AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design and
manufacture of precision, programmable power supplies for R&D, test and measurement, process control,
power bus simulation and power conditioning applications across diverse industrial segments. From bench
top supplies to rack-mounted industrial power subsystems, AMETEK Programmable Power is the proud
manufacturer of Elgar, Sorensen, California Instruments and Power Ten brand power supplies.
AMETEK, Inc. is a leading global manufacturer of electronic instruments and electromechanical devices
with annualized sales of $2.5 billion. The Company has over 11,000 colleagues working at more than 80
manufacturing facilities and more than 80 sales and service centers in the United States and around the
world.
Trademarks
AMETEK is a registered trademark of AMETEK, Inc.
Other trademarks, registered trademarks, and product names are the property of their respective owners
and are used herein for identification purposes only.
Notice of Copyright
DLM-E 3kW & 4kW Series Power Supplies Operation Manual
UNLESS SPECIFICALLY AGREED TO IN WRITING, AMETEK PROGRAMMABLE POWER, INC.
(“AMETEK”):
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR
OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES,
WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT
OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT
THE USER’S RISK, AND
(c) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH
STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY
CANNOT BE GUARANTEED. APPROVED AMETEK CONTENT IS CONTAINED WITH THE ENGLISH
LANGUAGE VERSION, WHICH IS POSTED AT WWW.PROGRAMMABLEPOWER.COM.
Date and Revision
January 2011Revision E
Part Number
M362000-01
Contact Information
Telephone: 800 733 5427 (toll free in North America)
858 450 0085 (direct)
Before applying power to the system, verify that your product is configured properly for your particular
application.
WARNING
Hazardous voltages may be present when covers are removed. Qualified
personnel must use extreme caution when servicing this equipment.
Circuit boards, test points, and output voltages also may be floating above
(below) chassis ground.
The equipment used contains ESD sensitive parts. When installing
WARNING
Only qualified personnel who deal with attendant hazards in power supplies, are allowed to perform installation
and servicing.
Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis.
Similarly, other power ground lines including those to application and maintenance equipment must be
grounded properly for both personnel and equipment safety.
Always ensure that facility AC input power is de-energized prior to connecting or disconnecting any cable.
In normal operation, the operator does not have access to hazardous voltages within the chassis. However,
depending on the user’s application configuration, HIGH VOLTAGES HAZARDOUS TO HUMAN SAFETY
may be normally generated on the output terminals. The customer/user must ensure that the output power
lines are labeled properly as to the safety hazards and that any inadvertent contact with hazardous voltages is
eliminated.
Guard against risks of electrical shock during open cover checks by not touching any portion of the electrical
circuits. Even when power is off, capacitors may retain an electrical charge. Use safety glasses during open
cover checks to avoid personal injury by any sudden component failure.
Neither AMETEK Programmable Power Inc., San Diego, California, USA, nor any of the subsidiary sales
organizations can accept any responsibility for personnel, material or inconsequential injury, loss or damage
that results from improper use of the equipment and accessories.
Product Family: DLM-E 3kW & 4kW Series Power Supplies
Warranty Period: Five Years
WARRANTY TERMS
AMETEK Programmable Power, Inc. (“AMETEK”), provides this written warranty covering the Product
stated above, and if the Buyer discovers and notifies AMETEK in writing of any defect in material or
workmanship within the applicable warranty period stated above, then AMETEK may, at its option: repair or
replace the Product; or issue a credit note for the defective Product; or provide the Buyer with replacement
parts for the Product.
The Buyer will, at its expense, return the defective Product or parts thereof to AMETEK in accordance with
the return procedure specified below. AMETEK will, at its expense, deliver the repaired or replaced Product
or parts to the Buyer. Any warranty of AMETEK will not apply if the Buyer is in default under the Purchase
Order Agreement or where the Product or any part thereof:
is damaged by misuse, accident, negligence or failure to maintain the same as specified or required
by AMETEK;
is damaged by modifications, alterations or attachments thereto which are not authorized by
AMETEK;
is installed or operated contrary to the instructions of AMETEK;
is opened, modified or disassembled in any way without AMETEK’s consent; or
is used in combination with items, articles or materials not authorized by AMETEK.
The Buyer may not assert any claim that the Products are not in conformity with any warranty until the
Buyer has made all payments to AMETEK provided for in the Purchase Order Agreement.
