Sonix r
make changes in content from time to time without obligation on
the part of
change.
of any kind, either implied or expressed, including, but not limited
to, the implied warranties of merchantability and fitness for a
particular purpose. 3Com
changes in the product(s) and/or the program(s) described in this
documentation at any time.
UNITED STATES GOVERNMENT LEGENDS:
If you are a United States government agency, then this
documentation and the software described herein are provided
to you subject to the fo llowing restri cted rights :
For units of the Department of Defense:
Legend:
subject to restrictions as set forth in subparagraph (c) (1) (ii) for
restricted Rights in Technical Data and Computer Software clause
at 48 C.F.R. 52.227-7013
Wilkinson Road, Cirencester, Gloucestershire, GL7 1YT.
eserves the right to revise this documentation and to
3Com Sonix t
3Com Sonix p
Use, duplication or disclosure by the Government is
All rights reserved. No part of this
Sonix.
o provide notification of such revision or
rovides this documentation without warranty
Sonix m
ay make improvements or
Restricted Rights
. 3Com Sonix Limited, Merchants’ House,
Restricted Rights Legend:
For civilian agencies:
or disclosure is subject to restrictions set forth in subparagraph (a)
through (d) of the Commercial Computer Software - Restricted
Rights Clause at 48 C.F.R. 52.227-19 and the limitations set forth in
3Com Corporation’s standard commercial agreement for the
software. Unpublished rights reserved under the copyright laws of
the United States.
If there is any software on removable media described in this
documentation, it is furnished under a license agreement included
with the product as a separate document, in the hard copy
documentation, or on the removable me dia in a direc tory file
named LICENSE.TXT. If you are unable to locate a copy, please
contact 3Com
Unless otherwise indicated, 3Com registered trademarks are
registered in the United States and may or may not be registered
in other countries.
3Com, Boundary Routing and Transcend are registered
trademarks of 3Com Corporation. Office
3Com Corporation.
SmartAgent
are service marks of
CompuServe is a registered trademark of CompuS erve, Inc.
Castelle is a registered trademark of Castelle Corporation.
and NetWare are registered trademarks of Novell Inc.
trademark of Microsoft Corporation. VT100 is a registered
trademark of Digital Equipment Corporation.
are trademarks of
Sonix a
nd a copy will be provided to you.
3Com Laser Library, 3TECH, CacheCard and
3Com Corporation
3Com Corporation. 3ComFacts
Connect i
.
Use, reproduction
s a trademark of
and
Novell
Windows is a
Other brand and product na mes may be registered tradema rks or
trademarks of their respective holders.
I
MPORTAN
T
S
AFETY INFORMATIO
N
WARNING:
must follow for your personal safety. Follow all
instructions carefully.
Please read carefully and thoroughly the following
information before installing the OfficeConnect Remote:
■
Exceptional care must be taken during installation
and removal of the unit.
Only stack the OfficeConnect Remote with other
■
Office
Only use the power adapter that is supplied with the
■
unit to ensure compliance with international safety
standards.
It is essential that the mains socket outlet is located
■
near the unit and is accessible. You can only remove
power to the OfficeConnect Remote by
disconnecting the power adapter from the unit or
from the socket outlet.
The safety status of the interconnection port on this
■
equipment are as follows:
Ports identified by the labels VOICE and ISDN = TNV
Warnings contain directions that you
Connect u
nits.
Ports identified by the labels SERIAL, COAX, 10BASET
and WAN = SELV
TNV (telecoms network voltage) is a circuit which
under normal operating conditions carries
telecommunication signals.
SELV (safety extra low voltage) is a secondary circuit
which is designed and protected so that under
normal and single-fault conditions, the voltage
between any two accessible parts does not exceed a
safe value (42.2 V peak or 60 V DC).
Only connect apparatus complying with the relevant
interface requirements to the ports on this unit..
There are no user-replaceable fuses or user-serviceable
■
parts inside the unit. If you have a physical problem
with the unit that cannot be solved with problem
solving actions in this guide, contact your supplier.
Disconnect the power adapter before moving the unit.
■
WARNING: Twisted Pair RJ45 data port.
shielded RJ45 data socket. It cannot be used as a
telephone socket. Only connect RJ45 data connectors
to this socket.
This is a
W
ICHTIGE
S
ICHERHEITSHINWEIS
E
ACHTUNG:
Die Warnungen enthalten Anweisungen,
die Sie zur eigenen Sicherheit zu befolgen haben.
Lesen Sie bitte die folgenden Informationen sorgfältig
durch, bevor Sie den OfficeConnect Rem ote einbauen:
besondere Vorsicht muß während des Ein- und Ausbaus
■
Auf
des OfficeConnect Remotes geachtet werden.
