Allied Telesis AT-MCM02 User Manual

AT-MCM02
Optional Management Module for the AT-MCF Series Media Converters
Installation Guide
PN 613-50232-00 Rev A
Copyright 2001 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA USA 94085
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn International, Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International, Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International, Corp. has been advised of, known, or should have known, the possibility of such damages.

Safety Warnings

Standards: This product meets the following standards.
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emission EN55022 Class A Warning: In a domestic environment this product may cause radio interference in which case the user may
be required to take adequate measures.
Immunity EN50082-1 1997 Electrical Safety TUV-EN60950, UL1950, CSA 950 Laser EN60825 Important: Appendix A contains translated safety statements for installing this equipment. When you see
$
, go to Appendix A for the translated safety statement in your language.
the Wichtig: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dies es Geräts. Wenn S ie
sehen, schlagen Sie in Anhang A den übersetzten Sicherheit shinweis in Ihrer Sprache nach. Vigtigt: Tillæg A indeholder oversatte sikkerhedsadvarsler, der vedrører installation af dette udstyr. Når
De ser symbolet Belangrijk: Appendix A bevat vertaalde veiligheidsopmerkingen voor het installeren van deze apparatuur.
Wanneer u de Important: L'annexe A contient les instructions de sécurité relatives à l'installation de cet équipement.
Lorsque vous voyez le symbole instructions dans votre langue.
Tärkeää: Liite A sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet. Kun näet symbolin, katso käännettyä turvaohjetta liitteestä A.
Importante: l’Appendice A contiene avvisi di sicurezza tradotti per linstallazione di questa apparecchiatura. Il simbolo
Viktig: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser
$
, åpner du til Tillegg A for å finne den oversatte sikkerhetsinformasjonen på ønsket språk.
Importante: O Anexo A contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo
Importante: El Apéndice A contiene mensajes de seguridad traducidos para la instalación de este equipo. Cuando vea el símbolo
Obs! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser
$
, skal De slå op i tillæg A og finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
$
ziet, raadpleeg Appendix A voor vertaalde veiligheidsinstructies in uw taal.
$
, indica di consultare lAppendice A per lavviso di sicurezza nella propria lingua.
$
, leia a advertência de segurança traduzida no seu idioma no Anexo A.
$
, vaya al Apéndice A para ver el mensaje de seguridad traducido a su idioma.
$
, skall du gå till Bilaga A för att läsa det översatta säkerhetsmeddelandet på ditt språk.
U.S. Federal Communications Commission
Industry Canada
$
1
$
2
$
3
$
5
$
, reportez-vous à l'annexe A pour consulter la traduction de ces
$
4
$
$
-
iii

Table of Contents

Safety Warnings ............................................................................................iii
Welcome to Allied Telesyn .........................................................................vii
Where to Find Web-based Guides ...................................................................vii
Document Conventions ....................................................................................vii
Contacting Allied Telesyn...............................................................................viii
Online Support .........................................................................................viii
Telephone or Fax Support........................................................................viii
E-mail Support ........................................................................................... ix
Returning Products ...........................................................................................ix
FTP Server......................................................................................................... ix
For Sales or Corporate Information ..................................................................x
Tell Us What You Think ....................................................................................x
Chapter 1
Overview .......................................................................................................... 1
Chapter 2
Installing the Management Module ........................................................... 3
Verifying the Package Contents ........................................................................ 3
Reviewing the Safety Guidelines .......................................................................3
Installing the Management Module .................................................................. 5
Management LEDs.............................................................................................7
Chapter 3
Configuring the Management Module ...................................................... 9
Cabling the Management Module ................................................................... 11
Loading the MIB File ....................................................................................... 12
Chapter 4
Managing a Multichannel Media Converter .......................................... 13
RS-232 Port....................................................................................................... 13
Telnet Application Protocol..............................................................................14
SNMP Management Program.......................................................................... 14
Management Commands ................................................................................. 15
v
Table of Contents
IP Commands....................................................................................................16
SET IP INTERFACE Command...............................................................16
SHOW IP INTERFACE Command ..........................................................17
SYSTEM Commands........................................................................................17
SET SYSTEM Command ..........................................................................17
SHOW SYSTEM Command......................................................................18
SNMP Commands............................................................................................. 18
SET SNMP COMMUNITY Command ..................................................... 18
SET SNMP MANAGER Command ..........................................................19
SHOW SNMP Command .......................................................................... 20
MC Commands.................................................................................................. 20
SHOW MC CHANNEL Command ........................................................... 20
SET MC MODE Command.......................................................................21
RESET MC CHANNEL Command...........................................................22
LOAD Commands.............................................................................................23
SET LOADER Command..........................................................................24
SHOW LOADER Command......................................................................24
RESTART REBOOT Command................................................................ 25
Chapter 5
Troubleshooting ...........................................................................................27
Warranty Registration .....................................................................................28
Appendix A
Translated Safety Statements ................................................................... 29
Appendix B
Technical Support Fax Order ................................................................... 41
Incident Summary............................................................................................41
vi

Welcome to Allied Telesyn

This installation guide contains instructions on how to install and configure an AT-MCM02 Management Module. This guide also explains how to use the module to manage an AT-MCF Series Media Converter.

Where to Find Web-based Guides

The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, you can go directly to the following web page: www.alliedtelesyn.com/support/prd_libs.htm.

Document Conventions

This guide uses several conventions that you should become familiar with before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may result in bodily injury.
vii

Contacting Allied Telesyn

You can contact Allied Teleysn technical support online or by telephone, fax, or e-mail.

Online Suppo rt

You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/support/supportf.asp or by accessing the Technical Support Knowledge Base from Allied Telesyn’s North American web site. From the Knowledge Base, you can submit a question to our technical support staff and review answers to previously asked questions.

