should enter via the removable
cable inlet on the large plastic dome cover.
1. Use the supplied template to mark
out the positions for the screws that
will fasten the camera to the ceiling.
If required, drill holes for the
supplied mounting plugs.
2. Use the 2 supplied 4.2x38 screws to
fasten the camera to the ceiling.
3. Connect the camera to the network
using a shielded network cable.
4. Optionally connect external input/
output devices, e.g. alarm devices.
See page 15 for information on the
terminal connector pins.
5. Optionally connect an active speaker
and/or external microphone.
6. Connect the supplied indoor power
adapter to the power connector.
7. Using the supplied screwdriver,
attach the large dome cover, using
the 2 M4x10 resitorx screws.
Notes:
• When power is applied, check that the
indicator LEDs indicate the correct
conditions. See the table on page 16 for
further details.
• The dome cover can be fitted with the
clear or the smoked plastic glass. See
Replacing the dome glass, on page 9.
AXIS 215 PTZ Installation GuidePage 7
Ceiling tile
Outer ceiling bracket
Hole diameter 168-175mm
(6.6-6.9”)
inner ceiling bracket
tabs
tabs
Drop ceiling mounting
1. If possible, remove the ceiling tile in which the drop ceiling mount is to be fitted.
2. Use the supplied template to mark the position for the hole in the ceiling tile. Remove the
protective paper, fix to ceiling tile and cut around the template.
Note: The combined weight of the camera, ceiling mount and cover is 1.26 kg (2.78 lb).
Check that the ceiling material is strong enough to support this weight. The
thickness of the ceiling should be 20-60mm (0.79”-2.36”).
3. Tilt and insert the outer ceiling bracket through the hole, and then pull it into place. The
bracket should be positioned so that the 3 vertical tabs point downwards in the hole.
4. Pull all of the required cables
(network, power, etc) down through
the hole, ready for connection.
5. Align the camera’s screw holes with
the holes in the inner ceiling
bracket, and using the 4 supplied
M4x10 screws, mount the camera
on the inner ceiling bracket, as
illustrated here.
ENGLISH
ENGLISH
Page 8AXIS 215 PTZ Installation Guide
Distance between camera
and tab must be equal
distance between
camera and bracket
distance between
camera and bracket
Camera must be centered within the inner ceiling bracket
tab
tab
Safety wire
Align slots
with screws
M4x4 screw
Note: It is important that the camera is centered within the inner ceiling bracket. The
6. Adjust the length of the
7. Connect the camera to the
8. Optionally connect external
9. Optionally connect an active
10. Connect the supplied indoor
11. Lift and turn the inner bracket
distance between the camera and the rim of the inner ceiling bracket must be
equal on all sides. Measure an equal distance between the camera and the tabs on
either side of the inner ceiling bracket. Visually ensure the centering.
supplied safety wire and attach
it to both the inner bracket and
the hard ceiling above the drop
ceiling.
network using a shielded
network cable.
input/output devices, e.g.
alarm devices. See page 15 for
information on the terminal
connector pins.
speaker and/or external
microphone.
power supply to the power
connector on the camera.
(with camera) so that the
screws on the outer bracket
enter the screw slots on the
inner bracket. Make sure that
the screws go all the way to
the back of the slots.
AXIS 215 PTZ Installation GuidePage 9
M4x10 resitorx
screw
12. Gently tighten the screws so that the ceiling tile is held between the inner and outer
brackets. Check that none of the cabling is trapped by the brackets.
Note: When power is applied, check that the indicator LEDs indicate the correct condi-
tions. See the table on page 16 for further details.
13. Using the supplied screwdriver, attach the smaller dome cover, using the 2 M4x10
resitorx screws.
ENGLISH
ENGLISH
Replacing the dome glass
The dome cover can be fitted with the clear or the
smoked plastic glass. To switch covers, use a torque T6
screwdriver to remove the 4 fastening screws on the
inside of the dome, as shown here.
You are advised to take care when handling the plastic
glass, to avoid scratching it. The wearing of cotton
gloves is recommended.