Stapeln Sie den OfficeConnect Remote nur mit anderen
■
OfficeConnect Einheiten zusammen.
Verwenden Sie nur das mit dem OfficeConnect Remote
■
mitgelieferte Netzteil um die internationalen
Sicherheitsstandards zu erfüllen.
Die Netzsteckdose muß sich in unmittelbarer Nähe des
■
OfficeConnect Remotes befinden und frei zugänglich sein.
Sie können den OfficeConnect Remote nur spannungsfrei
schalten, indem Sie das Steckernetzteil aus der
Netzsteckdose ziehen oder die Verbindung zum Gerät
unterbrechen.
Der Sicherheitsstandard der Anschlüsse fuer dieses Gerät
■
sind wie folgt:
Anschlüsse bezeichnet mit VOICE und ISDN = TNV
Anschlüsse bezeichnet mit SERIAL, COAX, 10BASET und
WAN = S E LV
TNV (Telecoms Network Voltage - Spannung des
Telekommunikationsnetzwerks) ist ein Anschluss, der unter
normalen Umständen Telekommunikationssignale enthält .
SELV (Safety Extra Low Voltage - Extra Sicherheitsspannung) ist
ein weiterer Anschluss, der unter normalen Umständen und
Fehlerkonditionen entworfen und gesichert wurde, so dass die
Spannung zwischen zwei erreichbaren Teilen kein gefährliches
Niveau erreicht (42.2V max. oder 60 V DC).
An den Anschlussbuchsen der Geräte dürfen nur die dafür
vorges
ehenen Anschlüsse verwendet werden.
Es sind keine von dem Benutzer zu ersetzende oder zu
■
wartende Teile in dem Gerät vorhanden. Wenn Sie ein
Problem mit dem OfficeConnect Remote haben, das nicht
mittels der Fehleranalyse in dieser Anleitung behoben
werden kann, setzen Sie sich mit Ihrem Lieferanten in
Verbindung.
Bevor der OfficeConnect Remote ausgebaut wird ist das
■
Netzteil zu ziehen.
ACHTUNG: gedrehte paarfache RJ45 Datenanschluss.
Es ist eine abgeschirmte RJ45 Datenanschlußbuchse. Sie
darf nicht als Telefonanschluß verwendet werden.
Verbinden Sie nur RJ45 Datenstecker mit diesem Anschluss.
L’
INFORMATION D
E
S
ÉCURITÉ IMPORTANTE
AVERTISSEMENT:
instructions que vous devez suivre pour votre sécurité
personnelle. Suivre toutes les instructions avec soin.
Veuillez lire à fond l’information suivante avant d’installer le
moyeu:
■
Le soin exceptionnel doit être pris pendant l’installation et
l’enlèvement du moyeu.
■
Seulement entasser le moyeu avec les autres moyeux
OfficeConnects.
■
Seulement utiliser la pièce de raccordement
d’alimentation qui est fournie avec le moyeu pour assurer
la conformité avec les norm es de sécurité internatio nales.
■
C’est essentiel que le socle de prise de courant du réseau
soit localisé proche du moyeu et soit accessible. Vous
pouvez seulement enlever l’alimentation au moyeu en
débranchant la pièce de raccordement d’alimentation de
l’unité ou du socle de prise de courant.
■
Les normes de sécurité des ports d'interconnexion sur cet
équipement sont les suivants:
Les ports marqués par les etiquettes VOICE et ISD N = TNV
Les ports marqués par les etiquettes SERIAL, COAX,
10BASET et WAN = SELV
Les avertissements contiennent les
TNV (Telecoms Network Voltage - tension réseau de
télécommunications) est un circuit qui dans des conditions
d'opérations normales, transfert les si gneaux télécoms.
SELV (Safety Extra Low Voltage - tension de sécurité
extra-réduite) est un circuit secondaire désigné et protègé qui
dans des conditions normales et de fautes uniques, assure que
la tension entre deux éléments accessibles n'accedéra pas un
niveau de sécurité (42.2V max. ou 60 V DC).
Connecter uniquement des unités conformes aux normes
relatives des interfaces de cet équipement.
■
Il n’y a pas de parties remplaceables par les utilisateurs ou
entretenues par les utilisateurs à l’intérieur du moyeu. Si
vous avez un problème physique avec le moyeu qui ne
peut pas être résolu avec les actions de la résolution des
problèmes dans ce guide, contacter votre fournisseur.
■
Débrancher la pièce de raccordem ent d’alimentation
avant de remuer le moyeu.
AVERTISSEMENT: Le port de données RJ45 de paire
tordue.
Ceux-ci est un socle de données RJ45 blindé. Il ne
peut pas être utilisé comme socle de téléphone. Seulement
brancher les connecteurs de données RJ45 à ce socle.
