Auriol H13726 User Manual [cs, en, pl, de]

PREMIUM WEATHER STATION
PREMIUM WEATHER STATION
Operation and Safety Notes
PRÉMIUM IDŐJÁRÁSÁLLOMÁS
Kezelési és biztonsági utalások
METEOSTANICE
Pokyny pro obsluhu a bezpečnostní pokyny
PREMIUM-WETTERSTATION
Bedienungs- und Sicherheitshinweise
IAN 92027
Wskazówki dotyczące obsługi i bezpieczeństwa
PREMIUM VREMENSKA POSTAJA
Navodila za upravljanje in varnostna opozorila
PRÉMIOVÁ METEOSTANICA
Pokyny pre obsluhu a bezpečnostné pokyny
GB Operation and Safety Notes Page 3 PL Wskazówki dotyczące obsługi i bezpieczeństwa Strona 22 HU Kezelési és biztonsági utalások Oldal 43 SI Navodila za upravljanje in varnostna opozorila Stran 62 CZ Pokyny pro obsluhu a bezpečnostní pokyny Strana 82 SK Pokyny pre obsluhu a bezpečnostné pokyny Strana 101 DE / AT / CH Bedienungs- und Sicherheitshinweise Seite 121
Table of Contents
1. General information ...............................................................................................................Page 4
2. Intended use ............................................................................................................................ Page 4
3. Technical data .........................................................................................................................Page 4
4. Safety information ..................................................................................................................Page 5
5. Scope of delivery ....................................................................................................................Page 5
6. Definition of terms ...................................................................................................................Page 6
7. Functions ..................................................................................................................................Page 6
8. Commissioning ........................................................................................................................Page 7
9. Inserting and replacing batteries........................................................................................... Page 9
10. Device overview ......................................................................................................................Page 10
11. Preparing the wind gauge and rain gauge and registering on the weather station .........Page 12
11.1 Calibrating the wind gauge ...................................................................................................Page 12
11.2 Preparing the rain gauge .......................................................................................................Page 12
11.3 Automatic wind gauge and rain gauge registration on the weather station .....................Page 12
11.4 Manual wind gauge and rain gauge registration on the weather station .........................Page 12
12. Weather station basic settings ...............................................................................................Page 13
12.1 Setting ...................................................................................................................................... Page 13
12.2 DCF-77 synchronisation .........................................................................................................Page 14
12.3 Setting the time zone ..............................................................................................................Page 14
13. Alarm function .........................................................................................................................Page 15
14. Setting the air pressure unit ....................................................................................................Page 15
15. Air pressure adjustment ..........................................................................................................Page 15
16. Setting the wind speed unit .................................................................................................... Page 16
17. Setting the wind alarm ...........................................................................................................Page 16
18. Setting the wind chill alarm ....................................................................................................Page 16
19. Switching the Wind Alarm and the Wind Chill Alarm on and off ......................................Page 17
20. Setting the rain gauge unit .....................................................................................................Page 17
21. Setting the temperature unit ...................................................................................................Page 17
22. Display .....................................................................................................................................Page 17
22.1 Date and time ..........................................................................................................................Page 18
22.2 Time zone ................................................................................................................................Page 18
22.3 Temperature and air humidity indoors / outdoors ................................................................Page 18
22.4 Displaying Heat Index and Dew Point .................................................................................. Page 18
22.5 Rainfall quantity ......................................................................................................................Page 18
22.6 Ic e / frost alarm ....................................................................................................................... Page 19
22.7 Wind direction ........................................................................................................................Page 19
22.8 Wind speed ............................................................................................................................. Page 19
22.9 Air pressure change ................................................................................................................Page 20
22.10 Minimum and maximum values .............................................................................................Page 20
22.11 Weather forecast ....................................................................................................................Page 20
22.12 Weather trend .........................................................................................................................Page 20
23. Maintenance ...........................................................................................................................Page 20
23.1 Battery charge indicator .......................................................................................................Page 20
23.2 Rain gauge leaf filter ..............................................................................................................Page 21
24. Troubleshooting errors in the measuring results ...................................................................Page 21
25. Cleaning ..................................................................................................................................Page 21
26. Disposal ...................................................................................................................................Page 21
3 GB
General information / Intended use / Technical data
Premium weather station
1. General information
ATTENTION! READ OPERATING INSTRUCTIONS BEFORE USE! KEEP OPERATING INSTRUCTIONS IN A SAFE PLACE! THIS PRODUCT IS NOT A TOY! KEEP OUT OF REACH OF CHILDREN.
Read the operating instructions carefully and use the product as described in the instructions to avoid injury and damage. We accept no responsibility for damage resulting from inappropriate use and fail­ure to comply with the safety instructions.
Symbols used in these instructions:
WARNS OF RISK OF INJURY!
The word DANGER warns of possible risks of severe or fatal injury. The word CAUTION warns of possible risks of minor injury or damage.
POINTS TO FURTHER INFORMATION!
2. Intended use
The weather station informs you of the current weather conditions and provides a weather forecast. The weather station is equipped with a rain gauge, wind gauge, barometer, radio clock and calendar. Only for personal use. Not for commercial use.
3. Technical data
Measuring Range:
Room Temperature: 0.0 °C to +50.0 °C, Resolution: 0.1 °C
32.0 °F to 122.0 °F, Resolution: 0.1 °F Outside Temperature: –20.0 °C to +60.0 °C Resolution: 0.1 °C
–4.0 °F to +140.0 °F Resolution: 0.1 °F Air humidity: 20 to 99 % Resolution 1 % Air pressure: 850 mb to 1050 mb 850 hPa to 1050 hPa
25.1 inHg to 31 inHg (mercury column in inches)
Wind speed: 0–30 m / s 0–108 km / h 0–67 mph 0–58.3 knot 0–11 Beaufort Rainfall measurement: 0–9999 mm 0–393.66 inch Outdoor sensor range: 25 m (open area)
Exceeded range of measurement:
The following displays can be expected outside of the range of measurement:
Readings below the measurement val­ues:
– Room temperature below 0 °C: LL.L – Outdoor temperature below –50 °C: LL.L – Air humidity below 20 %: 20 % – Air pressure below 850 hPa: 850 hPa – Heat Index below 14 °C: LL.L – Dew Point below 0 °C: LL.L – Wind Chill below –90 °C: LL.L
Values above the measurement values:
– Room temperature above 50 °C: HH.H – Outdoor temperature above 70 °C: HH.H – Air humidity above 99 %: 99 % – Air pressure above 1050 hPa: 1050 hPa – Heat Index above 60 °C: HH.H – Dew Point above 60 °C: HH.H – Wind Chill above 60 °C: HH.H – Rainfall quantity above 9999 mm: HHH – Wind speed above 50 m / s: 50 m / s
WARNING!
The display becomes increasingly less clear in tem­peratures under approximately –20 °C. Depending
4 GB
Technical data / Safety information / Scope of delivery
on the type of battery, power limitations are to be expected at low temperatures (normally as of –20 °C). Do no t place the weather station or the external sensor in direct sunlight.
CAUTION!
At temperatures above 60 °C (also depending on the type of battery), the battery acid may leak.
Power Supply:
Weather station: 6 x 1.5 V battery, type AA Wind gauge: 2 x 1.5 V battery, type AA Rain gauge: 2 x 1.5 V battery, type AA
DANGER OF INJURY!
Remove the batteries from the device when empty.Never short-circuit the connection poles.This appliance can be used by children aged
from 8years and above and persons with re­duced physical, sensoryor mental capabilities or lack of experience and knowledge if they have been given supervision or instruction con­cerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Operating life with full batteries: approx. 90 operat­ing days.