PRODUCT RETURN PROCEDURE
Request a Return Material Authorization (RMA) number from the repair facility (must be done in the
country in which it was purchased):
In the USA, contact the AMETEK Repair Department prior to the return of the product to AMETEK for
repair:
Telephone: 800-733-5427, ext. 2295 or ext. 2463 (toll free North America)
858-450-0085, ext. 2295 or ext. 2463 (direct)
Outside the United States, contact the nearest Authorized Service Center (ASC). A full listing can
be found either through your local distributor or our website, www.programmablepower.com, by
clicking Support and going to the Service Centers tab.
When requesting an RMA, have the following information ready:
Model number
Serial number
Description of the problem
NOTE: Unauthorized returns will not be accepted and will be returned at the shipper’s expense.
NOTE: A returned product found upon inspection by AMETEK, to be in specification is subject to an
evaluation fee and applicable freight charges.
M362000-01 Rev E
xi
This page intentionally left blank.
xii M362000-01 Rev E
ABOUT THIS MANUAL
This manual has been written expressly for AMETEK’s Sorensen brand DLM–E 3kW and 4kW series of
power supplies, which have been designed to meet the 1997 Low Voltage and Electromagnetic Compatibility
Directive Requirements of the European Community, except DLM16-185E and DLM22-180E models.
These models have been designed and tested to meet the Electromagnetic Compatibility directive
(European Council directive 2004/108/EC, generally referred to as the EMC directive) and to the
requirements of the Low Voltage directive (European Councel directive 2006/95/EC, 93/68/EEC, dated 22
July 1993). In addition, these models have been found to be compliant with FCC 47 CFR Part 15, Subpart B,
107(e) Class A, 109(g) Class A.
Since the goal of the Low Voltage Directive is to ensure the safety of the equipment operator, universal
graphic symbols (see Safety Notice above) have been used both on the unit itself and in this manual to warn
the operator of potentially hazardous situations.
M362000-01 Rev E
xiii
This page intentionally left blank.
xiv M362000-01 Rev E
CONTENTS
About AMETEK ............................................................................................................. vii
Important Safety Instructions .......................................................................................... ix
Warranty Terms .............................................................................................................. xi
About This Manual ........................................................................................................ xiii
SECTION 1 FEATURES AND SPECIFICATIONS ................................. 1-1
Figure 4–2. Locating Jumpers, Switch, and Connector .................................................... 4-4
Figure 4–3. Programming Output Voltage, Current Limit and OVP with REM/LOC Switch4-7
Figure 4–4. Programming Output Voltage with a 0–5 VDC or 0–10 VDC Source ............ 4-8
Figure 4–5. Programming Output Voltage with a 0–5k Ohm Resistance ......................... 4-9
Figure 4–6. Programming Output Current Limit with a 0–5 VDC or 0–10 VDC Source ...4-10
Figure 4–7. Programming Output Current Limit with a 0–5k Ohm Resistance ................4-11
Figure 4–8. Programming Output Voltage Remotely, Local Control of Current Limit/OVP4-12
Figure 4–9. Programming Output Current Remotely, Local Control of Voltage Limit/OVP4-13
Figure 4–10. Remote Programming of OVP with a 0–5 VDC or 0–10 VDC External Voltage
The DLM–E Series 3000 and 4000 watt power supplies are designed to provide highly stable,
continuously variable output voltage and current for a broad range of development, system and
burn–in applications. Model numbers for this series are designated by the DLM prefix, followed
by the output voltage and current ratings. For example, the model number DLM40–100E
indicates that the unit is rated at 0–40 VDC and 0–100 amps while a model DLM8–350E is rated
at 0–8 VDC and 0–350 amps. The DLM–E Series employs high frequency switching regulator
technology to achieve high power density and small package size.
1.2Operating Modes
The DLM–E Series supply has two basic operating modes: Constant Voltage and Constant
Current. In constant voltage mode, the output voltage is regulated at the selected value while
the output current varies with the load requirements. In constant current mode, the output
current is regulated at the selected value while output the voltage varies with the load
requirements.
An automatic crossover system enables the unit to switch operating modes in response to
varying load requirements. If, for example, the unit is operating in voltage mode and the load
current attempts to increase above the setting of the current control, the unit will switch
automatically from voltage mode to current mode. If the load current is subsequently reduced
below the setting of the current control the unit will return to voltage mode automatically.
