Belkin F6HXXX-USB User Manual

0 (0)
Belkin F6HXXX-USB User Manual

Home Series UPS-USB

 

Model

 

F6H350-USB

 

F6H500-USB

 

F6H650-USB

 

 

 

 

 

 

 

 

 

Capacity

350

 

500

 

650

Input

Max Load

 

190 W

 

300 W

 

360 W

Voltage Range

 

 

 

105 ~ 135 Vac

 

 

 

 

 

 

 

Frequency

 

 

 

60Hz ±1Hz

 

 

Voltage (On battery)

 

 

Simulated Sine Wave, 120Vac ±10%

 

 

 

 

 

 

 

 

 

Frequency (On battery)

 

 

 

60Hz ±1Hz

 

Output

 

 

 

 

 

 

 

Voltage Regulation (AVR)

 

 

 

No AVR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transfer Time

 

 

 

N/A

 

 

 

 

 

 

 

 

 

Spike Protection

 

 

 

510 Joules

 

 

 

 

 

 

 

 

 

EMI/RFI Filter

 

 

 

Meets FCC Class B

 

 

 

 

 

Protection and

Overload Protection

 

UPS Low voltage switch to high voltage switch to battery: 105 ~ 135 ±3 Vac

Filtering

 

 

 

 

 

 

 

Unit Input

 

Breaker for overload and short circuit protection

 

 

 

Telecommunication

 

1 In, 2 Out Single Line (2 Wire, RJ11) jack s

 

Protection

 

 

 

 

 

 

 

 

 

Short Circuit

 

 

 

UPS shuts down

 

 

Voltage / Amps

 

12V / 5Ah

 

12V / 5Ah

 

12V / 7Ah

 

Type

 

 

Sealed, maintenance free lead acid

 

Battery

Typical Recharge Time

 

 

 

<8 Hours

 

 

 

 

 

 

 

 

 

Protection

 

Automatic self discharge protection, replace battery indicator LED

 

 

 

 

 

 

 

 

Battery Run Time

 

Upto 15 minutes

 

Upto 28 minutes

 

Upto 35 minutes

 

 

 

 

 

 

 

 

 

Battery Backup

 

 

 

 

 

 

 

 

 

Flashing Red LED and Audible Alarm 10 second continuous

 

Battery Low

 

Alarm

Overload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault

 

 

 

Solid Red LED Light

 

 

Battery Test

 

Slow beeping sound (about 15 second intervals)

 

 

 

 

 

 

 

Communication Port

 

 

 

USB Port

 

 

 

 

 

Environment

Ambient Operation

 

0 ~ 85% Relative Humidity (Non-condensing); 0 ~ 35º C Operation Temperature

 

 

 

 

 

 

 

Audible Noise

 

 

 

<40dBA at 1 meter

 

 

 

 

 

 

 

Weight (lbs)

8.81

 

10.14

 

12.34

Physical

 

 

 

 

 

 

 

Dimension W x D x H

 

 

 

9.84" x 6.61" x 3.15"

 

 

 

 

 

 

 

 

 

 

 

Compliance

 

UL/cUL, EMI, IEC 1000-4-2 Level 3, IEC 1000-4-4 Level 2, IEC 1000-4-5 Level 3,

 

 

FCC Part 68, CS-03, USB models are Microsoft XP Certified.

 

 

 

 

 

 

 

 

 

 

 

 

AC Power On

 

 

Press and hold longer than 2 sec.

 

 

 

 

 

 

 

Front Panel

Power Off

 

 

Press and hold longer than 2 sec.

 

Cold Start (Turns DC

 

 

Press and hold longer than 2 sec.

 

Switch

Power On)

 

 

 

 

 

 

 

 

 

 

Buzzer Silence (On Battery

 

 

 

Press less than 1.5 sec.

 

 

Mode)

 

 

 

 

 

 

 

 

 

 

 

Loading...