WARNING!
Herewith OWIM GmbH & Co. KG, Stiftsbergstraße 1, D-74167 Neckarsulm, declares that the article Premium weather station · model number: H13726 Version: 07 / 2013 fulfills the basic requirement and the other relevant requirements of 1999 / 5 / EC.
The declaration of conformity can be found under www.owim.com.
4. Safety information
DANGER FOR CHILDREN!
Swallowing batteries could be fatal. Keep batteries
and the weather station out of the reach of children. Consult a doctor immediately if a battery is swal­lowed.
CAUTION - MATERIAL DAMAGE!
Only use the specified battery type.Ensure correct polarity.Check the batteries regularly for leaks.If the device is not used for long periods of
time, remove the batteries.
Do not immerse the weather station or the
external sensor in water or other liquids.
Follow the instructions for cleaning and storage
in this manual.
5. Scope of delivery
1
5 GB
Scope of delivery / Definition of terms / Functions
2
3
4
6. Definition of terms
Dew Point:
The dew point (Dew Point) refers to the point at which the air releases water vapour in the form of fog and / or condensate. Example: if the air is cooled down constantly and the air humidity stays the same, the relative air hu­midity increases to 100 %. This means that the dew point has been reached and the cooled air contains the maximum possible water vapour at this temperature.
Heat Index:
The heat index (Heat Index) is the air temperature felt on the human body taking into consideration the measured air temperature and the air humidity.
Wind Chill:
The wind chill (Wind Chill) refers to the difference between the measured (air temperature) and the tem­perature felt on the human body, which depends on the wind speed. The wind chill is the measurement
5
used for wind-dependant cooling of an object. Humans feel this wind chill particularly on the face. As wind chill can only be calculated for temperatures close to or under the 0 °C limit, it is mostly replaced by the heat index for higher temperatures (Heat Index).
6
1
1 weather station with stand
2
1 wind gauge with integrated temperature and
air humidity sensor
3
1 rain gauge with leaf filter
4
6 screws suitable for ø 5 mm dowels
5
6 dowels ø 5 mm
6
4 hexagonal socket head bolt M6 including
4 nuts and 8 washers
7
2 mounting clamps for wind gauge
6 GB
7
7. Functions
Weather station:
– Radio-controlled DCF-77 time signal reception
with time display, time-zone setting – Date display – Alarm clock with snooze function – Room temperature and interior humidity display
with storage of the minimum and maximum
measurement values – Outside temperature and outside humidity
display with storage of the minimum and
maximum measured values – Barometric pressure display – Weather trend display – Battery status display (weather station, wind
gauge and rain gauge) – Wind direction display
Functions /Commissioning
– Wind speed with wind alarm – Dew point display (Dew Point) – Ice/frost alert – Precipitation display – Wind speed and wind direction display – Wind chill display (Wind Chill) – Can be mounted standing or hanging – For indoor use only
Wind gauge:
– Transmits the wind speed, temperature and humid-
ity to the weather station on 434 MHz frequency – Assembled on a mast of approx. ø 25–31 mm – Can only be assembled in areas free from
buildings, walls or other obstructions, as the
measurement values will otherwise be impaired.
Rain gauge:
– Transmits rainfall quantity to the weather station
on 434 MHz frequency – Easy to stand or mount with screws on an even
surface – It is best to stand or mount the rain gauge in an
areas which are not protected from rain.
CAUTION!
Comply with the following safety in­structions when using the wind gauge and rain gauge:
– Never immerse the measuring devices in water
or other liquids – Never place the measuring devices in ovens or
microwaves – Never expose the measuring devices to temper-
atures below –20 °C or above 60 °C – Keep the measuring device away from chemicals
instructions are easier to understand if you are hold­ing the devices in your hand while reading them.
Setting up the weather station:
The weather station comes with a pre-assembled stand, making it easy to set up the weather station in the desired position.
1
PH0 0.5 x 3
ø 5 mm 5 mm
10 mm
Weather station – wall mounting:
1. Mark the drill holes (horizontal distance approxi­mately 11.3 cm) for the weather station and make sure that no electrical or water lines will be damaged before drilling the holes (ø 5 mm).
2. Push the dowel into the drilled hole until it is flush with the wall.
3. Screw the supplied screws into the dowels, allowing them to protrude slightly for the weather station to be hung on.
The pre-assembled stand can be removed from the weather station. Fold the stand downwards and pull it out of the slot. To attach again, follow the same procedure in reverse order.
8. Commissioning
WARNING!
Familiarize yourself with the weather station, wind gauge and rain gauge before assembly. The operating
7 GB
Commissioning
The wind gauge must be positioned horizontally to guarantee accurate measurements.
Hanger
Wind gauge assembly:
Choose a suitable location for your wind gauge. – The wind gauge must be set up outdoors. – The wind must be able to access the wind
gauge from all sides to enable the wind force and wind direction to be measured accurately.
– Ensure that the vane and the wind wheel are not
blocked to guarantee accurate measurements.
– The wind gauge must be assembled within the
signal transmission range. Walls reduce the transmission range. Check the signal reception on the weather station before final assembly.
Wind
wheel
Vane
Hexagonal socket head bolt
Mounting clamp
Mast
Washer
Washer
Nut
Setting up the rain gauge:
Choose a suitable location for the rain gauge. – The rain gauge must be positioned outdoors.
The device must not be impaired by objects and obstructions. Do not position under trees or next to walls.
– The rain must be able to fall on the rain gauge
without obstructions to achieve an accurate rainfall measurement.
– Ensure that rain water does not accumulate under
the rain gauge. It must be able to flow off freely.
– The rain gauge must be assembled within the
range of the signal transmission. Walls reduce the transmission range. Check the signal reception on the weather station before final assembly.
When you have found a suitable position, ensure that the surface is completely horizontal to guarantee accurate rainfall measurement.
Ideally, the wind gauge should be mounted on a mast or roof of a house, where the wind can act directly on the wind gauge.
A mast is required with a diameter of approx. 25–31 mm (not included) which stands stable and vertical. Mount the wind gauge as shown below with the hexagonal socket head bolt, washers, mounting screws and nuts provided. After assembly, ensure that the wind gauge is positioned horizontal­ly with a stable hold.
8 GB
The rain gauge can simply be stood in the desired position or fixed with the screws provided.
1. Mark the drill holes using the rain gauge before drilling the holes (ø 5 mm), ensure that no elec­trical cables or water pipes can be damaged.
2. Push the supplied dowel into the drilled hole until it is flush with the wall.
3. Fix the rain gauge with the screws provided.
9. Inserting and replacing batteries
Put the batteries first into the outdoor sensor (wind gauge / rain gauge), then into the weather station.
Weather station:
– Open the battery compartment on the rear of
the weather station in the direction of the arrow.
– Insert the batteries (6 x 1.5 V type AA) ensuring
correct polarity. When one of the two battery rows is full, a beep sounds.
– Place the battery compartment cover on the
battery compartment to close. Push the battery compartment cover in the opposite direction to the arrows until it engages.
Wind gauge:
– To open the battery compartment, loosen the
4 cross-head screws on the battery compartment
cover. – Lift off the battery compartment cover. – Insert the batteries (2 x 1.5 V type AA) ensuring
correct polarity. Ensure that the black strap lies
under the batteries. This strap can be used to
remove the batteries when they need to be re-
placed. – Place the battery compartment lid on the bat-
tery compartment again. Ensure that the sealing
ring on the battery compartment is positioned
correctly in the recess. Only then is the battery
compartment waterproof. – Tighten the 4 screws on the battery compart-
ment cover again.
