Yokogawa CL120 Data sheet

Clamp-on Testers
CL Series and 30031 of Clamp-on Testers
Our CL Series offers wide range of current measurement
AC Current Measurement CL120/130/135/150/155
AC/DC Current Measurement CL220/235/250/255
Leakage Current Measurement CL320/340/345/360
CL120
CL235
CL340
CL150
CL130
CL360
Bulletin CL-E
Selection Guide
For AC Current
Model Diameter of measurable conductor Display DC current
AC current
Other measurement
Other functions
Page
For AC/DC Currents
Model Diameter of measurable conductor Display DC current
AC current
Other measurement
Other functions
Page
Range Resolution Range Resolution Frequency characteristics Method of detection AC voltage DC voltage Continuity check Frequency Temperature Recorder output Waveform monitor output Data hold Auto hold Peak hold maximum value memory Mean value display Filter Range hold (current range) Auto ZERO adjust Auto power-off
Range Resolution Range Resolution Frequency characteristics Method of detection AC voltage DC voltage Continuity check Frequency Temperature Recorder output Waveform monitor output Data hold Auto hold Peak hold maximum value memory Mean value display Filter Range hold (current range) Auto ZERO adjust Auto power-off
CL120 CL130 CL135
24mm
1999
-
-
20/200A
0.01A
40~1kHz 40~1kHz
Mean value True RMSMean value Mean value True RMS
-
-
-
-
-
-
-
-
-
-
-
-
-
1
CL220
24mm
3999
40/300A
0.01A
40/300A
0.01A
20~1kHz
Mean value
-
-
-
-
-
-
-
-
-
-
-
-
-
30mm 30mm 54mm
-
-
200/600A
0.1A
-
-
-
-
-
-
-
-
-
-
-
-
1999 39991999
-
-
200/600A
0.1A
40~1kHz 40~1kHz
-
-
-
-
-
-
-
-
-
-
-
-
2213
CL235
33mm
3999
400/1000A
0.1A
400/600A
0.1A
40~1kHz
True RMS
-
-
-
-
-
-
-
CL150 CL155 Notes
-
-
400/2000A
0.1A
-
-
-
-
-
-
-
(
current range
-
CL250
55mm
3999
400/2000A
0.1A
400/2000A
0.1A
40~1kHz
Mean value
-
-
-
-
-
-
-
(current range)
)
54mm
3999
400/2000A
0.1A
40~1kHz
(
current range
CL255
55mm
3999
400/2000A
0.1A
400/2000A
0.1A
30~1kHz
True RMS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
△△
△ △ △ △
4455
)
:Sleep function (power-down)
Notes
:Sleep function (power-down)
For Leakage Current
Model Diameter of measurable conductor Display DC current
AC current
Other measurement
Other functions
Page
Range Resolution Range Resolution Frequency characteristics Method of detection AC voltage DC voltage Continuity check Frequency Temperature Recorder output Waveform monitor output Data hold Auto hold Peak hold maximum value memory Mean value display Filter Range hold (current range) Auto ZERO adjust Auto power-off
CL320 CL340 CL360
24mm 1999
-
-
20/200mA,200A
0.01mA
40~400Hz 20~1kHz
Mean value Mean valueMean value
-
-
-
-
-
-
-
-
-
-
-
-
40mm 68mm
-
-
40/400mA,400A
0.01mA
-
-
-
-
-
-
-
-
-
-
-
6
CL345
40mm
4200
-
-
40/400mA,400A
0.01mA
20~1kHz
True RMS
-
-
-
-
-
-
-
-
-
-
-
7
200mA/2/20/200/1000A
19993999
-
-
0.1mA
40~1kHz
-
-
-
-
-
-
-
-
-
-
76
30031
40mm
3200
-
-
3/30mA 30/60A
0.001mA 50/60Hz
Mean value
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8
Notes
Clamp-on Testers
CL120 CL130
AC A
24
AC/20~200A
●
Light weight & compact design
●
