York CZF, CZH, TCHD, YCJF, YHJD User Manual

...
USER’S INFORMATION MANUAL
®
OUTDOOR SPLIT-SYSTEM AIR CONDITIONING OR HEAT PUMP
MODELS: SINGLE PHASE & THREE PHASE
TABLE OF CONTENTS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
HOW YOUR SYSTEM WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
COOLING CYCLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
HEATING CYCLE (HEAT PUMPS) . . . . . . . . . . . . . . . . . . . . . . . . . 1
System Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SETTING THE THERMOSTAT . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
THERMOSTATS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
YOUR KEY TO COMFORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
COOLING ONLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
COOLING AND HEATING (HEAT PUMP) . . . . . . . . . . . . . . . . . . .2
MANUAL CHANGE-OVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PROGRAMMABLE ELECTRONIC THERMOSTATS . . . . . . . . . . . . . 2
FAN OPERATION SELECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
AUTO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
POWER FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
MANUAL CHANGE-OVER THERMOSTAT . . . . . . . . . . . . . . . . . .2
ELECTRONIC THERMOSTAT . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
TO MAXIMIZE OPERATING EFFICIENCY . . . . . . . . . . . . . . . . . . . . .3
HEATING CONSERVATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
COOLING CONSERVATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
CARE OF SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
COIL CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
SERVICE CALLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
FILTER CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
PARTS INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
EXTENDED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
SOME EFFICIENCY DO’S & DON’TS . . . . . . . . . . . . . . . . . . . . . . .3
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
CONT ACT INFORMATION
• Go to website at www.york.com, then click on “Contact Us” and follow the instructions.
• Contact us by mail:
The manufacturer recommends that the user read this manual and keep the manual for future reference.
SAFETY
This product must be installed and serviced by a qualified installer or service agency. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
HOW YOUR SYSTEM WORKS
COOLING CYCLE
If your hand is wet and you blow on it, it feels cool because some of the moisture is evaporating and becoming a vapor. This process requires heat. The heat is being taken from your hand, so your hand feels cool.
That’s what happens with an air conditioner. During the cooling cycle, your system will remove heat and humidity from your home and will transfer this heat to the outdoor air.
HEATING CYCLE (HEAT PUMPS)
During the heating cycle, your system will remove heat and humidity from the outdoor air and will transfer this heat to your home. This is pos­sible because even 0°F outdoor air contains a great deal of heat. Remember that your heat pump doesn’t generate much heat, it merely transfers it from one place to another.
System Operation
Your thermostat puts full control of the comfort level in your home at your fingertips. DO NOT switch your thermostat rapidly ON and OFF or between HEAT to COOL. This could damage your equipment. Always allow at least 5 minutes between changes.
Johnson Controls Unitary Products
Consumer Relations
5005 York Drive
Norman, OK 73069
SETTING THE THERMOSTAT
The main power to the system must be kept ON at all times to prevent damage to the outdoor unit compressor. If necessary, the thermostat control switch should be used to turn the system OFF. Should the main power be disconnected or interrupted for 8 hours or longer, DO NOT attempt to start the system for 8 hours after the power has been restored to the outdoor unit. If heat is needed during this 8 hour period, use emergency heat.
THERMOSTATS
YOUR KEY TO COMFORT
Although thermostats may vary widely in appearance, they are all designed to perform the same basic function: to control the operation of your air conditioning or heat pump system. Regardless of size or shape, each thermostat will feature a temperature indicator; a dial, arm, or push button for selection of the desired temperature; a fan switch to choose the indoor fan operation; and a comfort switch for you to select the system mode of operation.
Only approved thermostats have been tested and are fully compatible with this equipment. Please be aware that many different thermostats
operate on batteries or “power stealing” principals. These types of ther­mostats can not be supported as trouble free when used with this product.
If your system has been designed to allow both cooling and heating operation, you may have either a manual change-over type, or a pro­grammable electronic type thermostat.
Manual change-over simply means that the comfort switch must be manually positioned every time you wish to switch from the cooling to heating or heating to cooling modes of operation.
Johnson Controls Unitary Products 813196-UUM-E-0314
813196-UUM-E-0314
NOTICE
A complete operating instruction is provided by the manufacturer for each thermostat. Familiarize yourself with its proper operation to obtain the maximum comfort with minimum energy consumption.
The computerized electronic thermostat is actually a sophisticated elec­tronic version of a manual change-over type. This thermostat includes features which allow “set-back” temperature variations for periods of sleep, or while you are away during the day, and means energy savings for you. The thermostat also features a digital clock.
COOLING ONLY
If your air conditioning system is designed to provide cooling only (AC), with no capability for heating operation (heat pump), a two-stage cool­ing only thermostat, with a manual, one-position “Cool” and “Off” com­fort switch is all that is required for system operation.
