Yokogawa MLD Specifications

Yokogawa Corporation of America
2 Dart Road, Newnan, GA 30265
770-254-0400
GS 61A01A-01E-A
March 2018
4th Edition
Model MLD
Loop Powered Process Indicator
Model
Suffix Codes
Description
MLD Field Mounted Loop Indicator (Digital)
Input Signal
-A 4 to 20 mA DC
Mounting
1 2
2” Horizontal Pipe 2” Vertical Pipe (or wall mount)
Housing
/1
/2
Cast Aluminum Alloy - (Standard Housing)
SUS316 Cast Stainless Steel and ASTM CF-8M
Electrical Connection
/00
/20
/30
/40
ANSI ½ NPT female, without blind plug
ANSI ½ NPT female, 316 Stainless Steel blind plug
ISO M20 female, without blind plug
ISO M20 female, 316 Stainless Steel blind plug
Ex Protection
/FF1 /CF1
FM Explosion Proof CSA Explosion Proof
Optional Specifications
Coating
/X1
/X2
Epoxy resin coating
Polyurethane-Epoxy Anti-corrosion coating
Paint
/P1
/P2
/P3
/P4
/P5
/P6
/P7
Light Blue (RA L # 5012)
Orange (RAL # 2008)
Red (Munsell # 7.5 R4/14)
Mint Green
Silver (RAL # 9006)
Yellow (RAL # 1018)
Gray (RAL # 7046)
Calibration
/ENG
Engineering Unit Calibration (MLD Only)
Stainless Steel Tag
/SST
Stainless Steel tag screw attached to housing
Stainless Steel Tag
/SSW
Stainless Steel tag wired to housing
The Model MLD field mounted
indicator receives DC voltage or current signals from electronic Transmitters and indicates process measurement values. Standard models are NEMA4X and Explosion Proof.
STANDARD SPECIFICATIONS
Voltage Drop:
1.8V typ., 2V max.
Scale: 0-1999 w/decimal
Accuracy:
± 0.05% of full scale (1999) ±1 count
Operating Temperature Range:
-20 to 60°C
Temperature drift: ±0.3 Count/°C
Insulation
terminals and case 100 Mohm at 500 V DC
Dielectric
and case: 1000 VAC for 1 minute.
Mounting:
surface.
Explosion Protection Type:
EXPLOSIONPROOF A,B,C,D, GROUPS E,F,G
Case and Cover: Die cast aluminum or 316 Stainless Steel, baked polyurethane paint. Moss Green (Stainless Steel is unpainted); NEMA 4X
Electrical
M20 x 1.5
Weight: 2.7 lbs
ORDERING INSTRUCTIONS
1. Model and suffix codes.
2. Option codes
Example
Resistance: Between input
Strength: Between input terminals
Nominal 2” (50mm) pipe mount or
DUST-IGNITIONPROOF
CL1, DIV1, GROUPS
Connection: ½ x 14 NPT or
Ordering
FM, CSA,
CLII / III,
Instructions:
MLD-A1/1/00/FF1/ENG/SST Field Mounted Loop Indicator (Digital), 4 to 20 mA DC, 2” Horizontal Pipe, FM Explosion Proof
0-200 InH2O Scale in Engineering Units. Please specify Engineering units when ordering /ENG FT-201 Specify Tag Number when ordering /SST or /SSW.
GS 61A01A-01E-A Mar ch 2 018
DIMENSIONS