Telephone or Fax Support

For Technical Support via fax, please fill out the “Technical Support Fax Order” on page 41 and send it to the appropriate location listed below.
Americas
United States, Canada, Mexico, Central America, South America Tel: 1 (800) 428-4835, option 4 Fax: 1 (425) 481-3790
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong Tel: (+65) 3815-612 Fax: (+65) 3833-830
Australia
Australia, New Zealand Tel: 1 (800) 000-880 Fax: (+61) 2-9438-4966
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa Tel: (+33) 1-60-92-15-25 Fax: (+33) 1-69-28-37-49
Germany
Germany, Switzerland, Austria, Eastern Europe Tel: (+49) 30-435-900-126 Fax: (+49) 30-435-70-650
Italy
Italy, Spain, Portugal, Greece, Turkey, Israe
l
Tel: (+39) 02-41-30-41 Fax: (+39) 02-41-30-42-00
Japan
Tel: (+81) 3-3443-5640 Fax: (+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland Tel: (+44) 1-235-442500 Fax: (+44) 1-235-442680
viii
AT-MCM02 Management Module Installation Guide

E-mail Suppo rt

United States and Canada
TS1@alliedtelesyn.com
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
Europe
support_europe@alliedtelesyn.com

Returning Products

Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one of the following locations:
North America
Toll-free: 1-800-428-4835, option 4 Fax: 1-503-639-3716
Latin America, the Caribbean, and Virgin Islands
Tel: international code + 425-481-3852 Fax: international code + 425-481-3895
Mexico
Toll-free: 800-424-5012, ext 3852 Fax: international code + 425-481-3895
Australia
Toll-free: 1-800-000-880 Fax: +61-2-9438-4966
Europe, Africa, and the Middle East
Tel: +44-1793-501401 Fax: +44-1793-431099
Puerto Rico
Tel: 1-800-424-5012, ext 3852 or 1-800-424-4284, ext 385
Asia and Southeast Asia
Tel: +65-381-5612 Fax: +65-383-3830
New Zealand
Toll-free: 0800-45-5782
2

FTP Server

If you need management software for an Allied Telesyn device and you know the file name of the software, you can download the software by connecting directly to our FTP server at ftp.alliedtelesyn.com.
At login, enter ‘anonymous’ as the user name and your e-mail address for the password.
ix

For Sales or Corporate Information

You can contact Allied Telesyn for sales or corporate information at one of the locations below:
Allied Teleyn International, Corp.
19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191
Allied Telesyn International, Corp.
960 Stewart Drive, Suite B Sunnyvale, CA 94085 Tel: 1 (800) 424-4284 (US and Canada) Fax: 1 (408) 736-0100

Tell Us What You Think

If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the Send Us Feedback Form at www.alliedtelesyn.com/contact/feedbackf.asp.
x

Chapter 1

Overview

The AT-MCM02 is an optional management module for the AT-MCF06, AT-MCF12, AT-MCF106, and AT-MCF112 Series Multichannel Media Converters. When installed, the AT-MCM02 module allows you to monitor the operating status of the media converter from a management station on your network using either the Telnet application protocol or an SNMP management program. The module also allows you to monitor a media converter by directly connecting a terminal or PC to a management port on the media converter. The AT-MCM02 module allows you to do the following:
Check the link status of the fiber optic and twisted pair ports on the
media converter.
Override the Link Test switch on the media converter and either start
or stop a link test.
Reset the media converter channels.
Download a new version of the media converter’s operating software.
Note
For instructions on how to install the media converter, refer to the installation guide provided with the media converter.
1

Chapter 2

Installing the Management Module

The installation procedures in this chapter should be performed by a network technician who is familiar with Ethernet networks and Ethernet media converters.

Verifying the Package Contents

Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative.
One AT-MCM02 management module
One control cable with a miniDIN connector and a DB9 connector
This installation guide
Warranty card

Reviewing the Safety Guidelines

Please review the following safety guidelines before you begin to install the management module in the media converter.
Laser
Class 1 laser device. $ 6
Laser
Do not stare into the laser beam. $ 7
3
Warning Electric Shock Hazard: To prevent electric shock, do not remove the
cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting the LAN cables. $ 8
Warning Lightning Danger: Do not work on this equipment or cables during
periods of lightening activity. $ 9
Caution Power cord is used as a disconnection device: To de-energize
equipment, disconnect the power cord. $ 10
Caution Pluggable Equipment: The socket outlet should be installed near the
equipment and should be easily accessible. $ 11
Caution Air vents: The air vents must not be blocked on the unit and must have
free access to the room ambient air for cooling. $ 12
Caution Operating Temperature: This product is designed for a maximum
ambient temperature of 40°C. $ 13
Caution All Countries: Install this product in accordance with local and
National Electric Codes. $ 14
4
AT-MCM02 Management Module Installation Guide

Installing the Management Module

To install the management module in your multichannel media converter, perform the following procedure:
Warning
Installing the AT-MCM02 Management Module while the media converter is powered ON could result in damage to the module.
1. Power OFF the media converter by performing one of the following:
For an AC model, unplug the power cord from the power outlet and
then unplug the power cord from the media converter.
For a DC model, follow the steps below:
Warning
When installing this equipment, alway ensure that the frame ground connection is installed first and disconnected last. $ 15
a. Remove the positive and negative feed wires from the terminal block
by loosening the screws to the wire connections with a flathead screwdriver.
b. Remove the frame ground wire from the terminal block by loosening
the screw to the wire connection with a flathead screwdriver.
2. Using a Phillips-head screwdriver, remove the blank faceplate from the
management module expansion slot, located on the back panel of the
media converter. See Figure 1.
AC LINE
Power Supply
100-240 VAC
Main
50-60 Hz
<
1.5A MAX
Back-Up
<<
50 W
Management
>
Port
Figure 1 Removing the Blank Faceplate
3. Remove the management module from the package and store the
packaging in a safe place.
5
Caution
Wear a grounding device and observe all electrostatic discharge precautions when installing the AT-MCM02 Management Module in the media converter. Failure to observe this precaution could result in damage to the unit.
4. Align the AT-MCM02 Management Module with the card guides on the
bottom on the media converter and gently slide the module into place.
Refer to Figure 2.
When the module is about 5 millimeters (0.20 inches) from the media
converter’s backplane, you will feel a slight resistance. At that point, make
sure that the edges of the AT-MCM02 Management Module are parallel to
the corresponding edges of the media converter. Continue to slide the
management module, applying slight pressure, to seat the management
module’s connectors into the media converter’s backplane.
AC LINE
Power Supply
100-240 VAC
Main
50-60 Hz
<
1.5A MAX
Back-Up
<<
50 W
Management
Management
>
>
Port
Port
AT-MCM02
Figure 2 Installing the AT-MCM02 Module
5. Secure the mangement module to the media converter by tightening the
two thumbscrews.
6. Apply power to the media converter by connecting the AC power cord or
DC wires. Refer to installation guide that came with the media converter
for instructions.
7. Check to be sure that the Power LED(s) on the front of the media
converter are green. If the LED(s) are OFF, refer to “Troubleshooting” on
page 27.
8. Check the Ready LED on the front panel of the media converter. The LED
should be green. If the LED is OFF, refer to “Troubleshooting” on page 27.
9. The management module is now ready to be configured. Proceed to
Chapter 3 for instructions on how to configure the management module.
6
AT-MCM02 Management Module Installation Guide