COOLING AND HEATING (HEAT PUMP)
If your system has been designed to allow both cooling and heating operation, you may have either a manual change-over type, or a pro­grammable electronic type thermostat with 2-stages of cooling and 2­stages of heat.
MANUAL CHANGE-OVER
Manual change-over simply means that the comfort switch must be manually positioned every time you wish to switch from the cooling to heating or heating to cooling modes of operation.
PROGRAMMABLE ELECTRONIC THERMOSTATS
The computerized electronic thermostat is actually a sophisticated elec­tronic version of a manual change-over type. This thermostat includes features which allow “set-back” temperature variations for periods of sleep, or while you are away during the day, and means energy savings for you. The thermostat also features a digital clock.
FAN OPERATION SELECTION
A multi-position fan switch allows you to choose the type of fan opera­tion of the indoor fan.
AUTO
With the thermostat fan switch set to “AUTO”, the fan will run intermit­tently as required for either heating or cooling. This position will provide the lowest operating cost. If you purchased one of our thermostats, they have an Intelligent fan mode which continually circulates the air during occupied modes or when you are at home, and can cycle the fan during unoccupied mode or during the night while you sleep to further con­serve energy.
ON
CONTINUOUS FAN OPERATION: With the thermostat fan switch set to “ON”, the indoor fan will not shut off. However, the cooling (AC) or heat­ing (heat pump) systems will still operate as required by room tempera­tures. This provides continuous air filtering and more even temperature distribution to all conditioned spaces.
FAN ONLY OPERATION: On moderate days, usually during spring and fall, when neither heating nor cooling is required, you may want to run only the fan to ventilate, circulate and filter the air in your home or build­ing. Set the comfort control switch to “OFF” and the fan switch to “ON”. Be sure to return the switches to their original positions for normal oper­ation.
START-UP
The maximum and minimum conditions for operation must be observed to assure a system that will give maximum performance with minimum service.
TABLE 1:
CoolDBHeatDBCoolDBHeat
The comfort control switch is assumed to be in the “OFF” position. If the main power supply to the outdoor and indoor units is off, turn the appro­priate disconnects to the “ON” position. Place the system into operation as follows.
1. Set temperature adjustment to the desired temperature on your
COOLING - The higher the setting, the lower the amount of energy con­sumed. Federal Guidelines recommend a setting of 78 °F.
HEATING - The lower the setting, the lower the amount of energy con­sumed. Federal guidelines recommend a setting of 65 °F or lower.
If your cooling and heating temperature adjustments are separate, be sure to set both.
2. After considering “Fan Operation Selection” above, select and set
3. Move the comfort control switch to the desired mode of operation
Application Limitations
Air Temperature at
Outdoor Coil, °F
Min. Max. Min. Max.
DB
60 -10 115 75 57
1.
Operation below this temperature is permissible for a short period of time, during morning warm-up.
thermostat.
the fan operation mode you desire.
(Cooling or Heating) found on your particular thermostat.
Air Temperature at
Indoor Coil, °F
WB
Cool
DB
Heat
50
1
WB
Cool
72 80
DB
Heat
POWER FAILURE
When accidents, wind storms, etc. disrupt electrical power supply to your house, switch thermostat to “OFF” position.
SYSTEM OPERATION
MANUAL CHANGE-OVER THERMOSTAT
COOLING YOUR HOME: With the comfort control switch in the “COOL” position, the system will operate as follows: When the indoor temperature rises above the level indicated by the temperature adjust­ment setting, the system will start. The outdoor unit will operate and the indoor fan will circulate the cooled, filtered air. When the room tempera­ture is lowered to the setting selected, the system will shut off.
HEATING YOUR HOME: If your system includes a heating unit and the comfort control switch is in the “HEAT” position, the system will operate as follows: When the indoor temperature drops below the level indi­cated by the temperature adjustment setting, the system will start. The heating system will operate and the indoor fan will circulate the filtered air. When the room temperature rises to the setting selected, the sys­tem will shut off. Whether heating or cooling, the fan will continue to operate if the fan switch was set in the “ON or Intelligent” position. The “AUTO” setting on the fan switch will allow the fan to shut off when your system does.
ELECTRONIC THERMOSTAT
The computerized electronic thermostat, when programmed, will func­tion automatically to operate the system as follows: When the indoor temperature rises above the higher (COOL) setting, the outdoor unit will operate and the indoor fan will circulate the cooled, filtered air. When the room temperature is lowered to the selected level, the system will shut off. The indoor fan will either shut off or run continuously, depend­ing upon your choice of fan switch setting. When the indoor tempera­ture drops below the lower (HEAT) setting, the heating system will operate, and the indoor fan will circulate the heated, filtered air. When