1.3Power Supply Features
•3 kW and 4 kW models with voltage ranges from 0–5 VDC to 0–600 VDC and
current ranges from 0–5A to 0–450A.
•3 kW models operate with either single or three–phase AC input power without
jumpers.
•High input AC power factor, 0.95 typical, with three–phase 208, 400, or 480 VAC
inputs.
M362000-01 Rev E 1-1
Features and Specifications DLM-E 3kW & 4kW Series Power Supplies
• High input AC power factor, 0.98 typical, with single–phase input.
• Front panel controls for Enable/Standby and Local/Remote modes of operation.
• Simultaneous digital display of both DC voltage and current.
• Front panel preview switch allows voltage, current, and OVP to be preset from local
or remote control.
• Local lockout feature with front panel indicator is selectable by rear panel switch.
• No internal jumpers or switches to change programming and monitor ranges.
• Current sharing parallel port and simple cable interface allows several units to be
connected in parallel to provide increased power and current.
•Voltage and current controls with ten turn potentiometers permit high resolution
setting of the output voltage and current from zero to the rated output.
• Automatic mode crossover into current or voltage mode, with mode indication.
• High frequency switching technology allows high power density, providing
increased power output in a small package.
• Remote sensing to compensate for losses in power leads.
• Fast response time for programming or load changes.
• Adjustable Over–Voltage Protection (OVP) with preview
• External DC shutdown (positive or negative logic selectable).
• Remote voltage, current, and OVP programming with selectable programming
range.
•External indicator signals for remote monitoring of OVP status, local/remote
programming status, thermal shutdown, and output voltage and current.
•Installation Category III, Pollution degree 2.
For Indoor Use Only.
•CE Approvals to EN61010-1 1993
CE Mark tested to: EN61326
EN61010-1:1993
(FCC) 47 CFR Part 15, Subpart B, 107 (e), Class A, 109 (g) Class A
•Optional IEEE-488 interface for complete remote programming and readback
capability with M9E option.
•M85 slave option allows programming of up to 31 power supplies from one GPIB
address.
1-2 M362000-01 Rev E
DLM-E 3kW & 4kW Series Power Supplies Features and Specifications
Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)
Load Regulation:11
Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)
Meter Accuracy:
Voltage (0.5% Vmax+1count)
Current (0.75% Imax+1count)
Preview Accuracy
Voltage (0.5% Vmax+1 count)
Current (1.0% Imax+1 count)
OVP Adjustment Range
(6% to 110% Vmax)
Output Noise and Ripple (V)
RMS
p–p (20 Hz–20 MHz)
13, 14
Stability:
Voltage (0.05% of Vmax)
Current (0.05% of Imax)
0–5V
0–450A
2250W
5 mV
450 mA
5 mV
450 mA
0.04V
5A
0.04V
6A
0.3–
5.5V
12 mV
100
12
mV
3 mV
225 mA
0–8V
0–450A
3600W
6 mV
450 mA
6 mV
450 mA
0.05V
5A
0.05V
6A
0.4–
8.8V
12 mV
100
mV12
4 mV
225 mA
0–16V
0–250A
4000W
10 mV
250 mA
10 mV
250 mA
0.09V
3A
0.09V
4A
0.8–
17.6V
10 mV
100
mV12
8 mV
125 mA
0-22V
0-180A
4000W
13 mV
180mA
13 mV
180mA
0.2V
3A
0.2V
3A
1.1-
24.2V
10 mV
100
mV12
11 mV
90 mA
0–32V
0–125A
4000W
18 mV
125 mA
18 mV
125 mA
0.3V
1A
0.3V
1.4A
1.6–35V
10 mV
100
mV12
16 mV
63 mA
0–40V
0–100A
4000W
22 mV
100 mA
22 mV
100 mA
0.3V
0.9A
0.3V
1.1A
0–60V
0–66A
3960W
32 mV
66 mA
32mV
66 mA
0.4V
0.6A
0.4V
0.8A
0–80V
0–50A
4000W
42 mV
50 mA
42 mV
50 mA
0.5V
0.5A
0.5V
0.6A
2–44V 3–66V 4–88V
10 mV
100
mV12
20 mV
50 mA
15 mV
100 mV
30 mV
33 mA
15 mV
120 mV
40 mV
25 mA
0–150V
0–26A
3900W
77 mV
26 mA
77 mV
26 mA
0.9V
0.3A
0.9V
0.4A
7.5–
165V
30 mV
100 mV
75 mV
13 mA
0–300V
0–13A
3900W
152 mV
13 mA
152 mV
13 mA
1.6V
0.11A
3V
0.14A
15–
330V
60 mV
150 mV
150 mV
6.5 mA
0–600V
0–6.6A
3960W
302 mV
7 mA
302 mV
7 mA
3.1V
0.06A
4V
0.08A
30–
660V
100 mV
300 mV
300 mV
3.3 mA
Temperature Coefficient:15
Voltage (0.02% of Vmax)
Current (0.03% of Imax)