Management LEDs

Table 1 lists the LEDs located in the Management section on the front panel of the media converter.
Table 1 Management LEDs
LED Status Definition
LNK ON A link has been established between the management
module and the hub, switch, or management station to which it is connected.
OFF No link has been est ablished. REC ON The module is receiving data. Ready ON The management module has been installed and configured.
Flashing The management module has been installed but has not
been configured.
OFF Either the management module has not b een installed or it
has been installe d incorrectly.
Note
For information on the other LEDs on the media converter, refer to the media converter’s installation guide.
7

Chapter 3

Configuring the Management Module

After you have installed the AT-MCM02 Management Module in the media converter, you must assign it an IP address, a subnet mask, and a gateway address. You must also connect the management module to the network.
Note
You must perform this procedure if you intend to manage the media converter using Telnet or SNMP. This procedure is not necessary if you will be managing the media converter only through the RS-232 port on the front panel of the media converter.
To configure the management module, perform the following procedure:
1. Connect the miniDIN end of the control cable to the Management RS-232 port on the front panel of the media converter.
2. Connect the other end of the control cable to a DB9 (male) connector on a terminal or a PC with a terminal emulation program.
3. Configure the terminal or the terminal emulation program to the following settings:
Baud rate: 38400Parity: NoneStart bits: 1Stop bits: 1Flow control: NoneEmulator: VT100
9
Once the terminal parameters have been set and after a delay of approximately 10 seconds, the following menu is displayed.
Boot MCM02 Version: 1.3.2 16-May-2001 Copyright 2000 by Allied Telesyn International, Inc.
---------------------------------------------------­Type any key for Boot Menu’
Initialization .....
Loading Program .....
---------------------------------------------------­MCM02 - Connected To: MCF 112 Version: 2.0.6 31-July-2001
---------------------------------------------------­Login:
Caution
The ‘Type any key for Boot Menu’ prompt is for manufacturing purposes only.
4. Select the Login field and in lowercase letters, enter: manager. (This field is case sensitive.)
5. Press <Return>.
A prompt is displayed for the password.
6. In lowercase letters, enter: ati. (The password is case sensitive.)
7. Press <Return>.
The ‘>’ prompt is displayed.
8. Use the SET IP INTERFACE command to configure the IP parameters for the management module. The format of the command is as follows:
SET IP INTERFACE=eth0 IPADDRESS=IPAddress MASK=SubnetMask GATEWAY=GatewayAddress
For example, if you wanted to set the management module to an IP address of 192.168.1.2, a subnet mask of 255.255.255.0, and a gateway address of
192.168.1.1, the command would be: SET IP INTERFACE=eth0 IPADDRESS=192.168.1.2
MASK=255.255.255.0 GATEWAY=192.168.1.1
10
AT-MCM02 Management Module Installation Guide
If you entered the command correctly, the ‘>’ prompt is displayed again. If you entered the command incorrectly, an error message is displayed, in which case you must re-enter the command.
9. Use the SET SNMP command to configure the community strings for the management module. The format of the command is as follows:
SET SNMP COMMUNITY GET=GetString SET=SetString TRAP=TrapString
For example, if you were to set the Get community string on the management module to public, the set community string to private, and the trap community string to trap, the command would be:
SET SNMP COMMUNITY GET=public SET=private TRAP=trap If you entered the command correctly, the ‘>’ prompt is displayed again. If
you entered the command incorrectly, an error message is displayed, in which case you must re-enter the command.
10. The basic parameters for the media converter have now been set. Proceed to the next section for instructions on cabling the management module.

Cabling the Management Module

To manage the media converter using Telnet or SNMP from a workstation on the network, do one of the following:
1. To manage the media converter from a remote network management station, connect a straight-through twisted pair cable with an RJ-45 connector from an Ethernet hub or switch to the Hub Management port on the media converter (see Figure 3). The end-node connected to the Hub Management port must be operating at 10Base or 10/100Base.
Note
The other end of the network cable should be connected to a 10Base-T port or a 10Base-T/100Base-TX port on a network hub or server.
11
2. To manage the media converter directly connected to a PC, use a straight­through cable to connect the Station Management port on the front panel of the media converter.
10Base-T
STATION HUBOR
MANAGEMENT
RS232
LNK REC
Ready
T-LNK F-LNK Active
Tx Rx Tx Rx Tx Rx Tx Rx Tx RxTx Rx
1
2
3
4
Tx Rx Tx Rx Tx Rx Tx Rx Tx RxTx Rx
7
8
9
5
10
11
1-6 LINK TEST
NORM
100Base-TX/FX Media Converter
MCF112SC
TEST
RESET
6
12
NORM
TEST
7-12 LINK TEST
RESET
LNK REC
Ready
10Base-T
MANAGEMENT
STATION HUB
OR
POWER
BCKP
MAIN
RS232
Figure 3 Management Ports
3. After you have connected the Hub or Station Management port to the network, check the Management LNK LED on the front panel of the media converter. The LED should be ON. This indicates that the Hub port on the media converter has established a link with the port on the hub or switch to which it is connected. You should also check the appropriate port link LED on the hub or switch to be sure that it is also ON.
4. If you will be using an SNMP management program to manage the media converter, go to “Loading the MIB File” for further instructions. Otherwise, proceed to Chapter 4.

