American Standard 606B2XX Installation Manual

SELECTRONIC
®
CONCEALED TOILET FLUSH VALVE
1.1. 1.28 & 1.6 GPF
MODEL NUMBERS
606B2XX
Concealed Back SpudExposed Back Spud Top Spud
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components
Certied to comply with ASME A112.19.2
© 2017 AS America, Inc.
will void the warranty.
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance, please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369) (In Toronto Area only: 1-905-306-1093)
© 2017 AS America Inc.
1
M965640 Rev. 1.4 (11/17)
Thank you for selecting American-Standard...the benchmark of ne quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions
2. Flush Valve Body Assembly
3. Cover Plate with Sensor
4. Electrical Box
5. Sweat Adapter
6. Stop Valve
7. Manual Override Hoses
Some Residual Water May Remain In The Valve During Shipping.
8a. Vacuum Breaker Flush Connection
(Exposed Back Spud)
8b. Vacuum Breaker Flush Connection
(Concealed Back Spud)
8c. Vacuum Breaker Flush Connection
(Top Soud)
POWER KITS — SOLD SEPARATELY
All American Standard Products Are Water Tested At Our Factory.
4
TOP
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
SELECTRONIC™CONCEALED TOILET FLUSH VALVE
3
1.28 & 1.6 GPF
MODEL NUMBERS
606B.2XX
PWRX
Power Kit
Plug-In AC
Power Kit
PK00. PACPK00.WRK
Hard-Wired AC
Power Kit
PK00.HAC
7
1
2
VACUUM BREAKER FLUSH CONNECTIONS
606X.2X1
606X.2X2
Certied to comply with ASME A112.19.2
© 2016 AS America, Inc.
Concealed Back SpudExposed Back Spud Top Spud
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
(In Toronto Area only: 1-905-306-1093)
8c8b8a
Multi-AC
Power Kit
CR-P2 Battery
Power Kit
6
5
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
606X.2X3
PK00.MAC
2
M965640 Rev. 1.4 (11/17)
Fig. 1
Roughing-in Dimensions
160mm
(6-1/4)
160mm
(6-1/4)
SUPPLY (1) NPT
-C-L- -C-L-
108mm-134mm
*-C-L-
152mm MIN.
(6) MIN.
(4-1/4 TO 5-1/4)
OVERRIDE BUTTON
SENSOR
TOP OF FIXTURE
127mm X 127mm (5X5 CUTOUT FOR BOX)
51mm
(2)
400mm MAX. (15-3/4) MAX.
25mm (1) MAX.
WALL THICKNESS
FINISHED WALL
TOP SPUD
TOILET
70mm (2-3/4) DIA.
128mm MAX.
(5) MAX.
DETECTION ZONE 400mm-800mm (Factory Setting: 400mm)
15˚
360mm MAX.
(14-3/16) MAX.
EXPOSED BACK
SPUD TOILET
GENERAL DESCRIPTION:
SELECTRONIC® PROXIMITY TOILET FLUSH VALVE
Concealed Flushometer for 1-1/2" Top Spud Fixtures
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
FOR LOCATION OF INLET SUPPLY ON BACK INLET
FIXTURES AND CORRECT HEIGHT FROM FINISHED FLOOR,
REFER TO FIXTURE INSTRUCTION SHEET.
CONCEALED BACK
SPUD TOILET
*-C-L-
TOP OF FIXTURE
152mm MIN.
(6) MIN.
240mm MAX.
(9-1/2) MAX.
450mm MAX. (17-3/4) MAX.
TOP OF
FIXTURE
*Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6
above fixture. Consult Codes for details.
" (152mm) min.
RECOMMENDED TOOLS; Fig. 2.
1. Teon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line
IMPORTANT:
All plumbing and electrical wiring should be installed in accordance with applicable codes and regulations.
• The use of water hammer arrestors is strongly recommended for commercial applications. All piping
behind the walls should be properly secured and fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each xture.
51mm
(2)
FINISHED FLOOR
51mm
(2)
FINISHED FLOOR
Fig. 2
1
2
10'
4
3
6
5
7 9 10
• Flush all water lines prior to operation (See Step 3). Dirt and debris can cause ush valve to run continuously.
With the exception of Stop Valve Inlet, DO NOT
use pipe sealant or plumbing grease on any valve component or coupling!
• Protect the chrome or special nish on the Flushometer.
DO NOT USE toothed tools on nished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
8
FINISHED FLOOR
3
M965640 Rev. 1.4 (11/17)
FLUSH VALVE INSTALLATION
INSTALL ELECTRICAL BOX; Fig. 3
1
1. Cut a 127x127mm (5"x 5") opening in nished wall for ELECTRICAL BOX (1) at the dimension shown.
Fig.3 (TOP SPUD FIXTURE ILLUSTRATED)
2
TOP
3
127mm
(5)
127mm
(5)
2. Rotate the 4 MOUNTING TABS (2) at against the
electrical box. Holding the MOUNTING TABS (2) in position, install the ELECTRICAL BOX (1) into the opening. Make sure the MOUNTING TABS (2) are behind the wall.
3. Tighten the 4 MOUNTING SCREWS (3) until the
ELECTRICAL BOX (1) is almost secure in the wall. Before tighting fully, rest a level at the top edge of the ELECTRICAL BOX (1) and make sure the box is level.
4. Cut a 2" diameter hole for outlet pipe at dimension
shown.*
2
INSTALL SWEAT ADAPTER; Fig. 4
CAUTION
Turn water supplies off before beginning
Note: Stop Valve inlet is 1" NPT. For optional sweat connection, install Sweat Adapter (1) (Supplied) for 1"
copper pipe supply line.
1. Clean the end of the supply pipe. Push the threaded SWEAT ADAPTER (1) until it is seated against the internal stop. Sweat the ADAPTER (1) to the pipe.
360mm MAX.
(14-3/16) MAX.
128mm MAX.
(5) MAX.
Fig. 4
115mm-134mm
(4-1/2 TO 5-1/4)
STOP
VALVE
OUTLET
TOP
1
*FOR HOLE LOCATION OF OUTLET PIPE ON BACK INLET FIXTURES, REFER TO FIXTURE BEING INSTALLED FOR CORRECT HEIGHT FROM FINISHED FLOOR
TOP
2
1
FILE
EDGES
STOP VALVE (1" NPT)
CLEAN & SOLDER TO ADAPTER (1)
2
2. Install the STOP VALVE (2) to the water supply line
with the outlet positioned as required (Behind the Wall).
3. Support piping as required.
3
FLUSH OUT SUPPLY LINES; Fig. 5
1. Open STOP VALVE (1).
2. Tur n on water supply line to ush line of any debris or
sediment.
3. Close STOP VALVE (1) and turn off water supply line.
Fig. 5
COUNTER-CLOCKWISE
OPENS STOP VALVE
CLOCKWISE CLOSES STOP VALVE
1
4
M965640 Rev. 1.4 (11/17)
Loading...