Clamp-on Testers
CL Series and 30031 of Clamp-on Testers
Our CL Series offers wide range of current measurement
●AC Current Measurement CL120/130/135/150/155
●AC/DC Current Measurement CL220/235/250/255
●Leakage Current Measurement CL320/340/345/360
CL120
|
CL340 |
CL235 |
CL130 |
30031
CL150 |
CL360 |
Bulletin CL-E
Selection Guide
■ For AC Current
Model |
|
CL120 |
CL130 |
CL135 |
CL150 |
CL155 |
Notes |
Diameter of measurable conductor |
24mm |
30mm |
30mm |
54mm |
54mm |
|
|
Display |
|
1999 |
1999 |
1999 |
3999 |
3999 |
|
DC current |
Range |
- |
- |
- |
- |
- |
|
|
Resolution |
- |
- |
- |
- |
- |
|
AC current |
Range |
20/200A |
200/600A |
200/600A |
400/2000A |
400/2000A |
|
|
Resolution |
0.01A |
0.1A |
0.1A |
0.1A |
0.1A |
|
|
Frequency characteristics |
40~1kHz |
40~1kHz |
40~1kHz |
40~1kHz |
40~1kHz |
|
|
Method of detection |
Mean value |
Mean value |
True RMS |
Mean value |
True RMS |
|
Other measurement |
AC voltage |
- |
● |
● |
● |
● |
|
|
DC voltage |
- |
- |
- |
● |
● |
|
|
Continuity check |
- |
● |
● |
● |
● |
|
|
Frequency |
- |
- |
- |
- |
- |
|
|
Temperature |
- |
- |
- |
- |
- |
|
Other functions |
Recorder output |
- |
- |
- |
● |
● |
|
|
Waveform monitor output |
- |
- |
- |
- |
- |
|
|
Data hold |
● |
● |
● |
● |
● |
|
|
Auto hold |
- |
- |
- |
- |
- |
|
|
Peak hold |
- |
- |
- |
● |
● |
|
|
maximum value memory |
- |
- |
- |
- |
- |
|
|
Mean value display |
- |
- |
- |
- |
- |
|
|
Filter |
- |
- |
- |
- |
- |
|
|
Range hold (current range) |
● |
● |
● |
●(current range) |
●(current range) |
|
|
Auto ZERO adjust |
- |
- |
- |
- |
- |
|
|
Auto power-off |
● |
- |
- |
|
|
:Sleep function (power-down) |
Page |
|
1 |
1 |
2 |
2 |
3 |
|
■ For AC/DC Currents
Model |
|
CL220 |
CL235 |
CL250 |
CL255 |
Notes |
Diameter of measurable conductor |
24mm |
33mm |
55mm |
55mm |
|
|
Display |
|
3999 |
3999 |
3999 |
3999 |
|
DC current |
Range |
40/300A |
400/1000A |
400/2000A |
400/2000A |
|
|
Resolution |
0.01A |
0.1A |
0.1A |
0.1A |
|
AC current |
Range |
40/300A |
400/600A |
400/2000A |
400/2000A |
|
|
Resolution |
0.01A |
0.1A |
0.1A |
0.1A |
|
|
Frequency characteristics |
20~1kHz |
40~1kHz |
40~1kHz |
30~1kHz |
|
|
Method of detection |
Mean value |
True RMS |
Mean value |
True RMS |
|
Other measurement |
AC voltage |
- |
● |
● |
● |
|
|
DC voltage |
- |
● |
● |
● |
|
|
Continuity check |
- |
● |
● |
● |
|
|
Frequency |
- |
● |
- |
● |
|
|
Temperature |
- |
- |
- |
- |
|
Other functions |
Recorder output |
- |
- |
● |
● |
|
|
Waveform monitor output |
- |
- |
- |
- |
|
|
Data hold |
● |
● |
● |
● |
|
|
Auto hold |
- |
- |
- |
- |
|
|
Peak hold |
- |
● |
- |
● |
|
|
maximum value memory |
- |
- |
● |
- |
|
|
Mean value display |
- |
● |
- |
● |
|
|
Filter |
- |
- |
- |
- |
|
|
Range hold (current range) |
- |
- |
●(current range) |
- |
|
|
Auto ZERO adjust |
● |
● |