Loading the MIB File

If you intend to manage the media converter from a management station using an SNMP management program, you need to load the MIB file onto the management station.
Note
The MIB file is available from the Allied Telesyn web site at www.alliedtelesyn.com.
Downloading the MIB file requires that you use a MIB compiler to compile the file. You only need to load the MIB file once on a management station, regardless of the number of AT-MCF Series Media Converters on your network. To load the MIB file onto a management station, follow the instructions included with your MIB compiler.
12

Chapter 4

Managing a Multichannel Media Converter

After installing an AT-MCM02 Management Module, you can manage an AT-MCF Series Media Converter in one of three ways. They are:
RS-232 PortTelnet ProgramSNMP Management Program

RS-232 Port

You can manage the media converter through the RS-232 port by connecting to a terminal or a PC with a terminal emulation program using the control cable. Configure the terminal or terminal emulation program to the following settings:
Baud rate: 38400Parity: NoneStart bits: 1Stop bits: 1Flow control: noneEmulator: VT100
To start a management session, you must login. The login name is manager and the password is ati. (The login name and password are case sensitive.) Once you have logged in, the “>” command prompt is displayed. For information on the commands, refer to the section “Management Commands” on page 15.
13

Telnet Application Protocol

Telnet allows you to configure the AT-MCM02 Management Module from a local or remote workstation on your network. To manage the media converter with Telnet, the media converter must already have an IP address and subnet mask assigned. Refer to “SET IP INTERFACE Command” on page 16 for instructions on assigning an IP address and subnet mask. You will also need to connect one of the Management ports on the media converter to the network or directly to the workstation. Refer to “Cabling the Management Module” on page 11 for further instructions.
A Telnet management session on a media converter is similar to starting a session from the RS-232 port. You first login by entering the login name manager and the password ati. (The login name and password are case sensitive.) Once you have logged in, the “>” command prompt is displayed. For information on the commands, refer to the section “Management Commands” on page 15.
Note
You cannot have both a RS-232 management session and a Telnet management session running at the same time on a media converter. The management module will only allow one management session at a time.

SNMP Management Program

Another method for managing a media converter is with an SNMP management program from a workstation on your network. This management method requires that you assign the media converter an IP address, as explained earlier in this chapter, and that you connect the management ports on the media converter to the network or directly to a management workstation, as explained in “Configuring the Management Module” on page
9. Finally, you must load the MIB objects onto the workstation, as explained
in “Loading the MIB File” on page 12.
Once the MIB objects have been loaded on the workstation, you can use your SNMP management program to examine the values for the objects on the media converter. For instructions on using your SNMP program, refer to the documentation that came with the program.
14
AT-MCM02 Management Module Installation Guide

Management Commands

Table 2 lists the management commands.
Table 2 Management Commands
Command Function Page IP Commands
SET IP INTERFACE Sets the IP address, gateway address, and
subnet mask.
SHOW IP INTERFACE Displays the IP address, gateway address, and
subnet mask.
System Commands
SET SYSTEM Sets the system name, loc ation, and contact. 17 SHOW SYSTEM Displays the system name, location, and
contact.
SNMP Commands
SET SNMP COMMUNITY Sets the G et, Set, and Trap community strings. 18 SET SNMP MANAGER S ets the IP address of a management station
to receive traps from the medi a converter.
SHOW SNMP Displays the current community strings on the
media conve r t e r .
MC Commands
SHOW MC CHANNEL Displays the current status of a specific
channel.
SET MC MODE Starts or stops a link test on the ports of the
channels.
RESET MC CHANNEL Resets the channels. 22
16
17
18
19
20
20
21
LOADER Commands
SET LOADER Downloads a new version of the operating
software onto the media converter.
SHOW LOADER Displays the current device specifications for
downloading the operating softwar e.
RESTART REBOO T Reboots the media converter. 25
24
24
15

IP Commands

The AT-MCM02 Management Module has two commands for setting and viewing the IP address, subnet mask, and gateway address of the media converter. The commands are:
SET IP INTERFACESHOW IP INTERFACE

SET IP INTERFACE Command

This command allows you to set the IP address, subnet mask, and gateway address for the media converter. You must perform this command if you intend to manage the media converter using Telnet or an SNMP management program. This command is not necessary if you will be managing the media converter using only the RS-232 management port on the unit.
Format:
SET IP INTERFACE=eth0 IPADDRESS=IPAddress MASK=SubnetMask GATEWAY=GatewayAddress
Variables:
IPAddress: Specifies the IP address for the media converter. SubnetMask: Specifies the subnet mask. GatewayAddress: Specifies the gateway address.
Examples:
The following example sets the management module to an IP address of
192.168.1.2, a subnet mask of 255.255.255.0, and a gateway address of
192.168.1.1: SET IP INTERFACE=eth0 IPADDRESS=192.168.1.2
MASK=255.255.255.0 GATEWAY=192.168.1.1 The parameters can be changed individually. The following example
changes only the gateway addresses: SET IP INTERFACE=eth0 GATEWAY 192.168.10.7
16
AT-MCM02 Management Module Installation Guide

SHOW IP INTERFACE Command

This command displays the current IP parameters of the media converter.
Format:
SHOW IP INTERFACE

SYSTEM Commands

The AT-MCM02 has two commands for setting and viewing the system name, location and contact. The commands are:
SET SYSTEMSHOW SYSTEM

SET SYSTEM Comman d

This command allows you to specify a name for the system. Assigning names to the media converters can make it easier for you to identify the individual units in your network. The media converter name is displayed as part of the “>” command prompt whenever you manage the device through the RS-232 port or when using Telnet. You can also specify the location of a device and the name of the network manager responsible for managing the unit.
Format:
SET SYSTEM NAME=”name” LOCATION=”location” CONTACT=”contact
Variables:
name: Specifies a name (one word up to 50 characters) for the media converter.
location: Specifies the location (one word up to 50 characters) of the media converter.
contact: Specifies the name (one word up to 50 characters) of the network administrator responsible for managing the media converter.
17
Examples:
The following example assigns the media converter the name of “MC112Sales,” and gives its location and contact as “BuildingFour” and “JohnSmith,” respectively.
SET SYSTEM NAME=”MC112Sales” LOCATION=”BuildingFour” CONTACT=”JohnSmith”
You can also set the information individually. The following example sets just the location variable:
SET SYSTEM LOCATION=”FifthFloor”

SHOW SYSTEM Command

This command displays the name, location, and contact of the media converter.
Format:
SHOW SYSTEM

SNMP Commands

The AT-MCM02 management module provides several commands for setting and displaying the SNMP community strings on the media converter. The commands are:
SET SNMP COMMUNITYSET SNMP MANAGERSHOW SNMP

SET SNMP COMMUNITY Command

This command is used to set the Set, Get, and Trap community strings on the media converter.
Format:
SET SNMP COMMUNITY SET=SetString GET=GetString TRAP=TrapString
18
AT-MCM02 Management Module Installation Guide
Variables:
SetString: Specifies the Set community string for the media converter. GetString: Specifies the Get community string for the media converter. TrapString: Specifies the Trap community string of the management
station to receive traps from the media converter.
Examples:
The following command sets the Get string to public, the Set string to private, and the Trap string to trap:
SET SNMP COMMUNITY GET=public SET=private TRAP=trap You can also set the community strings individually. The following
example sets the Get string to Restricted: SET SNMP COMMUNITY GET=restricted

