ED2-60
W164 N9221 Water Stre et • P.O. Box 450 • Menomonee Falls, Wis consin 53 052-0 450 USA
PHONE: 262.251.3800 • 80 0.558.8744
US A/CAN ADA FAX: 262.251.7067 • 800.329.8744 U .S. A. ONLY
www.alto- shaam.com
H e a t e d D i s p l a y C a s e s
F u l l S e r v i c e o r S e l f S e r v i c e
Models:
ED2-60
P RI NT ED I N U .S .A.
• INSTALLATION
• OPERATION
• MAINTENANCE
MN- 28 84 7 • 1 2/ 09
Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety Procedures and Precautions . . . . . . . . . . . . . 2
Installation
Installation Requirements . . . . . . . . . . . . . . . . . . 3
Clearance Requirements. . . . . . . . . . . . . . . . . . . 3
Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . 4
Options & Accessories. . . . . . . . . . . . . . . . . . . . . 4
Electrical Connection. . . . . . . . . . . . . . . . . . . . . . 5
Operating Instructions
User Safety Information. . . . . . . . . . . . . . . . . . . . 6
Start-up Operation. . . . . . . . . . . . . . . . . . . . . . . . 6
Operating Procedures . . . . . . . . . . . . . . . . . . . . . 7
Pan Configurations . . . . . . . . . . . . . . . . . . . . . . . 8
General Holding Guidelines . . . . . . . . . . . . . . . . . 9
Care and Cleaning
Cleaning and Preventive Maintenance. . . . . . . . 10
Protecting Stainless Steel Surfaces. . . . . . . . . . 10
Cleaning Agents . . . . . . . . . . . . . . . . . . . . . . . . 10
Cleaning Materials. . . . . . . . . . . . . . . . . . . . . . . 10
Equipment Care. . . . . . . . . . . . . . . . . . . . . . . . . 11
Clean the Probes. . . . . . . . . . . . . . . . . . . . . . . . 11
Clean Daily . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sanitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Service
Cable Replacement Kits . . . . . . . . . . . . . . . . . . 13
Full Assembly, Front View. . . . . . . . . . . . . . . 14-15
Inner Top Assembly . . . . . . . . . . . . . . . . . . . . . . 16
Control Assembly . . . . . . . . . . . . . . . . . . . . . . . 17
Wire Diagrams
ED2-60, 230V . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Warranty
Transportation Damage and Claims. . . Back Cover
Limited Warranty . . . . . . . . . . . . . . . . . Back Cover
i
D E L I V E R Y
This Alto-Shaam appliance has been
thoroughly tested and inspected to ensure only the
highest quality unit is provided. Upon receipt,
check for any possible shipping damage and report
it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached
items and accessories, may have been delivered in
one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.
Save all the information and instructions
packed with the appliance. Complete and return
the warranty card to the factory as soon as
possible to ensure prompt service in the event of a
warranty parts and labor claim.
This manual must be read and understood by
all people using or installing the equipment
model. Contact the Alto-Shaam service
department if you have any questions concerning
installation, operation, or maintenance.
N O TE: All claims for warranty must include the
full model number and serial number of
the unit.
U N P A C K I N G
1. Carefully remove the
appliance from the
carton or crate.
N O TE: Do not discard the
carton and other
packaging material
until you have
inspected the unit
for hidden damage
and tested it for
proper operation.
2. Read all instructions in this manual carefully
before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the
appliance and is to be provided to the owner or
manager of the business or to the person
responsible for training operators. Additional
manuals are available from the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging
materials, and accessories from the appliance
before connecting electrical power. Store any
accessories in a convenient place for future use.
ED2 - 60 Op e rat i on & Car e M anu a l • 1
1. This appliance is intended to hold or process
foods for the purpose of human consumption.
No other use for this appliance is authorized
or recommended.
2. This appliance is intended for use in commercial
establishments where all operators are familiar
with the purpose, limitations, and associated
hazards of this appliance. Operating
instructions and warnings must be read and
understood by all operators and users.
3. Any troubleshooting guides, component views,
and parts lists included in this manual are for
general reference only and are intended for use
by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all
supplied instructions, diagrams, schematics,
parts lists, notices, and labels must remain with
the appliance if the item is sold or moved to
another location.
N O T E : Used to notify personnel of
installation, operation, or
maintenance information that is
important but not hazard related.
C A U T I O N
Used to indicate the presence of a hazard that can
or will cause minor personal injury, property
damage, or a potential unsafe practice if the
warning included with this symbol is ignored.
C A U T I O N
Used to indicate the presence of a
hazard that can or will cause minor or
moderate personal injury or property
damage if the warning included with
this symbol is ignored.
D A N G E R
Used to indicate the presence of a
hazard that WILL cause severe
personal injury, death, or substantial
property damage if the warning
included with this symbol is ignored.
