Andover Controls Continuum Guide

×NTINUUM
ª
NetController CPU Module
The
Continuum
NetController is the high-powered Central Processing Unit (CPU) module and
• Powerful, Modular CPU Board
for Monitoring and Control
of Both
and
Controllers
• High-Speed Networking—
4 Million Nodes on Ethernet
• Four Programmable Comm. Ports
for Flexible Interconnect and
Third-Party Communications
• Programmable Battery Backup
Provides Choice of Shutdown
Options
• Flash EPROM for Easy On-Line
Software Updates
Plain English
Simplifies Programming
• DIN Rail Mounting and Slide-
Together Connectors for Easy
Installation
• Backward Compatible with
Infinity
Continuum
Infinity
Hardware
I/O Modules
Infinet Distributed
®
Language
network manager for the Andover Controls
Continuum
intelligent building system. With its 8
Mb DRAM, 4 Mb flash EPROM, math co-processor, and four programmable communications
ports, including an interface to
Infinity
Continuum
NetController provides a total solution for facility-wide network communications and
information management. A lower-cost version of the NetController is also available with
4Mb DRAM, 2 Mb flash EPROM, and no math co-processor.
HIGH-SPEED COMMUNICAHIGH-SPEED COMMUNICA
HIGH-SPEED COMMUNICA
HIGH-SPEED COMMUNICAHIGH-SPEED COMMUNICA
The NetController acts as the system coordinator, providing integrated global control and monitoring, history
logging, and local and remote alarming for both the
that control your individual building services—heating, ventilating, air conditioning, lighting, access control,
smoke control, and more. The NetController communicates with the
communications and a choice of RS-485 or free topology bus media.
An optional Ethernet port also allows the NetController to communicate with other NetControllers and
Workstations over a high-speed 10Mb Ethernet Local Area Network (LAN) using the TCP/IP protocol.
workstations are capable of communicating with up to 4 millions nodes on Ethernet. Two different Ethernet
interfaces are available—you can choose either a 10BASE-2 (thin coax)
or 10BASE-T (twisted pair) cable media.
NetController’s flash EPROM allows you to download software revisions over Ethernet using a
workstation. This flash memory feature eliminates the need to perform EPROM change-outs in the field.
SERIAL COMMUNICASERIAL COMMUNICA
SERIAL COMMUNICA
SERIAL COMMUNICASERIAL COMMUNICA
NetController’s four programmable communications ports can be configured as either an RS-232 or an RS-485
interface to modems, printers, third-party devices, and up to two
Andover Controls has developed an extensive library of third-party software interfaces, including controls for
chiller panels, fire alarm systems, emergency generator systems, bar code readers, elevator controls,
videomatrix switchers, and more.
PLAIN ENGLISHPLAIN ENGLISH
PLAIN ENGLISH
PLAIN ENGLISHPLAIN ENGLISH
The
Continuum
powerful Andover Controls
Continuum
using the
Infinity
, one
® PROGRAMMING® PROGRAMMING
® PROGRAMMING
® PROGRAMMING® PROGRAMMING
NetController can be configured to meet the exact requirements of your application using the
Workstation. The program is then stored in, and executed by, the NetController. Just as with
single
language is used system-wide.
TIONSTIONS
TIONS
TIONSTIONS
TIONSTIONS
TIONS
TIONSTIONS
Plain English
Continuum
programming language. Programs are entered into NetController
I/O modules and the RS-485 Infinet controllers
Continuum
Infinity
I/O modules via LON
Continuum
Continuum
Continuum
Infinet field controller networks.
Downloaded from - http://www.guardianalarms.net
SOFTWARE CAPABILITIESSOFTWARE CAPABILITIES
SOFTWARE CAPABILITIES
SOFTWARE CAPABILITIESSOFTWARE CAPABILITIES
The dynamic memory of the
alarming, reporting and data logging. Our object-oriented
easy operation and programming. In addition,
Continuum
NetController can be allocated for any combination of programs, scheduling,
Plain English
Plain English
‘s pre-defined and customized functions and powerful
language with intuitive keywords provides
math capabilities reduce programming time.
OPTIONAL AUTO-BAUD MODEMOPTIONAL AUTO-BAUD MODEM
OPTIONAL AUTO-BAUD MODEM
OPTIONAL AUTO-BAUD MODEMOPTIONAL AUTO-BAUD MODEM
The optional Andover Controls
Continuum
PPP modem allows NetController to communicate and exchange data over
standard voice grade telephone lines with speeds up to 14,4K baud. The modem has built-in data compression and error-
correction protocols, auto-dial/auto-answer capabilities, and is UPS-supported.