Page 10AXIS 215 PTZ Installation Guide
Assign an IP address
Most networks today have a DHCP server that automatically assigns IP addresses to
connected devices. If your network does not have a DHCP server the AXIS 215 PTZ will use
192.168.0.90 as the default IP address.
If you would like to assign a static IP address the recommended method in Windows is either
AXIS IP Utility or AXIS Camera Management. Depending on the number of cameras you
wish to install, use the method that best suits your purpose.
Both of these free applications are available on the Axis Network Video Product CD supplied
with this product, or they can be downloaded from www.axis.com/techsup
MethodRecommended forOperating system
AXIS IP Utility
See page 11
AXIS Camera Management
See page 12
Notes:
• If assigning the IP address fails, check that there is no firewall blocking the operation.
• For other methods of assigning or discovering the IP address of the AXIS 215 PTZ, e.g. in other
operating systems, see page 14.
Single camera
Small installations
Multiple cameras
Large installations
Installation on a different subnet
Windows
Windows 2000
Windows XP Pro
Windows 2003 Server
AXIS 215 PTZ Installation GuidePage 11
AXIS IP Utility - single camera/small installation
AXIS IP Utility automatically discovers and displays Axis devices on your network. The
application can also be used to manually assign a static IP address.
Note that the computer running AXIS IP Utility must be on the same network segment
(physical subnet) as the AXIS 215 PTZ.
Automatic discovery
1. Check that the AXIS 215 PTZ is connected to the network and that power has been
applied.
2. Start AXIS IP Utility.
3. When the camera appears in the window, double-click it to open its home page.
4. See page 13 for instructions on how to set the password.
ENGLISH
ENGLISH
Assign the IP address manually (optional)
1. Acquire an unused IP address on the same network segment as your computer.
2. Select the AXIS 215 PTZ in the list.
3. Click the button Assign new IP address to the selected device and enter the IP
address.
4. Click the Assign button and follow the instructions.
5. Click the Home Page button to access the camera’s web pages.
6. See page 13 for instructions on how to set the password.
Page 12AXIS 215 PTZ Installation Guide
AXIS Camera Management - multiple cameras/large installations
AXIS Camera Management can automatically discover multiple Axis devices, show
connection status, manage firmware upgrades and set IP addresses.
Assign an IP address in a single device
1. Select AXIS 215 PTZ in AXIS Camera Management and
click the Assign IP button.
2. Select Assign the following IP address and enter the IP
address, the subnet mask and default router the device
will use.
3. Click the OK button.
Assign IP addresses in multiple devices
AXIS Camera Management speeds up the process of
assigning IP addresses to multiple devices, by suggesting IP
addresses from a specified range.
1. Select the devices you wish to configure (different
models can be selected) and click the Assign IP
button.
2. Select Assign the following IP address range and enter
the range of IP addresses, the subnet mask and default
router the devices will use.
3. Click the OK button.
AXIS 215 PTZ Installation GuidePage 13
Setup - Provides all
the tools for configuring the camera to
requirements.
Help - Displays
online help on all
aspects of using
the camera.
Set the password
When accessing the AXIS 215 PTZ for the first
time, the ‘Configure Root Password’ dialog
will be displayed.
1. Enter a password and then re-enter it, to
confirm the spelling. Click OK.
2. Enter the user name root in the dialog as
requested.
Note: The default administrator user name
root cannot be deleted.
3. Enter the password as set above, and click OK. If the password is lost, the AXIS 215 PTZ
must be reset to the factory default settings. See page 16.
4. If required, click Yes to install AMC (AXIS Media Control), which allows viewing of the
video stream in Internet Explorer. You will need administrator rights on the computer to
do this.
The Live View page of the AXIS 215 PTZ is displayed, with links to the Setup tools, which
allow you to customize the camera.