Inserting and replacing batteries
Rain gauge:
– Use a slotted screwdriver to loosen the 2 adja-
cent fastening screws on the housing of the rain
gauge. – Lift the housing carefully off the base of the device. – To open the battery compartment, loosen the
4 cross-head screws on the battery compart-
ment cover. – Lift off the battery compartment cover. – Insert the batteries (2 x 1.5 V type AA) ensuring
correct polarity. – Place the battery compartment lid on the battery
compartment again. Ensure that the sealing ring
on the battery compartment is positioned cor-
rectly in the recess. Only then is the battery
compartment waterproof. – Tighten the 4 screws on the battery compart-
ment cover again. – Place the housing carefully over the base of the
device. – Fix the housing onto the base of the device
again with fastening screws.
9 GB
Inserting and replacing batteries / Device overview
10. Device overview
Fastening screw
Weather Station:
Weather forecast and air pressure
Temperature display and air
humidity indoors / outdoors
Wind speed, wind direction and rainfall quantity
Time and alarm
Buttons – front side
Button Press once Press for ap-
prox. 3 sec.
RAIN/CLEAR Precipitation
Delete data quantity day/ week/month/ total
Socket for 6V DC adaptor
(adaptor not included)
10 GB
WIND Average wind
speed (AVER­AGE) and gusts of wind (GUST)
PRESSURE Air pressure unit
modification (in Hg, mb or hPa)
CHANNEL / SEARCH
Channel selec­tion (inside, out­side or alter­nate)
HEAT INDEX
Switch display between temper­ature felt by humans (Heat
DEW POINT
Index) and dew point (Dew Point)
Air pressure
adjustment
Search for
transmitter
sensors
Device overview
Button Press once Press for ap-
prox. 3 sec.
CLOCK Switch display
between local
Set date and
time time, date and day of the week
ALARM Display and
Set alarm time active / deacti­vate alarm time
RAIN HISTORY
Current precipi­tation display and precipitation display for the last 6 days / weeks / months
WIND ALARM
Display of Wind Alarm and Wind Chill Alarm
MEMORY Display of auto-
matically saved min. and max. values for tem­perature, air humidity, dew temperature (Dew Point), temperature felt by humans (Heat Index), wind chill (Wind Chill) and wind speed
Settings
forwards
Settings fast-
forwards
Settings back Settings rewind
Button Press once Press for ap-
prox. 3 sec.
WIND UNIT Set the wind
speed unit (Beaufort, mph, m / s, km / h or knots)
RAIN UNIT Set the rainfall
quantity meas­urement unit (mm or inch)
Search for the DCF-77 transmis­sion signal
ZONE Switch between
Set world time local time and world time
C/F Switch from °C
to °F
SNOOZE / LIGHT
Snooze function / background lighting
Wind gauge:
Housing with built-in temperature gauge and air humidity gauge
Vane with built-in compas
Buttons – back side
Button Press once Press for ap-
prox. 3 sec
WIND AL
Switch the Wind Alarm and Wind Chill Alarm on and off
Transmission signal LED
Battery compartment
Wind wheel
11 GB
Device overview / Preparing the wind gauge and rain gauge and registering ...
Rain gauge:
Leaf filter
compartment
Rain rockerBattery
11. Preparing the wind gauge and rain gauge and registering on the weather station
11.1 Calibrating the wind gauge
The wind gauge must be recalibrated after every battery change. Follow the procedure outlined below: – Before inserting the battery, point the vane north. – Ensure that the wind wheel does not turn. – Insert the batteries, ensuring correct polarity
(see the instructions listed under Point 9. Inserting and replacing batteries / Wind gauge).
– The transmission signal LED lights up briefly.
The wind gauge is now calibrated.
North
MAST
11.2 Preparing the rain gauge
11.3 Automatic wind gauge and rain gauge registration on the weather station
After inserting batteries in the wind gauge and the rain gauge, insert batteries in the weather station (see the instructions listed under Point 9. Inserting and replacing batteries / Weather station).
The weather station searches automatically for the transmission signals from the wind gauge and rain gauge. The process takes approx. 4 minutes.
11.4 Manual wind gauge and rain gauge registration on the weather station
After the batteries have been replaced in the wind gauge and rain gauges, they must be registered again on the weather station. After replacing the batteries and calibrating the wind gauge, press the CHANNEL / SEARCH button on the weather station for approx. 5 seconds. The entry is confirmed with a confirmation tone. The measurement value dis­plays now flash on the wind gauge and rain gauge displays. The process can take up to 4 minutes
– Insert the batteries in the rain gauge (see the
instructions listed under Point 9. Inserting and replacing batteries / Rain gauge).
– Remove the transport protection which holds
the rain rocker.
12 GB
Weather station basic settings
12. Weather station basic settings
12.1 Setting
– 12 / 24 hour format – Time – Date format – Date
Jump to the next menu item with the CLOCK button. Press ▲ and ▼ to make the settings. If none of the set­ting buttons has been pressed for approx. 60 seconds, the weather station returns automatically to the time display.
12/24 hour format:
While in the time display, press the CLOCK button for approximately 3 seconds to access the setting mode. 24 h flashes on the display. Press ▲ and ▼ to switch between 24 h and 12 h display. AM / PM is displayed to the left of the time in 12 h display mode.
Hours:
Press the CLOCK button to set the hour. The hours now flash on the display. Use ▲ and ▼ to set the hour.
Yea r:
Press the CLOCK button a second time to set the year. The year now appears on the display. Use ▲ and ▼ to set the year.
Date format:
Press the CLOCK button again to set the month for­mat. The letters D (D = Day) and M (M = Month) flash in the date on the display. Use ▲ and ▼ to set the date format.
Month:
Press the CLOCK button again to set the month. The month now flashes on the display. Press ▲ and ▼ to set the month.
Minutes:
Press the CLOCK button again to set the minutes. The minutes now flash on the display. Use ▲ and ▼ to set the minutes.
Day:
Press the CLOCK button again to set the day. The date now flashes on the display. Press ▲ and ▼ to set the day.
Press the CLOCK button again to return to the time display.
13 GB
Weather station basic settings
12.2 DCF-77 synchronisation
This functions sets the time and date automatically. Press
to activate the synchronisation for radio­controlled DCF-77 time information. Press
and the symbol appears on the display. When the transmission signal is received, a appears. If no radio waves appear, no DCF 77 reception is available in this location. If the reception is stable, the display after approx. 3–5 minutes.
Press sation.
The displays for time and date in Central Europe are transferred via DCF-77 radio signals. The transmitter is close to Frankfurt and transmits on a transmission radius of approximately 1500 km. If your weather station receives this signal, it is not necessary to switch to and from daylight savings time. The reception quality can be restricted by the geo­graphical location (e.g. deep valleys) or structural conditions (e.g. behind concrete walls). Electromagnetic fields can also have a negative in­fluence on signal (DCF) reception. Position the weather station and the external sensor in a suitable location. Follow the instructions listed under “DCF-77 synchronisation” to switch on the transmission signal again.
symbol is shown continuously on the
again to deactivate the DCF-77 synchroni-
WARNING!
symbol
Press ▲ and ▼ to set the time zone. You can select a time zone from +12 hours to –12 hours.
Press the ZONE button to return to the time display. If no setting button is pressed for 60 seconds while in the time zone setting mode, the weather station automatically returns to the time display.
