SELECTRONIC® SENSOR OPERATED
CONCEALED TOILET FLUSH VALVE
WITH WALL BOX FOR WALL-HUNG, BACK SPUD BOWLS
BASE MODEL: (Does Not include Power Supply)
❑ 60 6B.312 Base Model, 1.1 gpf
FRONT ACCESS
Fully mechanical manual override
Vandal-resistant, stainless steel wall box
❑ 606B.322 Base Model, 1.28 gpf
SAME AS ABOVE
❑ 606B.362 Base Model, 1.6 gpf
SAME AS ABOVE
POWER KITS: (Must be Purchased Separately)
❑ PK00.CRP CR-P2 lithium battery and holder
❑ PK00.WRK PWRX 10-Year battery pack and holder
GENERAL DESCRIPTION:
Concealed, Sensor Operated Selectronic® Toilet Flush
Valve with Wall Box (Front Access) for wall-hung bowls
with 1-1/2" back spud.
PRODUCT FEATURES:
• Self-Cleaning Piston with integral wiper spring
signicantly reduces clogging and maintenance
• Selectronic® Proximity System with universal
sensor provides hygienic, "hands free" operation
• State-of-the-Art Electronics prevent ghost ushing
• Dezincication Resistant semi-red brass alloy
• Fully Mechanical Manual Override Button
can ush the valve without power
• Fail-Safe: Valve automatically closes upon loss of power
or water pressure and does not need to be reset
• Adjustable Sanitary Flush cleans the xture &
maintains the trap seal.
• Chemical resistant EPDM Seals for extended life
• Adjustable tailpiece for rough-in exibility
• Can be installed left or right handed
• All exposed parts are chrome-plated
❑ PK00.PAC Plug-In AC transformer and capacitor
module
❑ PK00.HAC Hard-Wired AC transformer, 10'
extension cable and capacitor module
❑ PK00.MAC Multi-AC adapter and 10" extension
cable
OPERATING PRESSURE:
25 psi (owing) - 80 psi (static)
FLOW REQUIREMENT:
25 gpm (94.6 L/min.)
403 mm
(15-7/8")
279 mm
INCLUDES:
• 1" I.P.S. angle stop with back-ow protection and
hand wheel
• 1" Sweat solder adapter
• 1-1/2" Vacuum breaker with spud coupling and ange
(11")
SUGGESTED SPECIFICATION
Electronic, sensor activated toilet ush valve for wall-hung bowls (with 1-1/2" back spud) shall feature self-cleaning piston valve
with integral wiper spring in rell orice to prevent clogging. Shall feature a fully mechanical manual override that can ush the
valve without power. Shall also feature a semi-red brass valve body and vandal-resistant stainless steel wall box that includes
the sensor and manual override button. Includes angle stop with back-ow protection and hand wheel. Sweat solder adapter
and vacuum breaker also included. Must be installed and maintained from the front. Flush Valve shall be American Standard
Model # 606B_3_2.007.
© 2016 AS America Inc.
(9/16)
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
SELECTRONIC® SENSOR OPERATED
CONCEALED TOILET FLUSH VALVE
WITH WALL BOX FOR WALL-HUNG, BACK SPUD BOWLS
Roughing-in Dimensions
BACK SPUD BOWLS
404 mm
(15-7/8")
389 x 265 mm
(15-5/16" X 10-3/8")
ROUGH OPENING FOR BOX
SENSOR
OVERRIDE
280 mm
(11 ")
*
-C-L-
152 mm
(6") MIN.
BUTTON
-C-L-
108-134 mm
(4-1/4" TO 5-1/4")
SUPPLY
(1) NPT
TOP OF
FIXTURE
51mm
(2)
400 mm MAX.
(15-3/4") MAX.
25 mm (1") MAX.
WALL THICKNESS
FINISHED WALL
TOP SPUD
TOILET
70 mm
(2-3/4") DIA.
128 mm MAX.
(5") MAX.
CAUTION: Use only American Standard
supplied cable sets. Using non-AS
supplied cables, or cutting, splicing or
modifying any components will void the
warranty.
15˚
DETECTION ZONE
400-800 mm
(Factory Setting: 400 mm)
FOR LOCATION OF INLET SUPPLY ON BACK INLET
FIXTURES AND CORRECT HEIGHT FROM FINISHED FLOOR,
REFER TO FIXTURE INSTRUCTION SHEET.
-C-L-
EXPOSED BACK
SPUD TOILET
176 mm MAX.
(6-15/16") MAX.
450 mm MAX.
(17-3/4") MAX.
152 mm MIN.
TOP OF
FIXTURE
*-C-L-
(6") MIN.
CONCEALED BACK
SPUD TOILET
240 mm MAX.
(9-1/2") MAX.
TOP OF
FIXTURE
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
above fixture. Consult Codes for details.
© 2016 AS America Inc.
" (152 mm) min.
FINISHED
FLOOR
51 mm
(2")
51 mm
(2")
(9/16)