C
ONTENTS
I
MPORTAN
W
ICHTIGE SICHERHEITSHINWEIS
L’
INFORMATION D
A
BOU
Introduction 1
How to Use This Guide 1
Conventions 2
Additional Safety Information 3
G
1
ETTIN
Introduction 1-1
OfficeConnect Remote Features 1-1
Benefits of ISDN 1-3
Pack Contents Checklist 1-4
Registering Ownership Of Your OfficeConnect
Pre-installation Requirements 1-5
OfficeConnect Remote Front and Rear Panel
T SAFETY INFORMATIO
E SÉCURITÉ IMPORTANTE
T THIS GUID
G STARTE
Remote 1-5
Features 1-6
E
D
N
E
Installation 1-10
Siting
the OfficeConnect Remote 1-10
Using the Rubber Feet and Stacking Clips 1-11
Wall Mounting the OfficeConnect Remote 1-12
C
onnect
ing the Power Adapter 1-12
Connecting to Your 10BaseT LAN 1-13
Connecting to a Single Workstation 1-14
Connecting to Your 10Base2 LAN 1-14
Connecting to ISDN 1-15
Connecting to the W AN 1-16
Connecting to the VOICE Port 1-16
Connecting a Managemen t Term inal 1-16
Location of OfficeConnect Fax and Pr int
Servers 1-16
Quick Configuration 1-17
Starting Quick Configuration 1-17
About Quick Configuration 1-19
Setting the Unit Name 1-20
Connecting to a Novell (IPX) Network 1-21
Connecting to an IP Host on the Same IP
Network 1-22
Connecting to an IP Host on a Different IP
Network 1-23
Connecting to the Internet or a PPP Router 1-25
A
Monitoring ISDN Line Usage 1-28
Setting Up a WAN Link 1-28
Examples of Typical ISDN Networking Applications 1-30
Novell Network 1-30
IP Host on the Same IP Network 1-31
IP Host on Another IP Network 1-33
Internet or PPP Router 1-34
Multiple Connections from a Single Site 1-35
Troubleshooting 1-36
B
RIDGING AND ROUTIN
Introduction A-1
Bridging and Routing Concepts A-1
Guidelines For Choosing Bridging or Routing A-2
How Bridges Learn A-2
Bridging Between Remote Sites A-3
Building a Larger Network A-4
Multiple Paths Between Bridged LANs A-5
Network Topology A-6
Broadcast Storms A-6
Optimum Use of Resource A-6
Network Organization, Structure and Physical LayoutA-7
The Internet A-7
LAN Port Connecting Cable - 10BaseT B-9
Ordering Information B-10
L INFORMATIO
Support B-5
Support B-6
Support B-7
N
C
G
LOSSARY
D
T
ECHNICA
On-line Technical Services D-1
3Com Bulletin Board Service D-1
World Wide Web Site D-2
Support from Your Network Supplier D-2
Support from 3Com D-2
Returning Products for Repair D-3
I
NDE
X
L SUPPOR
T
A
BOU
T
T
HIS
G
UID
E
Introduction
This guide describes the features, installation and
initial configuration of the OfficeConnect Remote.
The guide has been designed to be used by both
first-time and experienced computer network users
who want to install and use the OfficeConnect
Remote. xxx
If you are working with an ISDN bridge or router for
the first time, it is possible you may make mistakes.
We have tried to identify the likely errors you may
make and have provided hints and tips to help you
recover from error situations.
Once you have carried out the intial configuration of
the unit using the
carry out additional configuration to optimize the
unit’s performance on your network. Refer to the
Software Refe rence
Quick Configuration
guide for more details.
option you can
How to Use This Guide
This table shows where to find specific information:
If you are looking for information on:
About the OfficeConnect Remote’s features, a
description of the front panel indicators and rear
panel connectors and step-by-step installation
and configuration instructions.
An overview of bridging and routing and an
introduction to IP and IPX protocols.
Technical Information and cable specifications
Glossary of technical terms
Technical Support information
Turn to:
Chapter 1
Appendix A
Appendix B
Appendix C
Appendix D
2
A
BOU
T THIS GUID
Conventions
The icon conventions that are used throughout this
guide are:
Icon
Type
Information Note
Caution
Warning
E
Description
Information notes call attention to
important features or instructions.
Cautions alert you to personal
safety risk, system damage, or loss
of data.
Warnings alert you to the risk of
severe personal injury.
The text conventions used in this guide are:
Convention
“Enter” vs. “Type”
Text represented as
screen display
Text represented as
commands
Keys
Italics
Description
When the word “enter” is used in this
guide, it means type something, then
press the [Return] or [Enter] key. Do not
press the [Return] or [Enter] key when an
instruction simply says “type.”