You can use the ZONE button to display the selected time zone. ZONE appears next to the time. By pressing the ZONE button again, you are returned to your local time.
WARNING!
When setting the time zone, use the following specifications:
12.3 Setting the time zone
You can switch between local time and the selected zone time while the time is displayed. The time zones are divided into 24 zones. You can select a time zone from +12 hours to –12 hours.
Setting the time zone:
Press and hold the ZONE button for approximately 3 seconds. A confirmation signal sounds and 0 flashes on the display.
14 GB
Set -1 Hr.: Atlantic, Great Britain, Ireland, Iceland, Portugal
Set 0 Hrs.: Albania, Belgium, Bosnia-Herzegovina, Denmark, Germany, France, Gibraltar, Italy, Croatia, Liechtenstein, Luxemburg, Malta, Macedonia, Monaco, The Neth­erlands, Norway, Austria, Poland, San Marino, Sweden, Switzerland, Serbia, Slovakia, Slovenia, Spain (with the exception of the Canary Islands), Czech Republic, Hungary
… / Alarm function / Setting the air pressure unit / Air pressure adjustment
Set +1 Hr.:
Bulgaria, Estonia, Finland, Greece, Latvia, Lithuania, Moldova, Romania, Turkey, Ukraine, Cyprus
All other time zones can be found in your Atlas or on the Internet.
13. Alarm function
To set the alarm time, press and hold the ALARM button for 3 seconds while the time is displayed. When the confirmation signal has sounded, ALARM appears on the display and the hours flash.
Use ▲ and ▼ to set the hours. Press the ALARM button again to jump to the min­ute setting. The minutes flash in the display.
Press the ALARM button again to reactivate the alarm function. Press the CLOCK button to return to the time display. If no button is pressed for approximately 20 seconds while the switch is being made, the weather station automatically returns to the time display.
Switching the alarm signal off:
The alarm signal sounds for approx. 2 minutes and
flashes on the display. The alarm can be turned
off prematurely by pressing the ALARM button.
Snooze function:
Press the SNOOZE / LIGHT button to pause the alarm signal for approx. 10 minutes. During this period, flashes above the time display.
The alarm signal then sounds again for approximately 2 minutes. You can interrupt the alarm signal again with the SNOOZE / LIGHT button or switch it off with the ALARM button.
Use ▲ and ▼ to set the minutes. Press the ALARM button to return to the time display.
The alarm function is activated and to the time.
Deactivating the alarm function:
Press the ALARM button twice while the time is dis­played until
disappears.
appears next
14. Setting the air pressure unit
Press the PRESSURE button to switch between the units hPA (Hectopascal), mb (Millibar) and inHg (Mercury column in inches).
15. Air pressure adjustment
When batteries have been inserted in the weather station, an air pressure of 1013 hPa appears on the display. This value is pre-set. You can adjust the air pressure to suit your current location. First find out
15 GB
... / Setting the wind speed ... / Setting the Wind Alarm / Setting the Wind Chill Alarm
the current air pressure value, e.g. from the newspaper or Internet. Hold the PRESSURE button down for approx. 3 seconds until you hear a confirmation tone. The air pressure value now flashes on the display. Use ▲ or ▼ to set the desired value. Press the PRESSURE button to return to the standard display. The standard display will also appear automatically if no setting button is pressed for approx. 1 minute.
16. Setting the wind speed unit
The wind speed can be displayed in 5 different units. – km / h (kilometres per hour) – mph (miles per hour) – m / s (meters per second) – knots – Beaufort
Press the WIND UNIT button on the rear side of the weather station to switch between the different units.
Hold the WIND ALARM button down for approx. 3 seconds until a confirmation tone sounds and the value flashes.
Use ▲ or ▼ to set the desired value. Press the WIND ALARM button to confirm the entry and appears on left next to the wind speed.
The wind alarm is now activated. Press WIND AL to deactivate the wind alarm again. Press WIND AL
until disappears.
If a gust of wind reaches or exceeds the set value, a warning signal sounds for approx. 1 minute and
flashes in the display.
17. Setting the wind alarm
A wind alarm can be set for gusts (maximum speed for the last 10 minutes). Press the WIND ALARM button until ALARM and GUST appears on the display.
16 GB
Press WIND ALARM to stop the alarm tone prema­turely. last 10 minutes) fall below the set limit value again.
flashes until the gusts of wind (over the
18. Setting the wind chill alarm
A Wind Chill Alarm can also be set. Press the WIND ALARM button until ALARM appears next to the Wind Chill temperature.
... / Switching the Wind ... / Setting the rain ... / Setting the temperature ... / Display
Hold the WIND ALARM button down for approx. 3 seconds until a confirmation tone sounds and the value flashes.
Wind Alarm on
Wind Chill Alarm on
Use ▲ or ▼ to set the desired value. Press the WIND ALARM to confirm the entry, which then appears on left next to the Wind Chill temperature
The Wind Chill Alarm is now activated. Press the WIND AL Alarm. Press WIND AL
If the Wind Chill Temperature reaches or falls below the set value, a warning signal sounds for approx. 1 minute and
Press WIND ALARM to stop the alarm tone prema­turely. rises above the limit value again.
button to deactivate the Wind Chill
until disappears.
flashes in the display.
flashes until the Wind Chill Temperature
19. Switching the Wind Alarm and
the Wind Chill Alarm on and off
Wind and Wind Chill Alarm on
20. Setting the rain gauge unit
You can choose between displaying the rainfall quantity in mm (millimetres) or in (inches). Press the RAIN UNIT button on the rear side of the weather station. Each time the button is pressed, the unit on the display changes.
21. Setting the temperature unit
The temperatures can be displayed in °C (Grad Celsius) or in °F (Grad Fahrenheit). Press the C / F button on the rear of the weather station to switch between the two units. Each time the button is pressed, the unit on the display changes.
Press the WIND AL button to switch the wind alarm and Wind Chill Alarm on and off. If the alarm is switched on, the relevant alarm symbol appears.
Wind and Wind Chill Alarm off
/
22. Display
Background illumination:
Press the SNOOZE / LIGHT button to switch on the background illumination. After approx. 10 seconds, the background illumination switches off automatically.
17 GB
Display
22.1 Date and time
Press the CLOCK button to switch between the time, date and day of the week. If no button has been pressed for a period of approximately 20 seconds, the time display appears automatically.
Time Date Day of the week
22.2 Time zone
You can use the ZONE button to display the selected time zone. ZONE appears next to the time. By pressing the ZONE button again, you are returned to your local time.
22.3 Temperature and air
humidity indoors / outdoors
Press the CHANNEL / SEARCH button to display the temperature and air humidity for indoors or outdoors. The values for indoors and outdoors can also be displayed alternately. Then,
appears on the display.
displayed in different chronicles either as a digital value or in diagram form:
Digital value:
Value
Unit
Diagram:
Unit in inches Unit in millimetres
The rainfall over the past days / weeks / months from the current time (0) up to 6 days / weeks / months earlier (–6)
Press the RAIN / CLEAR button to switch between the following rainfall quantity displays: – Total rainfall quantity – Rainfall quantity each day – Rainfall quantity each week – Rainfall quantity each month
22.4 Displaying Heat Index and
Dew Point
Press the HEAT INDEX; DEW POINT button to switch between the Heat Index and Dew Point.
22.5 Rainfall quantity
The weather station has an automatic memory for the amount of rainfall. The rainfall quantity can be
18 GB
The current value is displayed. A diagram is shown under this value containing the relevant history of the last 6 units.
Overall quantity
Quantity each day
Quantity each week
Quantity each month
Detailed information can be displayed on the history.