ENGLISH
ENGLISH
Accessing the AXIS 215 PTZ from the Internet
Once installed, your AXIS 215 PTZ is accessible on your local network (LAN). To access the
camera from the Internet, network routers must be configured to allow incoming traffic,
which is usually done on a specific port. Please refer to the documentation for your router
for further instructions. For more information on this and other topics, visit the Axis Support
Web at www.axis.com/techsup
Page 14AXIS 215 PTZ Installation Guide
Other methods of setting the IP address
The table below shows the other methods available for setting or discovering the IP address.
All methods are enabled by default, and all can be disabled.
UPnP™
Bonjour
AXIS Dynamic DNS
Service
ARP/Ping
View DHCP server
admin pages
Use in operating
system
Windows
(ME or XP)
MAC OSX
(10.4 or later)
AllA free service from Axis that allows you to quickly and simply
AllSee below. The command must be issued within 2 minutes of
AllTo view the admin pages for the network DHCP server, see the
Notes
When enabled on your computer, the camera is automatically
detected and added to “My Network Places.”
Applicable to browsers with support for Bonjour. Navigate to the
Bonjour bookmark in your browser (e.g. Safari) and click on the
link to access the camera’s web pages.
install your camera. Requires an Internet connection with no
HTTP proxy. See www.axiscam.net for more information.
connecting power to the camera.
server’s own documentation.
Set the IP address with ARP/Ping
1. Acquire an IP address on the same network segment your computer is connected to.
2. Locate the serial number (S/N) on the AXIS 215 PTZ label.
3. Open a command prompt on your computer and enter the following commands:
4. Check that the network cable is connected to the camera and then start/restart the
camera, by disconnecting and reconnecting power.
5. Close the command prompt when you see ‘Reply from 192.168.0.125: ...’ or similar.
6. In your browser, type in http://<IP address> in the Location/Address field and press Enter
on your keyboard.
Notes:
• To open a command prompt in Windows: from the Start menu, select Run... and type cmd. Click OK.
• To use the ARP command on a Mac OS X, use the Terminal utility in Application > Utilities.
AXIS 215 PTZ Installation GuidePage 15
Pin 4
Pin 3
Pin 2
Pin 1
Unit connectors
Network connector - RJ-45 Ethernet connector. Using shielded cables is recommended.
Power connector - DC connector 12V DC
connection.
Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is
used from a stereo signal).
Audio out - Audio output (line level) that can be connected to a public address (PA) system
or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A
stereo connector must be used for the audio out.
I/O terminal connector - Used in applications for e.g.
motion detection, event triggering, time lapse recording
and alarm notifications. It provides the interface to:
• 1 transistor output - For connecting external
devices such as relays and LEDs. Connected
devices can be activated by AXIS VAPIX API,
output buttons on the Live View page or by
an Event Type. The output will show as active
(shown under Event Configuration > Port Status) if the alarm device is activated.
• 1 digital input - An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass break
detectors, etc. When a signal is received the state changes and the input becomes
active (shown under Event Configuration > Port Status).
• Auxiliary power and GND
±5%, max 14.5W. See product label for ±
ENGLISH
ENGLISH
Function Pin numberNotesSpecifications
GND1Ground
12V DC
Power
Digital Input3Connect to GND to activate, or leave float-
Transistor
Output
2Can be used to power auxiliary equipment.
Note that the AXIS 215 PTZ itself cannot be
powered via the I/O terminal connector.
ing (or unconnected) to deactivate.
4Uses an open-collector NPN transistor with
the emitter connected to the GND pin. If
used with an external relay, a diode must be
connected in parallel with the load, for protection against voltage transients.
Max load = 100mA
Must not be exposed to
voltages greater than
12V DC
Max load = 100mA
Max voltage = 24V DC
(to the transistor)
Page 16AXIS 215 PTZ Installation Guide
o
z
AXIS 215 PTZ
12V
max. 100mA
e.g. pushbutton
4
o
3
o
o
2
1
Connection diagram
LED indicators
LEDColorIndication
NetworkGreenSteady for connection to a 100 Mbit/s network. Flashes for network activity.
