Yokogawa Yokogawa CA320 Manual

User's Manual
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
This manual explains how to use the TC Calibrator. Keep this manual in a safe place for quick reference in the event that a question arises.
2nd Edition: January 2016 (YMI) All Rights Reserved, Copyright © 2015, Yokogawa Meters & Instruments Corporation Printed in Japan
Safety Precautions
The handling precautions, component names, and specifications are covered in the separate Getting Started Guide (IM CA310-02EN). Be sure to read the Getting Started Guide before using this instrument.
Basic Setup
Auto power-off
If this is set to ON when the instrument is running on batteries, the power automatically turns off if you do not operate the instrument for approx. 20 minutes. This is invalid when the instrument is running off of the AC adapter.
Backlight
Turns the backlight on and off. If set to Timer, the backlight turns on for approx. 2 minutes every time you operate a key.
Sweep time
When sweeping in steps, set the output duration of each step. When sweeping linearly, set the output duration for the value to change from 0% to 100% (or 100% to 0%).
Measure and Source Terminal
Set whether to use the thermocouple mini plug terminal (A) or the banana terminal (B).
RJ Sensor
Sets whether to turn the reference junction compensation on or off when measuring temperature or sourcing temperature using the banana terminal.
Burnout
Set whether to detect thermocouple burnouts.
Temperature Reference
Set the temperature reference to ITS-90 or IPTS-68.
Extended Sensor
Set the sensor to be assigned to the EXTRA range.
Initialization of Span Settings
Initializes the span settings.
Initialization of Settings
Initializes settings.
Using the RJ Sensor
This instrument has a built-in RJ sensor for reference junction compensation. In addition, you can also use an external RJ sensor (sold separately) to perform junction compensation based on an external contact.
Thermocouple Mini Plug Terminal
The internal reference junction compensation is always enabled. External reference junction compensation using an external RJ sensor is not possible.
Banana Terminal
If an external RJ sensor is not connected, the internal reference junction compensation is enabled. If it is connected, external reference junction compensation is enabled. To perform reference junction compensation with the banana terminal, set the RJ sensor in the basic setup (mentioned above) to ON.
Note
CA320 TC Calibrator User’s Manual
IM CA320-01Z2
2nd Edition
Turn the instrument on, and set the rotary switch to Use the left-most up and down keys to select the setting and the right-most up and down keys to switch the options. Press OUTPUT ON/OFF to confirm the setting.
Selects the setting
Selects an option
Display
SETTING
Setting
Auto power-off
POWER
▲▲▲▲▲▲▲
TYPE
Backlight
Sweep time Measure and source terminal
Confirms the settings
RJ sensor (banana terminal) Burnout detection Temperature reference Extended sensor Initialization of span settings Initialization of settings
*: Default value
• You cannot turn off the RJ sensor when the thermocouple mini plug terminal is in use.
• If you are not using external reference junction compensation, be sure to remove the external RJ sensor.
.
Options
*
/OFF
ON ON/OFF 15s A
ON
ON ITS-90
D
*
/TIMER
*
/30s/45s/60s
*
/B
*
/OFF
*
/OFF
*
/IPTS68
*
/G/PL2
Measurement
1.
Set the CA320’s measure/source switch to
2.
Follow the instructions in the Getting Started Guide to connect the CA320 to the device to be measured using the included lead cable.
3.
Use the rotary switch to set the range.
4.
Press
TYPE
to select
TYPE1 or TYPE2.
MEASURE
.
Note
• When the range is set to EXTRA, the sensor selected for EXTRA in the basic setup is selected. When the range is set to 90 mV, voltage ranging from -11.000 mV to 99.999 mV can be measured.
• The included binding post can also be attached to the banana terminal.
Sourcing
1.
Set the CA320’s measure/source switch to ON appears on the screen, and the output is turned on.
2.
Use the rotary switch to set the range.
3.
Press
to select TYPE1 or TYPE2.
TYPE
SOURCE
.
Note
When the range is set to EXTRA, the sensor selected for EXTRA in the basic setup is selected. When the range is set to 90 mV, voltage ranging from -11.000 mV to 99.999 mV can be sourced. It can be used to calibrate a thermocouple whose thermoelectromotive force falls within this range.
4.
Follow the instructions in the Getting Started Guide to connect the CA320 to the target device using the included lead cable.
5.
Follow the instructions for common operations in the Getting Started Guide, and set the output
value with the ▼ and ▲ keys. The number of counts that change when the ▼ or ▲ key is
pressed varies depending on the range.
Note
• The CA320 is calibrated excluding the voltage dip in the lead cable. Load current readings include an error resulting from the lead cable resistance.
• The included binding post can also be attached to the banana terminal.
Changing the Output Mode
1.
Refer to “Keys” in the Getting Started Guide, and set the output mode.
Normal output (no display): The set value is output. The output value can be varied using the ▼ and ▲ keys.