Example:
Press the RAIN / CLEAR until the rainfall quantity is shown. The value shown represents the rainfall quantity for the current day. Underneath this value,
Display
a diagram is shown containing the rainfall quantity for the current day and the past 6 days.
Press the RAIN HISTORY button to view the details. Every time the button is pressed, the display moves forward by one day. Below, you will find a display for the past 2 days:
Current day: rainfall
quantity 250.2 mm with bar display at 0
1 day earlier: rainfall
quantity 0.0 mm with bar display at –1
22.6 Ice / frost alarm
As soon as the outdoor temperature falls below 4 °C, the frost alarm symbol appears on the display. This warns of possible ground frost.
22.7 Wind direction
The wind gauge automatically shows the average wind direction for the last 2 minutes.
N = North NE = North East E = East SE = South East S = South SW = South West W = West NW = North West
22.8 Wind speed
The weather station shows the average wind speed (AVERAGE) for the last 2 minutes and the maximum speed for gusts of wind (GUST) in the last 10 minutes. Press the WIND button to switch between the two displays.
2 days earlier: rainfall
quantity 156.7 mm with bar display at –2
You can display the history for weekly and monthly quantities using the same procedure. There is no history for the total amount (TOTAL).
19 GB
Display / Maintenance
22.9 Air pressure change
The weather station shows the changes in air pressure over the last 6 hours.
Unit in inHg
Hour trend
Unit in hPa (mb)
22.10 Minimum and maximum values
Use the MEMORY button to display saved minimum and maximum values.
22.11 Weather forecast
The weather station can predict the weather for the next 12–24 hours. The weather prediction function is based on the change in air pressure and is up to 75 % accurate. Since the weather can never be pre­dicted with 100 % correctness, the manufacturer cannot be held responsible for incorrect weather predictions.
Sunny Mainly sunny Rain StormsCloudy
22.12 Weather trend
The weather trend is also shown in addition to the weather forecast. There is an arrow for increasing, stable and decreasing.
23. Maintenance
23.1 Battery charge indicator
If the battery is empty, the symbol appears in the display. There is a separate symbol for the weather station, the wind gauge and the rain gauge.
If the indoors tempera-
ture is displayed, the battery charge indica­tor applies for weather station. If the outside temperature is shown, the battery charge indi­cator applies for the wind gauge.
Battery charge indicator
for the rain gauge
Replace the batteries as soon as display. If the batteries are weak or empty, it is im­possible to guarantee accurate measurement results. The procedure for replacing the batteries is outlined under point 9. Inserting and replacing batteries.
appears in the
20 GB
Maintenance / Troubleshooting errors in the … / Cleaning / Disposal
23.2 Rain gauge leaf filter
Remove foliage and any other objects which collect in the leaf filter of the rain gauge regularly. Only then can precise rain measurement be guaranteed.
24. Troubleshooting errors in the
measuring results
WARNING! The weather station and the outside
sensor contain sensitive electronic components. Radio waves transmitted e.g. from mobile telephones, walkie talkies, radios, remote controls or microwaves may influence the functionality of the weather station and the outside sensor and lead to imprecise meas­urements. It is therefore important to maintain as great a distance as possible between the weather station and the external sensor and devices which send out radio waves. Electrostatic charge can also influence the measuring results. In this case, reset the weather station and the external sensor. This is done by removing the batteries and inserting them again after approximately 5 seconds. NOTE! All saved data is lost.
Obstacles such as concrete walls can also cause that the reception is disturbed. In this case, change the location (eg near a window). Please take note that the external sensor should always be set up within max. 25 meters (open space) from the base station. The specified range is the free-field range and means that no obstacle should be between the remote sensor and the base station. A “visual con­tact” between remote sensor and base station often improves the transmission.
Cold (outdoor temperatures below 0°C) can reduce the battery power of the outdoor sensor and thereby negatively impair the radio transmission.
If your weather station is not working correctly, please remove the batteries for a short while and then replace them.
25. Cleaning
Only clean the device with a damp cloth. Never immerse the weather station, wind gauge or rain gauge in water.
26. Disposal
Disposing of the devices:
Never dispose of the devices in normal household waste. The devices should be disposed of via an authorized waste disposal company or your local waste disposal organization. The valid regulations must be complied with. If in doubt, contact your waste disposal organization.
Disposing of batteries:
Dispose of the batteries before disposing of the device. Old batteries should not
Pb
be disposed of in household waste. Return your used batteries to your dealer or the designated returns point.
Disposing of packaging:
Dispose of all packaging material in an
environmentally friendly manner.
EMC
Another factor that may cause harmful interference, are dead or weak batteries in the outdoor sensor. Replace them by new ones.
21 GB
Spis zawartości
1. Informacje ogólne .............................................................................................................. Strona 23
2. Stosowanie zgodne z przeznaczeniem ...........................................................................Strona 23
3. Dane techniczne .................................................................................................................Strona 23
4. Wskazówki dot. bezpieczeństwa .....................................................................................Strona 24
5. Zakres dostawy .................................................................................................................. Strona 25
6. Wyjaśnienie terminów........................................................................................................Strona 25
7. Funkcje ................................................................................................................................Strona 26
8. Pierwsze uruchomienie ....................................................................................................... Strona 26
9. Włożenie i wymiana baterii ..............................................................................................Strona 28
10. Budowa urządzenia ........................................................................................................... Strona 30
11. Przygotowanie wiatromierza i deszczomierza oraz
zgłoszenie do stacji meteorologicznej .............................................................................. Strona 31
11.1 Kalibracja wiatromierza ....................................................................................................Strona 31
11.2 Przygotowanie deszczomierza .........................................................................................Strona 32
11.3 Automatyczne zgłoszenie wiatromierza i deszczomierza do stacji meteorologicznej ..... Strona 32
11.4 Ręczne zgłoszenie wiatromierza i deszczomierza do stacji meteorologicznej ............. Strona 32
12. Podstawowe ustawienia stacji meteorologicznej ............................................................. Strona 32
12.1 Ustawianie ..........................................................................................................................Strona 32
12.2 Synchronizacja czasu DCF-77 ..........................................................................................Strona 33
12.3 Ustawianie strefy czasowej ...............................................................................................Strona 34
13. Funkcja alarmu ...................................................................................................................Strona 34
14. Ustawienie jednostki ciśnienia atmosferycznego .............................................................Strona 35
15. Dopasowanie ciśnienia atmosferycznego ........................................................................ Strona 35
16. Ustawienie jednostki prędkości wiatru .............................................................................. Strona 36
17. Ustawienie alarmu wiatru ..................................................................................................Strona 36
18. Ustawienie alarmu temperatury odczuwalnej (zimny wiatr) ...........................................Strona 36
19. Włączenie i wyłączenie alarmu wiatru i alarmu temperatury odczuwalnej ..................Strona 37
20. Ustawienie jednostki pomiaru opadów deszczu .............................................................Strona 37
21. Ustawienie jednostki temperatury .....................................................................................Strona 38
22. Wskazania ......................................................................................................................... Strona 38
22.1 Godzina i data ...................................................................................................................Strona 38
22.2 Strefa czasowa ................................................................................................................... Strona 38
22.3 Temperatura i wilgotność powietrza wewnątrz / na zewnątrz .......................................Strona 38
22.4 Wyświetlenie indeksu cieplnego (Heat Index) i temperatury punktu rosy (Dew Point) .... Strona 38
22.5 Ilość deszczu ......................................................................................................................Strona 38
22.6 Alarm informujący o lodzie /mrozie .................................................................................Strona 39
22.7 Kierunek wiatru ................................................................................................................... Strona 39
22.8 Prędkość wiatru ..................................................................................................................Strona 40
22.9 Zmiany ciśnienia atmosferycznego ................................................................................... Strona 40
22.10 Wartości minimalne i maksymalne .................................................................................... Strona 40
22.11 Prognoza pogody .............................................................................................................. Strona 40
22.12 Tendencja pogody ............................................................................................................. Strona 40
23. Konserwacja .......................................................................................................................Strona 40
23.1 Wskazanie niskiego naładowania baterii ....................................................................... Strona 40
23.2 Sitko na liście deszczomierza ............................................................................................ Strona 41
24. Usuwanie błędów w przypadku zakłócenia wyników pomiaru .....................................Strona 41
25. Czyszczenie........................................................................................................................ Strona 41
26. Utylizacja ............................................................................................................................Strona 41
22 PL
Informacje ogólne / Stosowanie zgodne z przeznaczeniem / Dane techniczne
Stacja meteorologiczna premium
1. Informacje ogólne
UWAGA! PRZED UŻYCIEM PRZECZYTAĆ INSTRUKCJĘ OBSŁUGI! INSTRUKCJĘ OBSŁUGI STARANNIE PRZECHOWYWAĆ! ARTYKUŁ NIE JEST PRZEZNACZONY DO ZABAWY! CHRONIĆ PRZED DZIEĆMI.