This typeface
displays on your screen, for example:
Enter the unit’s IP address:
This typeface
commands that you enter, for example:
CO IS NU
When specific keys are referred to in the
text, they are called out by their labels,
such as “the Return key” or “the Escape
key,” or they may be shown as [Return] or
[Esc].
If two or more keys are to be pressed
simultaneously, the keys are linked with a
plus sign (+), for example:
Press [Ctrl]+[Alt]+[Del].
are used to denote
Italics
emphasis
.
is used to represent
is used to represent
new terms
or
Additional Safety Information
Additional Safety Information
■
If any of the following conditions occur, isolate the
electricity supply and refer to your 3Com reseller.
3
See also the Important Safety Information at the front
of this guide.
When using the unit, observe the following safety
■
information:
Retain this user’s guide for later use and pass it on in
■
the event of change of ownership of the unit.
The power adapter supplied with the unit is fitted
■
with a moulded plug, for connection to a standard
electrical mains system supply socket. If this plug is
not suitable for your connection to your mains
supply, contact your reseller for advice. On no
account should you attempt to connect to your
mains supply using an inappropriate mains adapter.
Protect the unit from sudden, transient increases
■
and decreases in electrical power by fitting an in-line
surge suppresser or uninteruptable power supply.
Products manufactured by us are safe and without
■
risk provided they are installed, used and maintained
in good working order in accordance with our
instructions and recommendations.
If the case or cover is not correctly fitted.
■
If the case is damaged.
■
If the unit begins to make an odd noise, smell or
■
smoke.
If the unit shows signs of a distinct change in
■
performance.
Never install telephone wires during a lightening
■
storm, or install telephone connection sockets in
wet locations, unless the socket is specifically
designed for wet locations.
Do not touch uninstalled telephone wires or
■
terminals unless the telephone line has been
disconnected at the network interface. Always
exercise caution when installing or modifying
telephone lines.
Do not use a telephone, which is connected to the
■
unit, to report a gas leak in the vicinity of the leak.
Do not spill food or liquids on the unit. If the unit
■
gets wet, isolate the electrical supply and contact
your 3Com reseller.
4
A
BOU
T THIS GUID
E
■
Do not push any objects into the openings of the
unit. Doing so can cause fire or electric shock by
shorting out internal components.
■
Avoid using a telephone, which is connected to the
unit (other than a cordless type), during an electrical
storm. There may be a remote risk of electric shock
from lightning.
Equipment connected to the Voice port must be
■
located in the same building as the unit.
Be sure nothing rests on the unit’s system cables and
■
that the cables are not located where they can be
stepped on and cause damage to the unit.
Keep the unit away from radiators and heat sources.
■
Allow 25mm (1 inch) around the unit to provide
adequate air circulation.
Install the unit in a clean area that is free from dust
■
or extreme temperatures.
The unit has been designed to be a free standing
■
unit or stacked with other OfficeConnect units. Do
not place anything else on top of the unit’s case.
Allow a clearance gap of at least a 150 mm from the
■
rear panel of the unit, to allow for cable access.
■
This product ostensibly complies with the
electro-magnetic compatibility (EMC) requirements
of EN 55022 Class A and EN 50082 (susceptibility).
However, to fully comply with Class B of EN55022 the
following prerequisites should be observed;
the WAN port must be attached to a screened
■
digital cable.
the ISDN cable must be used in conjunction with
■
a three turn ferrite.
This unit contains a lithium battery which is
■
attached to a microchip on the printed circuit board.
The defective battery must be disposed of safely
in-line with the manufacturers instructions.
Interconnecting directly, or by way of other
■
apparatus, to ports complying with SELV
requirements may produce hazardous conditions on
the network. Advice should be sought from a
competent engineer before such a connection is
made.
1
Introduction
Welcome to the world of inter-networking with
3Com®. This chapter contains all the information you
need to install and configure the OfficeConnect
Remote to make it operational. You can carry out more
sophisticated configuration using the information in
the
Software Reference
In the modern business environment sharing
information is crucial. Until now only large businesses
could afford the high speed connections between
offices to gain the networking advantage. The
OfficeConnect Remote changes this and provides
high speed, low cost inter-networking for small
offices and home users.
The OfficeConnect Remote is ideal for linking together
remote offices or workgroups. It is compact and
attractively designed for desktop use and is part of
the OfficeConnect™ range which neatly stack together
with clips to provide a host of other facilities, for
example, Ethernet hub, print sharing and network fax.
G
ETTIN
guide.
G
S
TARTE
D
OfficeConnect Remote Features
The OfficeConnect Remote is designed to connect a
LAN (Local Area Network) at one location with a
number of other LANs at remote locations. The LAN
could comprise any number of PCs, servers or other
computing equipment, which in an office or small
business environment are typically linked together
using a centrally located Office
to interconnect the hubs in different locations, the
OfficeConnect Remote
over a WAN (Wide Area Network) ser vice provided by
telephone carrier organizations.