Span check ( ): In addition to normal output, the output can be varied in units of 25% of the span. Step sweep( ): The output is varied automatically in steps of 25% of the span. Linear sweep ( ): The output is varied linearly from 0% to 100%.
Output setting for span check
▲▲▲▲▲▲▲
Set to 100% of span
Set to 0% of span
Press simultaneously to set the output mode.
Pressing this when sweeping is paused sets the output to the span 0% value.
▲▲▲▲▲▲▲
Increase or decrease by 1 count
Increase or decrease by 100 counts
Increase or decrease in 25% steps of span
Sweeping
The output value is varied automatically between 0% and 100% of the specified span. There are two sweep modes: step and linear.
Step sweep Linear sweep
Sweep time
100%
Output
0%
1.
Set the 0% and 100% of the span, which is the sweep range.
Set the span 0% value using the ▼ and ▲ keys and then press simultaneously the first and the second ▼ keys from the right. SET is displayed, and 0% is set. Likewise, set the span 100% value using the ▼ and ▲ keys and then press simultaneously the first and the second ▼ keys from the right.
For details on key operation, see “Keys” in the Getting Started Guide.
2.
Set the output mode to step sweep or linear sweep. The ON indicator blinks.
3.
Press Pressing value continues to be output while sweeping is paused. Pressing
When sweeping is paused, pressing the left-most ▲ key sets the output to the span 0% value.
. Sweeping will start. The ON indicator changes to solid.
TYPE
TYPE
TYPE
Time
again pauses sweeping and causes the ON indicator to blink. The displayed
yet again resumes sweeping from the last output value.
100%
0%
Sweep time
Output
Time
Changing the Sub Display
The temperature shown on the main display can be displayed using a value converted into thermoelectromotive force or a percentage of the span. The temperature measurement of the RJ sensor is also displayed. This is invalid when the range is 90 mV.
▲▲▲▲▲▲▲
Press simultaneously to set the sub display.
Thermoelectromotive force
Percentage of span
Temperature measurement of RJ sensor
IM CA320-01Z2
User's Manual
本書では、熱電対キャリブレータの操作方法について説明しています。 お読みになったあとは大切に保存してください。ご使用中に操作がわからなくなったときなどにきっ とお役に立ちます。
2nd Edition:January 2016 (YMI) All Rights Reserved, Copyright © 2015, Yokogawa Meters & Instruments Corporation Printed in Japan
本機器を安全にご使用いただくために
本機器を使用するときの注意、各部の名称、仕様については、別冊のスタートガイド (IM CA310-02JA) に記載しています。 本機器を使用する前に、必ずスタートガイドをお読みいただき、正しくご使用ください。
基本設定をする
1.
2.
3.
オートパワーオフ
乾電池で駆動している場合、ON に設定すると、約 20 分間操作しないと自動的に電源
が OFF になります。AC アダプタで駆動しているときは無効です。
バックライト
バックライトを ON/OFF します。Timer に設定すると、キー操作するたびに約 2 分間バッ
クライトが点灯します。
スイープ時間
ステップスイープの場合は各ステップ値の出力時間、リニアスイープの場合は 0%から
100% (100% から 0% ) までの出力時間を設定します。
温度測定 / 発生端子
熱電対ミニプラグ端子 (A) を使用するか、バナナ端子 (B) を使用するかを設定します。
RJ センサー
バナナ端子を使用して温度測定または温度発生する場合に基準接点補償するか (ON)、
しないか (OFF) を設定します。
バーンアウト
熱電対の断線 ( バーンアウト ) を検出するか (ON)、しないか (OFF) を設定します。
温度基準
温度の基準を ITS-90 または IPTS-68 のどちらかに設定します。
拡張センサー
EXTRA レンジに割り当てるセンサーを設定します。
スパン設定の初期化
スパン設定を初期化します。
設定の初期化
設定を初期化します。
RJ センサーを使用する
本機器には基準接点補償用 RJ センサーが内蔵されています。また、外付け RJ センサー ( 別 売 ) を使用して外部の接点を基準とした接点補償を行うこともできます。
熱電対ミニプラグ端子
内部の基準接点補償が常に有効になります。外付けの RJ センサーを使った外部接点に
よる基準接点補償はできません。
バナナ端子
外付けの RJ センサーが接続されていないときは内部の基準接点補償が有効、外付けの
RJ センサーが接続されているときは、外部接点による基準接点補償が有効になります。 バナナ端子に基準接点補償する場合は、上記の基本設定の RJ センサーを ON にします。
Note
CA320 熱電対キャリブレータ ユーザーズマニュアル
IM CA320-01Z2 2版
本機器の電源を ON にして、ロータリースイッチを SETTING に合わせます。 左端の上下キーで設定項目を選択し、右端の上下キーで選択肢を切り替えます。
OUTPUT ON/OFF キーで設定を確定します。
設定項目の選択
選択肢の選択
表示
設定項目
オートパワーオフ
POWER
▲▲▲▲▲▲▲
TYPE
バ ックラ イト スイープ時間 温度測定/発生端子 RJセンサー(バナナ端子)
設定の確定
バーンアウト検出 温度基準 拡張センサー スパン設定の初期化 設定の初期化
*:初 期 値
・ 熱電対ミニプラグ端子を使用しているときは、RJ センサーを OFF にできません。 ・
外部接点による基準接点補償
い。
をしない場合は、必ず
外付けの
選択肢
*
/OFF
ON ON/OFF 15s A ON ON ITS-90 D
*
/TIMER
*
/30s/45s/60s
*
/B
*
/OFF
*
/OFF
*
/IPTS68
*
/G/PL2 - -
RJ センサーを外してくださ
測定する
1.