● |
● |
|
|
Auto power-off |
|
|
|
|
:Sleep function (power-down) |
Page |
|
4 |
4 |
5 |
5 |
|
■ For Leakage Current
Model |
|
CL320 |
CL340 |
CL345 |
CL360 |
30031 |
Notes |
Diameter of measurable conductor |
24mm |
40mm |
40mm |
68mm |
40mm |
|
|
Display |
|
1999 |
3999 |
4200 |
1999 |
3200 |
|
DC current |
Range |
- |
- |
- |
- |
- |
|
|
Resolution |
- |
- |
- |
- |
- |
|
AC current |
Range |
20/200mA,200A |
40/400mA,400A |
40/400mA,400A |
200mA/2/20/200/1000A |
3/30mA 30/60A |
|
|
Resolution |
0.01mA |
0.01mA |
0.01mA |
0.1mA |
0.001mA |
|
|
Frequency characteristics |
40~400Hz |
20~1kHz |
20~1kHz |
40~1kHz |
50/60Hz |
|
|
Method of detection |
Mean value |
Mean value |
True RMS |
Mean value |
Mean value |
|
Other measurement |
AC voltage |
- |
- |
- |
- |
- |
|
|
DC voltage |
- |
- |
- |
- |
- |
|
|
Continuity check |
- |
- |
- |
- |
- |
|
|
Frequency |
- |
- |
- |
- |
- |
|
|
Temperature |
- |
- |
- |
- |
- |
|
Other functions |
Recorder output |
- |
- |
- |
● |
- |
|
|
Waveform monitor output |
- |
- |
- |
● |
- |
|
|
Data hold |
● |
● |
● |
● |
● |
|
|
Auto hold |
- |
- |
- |
- |
- |
|
|
Peak hold |
- |
● |
● |
● |
- |
|
|
maximum value memory |
- |
- |
- |
- |
- |
|
|
Mean value display |
- |
- |
- |
- |
- |
|
|
Filter |
● |
● |
● |
● |
- |
|
|
Range hold (current range) |
● |
● |
● |
● |
- |
|
|
Auto ZERO adjust |
- |
- |
- |
- |
- |
|
|
Auto power-off |
● |
● |
● |
- |
● |
|
Page |
|
6 |
6 |
7 |
7 |
8 |
|
Clamp-on Testers
CL120 |
AC A |
|
|
|
24 |
|
AC/20~200A |
●Light weight & compact design
●Mean value display
●Data hold function
●Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)
CL130 |
AC A |
|
|
|
30 |
|
AC/200~600A |
|
AC V/ |
● Mean value display |
|
● Data hold function |
|
● Approved for comformity to safety standards EN61010-1, |
|
EN61010-2-031, EN61010-2-032 (CAT. III 600 V) |
|
■Specifications
At 23 ±5 75%RH or less Accuracy:±( % rdg + dgt) = ±(% readout + value of least significant digit)
Parameter |
Reference |
Accuracy |
AC current |
20A |
2.0+7 (50 1kHz) |
|
200A |
2.0+5 (50/60Hz) |
|
3.0+10 (40 1kHz) |
|
|
|
■General Specifications
Parameter |
Specification |
Method of detection |
Mean value |
Display |
LCD(Digital display:1999 counts) |
Response time |
Approx. 2 seconds |
Range switching |
Manual-range |
Data hold |
On all range |
Ambient temperature and humidity |
0-40 , 85% RH or less (no condensation) |
Temperature coefficient |
- |
Influence of external magnetic field |
0.8A or less at 400A/m |
Influence of conductor position |
±2% or less |
Safety standard |
Conforms EN 61010-1, EN61010-2-032 |
Circuit voltage |
300Vrms or less |
Withstanding voltage |
3.7kV AC for one minute |
Power supply |
LR-44 ×2(3V) or SR-44 ×2 |
Battery life |
Approx. 100 hours (continuous) |
Consumed current |
Approx. 1mA |
Auto power-off |
Approx. 10 minutes |