The most modern and efficient of these WAN
services includes ISDN (Integrated Services Digital
Network). This provides a high speed dialup facility
to allow your OfficeConnect Remote to
automatically and quickly dial remote offices,
transmit your data between remote PCs just as
speedily and then disconnect the call. You incur
minimum ISDN telephone
only when needed. This is known as Dial on Demand.
unit transmits information
Connect
charges
hub. In order
as calls are made
1-2
C
HAPTE
1:
G
R
ETTIN
G STARTE
D
ISDN can also be used to make voice calls
using the
OfficeConnect Remote from an ordinary telephone
handset, connect faxes and other similar office
equipment.
All OfficeConnect Remote models have
facilities for ISDN data transmission. Some models
have an additional port for voice calls and/or a port
to handle a third category of connection over a
serial WAN port.
The WAN port connects to a permanent leased line,
also available from your telephone carrier
organization. Leased lines are available to work at a
range of speeds which incur higher costs the higher
the line speed. The benefit of leased lines is their
permanence and fixed cost. No dialling is required
but unlike ISDN you pay a fixed cost regardless of
whether you transfer little data or high volumes of
data 24 hours a day.
Overall ISDN is probably the most cost effective
solution for small businesses. However, if your
requirements to move data between sites is likely to
increase you should consider purchasing the
OfficeConnect Remote model fitted with both ISDN
and WAN ports to ensure increased flexibility. The
range of OfficeConnect Remote units is as follows:
■
OfficeConnect Remote 510
– Provides connection
from 10BaseT or Thin Ethernet (10Base2) LANs to
ISDN services for data transfer between remote sites.
■
OfficeConnect Remote 520
– In addition to the data
transfer facilities, this model has a Voice port allowing a
telephone (or other equipment such as a Fax) to
communicate via ISDN.
■
OfficeConnect Remote 530
– This model has the
ISDN and Voice port facilities and additionally the
ability to connect via a WAN port to a serial leased
line.
All of the above models are available with U or S
ISDN interfaces.
Typically, the OfficeConnect Remote is used to
interconnect LANs running protocols such as
Transmission Control Protocol/Internet Protocol
( TCP/IP) or Novell Internetwork Packet Exchange (IPX).
Offering full LAN-to-LAN connectivity at speeds up to
64 Kilobits per second (Kbps) on each ISDN channel
and up to2 Megabits per second (Mbps) on the WAN
port (where fitted), the OfficeConnect Remote is a
compact desktop unit with unrivalled price and
performance.
Introduction
1-3
The principal features of the OfficeConnect Remote are:
■
Easy to install, configure and support
ISDN, 2B+D port, supporting Basic R ate interface of
■
two 64 Kbps
(or two 56 Kbps
and a 16 Kbps control channel
Optional voice port.
■
Optional Leased line wide area network (WAN)
■
access port
Data terminal equipment (DTE) management port
■
Support for full IP and IPX routing
■
Protocol transparent bridging
■
Sophisticated data packet filtering to provide
■
network security
Provides NetWare protocol
■
Data compression based on an optimized Lempel Ziv
■
algorithm
Remote and local management
■
Flash erasable programmable read-only memory
■
.
.
spoofing
.
channels
.
.
.
.
.
.
in the USA)
(EPROM), allowing the remote upgrading of the
units operating system.
Uses simple network management protocol (SNMP)
■
and provides management information base (MIB) II
support
.
Benefits of ISDN
ISDN is an extension of the national and international
public switched telephone network, which offers a
digital end-to-end telecommunication system,
providing a better quality service than available using
the analog telephone network. The principal
benefits of ISDN are:
Fast call setup times, typically taking less than one
■
second for national calls
Greater bandwidth with multiple channels.
■
.
The basic rate service, often referred to as ISDN 2,
carries two 64 Kbps user channels, called B channels
and one 16 Kbps control channel called the
D channel. The line service is presented into the
customers premises through a standard RJ45 socket.
A significant aspect of the ISDN service is th at it can be
provided over the same wiring that was installed for
the original telephone service. Therefore, ISDN can be
made available relatively cheaply almost anywhere
that previously had access to the analog system.
The cost of installation and rental of basic rate ISDN
lines has dropped to the point where it is extremely
attractive as regards cost and performance.
1-4
C
HAPTE
1:
G
R
ETTIN
G STARTE
D
Using ISDN to Support Leased Line WAN
Circuits
ISDN provides an ideal service to connect remote
LANs. To be effective, the connecting bandwidth
needed is at least 64 Kbps to achieve a realistic
throughput. Slower speed links can be used but
usually only when usage is low and infrequent, or if
higher speed circuits cannot be provided.
Leased digital point-to-point circuits
can
still
effective if usage spans many hours per day.
