Alto Shaam ED2-48-2S Service Manual

#870 • 08/06
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 • 800.558.8744 USA/CANADA FAX: 262.251.7067 800.329.8744 U.S.A. ONLY
WEBSITE: www.alto-shaam.com
PRINTED IN U.S .A .
®
Heated Display Cases
Models:
ED2-48/2S
ED2SYS-48/2S
• INSTALLATION
• OPERATION
• MAINTENANCE
ED2SYS-48/2S
#870 ED2-48/2s Series Operation & Care Manual 1
DELIVERY
This Alto-Shaam appliance has been
thoroughly tested and inspected to insure only the
highest quality unit is provided. Upon receipt,
check for any possible shipping damage and
report it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached
items and accessories, may have been delivered in
one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.
Save all the information and instructions
packed with the appliance. Complete and return
the warranty card to the factory as soon as
possible to assure prompt service in the event of a
warranty parts and labor claim.
This manual must be read and understood by
all people using or installing the equipment
model. Contact the Alto-Shaam service
department if you have any questions concerning
installation, operation, or maintenance.
NOTE: All claims for warranty must include the
full model number and serial number of
the unit.
UNPACKING
1. Carefully remove the
appliance from the
carton or crate.
NOTE: Do not discard the
carton and other
packaging material
until you have
inspected the unit
for hidden damage
and tested it for
proper operation.
2. Read all instructions in this manual carefully
before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the
appliance and is to be provided to the owner
or manager of the business or to the person
responsible for training operators. Additional
manuals are available from the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging
materials, and accessories from the appliance
before connecting electrical power. Store any
accessories in a convenient place for future use.
®
®
®
#870 ED2-48/2s Series Operation & Care Manual 2
SAFETY PROCEDURES AND PRECAUTIONS
Knowledge of proper procedures is essential to the
safe operation of electrically and/or gas energized
equipment. In accordance with generally accepted
product safety labeling guidelines for potential
hazards, the following signal words and symbols
may be used throughout this manual.
Used to indicate the presence of a hazard that
will
cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
Used to notify personnel of
installation, operation, or
maintenance information that is
important but not hazard related.
1. This appliance is intended to cook, hold or
process foods for the purpose of human
consumption. No other use for this
appliance is authorized or recommended.
2. This appliance is intended for use in
commercial establishments where all
operators are familiar with the purpose,
limitations, and associated hazards of this
appliance. Operating instructions and
warnings must be read and understood by
all operators and users.
3. Any troubleshooting guides, component
views, and parts lists included in this manual
are for general reference only and are intended
for use by qualified technical personnel.
4. This manual should be considered a
permanent part of this appliance. This
manual and all supplied instructions,
diagrams, schematics, parts lists, notices, and
labels must remain with the appliance if the
item is sold or moved to another location.
NOTE:
#870 ED2-48/2s Series Operation & Care Manual 3
SITE INSTALLATION
In order to maintain NSF standards, counter models must be sealed at bottom by NSF approved sealant, or equipped with casters, or 4" (102mm) legs to provide minimum unobstructed space beneath the unit. Floor units must also be sealed at bottom or have casters or 6" (152mm) legs to provide minimum unobstructed space beneath the unit. Warranty will become null and void if these directions are not followed.
1. The appliance must be installed on a stable and level surface.
2. DO NOT install this appliance in any area where it may be affected by any adverse conditions such as steam, grease, dripping water, high temperatures, or any other severely adverse conditions.
3. DO NOT install near a cold air source such as a freezer, air conditioning vents, or in any area where outside air fluctuation can affect performance.
4. This appliance must be kept free and clear of any obstructions blocking access for maintenance or service.
5. Care must be taken when moving this unit into place because of its glass components.
INSTALLATION
A number of adjustments are associated with initial installation and start-up. It is important that these adjustments be conducted by a qualified service technician. Installation and start-up adjustments are the responsibility of the dealer or user. These adjustments include but are not limited to thermostat calibration, door adjustment, leveling, electrical hook-up and installation of optional casters or legs.
LEVELING
Level the appliance from side-to-side and front-to-back with the use of a spirit level.
We recommend checking the level periodically to make certain the floor has not shifted nor the appliance moved.
NOTE: Failure to properly level this appliance
can cause improper function.
MINIMUM CLEARANCE REQUIREMENTS
Counter and table units must be mounted on legs of a sufficient 4" (102mm) height to provide minimum unobstructed space beneath the unit. These legs are supplied with the unit. Warranty will become null and void if these directions are not followed.
IMPROPER INSTALLATION, ALTERATION, ADJUSTMENT, SERVICE OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH OR CAUSE PROPERTY DAMAGE.
TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE.
®
METAL PARTS OF THIS EQUIPMENT BECOME EXTREMELY HOT WHEN IN OPERATION. TO AVOID BURNS, ALWAYS USE HAND PROTECTION WHEN OPERATING THIS APPLIANCE.
#870 ED2-48/2s Series Operation & Care Manual 4
SITE INSTALLATION
INSTALLATION
48" (1219mm)
26-1/8" (661mm)
23-11/16" (601mm)
18-15/16"
(482mm)
3" (76mm) ADJUSTABLE PEGS IN EACH CORNER
ELECTRICAL
PANEL
ELECTRICAL
OUTLET
8"
(203mm)
8-9/16"
(216mm)
3-13/16"
(97mm)
1" (26mm)
36-3/4" (933mm)
1" (26mm)
10-3/8"
(261mm)
26-1/8" (661mm)
3 ANGLE
SHELF
3 ANGLE
SHELF
23-11/16" (601mm)
27-1/2" (699mm)
25-5/8" (650mm)
36-13/16" (934mm)
37-13/16" (959mm)
10-1/4" (259mm)
47-7/16" (1204mm)
47-7/16" (1204mm)
ED2SYS-48/2S
ED2SYS-48/2S PROFILEED2-48/2S PROFILE
WEIGHT
MODEL NET SHIP CRATED DIMENSIONS (HXWXD)
ED2-48/2S NOT AVAILABLE YET NOT AVAILABLE YET 57" X 43" X 37" (1448mm x 1092mm x 940mm) EST.
ED2SYS-48/2S 340 lb (154 kg) 450 lb (187 kg) EST. 58" X 50" X 56" (1473mm x 1270mm x 1422mm) EST.
#870 ED2-48/2s Series Operation & Care Manual 5
Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes.
Plug the unit into a properly grounded receptacle ONLY, positioning the unit so that the plug is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “OFF” position.
An identification tag is permanently mounted on the cabinet.
Permanent wiring or electrical outlets for this appliance must be installed by a licensed electrician in accordance with local, country, or national codes.
ELECTRICAL CONNECTION
INSTALLATION
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.
ELECTRICAL
ED2-48/2S; ED2SYS-48/2S
VOLTAGE PHASE CYCLE/HZ AMPS kW
at 208V 1 50/60 10.0 2.1 at 240V 1 50/60 11.7 2.8
208-240
COUNTER TOP MODEL ONLY
NEMA 6-20P
20A, 250V PLUG