Diameter of measurable conductor |
24mm at maximum |
Dimensions |
Approx. 59(W)×148(H)×26(D)mm |
Weight |
Approx. 100g |
Accessories |
User's manual(IM CL120), batteries, |
|
carrying case(93033) |
|
|
■Specifications
At 23 ±5 75%RH or less Accuracy:±( % rdg + dgt) = ±(% readout + value of least significant digit)
Parameter |
Reference |
Accuracy |
AC current |
200A |
1.5+6 (50/60Hz) |
|
2.0+5 (40 1kHz) |
|
|
|
|
|
600A |
1.0+3 (50/60Hz) |
|
2.0+5 (40 1kHz) |
|
|
|
|
AC voltage |
200V/600V |
1.0+2 (50/60Hz) |
|
1.5+4 (40 1kHz) |
|
|
|
|
Resistance |
200Ω |
1.2+4 , Beeps at below 30Ω(continuity check) |
■General Specifications
Parameter |
Specification |
Method of detection |
Mean value |
Display |
LCD(Digital display:1999 counts) |
Response time |
Approx. 1 second |
|
(approx. 2 seconds on resistance renge) |
Range switching |
Manual-range |
Data hold |
On all range |
Ambient temperature and humidity |
-10-50 , (no condensation) |
|
up to 30 , 90%RH |
|
up to 40 , 75%RH |
|
up to 50 , 45%RH |
Temperature coefficient |
- |
Influence of external magnetic field |
2A or less at 400A/m |
Influence of conductor position |
±2% or less |
Safety standard |
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 |
Circuit voltage |
600Vrms or less |
Withstanding voltage |
5.55kV AC for one minute |
Power supply |
6F22(006P)9V ×1 or 6LR61 ×2 |
Battery life |
Approx. 200 hours (continuous) |
Consumed current |
Approx. 2mA |
Auto power-off |
Approx. 10 minutes |
Diameter of measurable conductor |
30mm at maximum |
Dimensions |
Approx. 93(W)×210(H)×40(D)mm |
Weight |
Approx. 400g |
Accessories |
User's manual(IM CL130), batteries, |
|
carrying case(93032) |
1
Clamp-on Testers
CL135 |
AC A |
|
|
|
30 |
|
AC/200~600A |
|
RMS |
|
AC V/ |
● True RMS Display |
|
● Data hold function |
|
● Approved for comformity to safety standard EN61010-1, |
|
EN61010-2-031, EN61010-2-032 (CAT. III 600 V) |
|
■Specifications
At 23 ±5 75%RH or less Accuracy:±( % rdg + dgt) = ±(% readout + value of least significant digit)
Parameter |
Reference |
Accuracy |
|
AC current |
200A |
1.5+4 (50/60Hz) |
|
|
2.0+5 (40 1kHz) |
|
|
|
|
||
|
600A |
1.5+4 (50/60Hz) |
|
|
2.0+5 (40 1kHz) |
|
|
|
|
||
AC voltage |
200V/600V |
1.0+2 (50/60Hz) |
|
|
1.5+4 (40 1kHz) |
||
|
|
||
Crest factor |
40A |
3 (50/60Hz) |
|
Resistance |
200Ω |
1.2+4 , Beeps at below 30Ω(continuity check) |
|
■General Specifications
Parameter |
Specification |
|
Method of detection |
True RMS |
|
Display |
LCD(Digital display:1999 counts) |
|
Response time |
Approx. 1 second |
|
|
(approx. 2 seconds on resistance renge) |
|
Range switching |
Manual-range |
|
Data hold |
On all range |
|
Ambient temperature and humidity |
-10-50 , (no condensation) |
|
|
up to 30 , 90%RH |
|
|
up to 40 , 75%RH |
|
|
up to 50 , 45%RH |
|
Temperature coefficient |
- |
|
Influence of external magnetic field |