DIMENSION DRAWING
UPS OPERAUPS OPERA
UPS OPERA
UPS OPERAUPS OPERA
The
Continuum
TIONTION
TION
TIONTION
NetController incorporates software programmable battery backup that reduces or eliminates the
impact of power failure. In powerfail mode, the NetController CPU can turn off I/O power to extend battery life and
support modem and network operation for up to four hours. In addition, NetController can go into a low-power
mode in which only the DRAM and real-time clock are powered for up to 72 hours.
MODULAR DESIGN FOR SLIDE-TOGETHER CONNECTIONMODULAR DESIGN FOR SLIDE-TOGETHER CONNECTION
MODULAR DESIGN FOR SLIDE-TOGETHER CONNECTION
MODULAR DESIGN FOR SLIDE-TOGETHER CONNECTIONMODULAR DESIGN FOR SLIDE-TOGETHER CONNECTION
NetController features a sleek, lightweight casing designed for natural convection cooling. Built-in connectors on
either side of the NetController module allow power transmission from the power supply module and communica-
tion signals to the
Continuum
I/O modules to feed through easy slide-together connections. Built-in quick-release
fasteners at the back of the module are provided for DIN rail mounting—no tools required. These fasteners also snap into
a locked position for panel mounting. The NetController module is designed for mounting in an optional NEMA 1-sytle
Continuum
enclosure. (See the
Continuum Enclosure and Display Module System
data sheet.)
2.5
6.7
9.0
SPECIFICATIONS
ELECTRICALELECTRICAL
ELECTRICAL
ELECTRICALELECTRICAL
Power Consumption: 10 watts at 24VDC max.; provided by
Continuum
power supply module.
Overload Protection: 3A resettable fuse with transient voltage suppressor (TVS) and reverse polarity protection.
Real Time Clock: Battery-backed by UPS
MECHANICALMECHANICAL
MECHANICAL
MECHANICALMECHANICAL
Operating Environment: 32 to 120°F, (0 to 49°C), 10 to 95%RH (non-condensing)
Size: 9.0”W x 6.7”H x 2.5”D (228.7 x 170.2 x 63.5mm)
Weight: 1.6 lbs (0.73kg)
Mounting: Mount on DIN rail or wall-mount using attached fasteners.
Continuum
NEMA 1-style
enclosure available.
BABA
TTERYTTERY
BA
TTERY
BABA
TTERYTTERY
Battery Backup: Two 12V 7.0AHr sealed rechargeable batteries on the
Continuum
power supply provides 60 minutes @ 35 watts power consumption full UPS (CPU plus I/O power); 4 hours CPU module only (including modem and network interface) with no I/O; and 72 hours DRAM and real-time clock. Expandable by use of greater amp-hour batteries.
COMMUNICACOMMUNICA
COMMUNICA
COMMUNICACOMMUNICA
TIONSTIONS
TIONS
TIONSTIONS
Comm. Error Checking: International Standard CRC 16
Ethernet LAN Interface: Supports two cable media interfaces: 10BASE-T or 10BASE-2
Bus Length: 10BASE-T: 327 ft (100m) standard between 2 nodes using 10BASE-T unshielded
twisted pair cable. Standard Ethernet repeaters allow for longer distances.
10BASE-2: 606 ft (185m) standard for 30 nodes using 10BASE-2 thin coaxial cable.
Standard Ethernet repeaters allow for longer distances.
Serial Comm. Interface: Four programmable RS-232/485 ports, software configurable as printer, modem, third-party
system, or TankNet. Infinet can be configured on Ports 1 and 2. Port 1: RS-485/232 Port 2: RS-485 Port 3: RS-232/Modem Port 4: RS-485
Serial Comm. Speed: 300 to 19.2K baud selectable for Infinet and 14.4K baud for modem
Infinet Bus Length: 4,000 ft. (1,220m) standard for Infinet using approved shielded, twisted pair, low
capacitance cable. InfiLink module allows extension to longer distances.
I/O Communications Interface:
LON communications. Choice of bus media, RS-485 or FTT-10
RS-485: Communications Speed: 39k baud
Bus Length: 2,000 ft. (610m). Repeater required for longer distance or after
every 32 nodes.
