American Standard 606B.301, 606B.305, 606B.310 User Manual

SELECTRONIC® SENSOR OPERATED,
GENERAL DESCRIPTION:
PRODUCT FEATURES:
Pressure Compensation feature ensures accurate ush volume regardless of inlet water pressure
Self-Cleaning Piston with integral wiper spring signicantly reduces clogging and maintenance
Selectronic Proximity System with universal sensor provides hygienic, "hands free" operation
State-of-the-Art Electronics prevent ghost ushing
Dezincication Resistant brass alloy
Fully Mechanical Manual Override Button can ush
the valve without power
Fail-Safe: Valve automatically closes upon loss of power or water pressure and does not need to be reset
Adjustable Sanitary Flush cleans the xture & maintains the trap seal.
Stadium Feature: Valve automatically switches to water savings mode during periods of heavy usage
• Chemical Resistant EPDM Seals for extended life
• Adjustable tailpiece for rough-in exibility
• Can be installed left or right handed
• All exposed parts are chrome-plated
CONCEALED URINAL FLUSH VALVE
BACK SPUD
BASE MODEL: (Does Not include Power Supply)
606B.301 Base Model, 0.125 gpf/0.5 Lpf
REAR ACCESS
Fully mechanical manual override
Vandal-resistant, chrome-plated metal wall plate
606B.305 Base Model, 0.5 gpf/1.9 Lpf
SAME AS ABOVE
606B.310 Base Model, 1.0 gpf/3.8 Lpf
SAME AS ABOVE
POWER KITS: (Must be Purchased Separately)
PK00.CRP CR-P2 lithium battery and holder
PK00.WRK PWRX
10-Year battery pack and holder
PK00.PAC Plug-In AC transformer and Single AC
adapter
PK00.HAC Hard-Wired AC transformer, 10'
extension cable and Single AC adapter
PK00.MAC Multi-AC adapter and 10" extension
cable
OPERATING PRESSURE:
20 psi (owing) - 80 psi (static)
FLOW REQUIREMENT:
10 gpm/37.9 L/min
160 mm
(6-1/4")
160 mm
(6-1/4")
INCLUDES:
• 3/4" I.P.S. angle stop with back-ow protection and hand wheel
• 3/4" Sweat solder adapter
• 3/4" Vacuum breaker with spud coupling and ange
ADA COMPLIANT
SUGGESTED SPECIFICATION
Electronic, sensor activated ush valve for 3/4" back spud urinal shall feature self-cleaning piston valve with integral wiper spring in rell orice to prevent clogging. Shall feature a fully mechanical manual override that can ush the valve without power. Shall also feature a dezincication­resistant brass valve body and chrome-plated metal wall plate that includes the sensor and manual override button. Includes angle stop with back-ow protection and hand wheel. Sweat solder adapter and vacuum breaker also included. Must be installed and maintained from the rear. Flush Valve shall be American Standard Model # 606B.3__.007.
© 2018 AS America Inc.
6/18
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
Roughing-in Dimensions
SELECTRONIC® SENSOR OPERATED,
CONCEALED URINAL FLUSH VALVE
BACK SPUD
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
*Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6
above fixture. Consult Codes for details.
160 mm
(6-1/4")
160 mm (6-1/4")
-C-L-
108-134 mm (4-1/4 "TO 5-1/4")
*
-C-L-
152 mm
(6") MIN.
OVERRIDE BUTTON
SENSOR
SUPPLY (3/4) NPT
TOP OF FIXTURE
" (152 mm) min.
32 mm
(1-1/4") DIA.
127 X 127 mm (5X5 CUTOUT FOR BOX)
WALL THICKNESS
25 mm (1") MAX.
TOP SPUD FIXTURES
-C-L- -C-L-
203 mm MAX. (8") MAX.
63 mm (2-1/2") DIA.
TOP OF FIXTURE
DETECTION ZONE 400-800 mm (Factory Setting: 400 mm)
15˚
360 mm MAX.
(14-3/16") MAX.
203 mm MAX.
(8") MAX.
120 mm MAX.
(4-3/4") MAX.
FOR LOCATION OF INLET SUPPLY ON BACK INLET
FIXTURES AND CORRECT HEIGHT FROM FINISHED FLOOR,
REFER TO FIXTURE INSTRUCTION SHEET.
BACK SPUD
FIXTURES
TOP OF FIXTURE
(1-1/4") DIA.
360 mm MAX.
(14-3/16") MAX.
32 mm
*
-C-L-
152 mm
(6") MIN.
Meets the American Disabilities Act Guidelines and ANSI A117.1 Requirements for accessible
and usable building facilities - check local codes
© 2018 AS America Inc.
6/18
Loading...