Maximum Remote Sense
Line Drop Compensation per line
9. Specifications are warranted over a temperature range of 0–50°C with default local sensing.
From 50–70°C, derate output 2% per °C.
From 40–70°C, derate output 2% per °C below 190 VAC with single or three–phase inputs.
10. For input voltage variation over the AC input voltage range, with constant rated load.
11. For 0–100% load variation, with constant nominal line voltage.
12. Typical P–P noise and ripple is 50 mV.
13. Maximum drift over 8 hours with constant line, load, and temperature, after 15 minute warm–up (30 minute warm–up
for 5V, 8V, and 16V models).
14. Current accuracy for 5V, 8V, and 16V models is 1% typical.
15.
Change in output per °C change in ambient temperature, with constant line and load.
16. Line drop subtracts from the maximum available output voltage at full rated power.
1 mV
135 mA
2V 2V 2V 2V 5V 5V 5V 5V 5V 5V 5V
16
1.6 mV
135 mA
3.2 mV
75 mA
4.4 mV
54 mA
6 mV
38 mA
8 mV
30 mA
12 mV
19.8 mA
16 mV
15 mA
30 mV
7.8 mA
60 mV
3.9 mA
120 mV
2.0 mA
1-4 M362000-01 Rev E
DLM-E 3kW & 4kW Series Power Supplies Features and Specifications
1.4.3Additional Specifications
AC Input:
Output
Power
3 kW19
3 kW19
4 kW
4 kW
4 kW
17. Maximum input current measured at low AC line and maximum output power.
18. Power factor measured at nominal line, maximum output power.
19.
The 3 kW DLM–E is designed to operate without derating to the output power level with either
a single–phase or three–phase AC input voltage without any internal jumper changes.
Nominal Input
Voltage
230 VAC
Single–Phase
208 VAC
Three–Phase
208 VAC
Three–Phase
380/400/415 VAC
Three–Phase
480 VAC
Three–Phase
Input
Option
Std 180–264 VAC L–L21A RMS 0.98
Std 180–264 VAC L–L12A RMS 0.95
Std 180–264 VAC L–L15A RMS 0.95
M1 345–455 VAC L–L8.5A RMS 0.95
M2 432–528 VAC L–L6.5A RMS 0.95
Input Range
(47–63 Hz)
Input Current
Maximum
17
Input Power
Efficiency: 5 and 8 VDC models – 82% typical, 16–600 VDC models – 87% typical
Altitude: 2000M (6562 Ft.)
Operating Temperature Range: 0 to 50°C
Storage Temperature Range: –40 to +85°C
Factor18
Humidity Range: 0 to 80% Non–condensing
Time Delay from power on until output is stable: 10 seconds maximum
Voltage Mode Transient Response Time: 1 ms recovery to 1% band for 30% step load
change from 70% to 100% or 100% to 70%
Remote Start/Stop and Interlock: TTL compatible input, Contact Closure, 5–24 VDC.
Switching Frequency: Nominal 32 kHz (64 kHz output ripple)
Float Voltage: Negative output terminal may be biased to 150 VDC relative to chassis.
For models 16V, 22V output terminal may be biased to 600 VDC relative to
chassis.
Remote Analog Programming (Full Scale Input): Scales are selectable through rear panel.
Parameter Resistance Voltage
Voltage
Current
OVP
5 kΩ
5 kΩ
5 kΩ
5V, 10V
5V, 10V
5V, 10V
Analog ProgrammingAccuracy: 1% of rated output for voltage programming, 5% of rated
output for resistance programming, 2% of rated output voltage for OVP.
M362000-01 Rev E
1-5