AmberSteady for connection to 10 Mbit/s network. Flashes for network activity.
UnlitNo network connection.
StatusGreenSteady green for normal operation.
AmberSteady during startup, during reset to factory default or when restoring settings.
RedSlow flash for failed upgrade.
PowerGreenNormal operation.
AmberFlashes green/amber during firmware upgrade.
Resetting to the Factory Default Settings
This will reset all parameters, including the IP address, to the factory default settings:
1. Disconnect power from the camera.
2. Press and hold the Control button and reconnect power.
3. Keep the Control button pressed until the Status indicator displays amber (this may take
up to 15 seconds), then release the button.
4. When the Status indicator displays green (which can take up to 1 minute) the process is
complete and the camera has been reset.
5. Re-assign the IP address, using one of the methods described in this document.
It is also possible to reset parameters to the original factory default settings via the web
interface. For more information, please see the online help or the user’s manual.
AXIS 215 PTZ Installation GuidePage 17
Tip!
Visit www.axis.com/techsup to check if there is updated firmware available for your
AXIS 215 PTZ. To see the currently installed firmware version, see the Basic
Configuration web page in the product’s Setup tools.
Further information
The user’s manual is available from the Axis Web site at www.axis.com or from the Axis
Network Video Product CD supplied with this product.
ENGLISH
ENGLISH
AXIS 215 PTZ Guide d’installationPage 19
Important !
Ce produit doit être utilisé
conformément aux lois et
dispositions locales en
vigueur.
Ce guide d'installation vous explique comment installer la caméra réseau AXIS 215 PTZ sur
votre réseau. Pour d'autres informations sur l'utilisation de ce produit, consultez le Manuel
de l'utilisateur, disponible sur le CD fourni ou sur www.axis.com/techsup.
Étapes de l'installation
1. Vérification du contenu de l'emballage à l'aide de la liste ci-dessous.
2. Présentation du matériel. Reportez-vous à la page 20.
3. Installation du matériel. Reportez-vous à la page 21.
4. Attribution d'une adresse IP. Reportez-vous à la
page 27.
5. Définissez le mot de passe. Reportez-vous à la
page 30.
Contenu de l'emballage
ArticleModèles/variantes/remarques
Caméra réseau•AXIS 215 PTZ 50 Hz (PAL)
Câble d'alimentation12 V CC
Câble d'alimentation sec-
teur
(dépend du pays)
Connecteur 4 brochesPour connecter des équipements externes au connecteur pour terminaux E/S
Montage sur faux-plafond 1 support intérieur, 1 support extérieur
2 dômes en plastique1 pour le montage en saillie
TournevisResitorx T20
Kit de vis•1 fil de sécurité 1m
ModèleUtilisez le pour marquer les positions des éléments pour le montage en saillie/sur
CDCD AXIS Network Video Product avec la documentation du produit, les outils
Témoins DEL de réseau,
d'alimentation et d'état
(reportez-vous à la
page 34)
Sortie audio
Bouton de
commande
Entrée audio
Position 0
°
Poids
• Caméra 0,60 kg (1,32 livre)
• Support pour faux-plafond 0,54 kg (1,19 livre)
• Capot pour faux-plafond 0,12 kg (0,26 livre)
• Capot du support de montage en saillie 0,13 kg (0,29 livre)
• Câble d'alimentation, avec câble secteur: 0,43 kg (0,95 livre)
Connecteurs & boutons
FRANCAIS
!
Position avant
L'AXIS 215 PTZ peut pivoter à ±180° à partir de la position 0°, c'est-à-dire à partir de la
languette en métal, comme indiqué dans l'illustration ci-dessus. Cette position peut être
considérée comme la face « avant » de la caméra. La caméra revient à cette position initiale à
chaque (re)démarrage.
Montage
.IMPORTANT ! - L'AXIS 215 PTZ est conçue pour une utilisation intérieure et
extérieure. Pour pouvoir être utilisée à l'extérieur, la caméra doit être placée dans un
caisson de protection. Visitez le site www.axis.com pour plus d'informations.