However as ISDN tariffs reduce, this balance also
changes. ISDN can be used to provide effective
backup of these point-to-point WAN circuits in two
ways.
Firstly, if the point-to-point circuit fails, an ISDN
■
channel can be dialled-up automatically and quickly,
to provide an alternative path to the remote unit.
Secondly, if the leased circuit becomes heavily loaded
■
due to peaks in the traffic between remote bridges or
routers, additional bandwidth can be automatically
dialled-up to supplement the bandwidth of the
leased circuit. The interconnected bridges would then
treat the leased line and ISDN channel as parallel links,
sharing the load across the two.
be
cost
Pack Contents Checklist
Before you install your OfficeConnect Remote, check
the contents of the box against the pack contents
checklist below. If any of the items have been
damaged in transit or are missing, then contact the
3Com dealer from whom the equipment was
purchased.
1 x OfficeConnect Remote unit.
■
1 x power adapter fitted with an appropriate plug for
■
your national power supply.
1 x 1.5 meter RJ45 to RJ45 male plug ISDN 2
■
connecting cable.
1 x 1.5 meter DB9 to DB9 serial manager port cable.
■
1 x British Telecom to RJ11 convertor (UK models of
■
OfficeConnect Remote 520 and 530 only).
1 x OfficeConnect Remote
■
1 x OfficeConnect Remote
■
1 x Warranty Registration Card.
■
It is important that you save the unit’s box and
protective packing material in case you need to
store, or transport it in the future.
User Guide
.
Software Refe rence
guide.
Introduction
1-5
Registering Ownership Of Your OfficeConnect
Remote
A
warranty
with your OfficeConnect Remote. Please take a few
moments before commencing the installation to fill
in the card and post it to us.
registration card is enclosed in the box
Pre-installation Requirements
Before you install your OfficeConnect Remote you
will need the following:
A suitable cable for connection to your LAN (or
■
workstation if only a single workstation is attached to
this unit).
Although the OfficeConnect Remote has two LAN
connections (10Base2 and 10BaseT), only one port
can be used at a time.
A standard ISDN line wall socket to connect the
■
ISDN cable to the ISDN port of the OfficeConnect
Remote. If a suitably sited wall socket is not already
available, then contact your telecommunications
supplier for assistance.
A suitable cable to connect to your ISDN socket.
■
A 1.5 meter ISDN cable is supplied with this unit.
The ISDN telephone number of the remote ISDN
■
unit in order to carry out the connection
configuration procedure.
A suitable WAN cable if you are connecting to the
■
remote site over a leased line.
1-6
C
HAPTE
1:
G
R
ETTIN
G STARTE
D
OfficeConnect Remote Front and Rear Panel Features
Fron t Pa ne l
Figure1-1
! ALERT
states.
■
■
■
OfficeConnect Remote Front Panel Features
(Orange) This LED indicator shows four
Off – Normal operation and no faults detected.
Slow flash – Loading software during power up or
new software is being downloaded to the unit.
Quick flash – S
elf test during power up
.
■
On – Problem detected. Refer to
“Troubleshooting”
on
page 1-38
information.
POWER
(Green) This LED indicator shows three states:
■
On – Power is connected to the unit.
■
Slow flash –
to the unit
New software is being downloaded
.
for more
Introduction
1-7
Quick flash – Self test or software loading during
■
power up.
Off – No power supplied to the unit. See
■
“Troubleshooting” on
page 1-38
for more details.
(Orange) This LED indicator shows the
LINK
condition of the LAN connection:
Off – No LAN connection detected.
■
On – LAN connected.
■
ISDN OK
(Green) This LED indicator provides
confirmation of the state of the ISDN line.
On – Indicates the OfficeConnect Remote is
■
connected to a working ISDN line. Sometimes
this LED does not light until the first call attempt
is made.
Flashing – A fault condition has been identified
■
on the ISDN line.
Off – No ISDN connection present.
■
ISDN1
and
ISDN 2
(
Yellow)
These LED indicators
provide confirmation that an ISDN call is in progress
on ISDN Channel 1 or Channel 2. You are connected
to a remote ISDN unit and are incurring ISDN call
charges while this LED is lit. If the LED is flashing it
indicates that a call is being made but a connection
has not yet been made to the remote unit.
1-8
C
VOICE
1:
HAPTE
G
R
ETTIN
G STARTE
D
(Yellow) If a Voice port is fitted this LED shows
the status of the voice connection:
On – A voice call is in progress.
■
Flashing – Indicates that handset is off the hook
■
and a dial tone is present or a call is being dialled
or ringing out. It also shows if the handset is
ringing (receiving an incoming call).