2A or less at 400A/m |
|
Influence of conductor position |
±3% or less |
|
Safety standard |
Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
|
Circuit voltage |
600Vrms or less |
|
Withstanding voltage |
5.55kV AC for one minute |
|
Power supply |
6F22(006P)9V ×1 or 6LR61 ×2 |
|
Battery life |
Approx. 200 hours (continuous) |
|
Consumed current |
Approx. 2mA |
|
Auto power-off |
Approx. 10 minutes |
|
Diameter of measurable conductor |
30mm at maximum |
|
Dimensions |
Approx. 93(W)×210(H)×40(D)mm |
|
Weight |
Approx. 400g |
|
Accessories |
User's manual(IM CL130), |
|
|
batteries, carrying case(93032) |
|
CL150 |
AC A |
|
|
|
54 |
|
AC/400~2000A |
|
AC V/DC V/ |
●Mean value display
●DC output function
●Data hold function
●Sleep function
●Approved for comformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)
■Specifications
At 23 ±5 75%RH or less Accuracy:±( % rdg + dgt) = ±(% readout + value of least significant digit)
Parameter |
Reference |
Accuracy |
|
AC current |
400A |
1.0+3 (50/60Hz) |
|
|
2.0+3 (40 1kHz) |
|
|
|
|
||
|
2000A(0 1500A) |
1.0+3 (50/60Hz) |
|
|
3.0+3 (40 1kHz) |
|
|
|
|
||
|
2000A(1500 2000A) |
3.0(50/60Hz) |
|
AC voltage |
40/400/750V |
1.0+2 (50/60Hz) |
|
|
1.5+3 (40 1kHz) |
||
|
|
||
DC voltage |
40/400/1000V |
1.0+2 |
|
Resistance |
400/4k/40k/400kΩ |
1.5+2 , Beeps at below 50±35Ω(continuity check) |
|
DC output |
400A(0 400mV) |
±1.5% rdg ±0.5mV (50/60Hz) |
|
|
±2.5% rdg ±0.5mV (40 1kHz) |
||
|
|
||
|
2000A(0 150mV/0 1500A) |
±1.5% rdg ±0.5mV (50/60Hz) |
|
|
±3.5% rdg ±0.5mV (40 1kHz) |
||
|
|
||
|
2000A(150 200mV/1500 2000A) |
±3.5% rdg (50/60Hz) |
|
■General Specifications
Parameter |
Specification |
|
Method of detection |
Mean value |
|
Display |
LCD(Digital display:3999 counts) |
|
Response time |
Approx. 2 seconds |
|
Range switching |
Manual-range(on AC current range)/ |
|
|
Auto-range(on AC voltage range, resistance range) |
|
Data hold |
On all range |
|
Peak hold |
On AC current range |
|
Ambient temperature and humidity |
0-40 , 85% RH or less (no condensation) |
|
Temperature coefficient |
- |
|
Influence of external magnetic field |
1A or less at 400A/m |
|
Influence of conductor position |
±(2.0% rdg + 3dgt) or less |
|
Safety standard |
Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
|
Circuit voltage |
1000Vrms or less |
|
Withstanding voltage |
5.55kV AC for one minute |
|
Power supply |
R6P(SUM-3) ×2 or LR6 ×2 |
|
Battery life |
Approx. 150 hours (continuous) |
|
Consumed current |
Approx. 5mA |
|
Sleep function |
Automatically powered down in about 10 minutes |
|
|
after the last switch operation |
|
Diameter of measurable conductor |
54mm at maximum |
|
Dimensions |
Approx. 105(W)×247(H)×49(D)mm |
|
Weight |
Approx. 470g |
|
Accessories |
User's manual(IM CL150), batteries, |
|
|
carrying case(93034) |
|
2