ZOOM 507 Operation Manual

Thank you for selecting the ZOOM 507 (hereafter simply called the "507"). Please take the time to read this manual carefully so you can get the most out of
your 507 and ensure optimum performance and reliability. Retain this manual for future reference.
ZOOM CORPORATION
NOAH Bldg., 2-10-2, Miyanishi-cho, Fuchu-shi, Tokyo 183, Japan PHONE: 0423-69-7116 FAX: 0423-69-7115
• High-grade reverb of top class devices despite compact size; delay with 990 ms maximum delay time; and outstanding spatial effects that produce a beautiful chorus sound at an affordable price.
• On-board "Zfx-2" DSP (Digital Signal Processor) developed by Zoom, and an innovative design used solely for its powerful spatial effects. Demonstrates its power in home recording as well as in live performances.
• You can switch between 24 patches to store diverse settings based on your preference.
• Integrated auto-chromatic tuner for guitar. You can tune your instrument easily anywhere, any time. You can also leave the tuning function disabled all the time.
• The optional FP01 expression pedal enables foot control of the mix level for the effect sound. The optional FS01 foot switch enables operation of the chorus ON/OFF switch.
• Dual power supply design allows the unit to be powered from an alkaline battery (6LR61) or an AC adapter.
USAGE AND SAFETY PRECAUTIONS
In this manual, symbols are used to highlight warnings and cautions for you to read so that accidents can be prevented. The meanings of these symbols are as follows:
Please observe the following safety tips and precautions to ensure hazard-free use of the 507.
• Since power consumption of this unit is fairly high, we recommend the use of an AC adapter whenever possible. When powering the unit from a battery, use only an alkaline type.
AC adapter operation
• Be sure to use only an AC adapter which supplies 9 V DC, 300 mA and is equipped with a "center minus" plug (Zoom AD-0006). The use of an adapter other than the specified type may damage the unit and pose a safety hazard.
• Connect the AC adapter only to an AC outlet that supplies the rated voltage required by the adapter.
• When disconnecting the AC adapter from the AC outlet, always grasp the adapter itself and do not pull the cable.
• If the unit is not to be used for a long time, disconnect the AC adapter from the outlet.
Battery operation
• Use only a 9 V (alkaline) battery (6LR61).
• The 507 cannot be used for recharging. Pay close attention to the labelling of the battery to make sure you choose the correct type.
• If the 507 is not to be used for an extended period of time, remove the battery from the unit.
• If battery leakage has occurred, wipe the battery compartment and the battery terminals carefully to remove all remnants of battery fluid.
• While using the unit, the battery compartment cover should be closed.
Avoid using your 507 in environments where it will be exposed to:
• Extreme temperature
• High humidity or moisture
• Excessive dust or sand
• Excessive vibration or shock
• The 507 is a precision instrument. Except for the foot switches, do not push other parts with your feet or subject them to strong force.
• Take care that no foreign objects (coins or pins etc.) or liquids enter the unit.
• Be sure to turn the power to all equipment off before making connections.
• Before moving the unit, turn the power off and disconnect all cables and the AC adapter.
Never open the case of the 507 or attempt to modify the product in any way since this can result in damage to the unit.
Usage precautions
For safety considerations, the 507 has been designed to provide maximum protection against the emission of electromagnetic radiation from inside the device, and from external interference.However, equipment that is very susceptible to interference or that emits powerful electromagnetic waves should not be placed near the 507, as the possibility of interference cannot be ruled out entirely.
Whatever the type of digital control device, the 507 included, electromagnetic damage can cause malfunctioning and corrupt or destroy data. Since this is an ever-present danger, thorough care should be taken to minimize the risk of damage.
Use a soft, dry cloth to clean the 507. If necessary, slightly moisten the cloth. Do not use abrasive cleanser, wax, or solvents (such as paint thinner or cleaning alcohol), since these may dull the finish or damage the surface.
Connecting cables and input and output jacks
You should always turn off the power to the 507 and all other equipment before connecting or disconnecting any cables. Also make sure to disconnect all cables and the AC adapter before moving the 507.
Major Features
Safety Precautions
!
Warning
This symbol indicates explanations about extremely dangerous issues. If users ignore this symbol and handle the device incorrectly, serious injury or death could result.
!
Caution
This symbol indicates explanations about dangerous issues. If users ignore this symbol and handle the device the wrong way, bodily injury and damage to the equipment could result.