Uważnie przeczytać wskazówki dotyczące bezpie­czeństwa oraz stosować produkt zgodnie z instrukcją, aby zapobiec zranieniom lub szkodom materialnym. Za szkody, które powstały na skutek nieprawidłowego korzystania z produktu lub nieprzestrzegania wska­zówek bezpieczeństwa, producent nie ponosi od­powiedzialności.
Symbole stosowane w niniejszej instrukcji:
STANOWI OSTRZEŻENIE PRZED
NIEBEZPIECZEŃSTWEM ZRANIENIA!
Słowo NIEBEZPIECZEŃSTWO ostrzega przed możliwymi zranieniami oraz zagrożeniem życia. Słowo OSTROŻNIE ostrzega przed możliwością odniesienia lekkich urazów lub uszkodzeń urządzenia.
3. Dane techniczne
Zakres pomiaru:
Temperatura powietrza: 0,0 °C do +50,0 °C,
dokładność: 0,1 °C 32,0 °F do 122,0 °F, dokładność: 0,1 °F Temperatura zewnętrzna: –20,0 °C do +60,0 °C, dokładność: 0,1 °C –4,0 °F do +140,0 °F, dokładność: 0,1 °F Wilgotność powietrza: 20 do 99 % dokładność 1 % Ciśnienie atmosferyczne: 850 mb do 1050 mb 850 hPa do 1050 hPa 25,1 inHg do 31 inHg
(wys. słupka rtęci w
calach) Prędkość wiatru: 0–30 m / s 0–108 km / h 0–67 mph 0–58,3 węzłów 0–11 stopni w skali
Beauforta Pomiar opadów deszczu: 0–9999 mm 0–393,66 cali Zasięg czujnika zewnętrznego: 25 m (otwarta przestrzeń)
OZNACZA INFORMACJE DODATKOWE / UZUPE ŁNIAJĄCE !
2. Stosowanie zgodne z przeznaczeniem
Stacja meteorologiczna z wiatromierzem informuje o bieżących warunkach pogodowych. Ponadto podaje także prognozę pogody. Stacja meteorologiczna z wiatromierzem jest wyposażona w desz wiatromierz, barometr, zegar synchronizowany pomocą fal radiowych oraz kalendarz. Tylko do użytku prywatnego. Nie nadaje się do zastosowań profesjo­nalnych.
czomierz,
za
Przekroczenie zakresu pomiaru:
Wskazania znajdujące się poza zakresem pomiaru:
Spadek poniżej dolnej granicy wartości pomiaru:
– Temperatura pomieszczenia poniżej 0 °C: LL.L – Temperatura zewnętrzna poniżej –50 °C: LL.L – Wilgotność powietrza poniżej 20 % : 20 % – Ciśnienie atmosferyczne poniżej 850 hPa:
850 hPa – Indeks cieplny (Heat Index) poniżej 14 °C: LL.L – Temperatura punktu rosy poniżej 0 °C : LL.L – Temperatura odczuwalna (zimny wiatr) poniżej
–90 °C : LL.L
23 PL
Dane techniczne / Wskazówki dot. bezpieczeństwa
Przekroczenie wartości pomiaru:
Temperatura pomieszczenia powyżej 50 °C: HH.H – Temperatura zewnętrzna powyżej 70 °C: HH.H – Wilgotność powietrza powyżej 99 %: 99 % – Ciśnienie atmosferyczne powyżej
1050 hPa: 1050 hPa –
Indeks cieplny (Heat Index) powyżej 60 °C: HH.H – Temperatura punktu rosy powyżej 60 °C: HH.H – Temperatura odczuwalna (zimny wiatr)
powyżej 60 °C: HH.H – Ilość opadów powyżej 9999 mm: HHH – Prędkość wiatru powyżej 50 m / s: 50 m
UWAGA!
/ s
Na wyświetlaczu w temperaturze poniżej –20 °C mogą wystąpić problemy z odczytem. W zależności od typu baterii, w niskich temperaturach (z reguły od –20 °C) mogą wystąpić problemy z zasilaniem. Stacja oraz czujnik zewnętrzny nie powinny być wystawione na działanie promieni słonecznych.
OSTROŻNIE!
W temperaturze powyżej 60 °C może dojść do wycieku elektrolitu (w zależności od typu baterii).
Zasilanie:
Stacja meteorologiczna: 6 baterii 1,5 V, typ AA Wiatromierz: 2 baterie 1,5 V, typ AA Deszczomierz: 2 baterie 1,5 V, typ AA
Żywotność całkowicie naładowanej baterii: ok. 90 dni
UWAGA!
My, firma OWIM GmbH & Co. KG, Stiftsberg­straße 1, D-74167 Neckarsulm, Wielka Brytania, oświadczamy na naszą wyłączną odpowiedzialność, że produkt: Stacja meteorologiczna premium nr modelu: H13726 wersja: 07 / 2013, do której odnosi się niniejsza deklaracja, jest zgodny z nor­mami / dokumentami normalizacyjnymi Dyrektywy 1999 / 5 / EC.
Tę dokumentację można w razie potrzeby pobrać pod adresem www.owim.com.
4. Wskazówki dot. bezpieczeństwa
Połknięcie baterii zagraża życiu. Baterie i stację
meteorologiczną należy przechowywać w miejscu niedostępnym dla dzieci. W przypadku połknię­cia baterii należy niezwłocznie skontaktować się z lekarzem.
NIEBEZPIECZEŃSTWO ZRANIENIA!
Puste baterie należy wyjąć z urządzenia.Pod żadnym pozorem nie zwierać biegunów. Niniejsze urządzenie może być używane przez
dzieci od lat 8 oraz przez osoby z obniżonymi zdolnościami fizycznymi, sensorycznymi lub mentalnymi lub brakiem doświadczenia i / lub wiedzy, jeśli pozostają pod nadzorem lub zostały pouczone w kwestii bezpiecznego użycia urzą­dzenia i rozumieją wynikające z niego zagro­żenia. Dzieci nie mogą bawić się urządzeniem. Czyszczenie i konserwacja przez użytkownika nie mogą być bez nadzoru przeprowadzane przez dzieci.