Ne pas utiliser la bulle du dôme si la caméra est installé dans un caisson de protection
car l’utilisation de deux bulles réduit la qualité de l’image et donne une image trouble.
Page 22AXIS 215 PTZ Guide d’installation
Entrée de câbles
Vis de
4,2 x 38mm
Vis M4x10 Resitorx
L'AXIS 215 PTZ peut être montée de deux façons différentes:
• Montage en saillie, auquel cas l'appareil est fixé directement au matériau du
• Montage de l'appareil encastré sur un plafond, qui nécessite de percer un orifice
Montage en saillie
Si les câbles nécessaires sont également en saillie, ils doivent passer par l'élément d'entrée de
câbles amovible sur le grand capot du dôme en plastique.
1. Utilisez le modèle fourni pour
marquer la position des vis qui
fixeront la caméra au plafond. Si
nécessaire, percez des trous pour les
chevilles de montage fournies.
2. Utilisez les 2 vis 4,2 x 38 fournies
pour fixer la caméra au plafond.
3. Connectez la caméra à votre réseau à
l'aide d'un câble de réseau blindé.
4. Si vous le souhaitez, connectez des
dispositifs d'entrée/sortie externes,
par exemple des dispositifs d'alarme.
Reportez-vous à la page 32 pour plus
d'informations sur les broches du
connecteur pour terminaux.
5. Si vous le souhaitez, connectez un
haut-parleur actif et/ou un
microphone externe.
6. Branchez l'alimentation intérieure
fournie au connecteur
d'alimentation.
7. À l'aide du tournevis fourni et des 2
vis M4x10 Resitorx, fixez le grand
capot de dôme.
plafond
dans le plafond et d'utiliser le support pour faux-plafond fourni
Remarques:
• Lorsque l'appareil est sous tension,
vérifiez que les témoins DEL indiquent les
conditions correctes. Pour plus d'informations, consultez le tableau à la page 34.
• Le capot du dôme peut être monté avec la vitre en plastique fumé ou transparent. Reportez-vous à la
Remplacement de la vitre du dôme à la page 26.
AXIS 215 PTZ Guide d’installationPage 23
Dalle de plafond
Support de plafond extérieur
Diamètre du trou
168-175 mm
Montage sur un faux-plafond
1. Si possible, retirez la dalle de plafond à laquelle le support pour faux-plafond doit être
fixé.
2. Utilisez le gabarit fourni pour marquer la position du trou sur la dalle de plafond. Retirez
la protection, fixez le gabarit à la dalle de plafond et découpez autour du gabarit.
Remarque: Le poids total de la caméra et du support plafond est de 1,26 kg. Vérifiez que le
matériau du plafond est assez résistant pour supporter ce poids. L'épaisseur du plafond doit être
de 20-60 mm.
3. Inclinez le support de plafond extérieur et insérez-le dans le trou, puis mettez-le en
place. Le support doit être positionné de façon à ce que les 3 pattes verticales soient
orientées vers le bas du trou.
FRANCAIS
4. Faites descendre l'ensemble des câbles
requis (réseau, alimentation, etc.) par le
trou. Le raccordement est alors possible.
5. À l'aide des 4 vis M4x10 fournies, montez
la caméra sur le support de plafond
intérieur, comme illustré ci-dessous.
Page 24AXIS 215 PTZ Guide d’installation
tab
la caméra doit être centrée dans le support d´encastrement plafond
Distance entre la caméra et le support
Distance entre la caméra et le support
Fixation
Distance entre la camera et les fixations doit être égale
Remarque:
Il est important que la caméra soit centrée dans le support d´encastrement plafond. La distance
entre la caméra et le rebord du support d´encastrement plafond doit être egale de chaque coté.
Mersurez une distance égale entre la caméra et les fixations du support d´encastrement plafond. Visuellement assurer le centrage.
