Alarm Controls 1200S, 1200SDURO Installation Manual

0 (0)

MAGNETIC LOCK INSTALLATION INSTRUCTIONS

PLEASE READ BEFORE INSTALLATION

ALARM CONTROLS CORPORATION OFFERS A COMPLETE LINE OF MAGNETIC LOCKS AND ACCESSORY ITEMS TO ASSIST THE INSTALLER IN MANAGING EVERY APPLICATION.

THE MAGNETIC LOCK IS DESIGNED TO MOUNT TO THE DOOR FRAME ON THE STOP SIDE OF THE DOOR IN A TYPICAL OUTSWINGING DOOR INSTALLATION,(SEE PAGE 2 FOR INSWINGING DOOR INSTALLATION). SUFFICIENT HEADER SPACE MUST BE AVAILABLE TO MOUNT THE MAGNETIC LOCK TO INSURE A SAFE AND SECURE INSTALLATION.

1.NOTE TYPE OF DOOR FRAME HEADER AND INSTALL FILLER PLATE OR ANGLE BRACKET AS REQUIRED TO PROVIDE A FLAT MOUNTING SURFACE ON THE DOOR HEADER THE ENTIRE LENGTH OF THE MAGNETIC LOCK.

OUTSWINGING DOOR INSTALLATION

 

HEADER

 

ANGLE

 

PLATE

 

 

FILLER

BRACKET

 

 

HEADER

HEADER

PLATE

HEADER

OUT

MAGNET

OUT

MAGNET

OUT

MAGNET

SWINGING

SWINGING

SWINGING

 

 

 

DOOR

ARMATURE

DOOR

 

DOOR

 

 

 

ARMATURE

 

ARMATURE

 

PLATE

 

PLATE

 

PLATE

2.FOLD TEMPLATE ON DOTTED LINE TO FORM A 90 DEGREE ANGLE. TAPE TEMPLATE AGAINST DOOR HEADER WITH DOOR IN A CLOSED POSITION 1” FROM DOOR FRAME OPPOSITE HINGE SIDE OF DOOR JAMB.

FOR A PAIR OF DOUBLE DOORS PLACE TEMPLATE AT THE CENTER OF THE DOOR OPENING. TRANSFER HOLE LOCATIONS TO DOOR AND FRAME HEADER, (SEE TEMPLATE INSTRUCTIONS).

3. FOLLOW TEMPLATE INSTRUCTIONS FOR HOLE SIZES. USE THE ILLUSTRATIONS BELOW TO DETERMINE THE PROPER HOLE PREPARATION FOR THE ARMATURE PLATE ACCCORDING TO THE DOOR TYPE IN THE INSTALLATION.

THE INCLUDED HARDWARE PACKAGE CONTAINS ALL NECESSARY ITEMS TO COMPLETE THE INSTALLATION.

TO REMOVE THE HEADER PLATE INSERT HEX KEY INTO HOLES LOCATED AT

THE BOTTOM OF LOCK ON THE RIGHT AND LEFT SIDE AND UN-SCREW THE CAP SCREWS

 

SOLID DOOR

STEP 2

STEP 1

FOLLOW WITH

DRILL 1/4” DIA.

1/2” DIA. HOLE

HOLE THRU

THRU DOOR

ARMATURE

 

SIDE OF DOOR

 

ARMATURE

 

PLATE MUST

 

ROCK ON DOOR

 

 

 

HOLLOW DOOR

STEP 2

STEP 1

DRILL 1/2” DIA.

DRILL 21/32” DIA.

HOLE THRU SEX

HOLE THRU

BOLT SIDE

ARMATURE

OF DOOR

SIDE OF DOOR

ONE THICKNESS

ONE THICKNESS

ONLY

ONLY

 

ARMATURE

 

PLATE MUST

 

ROCK ON DOOR

 

 

ALARM CONTROLS CORPORATION

19 BRANDYWINE DRIVE P.O. BOX 280

DEER PARK, NY 11729

800 645-5538 WWW.ALARMCONTROLS.COM

Alarm Controls 1200S, 1200SDURO Installation Manual

INSWINGING DOOR INSTALLATION WITH L- Z BRACKET

DOOR

FRAME

L

BRACKET

ADJUSTABLE Z BRACKET

STEP 1

FASTEN THE L BRACKET ON THE DOOR FRAME IN A SUITABLE LOCATION.

MOUNT THE MAGNETIC LOCK TO THE L BRACKET.

MAKE SURE THAT THE MAGNETIC LOCK DOES NOT OBSTRUCT THE CLOSING OF THE DOOR.

CONNECT THE CORRECT VOLTAGE TO THE MAGNET.

STEP 2

ASSEMBLE THE Z BRACKET WITH THE SOCKET HEAD CAP SCREWS PROVIDED. DO NOT TIGHTEN THE CAP SCREWS AT THIS TIME. THE Z BRACKET MUST BE ADJUSTABLE.

ARMATURE

METAL

BOLT

WASHERS

RUBBER

WASHER

ADJUSTABLE

SECTION OF

Z BRACKET WITH

ARMATURE PLATE

ATTACHED

Z BRACKET

ARMATURE

ASSEMBLY

COMPLETED

INSWINGING DOOR

INSTALLATION

STEP 3

MOUNT THE ARMATURE PLATE TO THE ADJUSTABLE SECTION OF THE Z BRACKET WITH THE ARMATURE BOLT. DO NOT REMOVE THE RUBBER WASHER ATTACHED TO THE ARMATURE BOLT.

USE ONE RUBBER WASHER BETWEEN TWO METAL WASHERS ON THE ARMATURE BOLT. THE WASHER ASSEMBLY MUST BE BETWEEN THE ARMATURE PLATE AND THE ADJUSTABLE SECTION OF THE Z BRACKET. APPLY THE SCREW LOCKING AGENT TO THE ARMATURE BOLT.

DO NOT OVER TIGHTEN. ARMATURE MUST ROCK TO ALIGN WITH THE MAGNET.

STEP 4

CLOSE THE DOOR AND ALIGN THE ARMATURE PLATE TO THE MAGNET AND APPLY POWER TO THE MAGNET. LET THE ARMATURE PLATE BOND TO THE MAGNET. BE SURE THE Z BRACKET ASSEMBLY IS FIRMLY

AGAINST THE CLOSED DOOR.

TIGHTEN THE CAP SCREWS HOLDING THE Z BRACKET ARMATURE PLATE ASSEMBLY.

FASTEN THE Z BRACKET ASSEMBLY TO THE DOOR WITH THE SCREWS SUPPLIED.

STEP 5

CHECK THE COMPLETED ALIGNMENT AND INSTALLATION OF THE MAGNET AND ARMATURE PLATE BY OPENING AND CLOSING THE DOOR BY ENERGIZING AND DE-ENERGIZING THE MAGNETIC LOCK SEVERAL TIMES.

THIS WILL INSURE THAT THE CORRECT OPERATION AND ALIGNMENT OF THE MAGNETIC LOCK HAS BEEN PROPERLY INSTALLED.