SET SNMP MANAGER Command

This command is used to specify the IP address of a management station that is to receive traps from the media converter.
Format:
SET SNMP MANAGER=IPAddress
Variable:
IPAddress: Specifies the IP address of the management station to receive traps.
Example:
The following example specifies the IP address of the management station as 192.10.10.10:
SET SNMP MANAGER=192.10.10.10
19

SHOW SNMP Command

This command displays the current Set, Get, and Trap community strings on the media converter. This command also displays the IP address of the management station currently assigned to receive traps from the media converter.
Format:
SHOW SNMP

MC Commands

The MC commands are used to start and stop link tests on the channels on the media converter and to reset channels. The commands are:
SHOW MC CHANNELSET MC MODERESET MC CHANNEL

SHOW MC CHANNEL Command

This command displays the status of the twisted pair and fiber optic ports of the individual channels on the media converter. The information includes whether a link exists on the ports, whether there is activity on the ports, and whether the channel is performing a link test. This command also displays the operating temperature of the unit.
Format:
SHOW MC CHANNEL=n
Variable:
n: Specifies the number of the channel. For an AT-MCF06 or AT-MCF106 media converter, the value can be 1 to 6. Fo r an AT-MCF12 or AT-MCF112 media converter, the value can be 1 to 12.
Example:
The following example displays the status of all the ports on the media converter:
20
AT-MCM02 Management Module Installation Guide
SHOW MC To display the status of just one port, use the CHANNEL variable. For
example, the following command displays the status of the ports in channel 4:
SHOW MC CHANNEL=4 The TP Link and FO Link columns indicate whether the twisted pair and
fiber optic ports have a valid connection to the end nodes connected to the ports. The ON status indicates the presence of a valid link while OFF indicates the absence of a link. The TP Act and FO Act columns indicate if there is any activity on the ports. The Test column indicates whether the channels are performing a link test, indicated by “Enable,” or are in the normal operating mode, indicated by “Disable.”

SET MC MODE Command

This command allows you to override the Link Test switch on the front panel of the media converter and either start or stop a link test on the channels of the unit.
Note
A link test on an AT-MCF06 or AT-MCF12 media converter should be performed with caution. The media converter will not pass network traffic when performing a link test.
Format:
SET MC MODE=state CHANNELS=row
Variables:
state: Starts or stops a link test. Possible values are: TEST - Starts a link test. NORMAL - Stops a link test. row: Specifies the channels on which to start or stop a link test. Possible
values are: 1TO6 - Starts or stops a link test on channels 1 to 6. 7TO12 - Starts or stops a link test on channels 7 to 12.
21
Examples:
The following example starts a link test on all the channels on the unit: SET MC MODE=TEST If you are managing an AT-MCF106 or AT-MCF112 media converter, you
can specify a specific row of converters on which to start or stop a link test rather than all channels. The variables “1TO6” and “7TO12” allow you to specify the channel row. The following example starts a link test on channels 7 to 12:
SET MC MODE=TEST CHANNELS=7TO12
Note
You cannot perform a link test on an individual channel.
The following example stops a link test on all channels: SET MC MODE=NORMAL

RESET MC CHANNEL Command

This command can be used to reset the channels on a media converter.
Note
Resetting a media converter should be performed with caution. Network operations of the channels will be briefly interrupt during the reset process.
Format:
RESET MC CHANNELS=row
Parameter:
row: Specifies the row of channels on the media converters to reset. Possible values are:
1TO6 - Resets channels 1 to 6 7TO12 - Resets channels 7 to 12
22
AT-MCM02 Management Module Installation Guide
Examples:
The following example resets all of the channels on the media converter: RESET MC The reset process takes only a second or two, after which the media
converter is ready again for normal network operations. If you are managing an AT-MCF12 or AT-MCF112, you can use the
RESET MC CHANNEL command to reset a specific row of channels, rather than all the channels. The variables “1TO6” and “7TO12” allow you to specify which row to reset. The following example resets channels 7 to 12:
RESET MC CHANNELS=7TO12
Note
You cannot reset just one channel on a media converter. You must reset the entire unit or, in the case of an AT-MCF12 or AT-MCF112 unit, a row of channels.

LOAD Commands

The management module provides several commands for downloading a new version of the operating software onto the media converter. The commands are:
SET LOADERSHOW LOADERRESTART REBOOT
Note
The software for the AT-MCF Series Media Converters is available from the Allied Telesyn web site at www.alliedtelesyn.com.
23

SET LOADER Command

This command downloads a new version of the software onto the media converter. It is required that your network has a TFTP server and that you have downloaded the new software to the server.
Format:
SET LOADER FILE=filename SERVER=IPaddress
Variables:
filename: Specifies the path and filename of the file containing the media converter software. The default filename is atmcm02.bin.
IPaddress: Specifies the IP address of the network server or workstation containing the new software.
Example:
In the following example, the filename of the software is atmcm02.bin and the IP address of the network device containing the software is
192.11.11.12: SET LOADER FILE=atmcm02.bin SERVER=192.11.11.12
Note
You must perform the RESTART REBOOT command immediately after you download a new version of the software. The command is described on page 25.

SHOW LOADER Command

This command displays information used in downloading a new version of the operating software onto a media converter. The information includes:
The method by which the new software will be downloaded onto the
media converter.
The filename of the software.The destination of the software, which is always flash ROM.The IP address of the network device containing the new software.
24
AT-MCM02 Management Module Installation Guide
Format:
SHOW LOADER
Example:
SHOW LOADER

RESTART REBOOT Command

The RESTART REBOOT command must be performed whenever you download a new version of the operating software on a media converter.
Format:
RESTART REBOOT
Example:
The following command reboots the media converter: RESTART REBOOT
25

Chapter 5

Troubleshooting

This section contains guidelines for troubleshooting the management module in the event a problem occurs.
If the BCKUP or MAIN LED is OFF:
Remove and reinstall the AT-MCM02 management module.
If the Ready LED is OFF:
Reconfigure the management module by performing the procedure in
Chapter 3 on page 9.
If there is no SNMP response from the management module:
Verify that the management module has been connected to the
network, as explained in the procedure Chapter 3 on page 9.
Verify that the management station has been connected to the
network.
Check the IP address of the management module by performing the
SHOW IP INTERFACE command.
If no traps are being received by a management station:
Re-enter the IP address for the management station by performing the
procedure Chapter 3 on page 9.
If you are still experiencing problems after testing and troubleshooting the installation, contact Allied Telesyn Technical Support for assistance. Refer to “Contacting Allied Telesyn” on page viii or visit our web site at www.alliedtelesyn.com for support information.
27