Mean value display
●
Data hold function
●
Approved for comformity to safety standards EN61010-1,
EN61010-2-032
Specifications
Parameter AC current
(CAT. III 300 V)
Accuracy:±( % rdg + dgt) = ±(% readout + value of least significant digit)
Reference
20A
200A
At 23℃±5℃,75%RH or less
Accuracy
2.0+7 (50〜1kHz)
2.0+5 (50/60Hz)
3.0+10 (40〜1kHz)
General Specifications
Parameter Method of detection Display Response time Range switching Data hold Ambient temperature and humidity Temperature coefficient Influence of external magnetic field Influence of conductor position Safety standard Circuit voltage Withstanding voltage Power supply Battery life Consumed current Auto power-off Diameter of measurable conductor Dimensions Weight Accessories
0-40℃, 85% RH or less (no condensation)
Conforms EN 61010-1, EN61010-2-032
Approx. 59(W)×148(H)×26(D)mm
Specification
Mean value
LCD(Digital display:1999 counts)
Approx. 2 seconds
Manual-range
On all range
-
0.8A or less at 400A/m
±2% or less
300Vrms or less
3.7kV AC for one minute
LR-44 ×2(3V) or SR-44 ×2
Approx. 100 hours (continuous)
Approx. 1mA Approx. 10 minutes 24mm at maximum
Approx. 100g
User's manual(IM CL120), batteries,
carrying case(93033)
●
Mean value display
●
Data hold function
●
Approved for comformity to safety standards EN61010-1,
EN61010-2-031, EN61010-2-032
Specifications
Parameter AC current
AC voltage
Resistance
General Specifications
Parameter Method of detection Display Response time
Range switching Data hold Ambient temperature and humidity
Temperature coefficient Influence of external magnetic field Influence of conductor position Safety standard Circuit voltage Withstanding voltage Power supply Battery life Consumed current Auto power-off Diameter of measurable conductor Dimensions Weight Accessories
AC A
30
AC/200~600A
AC V/ 
(CAT. III 600 V)
Accuracy:±( % rdg + dgt) = ±(% readout + value of least significant digit)
Reference
200A
600A
200V/600V
200Ω
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032
1.2+4 , Beeps at below 30Ω(continuitycheck)
LCD(Digital display:1999 counts)
(approx. 2 seconds on resistance renge)
-10-50℃, (no condensation)
5.55kV AC for one minute
6F22(006P)9V ×1 or 6LR61 ×2
Approx. 200 hours (continuous)
Approx. 93(W)×210(H)×40(D)mm
User's manual(IM CL130), batteries,
At 23℃±5℃,75%RH or less
Accuracy
1.5+6 (50/60Hz)
2.0+5 (40〜1kHz)
1.0+3 (50/60Hz)
2.0+5 (40〜1kHz)
1.0+2 (50/60Hz)
1.5+4 (40〜1kHz)
Specification
Mean value
Approx. 1 second
Manual-range
On all range
up to 30℃, 90%RH up to 40℃, 75%RH up to 50℃, 45%RH
-
2A or less at 400A/m
±2% or less
600Vrms or less
Approx. 2mA Approx. 10 minutes 30mm at maximum
Approx. 400g
carrying case(93032)
1
Clamp-on Testers
CL135 CL150
AC A
30
AC/200~600A
RMS
AC V/ 
●
True RMS Display
●
Data hold function
●
Approved for comformity to safety standard EN61010-1,
EN61010-2-031, EN61010-2-032
Specifications
Parameter AC current
AC voltage
Crest factor Resistance
Accuracy:±( % rdg + dgt) = ±(% readout + value of least significant digit)
Reference
200A
600A
200V/600V
40A
200Ω
(CAT. III 600 V)
