Ariston GENUS 27 Plus User Manual

403
Users
Manual
2
403
TABLE OF CONTENTS
1) GENERAL INFORMATION page 3
2) OPERATING INSTRUCTIONS pag e 4
4) USEFUL INFORMATION AND TROUBLESHOOTING page 10
IMPORTANT
Please read this manual carefully.
For additional information, please consult the “Installation and Servicing Instructions.”
Please ensure manuals provided are kept with the appliance so that they can be used by the end-
user, installer or our authorised engineer.
Dear Customer,
Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This User’s Manual provides detailed instructions and recommendations for proper installation, use and maintenance. Remember to keep this manual in a safe place for future reference i.e. by the gas meter. Your local MTS Servicing Centre is at your complete disposal for all requirements.
MTS (GB) Limited
Every attempt has been made to avoid errors of
any kind
in this User’s Manual, the Management
invites customers to inform
of any inaccuracies which they may find.
This will help to improve our service
The guarantee on this appliance is valid
for 12 months from the first day of
installation.
Repairs to the electric, hydraulic or gas circuits may be carried out only by your local authorised MTS Servicing Centre.
3
403
CONTROL PANEL
Legend
A) Ignition Lockout Reset Button/Safety (Overheat)Thermostat Reset B) Ignition Lockout L.E.D. C) Selector Knob for Summer/Winter/Flue Analysis Modes D) Low System Water Level L.E.D. E) Temperature Adjustment Knob for Domestic Hot Water F) Heating System Thermometer G) Safety (Overheat)Thermostat Intervention L.E.D. H) Adjustment Knob for Heating Temperature I) On/Off L.E.D. L) On/Off Switch O) Heating System Pressure Gauge
MTS (GB) Limited support the initiative.Your installer will give you, and show you how to use , a logbook which will give you important information about your boiler, and heating system. Please have this logbook to hand whenever you contact a service engineer or us.
All CORGI Registered Installers carry a CORGI ID card, and have a registration number. Both should be recorded in your boiler Logbook. You can check your installer is CORGI registered by calling CORGI direct on :- (01256) 372300.
This is a combined appliance for the production of central heating (C.H.) and domestic hot water (D.H.W.).This appliance must be used only for the purpose for which it is designed. The manufacturer declines all liability for damage caused by improper or negligent use. Do not allow children or inexperienced persons to use the appliance without supervision. If you smell gas in the room, do not turn on light switches, use the telephone or any other object which might cause sparks. Open doors and windows immediately to ventilate the room. Shut the gas mains tap (on the gas meter) or the valve of the gas cylinder and call your Gas Supplier immediately. If you are going away for a long period of time, remember to shut the mains gas tap or the gas cylinder valve.
Before any intervention within the boiler it is first necessary to cut off the electrical power supply by turning the external switch to “OFF”. This manual may be kept in the front panel of the boiler.
1. GENERAL INFORMATION
FR004A
4
403
CAUTION
Installation, start-up, adjustments and maintenance must be performed by a competent person only, in accordance with the current Gas Safety (Installation & Use) Regulations and the instructions provided. Improper installation may cause damage or injury to individuals, animals and personal property,for which the manufacturer will not be held liable. To ensure efficient and safe operation it is recommended that the boiler is serviced annually by a competent person. If it is known or suspected that a fault exists on the appliance, it must not be used until the fault has been corrected by a competent person.
HELPFUL SUGGESTIONS
To get the most out of your boiler, we have provided you with some useful advice on the proper use and maintenance:
- Periodically check the system pressure using the pressure guage “O”, make sure that the pressure at 1.5 bar (the blue part on the gauge) when the system is off and cool. The warning L.E.D. “D” will indicate if the pressure is below the minimum recommended value. Consult your installer for checking and refilling the system.
- The outer panels of the unit's case must only be cleaned with a damp cloth. Do not use abrasive cleaners.The Control panel can be wiped with either a damp or dry cloth. Spray polishes must not be used on the control panel surface or knobs.Care must be taken in preventing any liquid entering the appliance.
- If the water is exceptionally hard, install a water softener so that the efficiency of the unit remains the same over time, as this will consume less gas.
- To improve comfort and take full advantage of the heat produced by the boiler, it is recommended that an external thermostat be installed.
- If the boiler is not going to be used for an extended period of time, turn off the supply of electricity to the unit by pressing the On/Off switch
“L”.
- The green L.E.D.“I” will turn off.Then turn off the supply of gas to the unit itself.
- It is good practice to clean and service the appliance and central heating system every year.
- Call an Authorised Service Centre.
O
I
I
I
L
2. OPERATING INSTRUCTIONS
START-UP PROCEDURE LIGHTING
Before starting the unit, check the following:
· The water pressure on the pressure gauge “O”;
· That the gas cock and the inlet for domestic water are open.
