JOBAID

TOTAL ACCESS

®

OPTI-T200

61184400L1-22A

 

 

 

 

0309

 

 

 

 

OPTI-T200

CLEI: SOI4JN6D_ _

OPTI-T200

1310 nm

1184400L1

TX

DS3

RX

STATUS

OPTICS

DS3

E

N

E

T

TX

RX

C

R

A

F

T

LED STATUS

STATUS

Off

No power to unit

Green

Power up and initialization OK

Yellow

Unit is in Out-of-Service – Unassigned mode

 

Flashing Yellow

Unit is in Out-of-Service – Maintenance mode

Red

Unit has an equipment failure

OPTICS

Green

Normal Operation

Yellow

Soft failure (e.g. RDI)

 

Flashing Yellow

Unit in Test (e.g. Loopback)

Red

LOS, LOL, or other hard alarms on optical

 

 

interface

Flashing Red

Unit in Test (e.g. Loopback) with an alarm present

 

 

on the Optical Interface

DS3 Off

DS3 disabled

Green

DS3 normal operation

Yellow

Soft failure (e.g. RDI)

Flashing Yellow

Unit in Test (e.g. Loopback)

Red

LOS, LOL, or other hard alarms on DS3 interface

Flashing Red

Unit in Test (e.g. Loopback) with an alarm present

 

 

on the DS3 Interface

CRAFT INTERFACE

Connect to terminal using a serial cable with a male DB-9 connector.

Set VT100 terminal emulation to 9600 bps, 8 Data Bits, No Parity, 1 Stop Bit, and No Flow Control.

Baud rate is configurable at 9600, 19,200, 38,400 or 115,200 bps.

DESCRIPTION

The OPTI-T200 is designed to work in a back-to-back mode of operation, OPTI-T200 to OPTI-T200. It uses a standard 1310 nm OC3 signal to interface between the systems and provides a single DS3 signal to the loop. The OPTI-T200 provides DCC communication with TL1 support. A craft port and an Ethernet port are available on the front panel for management. The OPTI-T200 is a T200 mechanics card, which will fit standard T200 and T400 enclosures.

Compliant with SONET standards, the OPTI-T200 functions as a terminal multiplexer, detecting standard optical, SONET, and DS3 related alarms and conditions. The OPTI-T200 is easily managed with TL1 or TCP/IP commands, or Telnet sessions separately to each system or via the craft interface.

INSTALLATION

1 The OPTI-T200 is a T200 mechanics card which will fit standard T200 and T400 enclosures. Ensure the appropriate chassis is installed before proceeding with the installation.

Carefully insert the OPTI-T200 halfway into the selected slot. Route the fiber cables to the front panel and approximately 4 inches past the SC receptacles (to create slack). Gently but firmly push the OPTI-T200 all the way into the slot, being careful not to pinch the fibers between the front panel and the shelf.

WARNING: Once fully inserted into the chassis, the module will be powered (provided power is connected to the chassis).

2 When the OPTI-T200 powers up, it performs a self-test. The front panel LEDs illuminate for approximately 8 seconds. The self-test is complete once the STATUS LED illuminates Green.

ALARM CONTACT DEFINITION

Lead

Assignment

Contact (functionally) *

Contact Rating

T (pin 7)

Failure detected on optical facility

Normally Open

60 VDC

R (pin 13)

 

 

0.2 A

T1 (pin 41)

Failure detected on coax facility

Normally Open

1M cycles (min)

R1 (pin 47)

 

 

− 40ºC to +65ºC (temp)

NOTE: Simultaneous T/R & T1/R1 contact closures used to indicate internal unit failure, loss of OC-3/DS-3 inputs, or loss of power.

POWER: –48VR = Pin 17, –48VDC = Pin 35, Frame-GND = Pin27.

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

For a complete Installation and Maintenance Practice (P/N 61184400L1-5): 877-457-5007, Faxback Document 918. Please have your fax number ready.

 

TOTAL ACCESS OPTI-T200

PRICING AND AVAILABILITY 800.827.0807 TECHNICAL SUPPORT 800.726.8663 RETURN FOR REPAIR 256.963.8722 www.adtran.com 61184400L1-22A

PROVISIONING OPTIONS

Upon initial installation, the OPTI-T200 uses factory default settings. To provision the OPTI-T200, connect a terminal emulator via the RS-232 (DB-9) connector on the front panel. The terminal must be VT100 compatible and set for 9600 bps, 8 data bits, no parity and 1 stop bit. The following table lists the provisioning settings and their default values. The settings are retained in a nonvolatile memory device in case of power loss to the OPTI-T200.

Options

Settings (Default in Bold)

Service State

In Service, Out Of Service-Unassigned, Out Of Service-Maintenance

DS3 Provisioning

 

 

DS3 Interface

Enable, Disable

DS3 Line Build Out

Short, Long

Signal Fail (SF) Thresh

1x10-3, 1x10-4, 1x10-5

Signal Degrade (SD) Thresh

1x10-5, 1x10-6, 1x10-7, 1x10-8, 1x10-9

Clock Source (TX)

1.

Receive OC-3

 

2.

Free Run

CLLI Code

User definable up to 20 characters

Network Provisioning

 

 

IP Address

User Defined

 

Format = x.x.x.x where x = 0–255

Subnet Mask

User Defined

 

Format = x.x.x.x where x = 0–255

Default Gateway

User Defined

 

Format = x.x.x.x where x = 0–255

Telnet Menu Port

User defined = 0–65535 (23)

Telnet (TL-1) Port

User defined = 0–65535 (2001)

Time and Date

User Defined

Mount Location

Central Office, Remote

Account Provisioning

See the Account Provisioning section to the right of this table.

Restore Factory Defaults

 

 

Software Upgrade

TFTP, XModem, YModem

NOTE: To navigate through the menus, select the desired entry and press Enter. To work backward in the menus, press the Escape key. Some entries can be changed in only the Out-of-Service – Maintenance mode.

ACCOUNT PROVISIONING

1.Account 1

a)User Name – User Defined, up to 15 characters

b)Password – User Defined, up to 15 characters

c)Permission Level – Disabled, Read Only, Read-Write, Administrator

d)Delete Account

2.Account 2 – Same options as Account 1

3.Account 3 – Same options as Account 1

4.Account 4 – Same options as Account 1

5.Account 5 – Same options as Account 1

6.Account 6 – Same options as Account 1

7.Account 7 – Same options as Account 1

8.Account 8 – Same options as Account 1

9.Account 9 – Same options as Account 1

10.Account 10 – Same options as Account 1

SOFTWARE UPGRADE

Software download for the local OPTI-T200 is provided using XModem or YModem via the craft port or TFTP, XModem or YModem via Ethernet. Software download to a remote OPTI-T200 is accomplished either from the CO OPTI-T200 craft port or its Ethernet port. The download is carried over the DCC channel. TFTP is supported from only the Ethernet interface, and both systems would require IP addresses.

COMPLIANCE

This product intended for use in Restricted Access Areas only, and is intended to be installed in a Type “B” or “E” enclosure. This product complies with UL 60950.

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

Installation Code (IC)

A

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate this equipment.

WARRANTY

ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. U.S. and Canada customer Faxback: 877-457-5007, Document 414.