American DJ PAR Z100 5K operation manual

0 (0)
American DJ PAR Z100 5K operation manual

PAR Z100 5K

User Instructions

9/17

©2017 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective companies.

ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsufficient and negligent assembly, installation, rigging, and operation of this product.

DOCUMENT VERSION

Please check www.adj.com for the latest revision/update of this guide.

Date

Document

Software

DMX

 

Channel

Notes

Version

Version >

 

Mode

 

 

 

 

 

 

 

 

 

 

09/27/17

1

1.0

1/2/3

Initial Release

 

 

 

 

 

Europe Energy Saving Notice

Energy Saving Matters (EuP 2009/125/EC)

Saving electric energy is a key to help protecting the enviroment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!

Par Z100 5K

General Information

Unpacking: Thank you for purchasing the Par Z100 5K by ADJ Products, LLC. Every Par Z100 5K has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all equipment necessary to operate the unit has arrived intact. In the event damage has been found or parts are missing, please contact our toll free customer support number for further instructions. Please do not return this unit to your dealer without contacting customer support first.

Introduction: The Par Z100 5K is a DMX intelligent, zooming, LED par fixture. The Par Z100 5K also operates as a stand alone fixture. This fixture is suitable for theaters, studios, retail stores, and other similar locations. For best results use fog or special effects smoke to enhance the beams projections.

Customer Support: ADJ Products, LLC provides a toll free customer support line, to provide help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacific Standard Time.

Voice:

(800)

322-6337

Fax:

(323)

582-2941

E-mail:

support@americandj.com

Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Warning! This may cause severe eye damage. Avoid looking directly into the light source at all times!

Par Z100 5K

General Instructions

To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.

Par Z100 5K

Features

DMX-512 Protocol Compatible (3 DMX Channel Modes: 1 Channels, 2 Channels, & 3 Channels)

5-Pin XLR In/Out Connections

powerCON In/Out Connections

5 Dimmer Curves (Standard, Stage, TV, Architectural, & Theatre)

Digital Display for Address and Function Setting

Gamma Correction Adjustment

Dimming Frequency Adjustment

Multiple Unit Power Linking (See page 18)

Par Z100 5K

Warranty Registration

The Par Z100 5K carries a 2 year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase and warranty. You may also register your product online at www. adjproducts. com. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. If the unit is under warranty you must provide a copy of your proof of purchase invoice. Please contact ADJ Products, LLC customer support for a R.A. number.

Par Z100 5K

Handling Precautions

Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.

During operation the housing may become extremely hot. Avoid touching the unit with bare hands while in use.

ADJ Products, LLC will not accept any liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to this unit.

ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 2

ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 3

Figure 1

Par Z100 5K

Safety Precautions

For Your Own Personal Safety, Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit!

To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture

Do not spill water or other liquids into or on to your unit.

Be sure that the local power outlet match that of the required voltage for your unit.

Do not attempt to operate this unit if the power cord has been frayed or broken.

Do not attempt to remove or break off the ground prong from

the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.

Disconnect from main power before making any type of connection.

Do not remove the cover under any conditions. There are no user serviceable parts inside.

Never operate this unit when it’s cover is removed.

Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.

Do not attempt to operate this unit, if it becomes damaged.

This unit is intended for indoor use only, use of this product outdoors voids all warranties.

Always mount this unit in safe and stable matter.

Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.

Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 19 for cleaning details.

Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.

The fixture should be serviced by qualified service personnel when: A. Objects have fallen, or liquid has been spilled into the appliance. B. The appliance has been exposed to rain or water.

C. The appliance does not appear to operate normally or exhibits a marked change in performance.

Par Z100 5K

DMX Set Up

Power Supply: The ADJ Par Z100 5K contains a automatic voltage switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.

DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).

DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. Therefore, the first fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): The Par Z100 5K can be controlled via DMX-512 proto-

col. The Par Z100 5K three DMX channel modes; 1 channel mode, 2 channel mode, & 3 channel mode. The DMX

address is set electronically using the controls on the rear panel of the unit. Your unit and your DMX controller require a approved DMX-512 110 Ohm Data cable for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all professional sound and

ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 4

ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 5

Par Z100 5K

DMX Set Up

lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.

Notice: Besuretofollowfigurestwoandthreewhenmakingyourown cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.

 

 

 

COMMON

 

 

 

DMX512 O T

1

DMX +

1

DMX512 IN

 

3

DMX -

3

 

3-PIN XLR

2

2

3-PIN XLR

 

 

 

 

 

Figure 2

XLR Male Socket

XLR Female Socket

XLR Pin Configuration

1 Ground

2 Cold

2 Cold

1 Ground

Pin 1 = Ground

 

 

 

 

 

Pin 2 = Data Compliment (negative)

 

3 Hot

 

3 Hot

Pin 3 = Data True (positive)

Figure 3

Special Note: Line Termination. When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.

 

Termination reduces signal errors and

 

1

avoids signal transmission problems

 

3

and interference. It is always advisable

 

2

to connect a DMX terminal, (Resistance

 

 

120 Ohm 1/4 W) between PIN 2 (DMX-)

Figure 4

 

and PIN 3 (DMX +) of the last fixture.

Par Z100 5K

DMX Set Up

5-Pin XLR DMX Connectors. This unit use 5-pin DMX-512 data cablesforDATAtransmission.5-pinDMX fixturesmaybeimplemented in a 3-pin DMX line. When inserting standard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.

3-Pin XLR to 5-Pin XLR Conversion

Conductor

3-Pin XLR Female (Out)

5-Pin XLR Male (In)

Ground/Shield

Pin 1

Pin 1

Data Compliment (- signal)

Pin 2

Pin 2

Data True (+ signal)

Pin 3

Pin 3

Not Used

 

Pin 4 - Do Not Use

Not Used

 

Pin 5 - Do Not Use

ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 6