These models are equipped with electronic ignition which utilises contact ionisation. To make the boiler operational, simply press the On/Off switch “L”. The green L.E.D.“I” will then turn on. At this point the boiler is ready for use: a centralised electronic control unit will automatically light the main burner when needed. If the burner
UT001A
UT008Aa
I
I
L
UT008Aa
5
403
C
H
°C
40 50 60 70 80
F
B
A
does not light within the pre-set safety time limit, the red “B” L.E.D .will light up. To reset the ignition system, the reset button “A” must be pressed. Should the system fail to light a second time, check to make sure that the gas cock is open. If the problem persists, contact one of our Authorised Service Centres for assistance.
WINTER AND SUMMER OPERATING MODES
The boiler is fitted with a selector knob “C” which allows you to switch between winter <>and summer <>and also heating only <
> operating modes and vice versa.When the knob is set to <
>, the boiler can serve the dual purpose of providing heat and/or hot
water for domestic use. The supply of hot water for domestic use always takes precedence over heating. When the knob is set to <>,the boiler cuts out the heating system and only provides hot water for domestic use (when needed).
TURNING ON THE CENTRAL HEATING
Installation without a room thermostat :
- Turn on the power supply to the boiler by pressing the On/Off switch “L”; the green L.E.D. “I” will then turn on;
- Turn the “C” selector knob to <> or < > (in this position no domestic hot water is produced);
- Regulate the temperature of the water in the boiler by turning the “H” knob.The temperature can vary between 42°C and about 82°C;
- Check the boiler temperature on the thermometer with the yellow L.E.D.s “F”. With this type of installation, the ambient temperature does not influence the operation of the boiler and the circulation pump always remains in operation.
UT008Ab
UT008Ac
C
UT008Ac
UT008Ad UT008Ae
I
I
L
UT008Aa
6
403
Installation with a room thermostat:
- Turn the “C” selector knob to < >;
- Turn on the power supply to the boiler by pressing the On/Off switch
”L”; the green L.E.D. will then turn on;
- Turn the thermostat knob “H” to the highest temperature setting.
- With this type of installation, the boiler is controlled by a room
thermostat
. Therefore, it runs until the ambient temperature has reached the
temperature setting on the thermostat. At that point, the main burner will turn off and the circulation pump will stop.
TURNING OFF THE CENTRAL HEATING
Installation without a room thermostat:
To turn off the heating, turn the “C” selector knob to < >.The boiler will still provide hot water for domestic use.
ADJUSTING THE HEA TING TEMPERA TURE
To economise on consumption while achieving the highest level of comfort, the temperature adjustment knob is designed with three different heating zones based on the temperature outside the home. Rotate the knob “H” as shown below.
PRODUCTION OF HOT WATER
FOR DOMESTIC USE
- Turn on the power to the boiler by pressing the On/Off switch “L”;
- Turn the “C” selector knob to <> or < > (in this position no central heating is produced);
- Turn the “E” knob to select the temperature for the hot water
(between 40°C and about 70°C).
ADJUSTING THE TEMPERA TURE OF
WATER FOR DOMESTIC USE
It is recommended that the temperature for the hot water should not be set to high temperatures and then mixed with cold water. Setting the thermostat to medium temperatures is preferable
(see figure)
.
m
i
n
m
a
x
m
i
n
m
a
x
m
i
n
m
a
x
From +5°C to +15°C
Lower than -5°C
From +5°C to -5°C
H
H
UT008Af
C
UT008Ag
m
i
n
m
a
x
E
UT008Ai
m
i
n
m
a
x
E
UT008Al
UT008Ah
7
403
Operating the time switch
The step marked with the symbol “”are necessary to carry out a switching program.
Preparing for Operation
Activate the “Res” switch (=RESET) to reset the time switch to its default setting (activate using a pencil or similar pointed instrument).Do this:
- every time you wish to “reset”the time switch
- to erase all switching times and the current time of day. After approximately two seconds the following display appears:
Enter current time and weekday
- Keep the “”key pressed down During the summer time period press the +/- 1h key once. Enter the hour using the “h” key Enter the minutes using the “m” key Enter the day using the “Day” key
1 = “Monday”..............7 = Sunday
- Release the “”key.
3.TIME CLOCK
SHUTDOWN PROCEDURE
To turn off the main burner, simply press the On/Off switch “L”; the green L.E.D.“I” will also turn off. As a precautionary measure, it is recommended that the gas cock located on the bottom of the boiler be turned off as well.
I
I
L
UT008Aa
UT008Am
Input
Manual switch
Summer and winter time setting
Enter the hours
h
Week­days
m
flash Enter
minutes
Enter
switching
times
Imput
time
Reset
.
g
o
r
P
Day
Enter
weekday/s
8
403
Automatic Manual Continuous
Entering the switching times
You have 20 memory Iocations available.Each switching time takes up one memory location. Keep pressing the “Prog”key until a free memory location is shown in the display “– –:– –”.
Programme ON or OFF with the “”key: “”= OFF; “”= ON
Enter the hour using “h” Enter the minutes using “m” If a switching command is to be carried out every day (1 2 3 4 5 6 7)
then store using the “”key, otherwise select the day(s) it is to be carried out by using the “Day”key.