!
Warning
About power
Caution
Environment
Caution
Handling
Caution
Alterations
Electrical interference
Cleaning
1
2
Operation Manual
The 24 patches can be easily selected by pressing the patch pedals. The right patch pedal switches to the next patch and the left patch pedal switches to the previous patch.
In the initial condition, the 507 is set up so that the patch pedals select patches continuously, but you can also set up the unit so that patches are switched only within a certain bank of four patches. [For details, see section 9 Patch Switching (Application: Bank Hold ON).]
Banks are selected with the VALUE +/­keys. Press the VALUE+ key to select the next bank, and the VALUE- key to select the previous bank.
For example, to switch from Patch 2, Bank A to Patch 3, Bank C, the patch pedal would have to be pressed nine times. Instead, you can press the VALUE+ key twice to switch to Bank C, and then press the patch pedal (UP) just once to select Patch 3.
The effects of the 507 can be turned off (bypassed) temporarily, so that only the original sound of the instrument is heard. In this mode, the auto-chromatic tuning function via the LED display is also active.
Bypass mode
Pressing both patch pedals simultaneously activates the Bypass mode.
To cancel the Bypass mode, simply press one of the patch pedals. The unit then reverts to the previously selected patch.
Tuner mode
The 507 is initially set so that the auto-chromatic tuning function for the guitar activates automatically when the Bypass mode is invoked. In Bypass mode, pick an open string to be tuned. The closest note will be shown on the display.
When the tuning function is active, the parameter cursor LEDs serve as tuning meter, designed to enhance tuning precision during fine adjustments.
Turning tuning function off
If you do not want to activate the tuning function in Bypass mode, press the STORE and EDIT keys simultaneously for more than one second in Play mode. The tuning function will be turned off, and this setting will be stored even when the power is turned off. When you turn the function off, the display will show "tunEr oFF" (tuning function off).
To turn the tuning function on, press the same keys simultaneously again. The display will show "tunEr on" (tuning function on).
NOTE: Please note that the tuning function may not operate properly if other effect modules between the
guitar and the 507 are on.
Selecting Patches
Using the Bypass/Tuner Mode
PATCH
DOWN
PATCH
UP
Patch switching
24 patches are available
Bank switching
Banks A, b, C, d, E, F are available
BANK UP
BANK DOWN
BANK F
PATCH 1 PATCH 2 PATCH 3 PATCH 4
BANK E
PATCH 1 PATCH 2 PATCH 3 PATCH 4
BANK d
PATCH 1 PATCH 2 PATCH 3 PATCH 4
BANK C
PATCH 1 PATCH 2 PATCH 3 PATCH 4
BANK b
PATCH 1 PATCH 2 PATCH 3 PATCH 4
BANK A
PATCH 1 PATCH 2 PATCH 3 PATCH 4
Pitch is too high Correctly tuned Pitch is too low
7
8
Do = C
Do# = C#
Re = D
Regular tuning
6th string 1st string
4th string
Mi = E
Fa = F
Fa# = F#
Regular tuning
Regular tuning
3rd string
Regular tuning
5th string
Regular tuning
2nd string
Re# = D#
So = G
So# = G#
La = A
La# = A#
Si = B
Input signal
standby condition
&
w
&
#w
&
w
&
#w
&w
&
w
&
#w
&
w
&
#w
&
w
&
#w
&
w
Bank/patch switching
when Bank Hold is off
(initial setting)
Bypass ON/OFF
The bypass function is invoked by pressing the left and right patch pedals simultaneously. To cancel the Bypass/Tuner mode, just press one of the patch pedals.
Calibration
Select reference pitch for auto-chromatic guitar tuner (calibration).
Press both pedals together
* The reference pitch (A) can be adjusted in the range from 435 to 445 Hz. When the BANK key is pressed in Bypass/Tuner mode, this is shown as "35" to "45" on the display for a second. Adjust to the suitable value. At power-on, the setting is 440 Hz (40).
Tuner ON/OFF
Pressing the EDIT key and the STORE key simultaneously for more than one second in Play mode will allow you to select whether or not to activate the tuning function in Bypass mode. When you change the setting, the display will show"tunEr oFF" (tuning function off) or "tunEr on" (tuning function on) according to the setting.
Currently selected
patch is displayed
Press Release immediately Tuning function (only when the tuning function is ON)
Loading...
+ 4 hidden pages