Bus Media: Shielded, twisted pair cable. 120 termination required at
both ends of the LON network (when modules are mounted remotely).
FTT-10: Communications Speed: 78k baud
Bus Length: Up to 8858 ft. (2700m) – bus topology
Up to 1640 ft (500m) – free topology Repeater required for longer distances.
Bus Media: Refer to LON free topology documentation
CONNECTIONSCONNECTIONS
CONNECTIONS
CONNECTIONSCONNECTIONS
Power: 5-position plug-in connector on left side of module for direct connection to
power supply module.
Ethernet: Female BNC coax connector for Ethernet 10BASE-2 or
RJ-45 connector for Ethernet 10BASE-T
Infinet, TankNet: Removable terminal block (Requires external +26 volts for TankNet.)
Printer: RJ-45
Continuum
Modem: RJ-11 connector
I/OCommunications: 5-position plug-in connector on right side of module for direct connection of up to 64 I/O
modules.
USER LEDS/SWITCHESUSER LEDS/SWITCHES
USER LEDS/SWITCHES
USER LEDS/SWITCHESUSER LEDS/SWITCHES
STATUS INDICATOR LEDS
POWER NetController Power is ON CPU NetController Active SCAN NetController Scanner ON ERROR NetController Error
COMM1 TD Comm. Port 1 Transmit On-Line COMM1 RD Comm. Port 1 Receive Data
COMM2 TD Comm. Port 2 Transmit On-Line COMM2 RD Comm. Port 2 Receive Data
COMM3 TD Comm. Port 3 Transmit Data COMM3 RD Comm. Port 3 Receive Data
COMM4 TD Comm. Port 4 Transmit On-Line COMM4 RD Comm. Port 4 Receive Data
MODEM DCD Data Carrier Detect MODEM DTR Data Terminal Ready MODEM Selected Indicates the MODEM is selected (Comm Port 3 is shared—RS-232 and MODEM)
I/O Bus On-Line Indicates the LON I/O Bus is On-Line
ETHERNET: TD ETHERNET Transmit Data
RD ETHERNET Receive Data COL ETHERNET Collision LINK ETHERNET Link POL ETHERNET Polarity
PUSH BUTTON SWITCHES:
Clear Memory RESET/Clear Memory
MODEM RS-232 Override Selects between the MODEM and RS-232C (Comm 3)
GENERALGENERAL
GENERAL
GENERALGENERAL
Microprocessor: 68ECO20 running at 24 MHz with 68882 Floating Point Math Co-Processor (8Mb
model only)
Memory: DRAM: 8Mb or 4Mb
Flash EPROM: 4Mb or 2 Mb
AGENCY LISTINGSAGENCY LISTINGS
AGENCY LISTINGS
AGENCY LISTINGSAGENCY LISTINGS
UL/CUL 916, FCC, CE
OPTIONSOPTIONS
OPTIONS
OPTIONSOPTIONS
Ethernet (TCP/IP) Module, 10BASE-2 (Coax)
Ethernet (TCP/IP) Module, 10BASE-T (Twisted Pair)
Third-party Interface Support (up to 3 commports)
14,4K Baud PPP Modem (UPS Supported)
Andover Controls Corporation World Headquarters
300 Brickstone Square • Andover, Massachusetts 01810 USA Tel: 978 470 0555 • Fax: 978 470 0946 http://www.andovercontrols.com
Andover Controls Ltd.
Smisby Road • Ashby-de-la-Zouch • Leicestershire LE65 2UG, England Tel: 01530 417733 • Fax: 01530 415436
Andover Control GmbH
Am Seerhein 8 • D-78467 Konstanz, Germany Tel: 07531 99370 • Fax: 07531 993710
Andover Control S.A.
93 Avenue de Fontainebleau • 94270 Le Kremlin-Bicetre, France Tel: 49 60 63 63 • Fax: 49 60 62 71
Andover Controls Corporation
707 Chinachem Golden Plaza • 77 Mody Road, Tsimshatsui East • Kowloon, Hong Kong Tel: 2739 5497 • Fax: 2739 7350
Copyright 1998, Andover Controls Corporation. Data subject to change without notice. All brand names, trademarks and registered trademarks are the property of their respective holders.
Andover Product Installation Guides
Consult U.S. Patent #4591967 #DS-CPU-A
for exact installation instructions and specifications.
Loading...