(Yellow) This LED indicator provides
WAN
confirmation of the state of the WAN link (if fitted). If
the LED is lit, the WAN connection is valid and can
pass data across the link. If the LED is flashing it
indicates a fault on the WAN port.
ISDN Utilization
(Green/Yellow) These LEDs show
the ISDN utilization as a percentage of network
loading. If you consistently see a continuous ISDN
loading of 100% and you require faster throughput,
then you might consider the following:
You could configure the unit to filter some of
■
the data. See
the
Software Reference
guide
for
more information.
An additional ISDN or WAN link is possibly
■
required to cope with the amount of data you
need to transfer.
Rear Panel
Introduction
1-9
Figure1-2
POWER
the OfficeConnect Remote to connect to the mains
power supply. Do not use any other adapter with this
unit.
match the mains inlet socket, contact your reseller
for further advice.
RESET
OfficeConnect Remote
Rear Panel Feature
s
Only use the power adapter supplied with
If the plug on the power adapter does not
For Technical Support use only.
SERIAL
The Serial Manager port enables a
management PC or terminal to be connected to the
OfficeConnect Remote using the 9-pin V.24 Serial
Manager cable supplied with the unit. The port
provides VT100 terminal emulation, running at 9600
bps. Refer to
AppendixB
for more information about
cables.
You also need a proprietary communications
software package such as Windows ‘Terminal’ to
communicate with the OfficeConnect Remote.
1-10
C
HAPTE
1:
G
R
ETTIN
G STARTE
D
(10Base2 Coaxial Port) – The coaxial LAN port
COAX
allows a 10Base2 Ethernet segment to be connected
directly to the OfficeConnect Remote. If the unit is to
be installed at the end of a cable run, then a 50 Ohm
terminator must be fitted to the 10Base2 cable
connector. This port can be used to connect to
OfficeConnect hubs.
MDI/MDIX Switch
Affects the operation of the
10BaseT LAN port. If you are connecting to a hub, leave
the switch in the In position. If you are connecting to a
single PC, set the switch to the
Out
position to
implement the 10BaseT crossover that is required.
(OfficeConnect Remote
WAN
520 and 530
only)
This port is used to provide connection to a WAN, via
a private leased line. The port terminates with a
25-way D-type female connector. This port supports
any of the CCITT data transmission standards;
X.21/V.11 V.24/V.28 (RS232), and V.35/V.36 at data
transfer rates up to 2 Mbps. Provided that connection
cables that follow these standards are used, the
OfficeConnect Remote automatically detects the
type of interface that the por t is required to support,
and configure it accordingly.
Refer to
AppendixB
for information about the WAN
interface cables required. Suitable cables are available
from your 3Com reseller as spare parts, refer to
AppendixB
10BASET
for required item part number
This RJ45 port is to the left of the ISDN socket
when looking at the rear of the unit and is used to
provide a connection to a 10Base T LAN. This sock et
allows direct connection between the Of ficeConnect
Remote and a single piece of equipment, as opposed to
multi-point LAN connections using 10Base2 cabling
systems. The OfficeConnect Remote LAN por t simulates
the characteristics of a workstation port, which allows it
to be directly connected to a LAN or networ k hub por t
as required.
If the LAN port is to be connected directly to a single
PC or workstation, then you must implement the
crossover by setting the MDI/MDIX switch to the out
position. See “MDI/MDIX Switch” for more
information.
This port is used to connect to the ISDN network.
ISDN
The port uses an RJ45 connection socket situated to the
left of the 10BaseT LAN sock et. A standard ISDN line
wall socket is required to connect the ISDN cable to the
ISDN port of the OfficeConnect Remote.
Introduction
1-11
(where fitted) This port is used to connect an
VOICE
optional public switched telephone network (PSTN)
telephone handset, or any other compatible analog
equipment, operating in digital tone multiple
frequency (DTMF) mode, by connecting the
handset’s plug into this port.
This port is in effect an analog to digital convertor
which allows you to use your conventional PSTN
telephone on an ISDN line. It is capable of supporting
ringing current and call progress tones, and
supports analog devices to a maximum ringer
equivalence number (REN) of two (United Kingdom).
Providing one of the two 64 Kbps ISDN channels is
not being used by the unit, then a voice call can be
made.
Incoming ISDN traffic carries both a voice and data
identifier and depending on the type of transmission,
a voice call is automatically directed to the
appropriate port connected to the telephone
handset.
The VOICE port is terminated with an RJ11 socket. If
your telephone equipment uses a different connector
jack, you will need to obtain a suitable convertor to
connect to the VOICE port.
A British Telecom to RJ11
convertor is supplied with UK models fitted with a
Voic e p or t .
1-12
C
HAPTE
1:
G
R
ETTIN
G STARTE
D
Installation
Siting
the OfficeConnect Remote
When siting the OfficeConnect Remote, ensure:
It is accessible and cables can be easily connected.