At 23℃±5℃,75%RH or less
1.5+4 (50/60Hz)
2.0+5 (40〜1kHz)
1.5+4 (50/60Hz)
2.0+5 (40〜1kHz)
1.0+2 (50/60Hz)
1.5+4 (40〜1kHz)
1.2+4 , Beeps at below 30Ω(continuitycheck)
3 (50/60Hz)
General Specifications
Parameter Method of detection Display Response time
Range switching Data hold Ambient temperature and humidity
Temperature coefficient Influence of external magnetic field Influence of conductor position Safety standard Circuit voltage Withstanding voltage Power supply Battery life Consumed current Auto power-off Diameter of measurable conductor Dimensions Weight Accessories
(approx. 2 seconds on resistance renge)
Conforms EN61010-1, EN61010-2-031, EN61010-2-032
Specification
True RMS
LCD(Digital display:1999 counts)
Approx. 1 second
Manual-range
On all range
-10-50℃, (no condensation) up to 30℃, 90%RH up to 40℃, 75%RH up to 50℃, 45%RH
-
2A or less at 400A/m
±3% or less
600Vrms or less
5.55kV AC for one minute
6F22(006P)9V ×1 or 6LR61 ×2
Approx. 200 hours (continuous)
Approx. 2mA Approx. 10 minutes 30mm at maximum
Approx. 93(W)×210(H)×40(D)mm
Approx. 400g
User's manual(IM CL130),
batteries, carrying case(93032) 
Accuracy
●
Mean value display
●
DC output function
●
Data hold function
●
Sleep function
●
Approved for comformity to safety standards EN61010-1,
EN61010-2-031, EN61010-2-032
Specifications
Parameter AC current
AC voltage
DC voltage Resistance DC output
General Specifications
Parameter Method of detection Display Response time Range switching
Data hold Peak hold Ambient temperature and humidity Temperature coefficient Influence of external magnetic field Influence of conductor position Safety standard Circuit voltage Withstanding voltage Power supply Battery life Consumed current Sleep function
Diameter of measurable conductor Dimensions Weight Accessories
AC A
AC/400~2000A
AC V/DC V/
(CAT. III 600 V, CAT. II 1000 V)
Accuracy:±( % rdg + dgt) = ±(% readout + value of least significant digit)
Reference
400A
2000A(0〜1500A)
2000A(1500〜2000A)
40/400/750V
40/400/1000V
400/4k/40k/400kΩ
400A(0〜400mV)
2000A(0〜150mV/01500A)
2000A(150〜200mV/15002000A)
1.5+2 , Beeps at below 50±35Ω(continuitycheck)
LCD(Digital display:3999 counts)
Manual-range(on AC current range)/
Auto-range(on AC voltage range, resistance range)
0-40℃, 85% RH or less (no condensation)
±(2.0% rdg + 3dgt) or less
Conforms EN61010-1, EN61010-2-031, EN61010-2-032
5.55kV AC for one minute
R6P(SUM-3) ×2 or LR6 ×2
Approx. 150 hours (continuous)
Automatically powered down in about 10 minutes
after the last switch operation
Approx. 105(W)×247(H)×49(D)mm
User's manual(IM CL150), batteries,
At 23℃±5℃,75%RH or less
Accuracy
1.0+3 (50/60Hz)
2.0+3 (40〜1kHz)
1.0+3 (50/60Hz)
3.0+3 (40〜1kHz)
3.0(50/60Hz)
1.0+2 (50/60Hz)
1.5+3 (40〜1kHz)
1.0+2
±1.5% rdg ±0.5mV (50/60Hz)
±2.5% rdg ±0.5mV (40〜1kHz)
±1.5% rdg ±0.5mV (50/60Hz)
±3.5% rdg ±0.5mV (40〜1kHz)
±3.5% rdg (50/60Hz)
Specification
Mean value
Approx. 2 seconds
On all range
On AC current range
-
1A or less at 400A/m
1000Vrms or less
Approx. 5mA
54mm at maximum
Approx. 470g
carrying case(93034)
54
2
Loading...
+ 8 hidden pages