Stosować wyłącznie podany typ baterii.Zwrócić uwagę na prawidłową biegunowość.Regularnie sprawdzać, czy z baterii nie wycieka
elektrolit.
Przy dłuższej przerwie w użytkowaniu wyjąć
baterię z urządzenia.
Nigdy nie zanurzać stacji meteorologicznej
oraz czujnika zewnętrznego w wodzie lub innych cieczach.
NIEBEZPIECZEŃSTWO DLA DZIECI!
OSTROŻNIE - SZKODY RZECZOWE!
24 PL
Wskazówki dot. bezpieczeństwa / Zakres dostawy / Wyjaśnienie terminów
Przestrzegać zawartych w niniejszej instrukcji
wskazówek dot. czyszczenia i przechowywania.
5. Zakres dostawy
1
2
3
6
1
1 stacja meteorologiczna z nóżką podpierającą
2
1 wiatromierz z wbudowanym czujnikiem tem-
peratury i wilgotności powietrza
3
1 deszczomierz z sitkiem na liście
4
6 wkrętów o przekroju ø 5 mm
5
6 kołków o przekroju ø 5 mm
6
4 śruby z łbem walcowym o gnieździe sześcio-
kątnym M6 z 4 nakrętkami i 8 podkładkami
7
2 obejmy mocujące do wiatromierza
7
6. Wyjaśnienie terminów
Dew Point:
W przypadku punktu rosy (Dew Point) chodzi o tem­peraturę, przy której w powietrzu wytrąca się para wodna w formie mgły i / lub wody kondensacyjnej. Przykład: Jeśli powietrze jest stale ochładzane, w przypadku stałej wilgotności powietrza relatywna wilgotność powietrza wzrasta do 100 %. Wówczas osiągnięty jest punkt rosy, a schłodzone powietrze zawiera przy tej temperaturze najwyższą możliwą ilość pary wodnej.
4
Heat Index:
W przypadku indeksu cieplnego (Heat Index) chodzi o temperaturę powietrza, którą odczuwa ciało ludzkie z uwzględnieniem zmierzonej temperatury powietrza oraz istniejącej wilgotności powietrza.
Wind Chill:
Temperatura odczuwalna (Wind Chill) to różnica
5
pomiędzy zmierzoną temperaturą (temperaturą powietrza) i odczuwalną temperaturą, która zależy od prędkości wiatru. Temperatura odczuwalna jest miarą ochłodzenia obiektu spowodowanego dzia­łaniem wiatru. Temperatura ta jest odczuwana przez człowieka szczególnie na twarzy. Ponieważ temperatura odczuwalna może być obli-
25 PL
Wyjaśnienie terminów / Funkcje / Pierwsze uruchomienie
czona tylko przy temperaturach w okolicach lub poniżej granicy 0 °C, w przypadku wyższych tem­peratur jest ona zwykle zastępowana przez indeks cieplny (Heat Index).
7. Funkcje
Stacja meteorologiczna:
– Zegar synchronizowany za pomocą fal radio-
wych według sygnału czasu DCF-77; ustawie-
nie strefy czasowej – Wskazanie daty – Budzik z funkcją drzemania – Wskazanie temperatury pomieszczenia i wil-
gotności powietrza w pomieszczeniu z zapisem
minimalnych i maksymalnych wartości pomiaru – Wskazanie temperatury zewnętrznej i wilgotności
powietrza na zewnątrz z zapisem minimalnych
i maksymalnych wartości pomiaru – Wskazanie ciśnienia atmosferycznego – Wskazanie tendencji pogody – Wskazanie stanu baterii (stacja meteorologiczna,
wiatromierz i deszczomierz) – Wskazanie kierunku wiatru – Wskazanie siły wiatru z funkcją alarmu wiatru – Wskazanie temperatury punktu rosy (Dew Point) – Alarm informujący o lodzie / mrozie – Wskazanie opadów – Wskazanie prędkości i kierunku wiatru – Wskazanie temperatury odczuwalnej (Wind
Chill) – Może pracować w pozycji stojącej lub wiszącej – Tylko do użytku w pomieszczeniach!
Deszczomierz:
– Przekazuje do stacji meteorologicznej dane
dotyczące ilości deszczu na częstotliwości 434 MHz
– Łatwe ustawienie lub montaż na płaskiej po-
wierzchni za pomocą śrub
– Zaleca się ustawienie lub montaż urządzenia
miejscu, które nie jest chronione przed deszczem
OSTROŻNIE!
Należy przestrzegać następujących wskazówek bezpieczeństwa dotyczą­cych wiatromierza i deszczomierza:
– Nigdy nie zanurzać przyrządów pomiarowych
w wodzie lub innych cieczach
– Nie wkładać przyrządów pomiarowych do
piekarnika ani kuchenki mikrofalowej
– Nie wystawiać przyrządów pomiarowych na
działanie temperatury poniżej –20 °C lub powyżej 60 °C
– Trzymać z dala od środków chemicznych
8. Pierwsze uruchomienie
UWAGA!
Przed montażem należy się zapoznać ze stacją meteorologiczną, wiatromierzem i deszczomierzem. Trzymając przyrządy w ręku, łatwiej jest zrozumieć instrukcję obsługi.
w
Wiatromierz:
– Przekazuje do stacji meteorologicznej dane
dotyczące prędkości wiatru, temperatury oraz
wilgotności powietrza na częstotliwości 434 MHz – Montaż na maszcie o średnicy ok. ø 25–31 mm – Montaż wyłącznie w przestrzennym miejscu bez
negatywnego oddziaływania budynków, murów
lub innych przeszkód. W przeciwnym razie
może dojść do nieprawidłowości pomiaru.
26 PL
Ustawienie stacji meteorologicznej w pozycji stojącej:
Stacja meteorologiczna jest wyposażona w zamon­towaną fabrycznie nóżkę, która umożliwia praktyczne ustawienie urządzenia w pozycji stojącej.
1
PH0 0.5 x 3
ø 5 mm 5 mm
10 mm
Montaż stacji meteorologicznej na ścianie:
1. Zaznaczyć miejsca na wiercone otwory stacji
meteorologicznej (odstęp w poziomie 11,3 cm),
pamiętając o tym, aby podczas wiercenia otwo-
rów (ø 5 mm) nie uszkodzić przewodów elek-
trycznych, rur z wodą lub podobnych instalacji.
2. Umieścić kołki w otworach, tak aby były całko-
wicie schowane.
3. Wkręcić w kołki dołączone wkręty, zostawiając
wystającą część wkrętu, na którym zostanie za-
wieszona stacja meteorologiczna.
Zamontowana fabrycznie nóżka stacji meteorolo­gicznej może zostać zdemontowana. Przesunąć nóżkę na dół i wyjąć ją z zagłębienia. W celu za­montowania nóżki należy postępować w odwrotnej kolejności.
Pierwsze uruchomienie
Montaż wiatromierza:
Znaleźć odpowiednie miejsce do montażu wiatromierza. – Miejsce montażu musi się znajdować na otwartej
przestrzeni.
– Wiatr musi oddziaływać na wiatromierz ze
wszystkich stron, aby siła i kierunek wiatru mogły zostać prawidłowo zmierzone.
– Wiatrowskaz i wirnik nie mogą być zablokowane,
aby możliwe było prawidłowe przeprowadzenie pomiarów.
– Wiatromierz musi być zamontowany w zasięgu
transmisji fal radiowych. Mury i ściany redukują zasięg fal radiowych. Przed ostatecznym za­montowaniem sprawdzić odbiór fal radiowych w stacji meteorologicznej.