■
It is out of direct sunlight and away from sources of
■
heat.
Cabling is away from:
■
Sources of electrical noise, such as radios,
■
transmitters and broadband amplifiers.
Power lines and fluorescent lighting fixtures.
■
Water or moisture cannot enter the case of the unit.
■
Air flow around the unit and through the vents in
■
the side of the case is not restricted. We recommend
that you provide a minimum of 25mm (approx. 1
inch) clearance around the unit.
To prolong the operational life of your equipment:
Never stack
■
and ensure that they are clipped securely together.
Do not place objects on top of any unit or stack.
■
OfficeConnect
units more than four high
Using the Rubber Feet and Stacking Clips
The four self-adhesive rubber feet prevent your hub
from sliding around on your desk. Stick the feet to
the marked areas at each corner of the underside of
your hub.
The four stacking clips are used for neatly and
securely stacking your OfficeConnect units together.
You can stack up to a maximum of four units.
Large units must be stacked below small units.
Tostack your units, secure the clips on one side and
then on the other. Use the following method to
secure one side:
Place your new unit on a flat surface. Your clips fit in
1
the positions on the side of the unit, as shown in
Figu r e 1-3
Position a clip over one of these holes and push it in
2
until it clicks into place, as shown in
(1).
Figure1-3
Repeat this for the other clip position on the same
side.
Keeping the front of the units aligned, rest the
3
bottom of the new unit on the clips’ spikes, as shown
in
Figure1-3
(3). Push the clips firmly into the new
unit until they click into place.
(2).
Figure1-3
Clipping Your Units Together
Using the Rubber Feet and Stacking Clips
Wall Mounting the OfficeConnect Remote
There are two slots on the underside of the
OfficeConnect Remote which are used for wall
mounting. You can mount the unit with the LEDs
facing upwards or downwards, to suit your needs.
When wall mounting your OfficeConnect Remote,
ensure that it is within reach of the mains socket.
You need two suitable screws. Ensure that the wall
you are going to use is smooth, flat, dry and sturdy.
Make two screw holes which are 142 mm (5.6 in)
apart. Fix the screws into the wall, leaving their heads
3mm (0.12 in) clear of the wall surface.
Remove any connections to the units and locate it
over the screw heads. When in line, gently push the
OfficeConnect Remote on to the wall and move it
downwards to secure. When making connections,
be careful not to push the unit up and off the wall.
1-13
Repeat these steps to secure the other side.
To remove a clip, hold the units firmly with one hand
and hook the first finger of your other hand around
the back of the clip. Use reasonable force to pull it
off.
CAUTION:
Only wall mount single units, do not wall
mount stacked units.
1-14
C
onnect
1
2
C
HAPTE
1:
G
R
ETTIN
G STARTE
D
ing the Power Adapter
CAUTION:
Information”
Isolate the electrical mains system supply before
commencing installation.
Ensure
socket a
Connect the jack of the power adapter to the socket
on the rear panel of the OfficeConnect Remote (see
“Rear Panel”
P
lug the mains lead
adjacent electrical mains system socket
necessary turn on the power at the outlet socket.
First, read the section;
at the start of this manual.
any o
n/off power switches
re set to their ‘OFF’ positions.
on
page 1-8
).
of the power adapter i
“Important Safety
at the outlet
nto an
and if
Connecting to Your 10BaseT LAN
The OfficeConnect Remote performs a self test
3
loads the software
loading
the ALERT and POWER LEDs flash.
. During the self test
and
and software
Figure1-4
You can connect the OfficeConnect Remote to a
hub using 10BaseT cable in the following way:
Connect the UTP cable (not supplied) to the 10BaseT
1
port of the OfficeConnect Remote.
Connect the other end to a 10BaseT port on your hub.
2
Connect The UTP Cable To OfficeConnect hub
Figure1-5
Connect The
UTP
Cable To In-House Lan Connection Box
Using the Rubber Feet and Stacking Clips
Connecting to a Single Workstation
To connect the OfficeConnect Remote to a single
personal computer or workstation:
1
Implement the crossover for the 10BaseT port on
the
OfficeConnect Remote
switch to MDIX (out).
2
Connect the UTP cable (not supplied) directly into the
RJ45 socket marked LAN on the
Remote
3
Connect the other end to the 10BaseT socket on the
.
workstation’s Ethernet adapter.
by setting the MDI/MDIX
OfficeConnect
1-15
To connect the OfficeConnect Remote to i
n-house
LAN:
1
Connect the UTP cable (not supplied) into RJ45
socket marked LAN on the OfficeConnect Remote.
2
Connect the other end of the cable into the female
socket of the in-house LAN connection box, as shown
in
Figure1-5
, or directly to a 10BaseT hub port.
Loading...
+ 67 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.