A. O. Smith CR-140-AP User Manual

Page 1
Solar Commercial Pump Stations
A. O. Smith integrated commercial solar pump stations maximize performance, savings, and serviceability. All-in-one factory assembled heat transfer station simplifies system design and sizing; saves space and reduces installation costs. Five pump stations available with single wall or double wall heat exchangers capable of transferring 160,000 to 800,000 Btu/hr of heat energy captured from the sun. Pump stations can be combined to supply an unlimited number of collectors.
Designed for commercial and industrial applications including hospitals and healthcare facilities, government and military buildings, hotels and resorts, universities, schools and industrial process water.
FEATURES
I Factory assembled fully integrated pump stations – consistent intuitive design.
I Redundant solar and water loop circulation pumps - self-lubricating pumps with
isolation flanges - allows continued pump station operation while servicing individual pumps.
I Stainless steel (316L) flat plate heat exchangers - single wall or double wall.
I Fully programmable electronic solar control with LCD display that monitors and
records system data with graphical view for temperature, energy and other operational data.
I Solar control continually monitors system operation and provides alerts for system
errors such as shorted or open temperature sensors, pump failure or loss of flow.
I SD memory card slot on solar control - saves and transfers configuration settings
from one pump station to another - provides permanent storage for energy data.
I Web module for online monitoring via Internet or local intranets.
I Standard energy metering via onboard solar control with factory installed surface mount
temperature sensors - energy data logging, tracks performance and savings.
I Optional MID certified energy meter (part number 9008131005) with well mounted
temperature sensors - certified validation of solar contribution required for Renewable Energy Credits (RECs), Power Purchase Agreements (PPAs) and other incentives.
I Pulse type electronic flow meter.
I Surface mount temperature sensors in solar and water loop – monitored by solar control
to start/stop circulation pumps and for standard energy metering.
I Temperature sensor wells (4) are provided at solar and water loop connections to heat
exchangers - for optional energy meter or field supplied temperature sensors.
I Fluid balancing valves for precise flow control.
I Full port isolation ball valves at solar and water loop connections.
I Air stripper with automatic air vent - purges air from solar loop.
I Brass body wye strainer in water loop protects pump station components from debris.
I Solar and water loop pressure relief valves.
I Removable access panels on all four sides – allows ease of servicing.
OPTIONAL MID CERTIFIED
ENERGY METER
PN 9008131005
These pump stations are
eligible for a 30% federal tax
credit when installed as part of
a complete commercial solar
thermal hot water system.
Page 1 of 4
AOSQE16000
Page 2
Solar Commercial Pump Stations
D
H
J
I
C
A
B
GE
F
+
><
-
T1
kBTU
kBTU/h
P1
P2
T2
T1 F T2 F
P1 % P2 %
TOP TOP
FRONT RIGHT SIDE
From
Collectors
From
Storage Tank
To
Storage Tank
To
Collectors
160, 320, 480 KBTU/HR PUMP STATIONS
PART
NUMBER
9008121005 SingleWall
9008122005 DoubleWall
9008123005 SingleWall
9008124005 DoubleWall
9008125005 SingleWall
9008126005 DoubleWall
All dimensions are in inches Maximum system working pressures; solar loop 75 psi, water loop 150 psi. Maximum heat exchanger pressure ratings; single wall 450 psi, double wall 232 psi. Solar loop and water loop connections are female NPT.
HEAT
EXCHANGER
SW / DW
A B C D E F G H I J
57 52 3/4 52 3/4 6 3/4 16 1/2 42 15 3/4 7 3/4 12 6 1 1/2 650 4
62 52 3/4 52 3/4 6 16 3/4 42 15 1/2 6 3/4 11 1/2 5 3/4 2 675 6.5
63 1/4 52 3/4 52 3/4 6 1/2 16 1/2 42 16 7 1/4 11 1/4 5 3/4 2 1/2 800 9.5
SOLAR/WATER
LOOP IN/OUT
CONNECTIONS
DRY
WEIGHT
(lbs.)
CAPACITY
(GALLONS)
Power requirements: 120 VAC, single phase, 15 amp breaker.
HEAT
EXCHANGER
SW / DW
PART
NUMBER
9008121005 Single Wall 9008122005 Double Wall 9008123005 Single Wall 9008124005 Double Wall 9008125005 Single Wall 9008126005 Double Wall
MAX COLLECTOR
APERTURE AREA
(FT2)
741 32 26 20 160,000
1,481 64 50 40 320,000
2,222 96 76 60 480,000
MAX NUMBER
CR-110-AP
COLLECTORS
(3.5' X 7')
MAX NUMBER
CR-130-AP
COLLECTORS
(4' X 8')
MAX NUMBER
CR-140-AP
COLLECTORS
(4' X 10')
ENERGY
RATING BTU/HR
A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Page 2 of 4
www.hotwater.com AOSQE16000
Page 3
+
><
-
T1
kBTU
kBTU/h
P1
P2
T2
T1 F T2 F
P1 % P2 %
C
TOP
FRONT SIDERIGHT
A
B
E
H
G
D
F
I
From
Collectors
From
Storage Tank
To
Storage Tank
To
Collectors
640, 800 KBTU/HR PUMP STATIONS
Solar Commercial Pump Stations
PART
NUMBER
9008127005 Single Wall
HEAT
EXCHANGER
SW / DW
9008128005 Double Wall
9008129005 Single Wall
9008130005 Double Wall
All dimensions are in inches Maximum system working pressures; solar loop 75 psi, water loop 150 psi.