AXIS 215 PTZ Guide d’installationPage 25
Fil de sécurité
Alignez les
emplacements
par rapport
aux vis
Vis M4x4
6. Réglez la longueur du fil de
sécurité fourni et fixez-le au
support intérieur et au plafond
plein au-dessus du fauxplafond.
7. Connectez la caméra à votre
réseau à l'aide d'un câble de
réseau blindé.
8. Si vous le souhaitez,
connectez des dispositifs
d'entrée/sortie externes, par
exemple des dispositifs
d'alarme. Reportez-vous à la
page 32 pour plus
d'informations sur les broches
du connecteur pour
terminaux.
9. Si vous le souhaitez,
connectez un haut-parleur
actif et/ou un microphone
externe.
10. Branchez l'alimentation
intérieure fournie au
connecteur d'alimentation de
la caméra.
11. Soulevez et tournez le support intérieur (avec la caméra) de façon à ce que les vis situées
sur le support extérieur s'insèrent dans les emplacements prévus sur le support intérieur.
Veillez à ce que les vis soient parfaitement enfoncées dans leur emplacement.
12. Serrez délicatement les vis de façon à ce que la dalle de plafond soit maintenue entre les
supports intérieur et extérieur. Vérifiez que les supports ne bloquent aucun câble.
FRANCAIS
Remarque: Lorsque l'appareil est sous tension, vérifiez que les témoins DEL indiquent les
conditions correctes. Pour plus d'informations, consultez le tableau à la page 34.
Page 26AXIS 215 PTZ Guide d’installation
Vis M4x10 Resitorx
13. À l'aide du tournevis fourni et des 2 vis M4x10 Resitorx, fixez le petit capot de dôme.
Remplacement de la vitre du dôme
Le capot du dôme peut être monté avec la vitre
en plastique fumé ou transparent. Pour remplacer
le capot, utilisez un tournevis Torx T6. Retirez
les 4 vis situées à l'intérieur du dôme, comme
illustré ci-contre.
Manipulez la vitre en plastique avec précaution
pour ne pas la rayer. Pour cette manipulation, il
est recommandé de porter des gants en coton.
AXIS 215 PTZ Guide d’installationPage 27
Attribution d'une adresse IP
Aujourd'hui, la plupart des réseaux comportent un serveur DHCP qui attribue
automatiquement des adresses IP aux dispositifs connectés. Si ce n'est pas le cas de votre
réseau, l'AXIS 215 PTZ utilisera l'adresse IP par défaut 192.168.0.90.
Si vous souhaitez affecter une adresse IP statique, sous Windows nous recommandons
l'utilisation de l'application AXIS IP Utility ou de l'application AXIS Camera Management.
Selon le nombre de caméras à installer, utilisez la méthode qui vous convient le mieux.
Ces deux applications gratuites sont disponibles sur le CD de la caméra vidéo réseau Axis
fourni avec ce produit. Vous pouvez également les télécharger à partir du site
www.axis.com/techsup.
MéthodeRecommandée pourSystème
d'exploitation
AXIS IP Utility
Voir page 27
AXIS Camera Management
Voir page 29
Remarques:
• En cas d'échec de l'attribution de l'adresse IP, vérifiez qu'aucun pare-feu ne bloque l'opération.
• Pour connaître les autres méthodes d'affectation ou de repérage de l'adresse IP de la caméra AXIS
215 PTZ, par exemple sur d'autres systèmes d'exploitation, reportez-vous à la page 31.
Une seule caméra
Les petites installations
Plusieurs caméras
Les grandes installations
Installation sur un autre sous-réseau
Windows
Windows 2000
Windows XP Pro
Windows 2003 Server
FRANCAIS
AXIS IP Utility - Une seule caméra/petite installation
L'utilitaire AXIS IP Utility détecte et affiche automatiquement les périphériques Axis de
votre réseau. Cette application sert également à définir manuellement une adresse IP
statique.
Notez que l'ordinateur exécutant l'application AXIS IP Utility doit se trouver sur le même
segment de réseau (sous-réseau physique) que la caméra AXIS 215 PTZ.
Loading...
+ 60 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.