For more detailed docum en tati on, visit us online at www.adtran.com
TSU CSU ACE P/N 1202022L1
T1
CPE T1 Device
12-48V- - -
350 mA
PWR
T1
ETWORK CONNECTION PINOUT
N
Network
Pin Name Description
1 R1 RXDATA Receive data from the Network - Ring
2 T1 RXDATA Receive data from the Network - Tip
3, 6, 7, 8 UNUSED n/a
4 R TXDATA Transmit data towards the Network -
Ring
5 T TXDATA Transmit data towards the Network - Tip
CPE C
ONNECTION PINOUT
Pin Name Description
1 R TXDATA Transmit data towards the Network -
Ring
2 T TXDATA Transmit data towards the Network - Tip
3, 6, 7, 8 UNUSED n/a
4 R1 RXDATA Receive data from the Network - Ring
5 T1 RXDATA Receive data from the Network - Tip
NSTALLATION INFORMATION
I
• An eight-position modu lar ja ck (labe led N
ETWORK
) is provided to
connect to the ne twork T1 circuit. The pinout is provided on this Quick
Start Guide. See
Chapter 2, Installa tion
,of the TSU User Manual for
more information. An eight-position modular jack (labeled CPE) is
provided to connect to the customer equipment. The pinout is provided
on this Quick Start Guide. See
Chapter 2, Installati on
,of the TSU CSU
ACE User Manual for more information.
• The rear panel contains LBO dip switches for both the Network and CPE
interfaces. Detailed instructions on setting the switch positions are found
on the back of this sheet.
• The TSU CSU ACE can be powered by either of the following methods:
1. Use the included NEC Class 2, 12V at 400 mA wall mount power
supply.
2. Connect to a reliably grounded 12-48 Vdc source which is electrically
isolated from the AC source.
Note: The branch circuit overcurrent
protection shall be a fuse or circuit breaker rat ed 48V, minimum to
10A, maximum.
• Additional information can be found on the product CD which contains
the TSU User Manual, FAQs, Data Sheets, Applications, and White
Papers.
Quick Start Guide, 61202022L1-13A, September 2001 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2001 ADTRAN, All Rights Reserved
TSU CSU ACE P/N 1202022L1
ETWORK
N
Position 1 Position 2 Attenuation (dB)
CPE LBO S
Position 3 Position 4 Position 5 Cable Length (feet)
Off Off On 0-133
On On Off 134-265
Off On Off 266-399
On Off Off 400-533
Off Off Off 534-655
LBO S
On On 0
On Off 7.5
Off On 15
Off Off 22.5
WITCH POSITION SETTINGS
WITCH POSITION SETTINGS
EST AND MONITOR ACCESS
T
• Two monitor jacks are provided on the rear panel for bridging the
received signals to allow in service circuit monitoring.
• Four break-and-test jacks are provided on the rear panel for use in outof-service testing. Th ese jacks bypass the c onnections of the modular
jacks. N
output of the TSU CSU ACE. To test the CPE, a T1 Bit Error Rate Test
(BERT) test set can be used to simulate the network. E
can be used to simulate the CPE with a BERT test set, allowing the
network to be tested. The TSU CSU ACE on the other end of the circuit
can be looped back to test only the network.
ET IN
and N
ET OUT
are used to simulate the network inp ut and
and E
Q IN
Q OUT
Quick Start Guide, 61202022L1-13A, September 2001 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2001 ADTRAN, All Rights Reserved