W A R N I N G
Used to indicate the presence of a
hazard that CAN cause personal injury,
possible death, or major property
damage if the warning included with
this symbol is ignored.
SAF ETY P ROC EDU RES
AND PR ECA UTI ONS
Knowledge of proper procedures is essential to the
safe operation of electrically and/or gas energized
equipment. In accordance with generally accepted
product safety labeling guidelines for potential
hazards, the following signal words and symbols
may be used throughout this manual.
N O T E
For equipment delivered for use
in any location regulated by the
following directive:
DO NOT DISPOSE OF ELECTRICAL
OR ELECTRONIC EQUIPMENT WITH
OTHER MUNICIPAL WASTE.
ED2 - 60 Op e rat i on & Car e M anu a l • 2
S I T E IN S TA L L A T I O N
C A U T I O N
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN IN
OPERATION. TO AVOID BURNS,
A
LWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
D A N G E R
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
S
ERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
I N S TA L L AT I O N
In order to maintain
established National
Sanitation Foundation
standards, all
stationary floor models
must be sealed to the
floor with a R.T.V. or
silastic meeting N.S.F.
requirements or
have 6" (152mm)
unobstructed clearance
beneath the unit.
1. The appliance must
be installed on a
stable and level surface.
2. DO N OT install this appliance in any area where it
may be affected by any adverse conditions such as
steam, grease, dripping water, high temperatures, or
any other severely adverse conditions.
3. DO N OT install a heated display case near a cold air
source such as a freezer, air conditioning vents, or
in any area where outside air fluctuation can
affect performance.
4. This appliance must be kept free and clear of
any obstructions blocking access for maintenance
or service.
MINIMUM CLEARANCE REQUIREMENTS
Counter and table units must be mounted on legs
of a sufficient 4" (102mm) height to provide
minimum unobstructed space beneath the unit.
These legs are supplied with the unit. Warranty
will become null and void if these directions are
not followed.
ED2 - 60 Op e rat i on & Car e M anu a l • 3
A number of adjustments are associated with
initial installation and start-up. It is important
that these adjustments be conducted by a
qualified service technician. Installation and
start-up adjustments are the responsibility of the
dealer or user. These adjustments include but are
not limited to thermostat calibration, door
adjustment, leveling, electrical hook-up and
installation of optional casters or legs.
LEVELING
Level the appliance from side-to-side and
front-to-back with the use of a spirit level.
We recommend checking the level periodically to
make certain the floor has not shifted nor the
appliance moved.
NOTE: Failure to properly level this appliance
can cause improper function.
I N S TA L L AT I O N
30-1/
8" (765mm
)
60" (1524mm)
57-7/16" (1457mm)
26-1
/2"
(6
72m
m)
3-2/3"
(92mm)
100.0°
44-5/16" (1125mm)
30" (763mm)
2-1/2"
(63mm)
9-5/8"
(
243mm)
10"
(254mm)
4
-1/2"
(
114mm)
26-1/2" (672mm)
30-1/8" (765mm)
55-13/16" (1416mm)
S I T E IN S TA L L A T I O N
E D 2 - 6 0
PROFILE
ED2- 6 0 — O PTIO N S & ACC E S SORI E S
DESCRIPTION ED2-60
BUTTING KIT
CARVING STATION
GAUGE, INTERIOR AMBIENT TEMPERATURE
GLASS, TEMPERED END PANE, BRONZE KIT
PANEL KIT, COUNTER TOP BRUSHED STAINLESS STEEL
CUSTOM COLOR
PLATFORM SCALE RIGHT HAND
LEFT HAND
THERMOSTAT GUARD COVER PLATE
WORK SHELF WITH GRAVY LANE
5009001
5001874
AVAILABLE
5001143
AVAILABLE
AVAILABLE
5001307
5001308
5007660 (2 REQ'D)
5005638
ED2 - 60 Op e rat i on & Car e M anu a l • 4
E L E C T R I C A L C O N N E C T I O N
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
E L E C T R I C A L
E D2- 6 0
VO LTAGE PH ASE C YCL E/H Z AM PS kW
230V (AGC Y)
1 50 14.6 3.4
BAR E EN D, NO PLU G
N O TE: 230V appliances must be connected
to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
lectrical Code and applicable local codes.
E
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
OF F” position.
I N S TA L L AT I O N
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord with
plug, an all-pole, country-approved disconnection
device that has a contact separation of at least
3mm in all poles must be incorporated in the fixed
wiring for disconnection. When using a cord
without a plug, the green/yellow conductor shall
be connected to the terminal that is marked with
the ground symbol. If a plug is used, the socket
outlet must be easily accessible. If the power cord
needs replacement, use a similar one obtained
from the distributor.
Fo r 230V un its: To prevent an electrical shock
hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked with the
following symbol.
ED2 - 60 Op e rat i on & Car e M anu a l • 5