A B C D E F G H I
78 1/2 54 3/4 78 1/2 10 1/4 23 3/4 5 1/4 17 8 1/4 4 1/2 3 1455 21
LOOP IN/OUT
CONNECTIONS
SOLAR/WATER
DRY
WEIGHT
(lbs.)
78 1/2 54 3/4 78 1/2 10 1/4 23 3/4 5 1/4 17 8 1/4 4 1/2 3 1465 22
Maximum heat exchanger pressure ratings; single wall 450 psi, double wall 232 psi. Solar loop and water loop connections are female NPT. Power requirements: 120 VAC, single phase, 15 amp breaker 640,000 Btu/hr model, 25 amp breaker 800,000 Btu/hr model.
HEAT
EXCHANGER
SW / DW
PART
NUMBER
9008127005 Single Wall
9008128005 Double Wall
9008129005 Single Wall
9008130005 Double Wall
MAX COLLECTOR
APERTURE AREA (FT
2
)
CR-110-AP
COLLECTORS
(3.5' X 7')
2,962 128 100 80 640,000
3,703 160 126 100 800,000
MAX NUMBER
MAX NUMBER
CR-130-AP
COLLECTORS
(4' X 8')
MAX NUMBER
CR-140-AP
COLLECTORS
(4' X 10')
ENERGY
RATING BTU/HR
A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
www.hotwater.com AOSQE16000
CAPACITY
(GALLONS)
Page 3 of 4
Page 4
Solar Commercial Pump Stations
Pressure
Relief Valve
Pressure
Relief Valve
Temperature
Pressure Gauge
Fill
Valve
T3, T4, T5 - Factory Installed
Surface Mount Temperature Sensors
Temperature
Sensor Wells (4)
Expansion Tank
Connection
Heat Exchanger(s)
Pulse
Flow Meter
Check
Valve
Union
UnionUnion
Union
Solar Loop Pumps
With Isolation Flanges
Water Loop Pumps
With Isolation Flanges
Flow
Setter
Flow
Setter
Auto Air
Vent
Air Separator
Drain Valve
Service Ball Valve
Service
Ball Valve
Wye Strainer
Solar Loop
Solar Control
Enclosure
Water Loop
From
Collectors
From
Storage TankToStorage Tank
To
Collectors
(4) Isolation Ball Valves
T4
T3
T5
T6
P1 P2
+
><
-
T1
kBTU
kBTU/h
P1
P2
T2
T1 °F T2 °F
P1 % P2 %
P1 P2 T1 T2 T3
T4 T5
T6 GDS1 GDS2
TERMINAL DEVICE
P1 Solar LoopPum ps P2 Water Loop Pumps T1 Temp Sensor Collector T2 Temp Sensor Storage Tank T3 Temp Sens or T4 Temp Sens or T5 Temp Sens or T6 Pulse Flow Meter GDS1 VFS Flow or RFS Pressure Sensor GDS2 RPS Press ure Sensor
PIPING AND INSTRUMENTATION DIAGRAM
www.hotwater.com AOSQE16000
LIMITED WARRANTY OUTLINE
Factory installed plumbing and piping components such as pumps, heat exchangers, strainers and valves are warrantied for a period of 5 years from the date of installation. Electronic components such as the solar control, web module, pulse flow meter and optional Btu meter are warrantied for a period of 3 years from the date of installation. Warranty does not include labor or shipping.
NOTE: THIS OUTLINE IS NOT A WARRANTY. For complete information, consult the written warranty or A. O. Smith. Warranty does not apply to product installed outside of the United States of America or its territorial possessions and Canada.
SUGGESTED SPECIFICATION
Commercial solar pump station(s) to be A. O. Smith part number _________________. Pump station is a fully integrated factory assembled heat transfer appliance with a maximum heating capacity of ____________ Btu/hr. Pump station water loop pressure rating of 150 psi, rated for120VAC single phase power.
Thepumpstation hasredundant (2)solar and (2) waterloop circulation pumps. Circulation pumpsare self-lubricatingandfitted with integral isolation flangestoallow continued pump stationoperation duringservicing of individual pumps.The pump station is equipped with factoryinstalled (single, double) __________wall 316L stainless steel flat plate heat exchanger(s) with a maximum working pressure ratingof(450, 232) ________ psi. Heat exchangers are installed with pipe unions on all fluid connections to provideease of removal for inspection and service.
The pump station has a fully programmable electronic solar system control with LCD display that continually monitors and records system performance and provides alerts for loss of flow, pump failure or temperature sensor failure.The pump station has factory installed temperature sensors and an electronic (pulse type) flow meter in the water loop to allow the solar control to display and calculate actual energy (Btu) production. The pump station includes a web module for online monitoring via the Internet and on local intranets.
The pump station has adjustable fluid balancing valves installed on both the solar loop and water loop for precise flow adjustment.The pump station has four factory installed full port isolation ball valves at the external connections for the solar and water loops.The pump station incorporates a factory installed air stripper in the solar loop with an automaticairventtopurgeair. The pump station includesbrass body wye strainer installed in the water loop to protect pumpstation componentsfromdebris.The pump station utilizes factory installed quarter turn brass body fill and drain valves.The pump station includes factory installed 75 psi solar loop and 150 psi water loop pressure relief valves. The pump station includes a connection for a field supplied solar loop expansion tank. Pump station to include factory installed Loadbreak Switch to secure power supply and removable panels on all sides for safety, ease of maintenance and servicing.
A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
© 2011 A. O. Smith Corporation
Page 4 of 4