本機器の測定 / 発生切り替えスイッチを MEASURE( 測定 ) に設定します。
2.
スタートガイドに従って、本機器と測定対象を付属の測定発生用リードケーブルで接 続します。
本機器に内蔵されている RJ センサーを使って基準接点補償する場合は、本機器と測 定対象を熱電対で接続してください。
3.
ロータリースイッチでレンジを設定します。
4.
TYPE を押して、TYPE1 または TYPE2 どちらかを選択します。
Note
・ EXTRA に設定すると、基本設定の EXTRA で設定したセンサーが選択されます。
90mV に設定すると、-11.000mV ~ 99.999mV の電圧を測定できます。
・ 付属のバインディングポストをバナナ端子に装着することもできます。
発生する
1.
本機器の測定 / 発生切り替えスイッチを SOURCE( 発生 ) に設定します。
画面に ON が表示され、出力が ON になります。
2.
ロータリースイッチでレンジを設定します。
3.
TYPE を押して、TYPE1 または TYPE2 どちらかを選択します。
Note
EXTRA に設定すると、基本設定の EXTRA で設定したセンサーが選択されます。 90mV に設定すると、-11.000mV ~ 99.999mV の電圧を発生できます。熱起電力がこの範囲の熱 電対を校正する場合などに使用できます。
4.
スタートガイドに従って、本機器と対象機器を付属の測定発生用リードケーブルで接 続します。
本機器に内蔵されている RJ センサーを使って基準接点補償する場合は、本機器と対 象機器を熱電対で接続してください。
5.
スタートガイドの共通操作に従って、▼▲キーで出力値を設定します。▼▲キーで増 減するカウント数はレンジによって異なります。
Note
・ 本機器はリードケーブルの電圧降下分を除いて校正されています。
負荷電流をとる場合は、リードケーブルの抵抗が誤差になります。
・ 付属のバインディングポストをバナナ端子に装着することもできます。
出力モードの変更
1.
スタートガイドの「操作キー」に従って、出力モードを設定します。
通常出力 ( 表示なし ):設定値を出力。出力値を▼▲キーで変更可能
スパンチェック ( ):通常出力に加え、スパンの 25%単位で出力を変更可能
ステップスイープ ( ):スパンの 25%単位で自動的にステップ出力
リニアスイープ ( ):0%~ 100%をリニアに変化させて出力
スパンチェックの出力値設定
▲▲▲▲▲▲▲
スパンの100%
に設定
スパンの0%
に設定
同時に押して出力モードを設定
スイープ一時停止中に押すと、スパ ンの0%に設定
スイープ
設定したスパンの 0%と 100%の間で、自動的に出力値が変化します。スイープには、
ステップスイープとリニアスイープがあります。
ステップスイープ リニアスイープ
スイープ時間
100%
出力
0%
1.
スイープの範囲であるスパンの 0%と 100%を設定します。
スパンの 0%の値を▼▲キーで設定し、右から 1 番目と 2 番目の▼キーを同時に押し
時間
100%
0%
ます。SET が表示され、0%が設定されます。
同様に 100%の値を▼▲キーで設定し、右から 1 番目と 2 番目の▲キーを同時に押し ます。
キー操作の詳細はスタートガイドの「操作キー」をご覧ください。
2.
出力モードをステップスイープまたはリニアスイープに設定します。ON の表示が点 滅します。
3.
TYPE を押します。スイープが開始されます。ON の表示が点灯に変わります。
再度、TYPE を押すと、スイープが一時停止し、ON の表示が点滅します。停止中も 表示されている値が出力されます。
さらに、TYPE を押すと、停止した出力値からスイープを再開します。
スイープが一時停止中に、左端の▲キーを押すと、スパンの 0%に出力値が設定され ます。
▲▲▲▲▲▲▲
1カウント増 減
100カウント増 減
スパンの25%ステップで増減
スイープ時間
出力
時間
サブ表示を変更する
メイン表示に表示されている温度を、熱起電力、スパンに対する割合 (% ) に変換した
値で表示できます。また、RJ センサーの測定温度も表示します。レンジが 90mV のと きは無効です。
▲▲▲▲▲▲▲
同時に押してサブ表示を設定 熱起電力   スパンの%   RJセンサーの測定温度
IM CA320-01Z2
Loading...