When the day seIection is left bIank, the programmed switching instruction operates at the same time every day 1 2 3 4 5 6 = Monday – Saturday 1 2 3 4 5 = Monday – Friday 6 7 =Saturday – Sunday
Selection of single days: 1 = Mon............... 2 =Tues.
Save the switching time with the “”key. The time switch enters the automatic operating mode and displays the current time of day. Begin any further entry of a switching time with the “Prog” switch. If your entry is incomplete, the segments not yet selected will blink in the display. After programming is completed, and y ou return the time clock
to the current time display with the “”key, the time clock will not activate any switching instruction required for the current time .Y ou ma y
need to manually select the desired switching state with the “” key.Thereafter, as the unit encounters further switching instructions in the memory in real time, it will correctly activate all subsequent switching instructions.
Manual Override Switch “”
With the “”you can change the current setting at any time. The switching program already entered is not altered.
UT008An
Operation Operation Operation
= ON = ON = Continuously ON
= OFF = OFF = Continuously OFF
The switching If the current You can only times corres- switching mode is return to automatic pond to the changed manually, mode from the program the next switching continuously-ON entered. time will be and continuously-
carried out auto- OFF switching matically again modes by according to the pressing the " " entered switching key. program.
Reading the programmed switching times
Pressing the “Prog” key displays the programmed switching times until the first free memory location appears in the display “– – : – –”.
If you now press the “Prog” key once again, the number of free memory Iocations will be displayed, e.g. “FR
1188
”. If all memory locations are
occupied, the display “FR
0000
” appears.
Changing the programmed switching times
Press the “Prog”key repeatedly until the switching time you want to change is displayed. You can now enter the new data. See point “Entering the
switching times”.
Notes on storing switching times:
If you end your entry of the switching times by pressing the “Prog” key, then the switching time you have entered will be stored and the next memory location displayed. Entry of fur ther switching times is also carried out as described in point 4.3.
In addition, a complete switching command is stored automatically after around 90 seconds provided no other key is pressed.The time switch then enters the automatic operating mode and displays the current time again.
Deleting individual switching times
Press the “Prog” key repeatedly until the switching time you wish to delete is shown in the display. Then set to “– –” using the “h” or “m” key and keep
the “”key pressed down for around 3 seconds.The switching time is now erased and the current time is displayed.
AM / PM time display
If you press the “+/-1h” and “h” keys at the same time, the time display switches into the AM/PM mode (mostly used in English-speaking countries).
Technical data
Connection see unit imprint Switching capacity see unit imprint Ambient temperature -10°C to +55°C Running reserve 5 h at + 20°C Memory Iocations 20 Shortest switching time 1 min. Programmable every minute
9
403
10
403
4. USEFUL INFORMATION AND TROUBLESHOO TING
B
A
G
BOILER SHUTDOWN
The boiler unit is equipped with safety devices which intervene in certain situations to shutdown the boiler. Some of these situations are signalled by the unit and can be corrected by the user.
SHUTDOWN DUE TO THE FAILURE OF THE BURNER TO LIGHT AUTOMATICALLY
This anomaly is indicated by the red “B” L.E.D. To reset the unit, press and then release the “A” button. At this point, the electronic ignition system will attempt to light the burner again. If lighting failure occurs repeatedly, it is recommended that you contact one of our Authorised Service Centres.
SHUTDOWN DUE TO OVERHEATING
This anomaly is signalled by the red “G” L.E.D. The boiler shuts off because the safety thermostat detected that the boiler temperature has reached the temperature limit. To reset the unit, wait until the boiler has cooled and then press the “A” button. If the safety thermostat shuts off the unit on a frequent basis, contact one of our Authorised Service Centres for assistance.
SHUTDOWN DUE TO INSUFFICIENT
WATER CIRCULATION
This anomaly is indicated by the red “D” L.E.D. One of the possible causes of this shutdown situation could be the lack of water in the boiler or water circulation failure in the primary heating circuit. Check the system pressure on the pressure gauge “O”and, if it is less than 0.5 bar, consult your installer f or chec king and refilling the system.
Then reset the unit by turning the boiler off and then back on with the On/Off button “L”. If this situation persists, contact one of our Authorised Service Centres.
I
I
L
UT008Aa
O
UT001A
D
UT008Ap
A
UT008Ab
UT008Ao
11
403
FLUE TEST FEA TURE
(only for authorised personnel)
The “C”
Summer/Winter/Flue T est
selector knob can be set to <> to bypass temperature adjustment on the heating circuit for the purpose of analysing the fumes produced by combustion. To access this mode, open a water tap or taps so that the flow rate is no less than 8 litres per minute. Then press the “C” selector knob in and turn it from <> or <> to the <>.
WARNING!
The flue test feature eliminates the slow-light feature.
This mode must only be selected by a qualified service engineer.