Warranty Registration

When you have finished installing the product, you should register your product by completing the enclosed warranty card and sending it in. You can also visit our web site at www.alliedtelesyn.com/forms/warranty.htm and fill out the registration online.
28

Appendix A

Translated Safety Statements

Important: This appendix contains multiple-language translations for the safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues des instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli avvi si di sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av sikkerhetsinformasjonen i denne veiledningen.
Importante: E ste ane xo contém traduç ões em vár ios idio mas das a dvertên cias de segurança neste guia.
Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av säkerhetsmeddelandena i denna handledning.
29
Standards: This product meets the following standards:
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference­Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
$
1 RFI Emission EN55022 Class A
$
2 Warning: In a domestic environment this product may cause radio interference in
$
3 Immunity EN50082-1 1997
$
4 Electrical Safety EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Warning: Class 1 Laser product.
$
7 Warning: Do not stare into the laser beam.
$
8 ELECTRICAL NOTICES
$
9 LIGHTNING DANGER
$
10 Caution: POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-
$
11 PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment
$
12 Caution: Air vents must not be blocked and must have free access to the room
which case the user may be required to take adequate measures.
SAFETY
Warning: ELECTRIC SHOCK HAZARD
To prevent ELECTRIC shock, do not remove the cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting the LAN cables.
Danger: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY.
ENERGIZE EQUIPMENT, disconnect the power cord.
and shall be easily accessible.
ambient air for cooling.
30
AT-MCM02 Management Module Installation Guide
$
13 Operating Temperature: This product is designed for a maximum ambient
$
14 All CountrieS: Install product in accordance with local and National Electrical Codes.
$
15 Warning: When installing this equipment, always ensure that the frame ground
$
1 Hochfrequenzstörung EN55022 Klasse A
$
2 Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
$
3 Störsicherheit EN50082-1
$
4 Elektrische Sicherheit EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Warnung Laserprodukt der Klasse 1.
$
7 Warnung Nicht direkt in den Strahl blicken.
$
8 Achtung: GEFÄHRLICHE SPANNUNG
$
9 GEFAHR DURCH BLITZSCHLAG
$
10 Vorsicht: DAS NETZKABEL DIENT ZUM TRENNEN DER STROMVERSORGUNG.
$
11 STECKBARES GERÄT: Die Anschlußbuchse sollte in der Nähe der Einrichtung
$
12 Vorsicht
$
13 Betriebstemperatur: Dieses Produkt wurde für den Betrieb in einer
$
14 Alle Länder: Installation muß örtlichen und nationalen elektrischen Vorschriften
$
15 Warnung: Bei der Installation dieser Einrichtung ist stets sicherzustellen, daß der
temperature of 40° degrees C.
connection is installed first and disconnected last.
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
SICHERHEIT
Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen.
Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters ausführen.
ZUR TRENNUNG VOM NETZ, KABEL AUS DER STECKDOSE ZIEHEN.
angebracht werden und leicht zugänglich sein."
Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum Kühlen freien Zugang zur Raumluft haben.
Umgebungstemperatur von nicht mehr als 40° C entworfen.
entsprechen.
Masseanschluß jeweils zuerst installiert und zuletzt getrennt wird.
31
Standarder: Dette produkt tilfredsstiller de følgende standarder.
$
1 Radiofrekvens forstyrrelsesemission EN55022 Klasse A
$
2 Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver
$
3 Immunitet EN50082-1
$
4 Elektrisk sikkerhed EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Advarsel Laserprodukt av klasse 1.
$
7 Advarsel Stirr ikke på strålen.
$
8 ELEKTRISKE FORHOLDSREGLER
$
9 FARE UNDER UVEJR
$
10 Advarsel: DEN STRØMFØRENDE LEDNING BRUGES TIL AT AFBRYDE
$
11 UDSTYR TIL STIKKONTAKT, stikkontakten bør installeres nær ved udstyret og skal
$
12 Advarsel: Ventilationsåbninger må ikke blokeres og skal have fri adgang til den
$
13 Betjeningstemperatur: Dette apparat er konstrueret til en omgivende temperatur
$
14 Alle Lande: Installation af produktet skal ske i overensstemmelse med lokal og
$
15 Advarsel: Ved installering af dette udstyr skal steljord altid forbindes først og aftages
det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
Sikkerhed
Advarsel: RISIKO FOR ELEKTRISK STØD
For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
Fare: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVITET.
STRØMMEN. SKAL STRØMMEN TIL APPARATET AFBRYDES, tages ledningen ud af stikket.
være lettilgængelig.
omgivende luft i rummet for afkøling.
på maksimum 40 grader C.
national lovgivning for elektriske installationer.
sidst.
32
AT-MCM02 Management Module Installation Guide
Eisen: Dit product voldoet aan de volgende eisen.
$
1 RFI Emissie EN55022 Klasse A
$
2 Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval
$
3 Immuniteit EN50082-1
$
4 Electrische Veiligheid EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Waarshuwing Klasse-1 laser produkt.
$
7 Waarchuwing Neit in de straal staren.
$
8 WAARSCHUWINGEN MET BETREKKING TOT ELEKTRICITEIT
$
9 GEVAAR VOOR BLIKSEMINSLAG
$
10 Waarschuwing: HET TOESTEL WORDT UITGESCHAKELD DOOR DE
$
11 AAN TE SLUITEN APPARATUUR, de contactdoos wordt in de nabijheid van de
$
12 Opgelet: De ventilatiegaten mogen niet worden gesperd en moeten de omgevingslucht
$
13 Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag niet meer
$
14 Alle Landen: het toestel installeren overeenkomstig de lokale en nationale
$
15 Waarschuwing: Zorg er tijdens installatie van de apparatuur altijd voor dat de
de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
Veiligheid
Waarschuwing: GEVAAR VOOR ELEKTRISCHE SCHOKKEN
Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen. Binnenin bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden. Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door een daartoe opgeleide en bevoegde technicus. Om het gevaar op ELEKTRISCHE SCHOKKEN te vermijden, moet u het toestel van de stroombron ontkoppelen alvorens de LAN-kabels te koppelen of ontkoppelen.