Zaleca się zamontowanie wiatromierza na maszcie lub dachu budynku. W tych miejscach wiatr może bezpośrednio oddziaływać na wiatromierz.
Wymagany jest maszt o średnicy ok. 25–31 mm (nie znajduje się w zakresie dostawy), stojący sta­bilnie w pozycji pionowej. Przymocować wiatromierz w sposób pokazany na rysunku poniżej przy użyciu dołączonych śrub z łbem walcowym o gnieździe sześciokątnym, podkładek, śrub mocujących i nakrętek. Po zamontowaniu upewnić się, że wiatromierz jest ustawiony w pozycji poziomej oraz jest dobrze przymocowany. Pozycja pozioma wiatromierza jest niezbędna do przeprowadzenia dokładnego pomiaru.
Zawieszka
27 PL
Pierwsze uruchomienie / Włożenie i wymiana baterii
3. Przymocować deszczomierz za pomocą śrub znajdujących się w zestawie.
MasztWiatrowskaz
9. Włożenie i wymiana baterii
Najpierw włożyć baterie do czujnika
Śruba z łbem walcowym o
Wirnik
gnieździe sześciokątnym
Podkładka
Obejma mocująca
Podkładka
Nakrętka
Ustawienie deszczomierza w odpowied­niej pozycji:
Znaleźć odpowiednie miejsce do montażu deszczo­mierza. – Miejsce montażu musi się znajdować na otwartej
przestrzeni. Nie mogą się w nim znajdować żadne przeszkadzające przedmioty ani inne przeszkody. Nie stawiać pod krzakami oraz obok murów.
– Opad deszczu musi swobodnie oddziaływać
na deszczomierz, aby mógł nastąpić dokładny pomiar opadów deszczu.
– Należy zwrócić uwagę, aby pod deszczomie-
rzem nie zbierała się woda. Zapewnić swobodny odpływ wody.
– Deszczomierz musi być zamontowany w zasię-
gu transmisji radiowej. Mury i ściany redukują zasięg fal radiowych. Przed ostatecznym wybo­rem miejsca montażu sprawdzić odbiór fal ra­diowych w stacji meteorologicznej.
Po znalezieniu odpowiedniego miejsca należy się upewnić, że powierzchnia jest całkowicie pozioma, aby możliwe było przeprowadzenie dokładnego pomiaru opadów deszczu.
Deszczomierz może być ustawiony lub zamocowany za pomocą śrub dołączonych do zestawu.
1. Zaznaczyć miejsca na wiercone otwory, pamię­tając o tym, aby podczas wiercenia otworów (ø 5 mm) nie uszkodzić przewodów elektrycz­nych, rur z wodą czy podobnych instalacji.
2. Umieścić dołączone kołki w otworach, tak aby były całkowicie schowane.
28 PL
zewnętrznego (wiat romi erz / de szczo ­mierz) a następnie do stacji pogody.
Stacja meteorologiczna:
– Otworzyć komorę baterii z tyłu stacji meteoro-
logicznej w kierunku strzałki.
– Włożyć baterie (6 x 1,5 V typ AA), zwracając
uwagę na bieguny. Bezpośrednio po umiesz­czeniu pierwszego rzędu baterii będzie słyszalny sygnał dźwiękowy.
– Aby zamknąć komorę baterii, należy nałożyć
pokrywę na komorę baterii. Następnie przesunąć pokrywę w kierunku przeciwnym do strzałki, aż się zatrzaśnie.
Wiatromierz:
– Aby otworzyć komorę baterii, należy odkręcić
4 śrubki z rowkami krzyżowymi na pokrywie
komory baterii. – Podnieść pokrywę komory baterii. – Włożyć baterie (2 x 1,5 V typ AA), zwracając
uwagę na bieguny. Zwrócić uwagę na czarny
języczek pod bateriami. Za jego pomocą można
wyjąć baterie w celu wymiany. – Założyć z powrotem pokrywę na komorę baterii.
Zwrócić uwagę, aby pierścień uszczelniający
leżał prawidłowo w odpowiednim zagłębieniu.
Tylko wówczas zapewniona jest wodoszczelność
komory baterii. – Dokręcić 4 śrubki pokrywy komory baterii do
oporu.
Deszczomierz:
– Odkręcić przy użyciu zwykłego śrubokręta
2 przeciwległe śruby mocujące od obudowy deszczomierza.
– Ostrożnie podnieść obudowę od podstawy
urządzenia.
– Aby otworzyć komorę baterii, należy odkręcić
4 śrubki z rowkami krzyżowymi na pokrywie
komory baterii. – Podnieść pokrywę komory baterii. – Włożyć baterie (2 x 1,5 V typ AA), zwracając
uwagę na bieguny. – Założyć z powrotem pokrywę na komorę baterii.
Zwrócić uwagę, aby pierścień uszczelniający
leżał prawidłowo w odpowiednim zagłębieniu.
Tylko wówczas zapewniona jest wodoszczelność
komory baterii. – Dokręcić 4 śrubki pokrywy komory baterii do
oporu. – Ostrożnie nałożyć z powrotem obudowę na
urządzenie. – Przymocować z powrotem obudowę do urzą-
dzenia za pomocą śrub mocujących.
Włożenie i wymiana baterii
Śruba mocująca
Gniazdko dla adaptera DC 6V
(adapter poza zasięgiem dostawy)
29 PL
Budowa urządzenia
10. Budowa urządzenia
Stacja meteorologiczna:
Prognoza pogody i ciśnienie atmosferyczne
Prędkość wiatru, kierunek wiatru i ilość deszczu
Przyciski z przodu
Przycisk
RAIN / CLEAR Ilość opadów
Wskazanie temperatury i wilgotności
powietrza wewnątrz / na zewnątrz
Nacisnąć jednokrotnie
na dzień / tydzień / miesiąc / razem
Czas i alarm
Nacisnąć i przytrzymać przez ok. 3 sekundy
Usuwanie da­nych
Przycisk Nacisnąć
jednokrotnie
HEAT INDEX
Zmiana wskaza­nia pomiędzy temperaturą od­czuwalną (Heat
DEW POINT
Index) a punk­tem rosy (Dew Point)
CLOCK Zmiana wskaza-
nia pomiędzy czasem lokal­nym, datą i dniem tygodnia
ALARM Wyświetlenie i
aktywowanie / dezaktywowanie czasu alarmu
RAIN HISTORY
Wskazanie opa­dów bieżących i z ostatnich 6 dni / miesięcy
WIND ALARM
Wskazanie alar­mu wiatru i alar­mu temperatury odczuwalnej
tygodni /
Nacisnąć i przytrzymać przez ok. 3 sekundy
Ustawienie czasu i daty
Ustawienie czasu alarmu
WIND Średnia pręd-
kość wiatru (AVERAGE) i szkwał (GUST)
PRESSURE Zmiana jednost-
ki ciśnienia atmosferyczne­go (inHg, mb lub hPa)
CHANNEL / SEARCH
Wybór kanału (wewnętrzny, zewnętrzny lub naprzemienny)
30 PL
Dopasowanie ciśnienia atmosferyczne­go
Wyszukiwanie czujników fal radiowych
MEMORY
Wskazanie automatycznie zapisanych war­tości minimalnych i maksymalnych temperatury, wil gotności powie­trza, punktu rosy (Dew Point), in
­deksu cieplnego (Heat Index), tem peratury odczu­walnej (Wind Chill) i prędkości wiatru
-
-
Loading...
+ 111 hidden pages