Gevaar: NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
STROOMKABEL TE ONTKOPPELEN.OM HET TOESTEL STROOMLOOS TE MAKEN: de stroomkabel ontkoppelen.
apparatuur geïnstalleerd en is gemakkelijk te bereiken."
ongehinderd toelaten voor afkoeling.
bedragen dan 40 graden Celsius.
elektrische voorschriften.
aardeaansluiting van het frame als eerste wordt geplaatst en als laatste wordt losgemaakt.
33
Normes: ce produit est conforme aux normes de suivantes:
$
1 Emission d’interférences
$
2 Mise En Garde: dans un environnement domestique, ce produit peut provoquer des
$
3 Immunité EN50082 - 1
$
4 Sécurité électrique EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Attention Producit laser di classe 1.
$
7 Attention Ne pas fixer le faisceau des yeux.
$
8 INFORMATION SUR LES RISQUES ÉLECTRIQUES
$
9 DANGER DE FOUDRE
$
10 Attention: LE CORDON D’ALIMENTATION SERT DE MISE HORS CIRCUIT.
$
11 EQUIPEMENT POUR BRANCHEMENT ELECTRIQUE, la prise de sortie doit être
$
12 Attention: Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant de
$
13 Température De Fonctionnement: Ce matériel est capable de tolérer une
$
14 Pour Tous Pays: Installer le matériel conformément aux normes électriques
$
15 Avertissement: Lors de l’installation de cet équipement, vérifiez toujours que la
radioélectriques EN55022 Classe A
interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
Sécurité
Avertissement: DANGER D’ÉLECTROCUTION Pour éviter toute
ÉLECTROCUTION, ne pas ôter le revêtement protecteur du matériel. Ce matériel ne contient aucun élément réparable par l’utilisateur. Il comprend des TENSIONS DANGEREUSES et ne doit être ouvert que par un technicien dûment qualifié. Pour éviter tout risque d’ÉLECTROCUTION, débrancher le matériel avant de connecter ou de déconnecter les câbles LAN.
Danger: NE PAS MANIER le matériel ou les CÂBLES lors d’activité orageuse.
POUR COUPER L’ALIMENTATION DU MATÉRIEL, débrancher le cordon.
placée près de l’équipement et facilement accessible".
circuler librement pour le refroidissement.
température ambiante maximum de ou 40 degrés Celsius.
nationales et locales.
connexion de terre du châssis est installée en premier et débranchée en dernier.
34
AT-MCM02 Management Module Installation Guide
Standardit: Tämä tuote on seuraavien standardien mukainen.
$
1 Radioaaltojen häirintä EN55022 Luokka A
$
2 Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä
$
3 Kestävyys EN50082-1
$
4 Sähköturvallisuus EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Varoitus Luokan 1 Lasertuote.
$
7 Variotus Älä katso säteeseen.
$
8 SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA
$
9 SALAMANISKUVAARA
$
10 Huomautus: VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA.
$
11 Pistorasiaan Kytkettävä Laite; pistorasia on asennettava laitteen lähelle ja siihen
$
12 Huomautus: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys
$
13 Käyttölämpötila: Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle
$
14 Kaikki Maat: Asenna tuote paikallisten ja kansallisten sähköturvallisuusmääräysten
$
15 Varoitus: Kun asennat tätä laitetta, varmista aina, että runkomaadoitettu liitin
tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
Turvallisuus
Varoitus: SÄHKÖISKUVAARA Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä
ei ole käyttäjän huollettavissa olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden katkaise sähkövirta tuotteeseen ennen kuin liität tai irrotat paikallisverkon (LAN) kaapelit.
Hengenvaara: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA.
VIRTA KATKAISTAAN irrottamalla virtajohto.
on oltava esteetön pääsy."
ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.
40°C.
mukaisesti.
kytketään ensin ja irrotetaan viimeiseksi.
35
Standard: Questo prodotto è conforme ai seguenti standard.
$
1 Emissione RFI (interferenza di
$
2 Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio
$
3 Immunità EN50082-1
$
4 Sicurezza elettrica EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Avvertenza Prodotto laser di Classe 1.
$
7 Avertenza Non fissare il raggio con gli occhi.
$
8 AVVERTENZE ELETTRICHE
$
9 PERICOLO DI FULMINI
$
10 Attenzione: IL CAVO DI ALIMENTAZIONE È USATO COME DISPOSITIVO DI
$
11 Apparecchiatura Collegabile, la presa va installata vicino all’apparecchio per
$
12 Attenzione: le prese d’aria non vanno ostruite e devono consentire il libero ricircolo
$
13 Temperatura Di Funzionamento: Questo prodotto è concepito per una temperatura
$
14 Tutti I Paesi: installare il prodotto in conformità delle vigenti normative elettriche
$
15 Avvertenza: Quando si installa questo apparecchio, accertarsi sempre che il
radiofrequenza) EN55022 Classe A
interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
Norme Di Sicurezza
Attenzione: PERICOLO DI SCOSSE ELETTRICHE
Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato. Per evitare ogni possibilità di SCOSSE ELETTRICHE, interrompere l’alimentazione del dispositivo prima di collegare o staccare i cavi LAN.
Pericolo: NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI TEMPORALESCHE.
DISATTIVAZIONE. PER TOGLIERE LA CORRENTE AL DISPOSITIVO staccare il cavo di alimentazione.
risultare facilmente accessibile".
dell’aria ambiente per il raffreddamento.
ambientale massima di 40 gradi centigradi.
nazionali.
collegamento a massa del telaio sia sempre il primo ad essere effettuato e l’ultimo ad essere scollegato.
36
AT-MCM02 Management Module Installation Guide
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
$
1 RFI stråling EN55022 Klasse A
$
2 Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake
$
3 Immunitet EN50082-1
$
4 Elektrisk sikkerhet EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Advarsel Laserprodukt av klasse 1.
$
7 Advarsal Stirr ikke på strålen.
$
8 ELEKTRISITET
$
9 FARE FOR LYNNEDSLAG
$
10 Forsiktig: STRØMLEDNINGEN BRUKES TIL Å FRAKOBLE UTSTYRET. FOR Å
$
11 Utstyr For Stikkontakt. Stikkontakten skal monteres i nærheten av utstyret og skal
$
12 Forsiktig: Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med
$
13 Driftstemperatur: Dette produktet er konstruert for bruk i maksimum
$
14 Alle Land: Produktet må installeres i samsvar med de lokale og nasjonale elektriske
$
15 Advarsel: Når du monterer dette utstyret, skal du alltid passe på at forbindelsen til
radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Sikkerhet
Advarsel: FARE FOR ELEKTRISK SJOKK
For å unngå ELEKTRISK sjokk, må dekslet ikke tas av. Det finnes ingen deler som brukeren kan reparere på innsiden. Denne enheten inneholder FARLIGE SPENNINGER, og må kun åpnes av en faglig kvalifisert tekniker. For å unngå ELEKTRISK SJOKK må den elektriske strømmen til produktet være avslått før LAN­kablene til- eller frakobles.
Fare: ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
DEAKTIVISERE UTSTYRET, må strømforsyningen kobles fra.
være lett tilgjengelig."
romtemperatur for avkjøling.
romtemperatur på 40 grader celsius.
koder.
rammejordingen monteres først og koples fra sist.
37
Padrões: Este produto atende aos seguintes padrões.
$
1 Emissão De Interferência De RadiofrequênciaEn55022 Classe A
$
2 Aviso: Num ambiente doméstico este produto pode causar interferência na
$
3 Imunidade EN50082-1
$
4 Segurança Eléctrica EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Aviso Produto laser de classe 1
$
7 Aviso Não olhe fixamente para o raio.
$
8 AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS
$
9 PERIGO DE CHOQUE CAUSADO POR RAIO
$
10 Cuidado: O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM DISPOSITIVO
$
11 Equipamento De Ligação, a tomada eléctrica deve estar instalada perto do
$
12 Cuidado: As aberturas de ventilação não devem ser bloqueadas e devem ter acesso
$
13 Temperatura De Funcionamento: Este produto foi projetado para uma
$
14 Todos Os Países: Instale o produto de acordo com as normas nacionais e locais para
$
15 Aviso: Ao ligar este equipamento, instale sempre primeiro a ligação à terra e desligue-
radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Segurança
Atenção: PERIGO DE CHOQUE ELÉTRICO
Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico qualificado e treinado. Para evitar a possibilidade de CHOQUE ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os cabos da LAN.
Perigo: NÃO TRABALHE no equipamento ou nos CABOS durante períodos suscetíveis a QUEDAS DE RAIO.
DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO, desconecte o cabo de ALIMENTAÇÃO.
equipamento e ser de fácil acesso."
livre ao ar ambiente para arrefecimento adequado do aparelho.
temperatura ambiente máxima de 40 graus centígrados.
instalações elétricas.
a sempre em último.
38
AT-MCM02 Management Module Installation Guide
Estándares: Este producto cumple con los siguientes estándares.
$
1 Emisión RFI EN55022 Clase A
$
2 Advertencia: en un entorno doméstico, este producto puede causar
$
3 Inmunidad EN50082-1
$
4 Seguridad eléctrica EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 ¡Advertencia! Producto láser Clase 1.
$
7 ¡Advertencia! No mirat fijamente el haz.
$
8 AVISOS ELECTRICOS
$
9 PELIGRO DE RAYOS
$
10 Atencion: EL CABLE DE ALIMENTACION SE USA COMO UN
$
11 Equipo ConectablE, el tomacorriente se debe instalar cerca del equipo, en un lugar
$
12 Atencion: Las aberturas para ventilación no deberán bloquearse y deberán tener
$
13 Temperatura Requerida Para La Operación: Este producto está diseñado para
$
14 Para Todos Los Países: Monte el producto de acuerdo con los Códigos Eléctricos
$
15 Advertencia: Cuando instale dicho equipo, asegúrese siempre de que el bastidor se
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
Seguridad
Advertencia: PELIGRO DE ELECTROCHOQUE
Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un técnico entrenado y calificado. Para evitar la posibilidad de ELECTROCHOQUE desconecte la corriente eléctrica que llega al producto antes de conectar o desconectar los cables LAN.
Peligro: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos o en LOS CABLES durante TORMENTAS ELECTRICAS.
DISPOSITIVO DE DESCONEXION. PARA DESACTIVAR EL EQUIPO, desconecte el cable de alimentación.
con acceso fácil".
acceso libre al aire ambiental de la sala para su enfriamiento.
una temperatura ambiental máxima de 40 grados C.
locales y nacionales.
conecte a tierra primero y se desconecte por último.
39
Standarder: Denna produkt uppfyller följande standarder.
$
1 Radiostörning EN55022 Klass A
$
2 Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan
$
3 Immunitet EN50082-1
$
4 Elsäkerhet EN60950, UL1950, CSA 950
$
5 Laser EN60825
$
6 Varning! Laserprodukt av klass 1.
$
7 Varning! Laserstrålning när enheten är öppen.
$
8 TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK:
$
9 FARA FÖR BLIXTNEDSLAG
$
10 Varning: NÄTKABELN ANVÄNDS SOM STRÖMBRYTARE FÖR ATT KOPPLA
$
11 Utrustning Med Plugg. Uttaget skall installeras i utrustningens närhet och vara
$
12 Varning: Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande
$
13 Driftstemperatur: Denna produkt är konstruerad för rumstemperatur ej
$
14 Alla Länder: Installera produkten i enlighet med lokala och statliga bestämmelser
$
15 Varning: Vid anslutning av denna utrustning skall man alltid se till att jordtråden
tvinga användaren till att vidtaga erforderliga åtgärder.
Säkerhet
RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas. Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LAN­kablarna ansluts eller kopplas ur.
Fara: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
FRÅN STRÖMMEN, dra ur nätkabeln.
lättåtkomligt".
rumsluft för avsvalning.
överstigande 40 grader Celsius.
för elektrisk utrustning.
ansluts först och lossas sist.
40

Appendix B

Technical Support Fax Order

Name _________________________________________________________________ Company______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code _________________ Country_______________________________ Phone______________________________ Fax_______________________________

Incident Summary

Model number of Allied Telesyn product I am using _______________________ Firmware release number of Allied Telesyn product _______________________ Other network software products I am using (e.g., network managers)
______________________________________________________________________ ______________________________________________________________________
Brief summary of problem ______________________________________________
______________________________________________________________________
Conditions (List the steps that led up to the problem.) _____________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
______________________________________________________________________ Detailed description (Please use separate sheet) Please also fax printouts of relevant files such as batch files and configuration
files. When completed, fax this sheet to the appropriate Allied Telesyn office. Fax numbers can be found on page viii.
41