Yealink W90D, W90B Quick Start Guide

http://support.yealink.com/
W90 DECT IP Multi-Cell System
Quick Start Guide
For W90DM/W90B rmware 130.85.0.15 or later
For W59R rmware 115.85.0.20 or later
For W53H rmware 88.85.0.20 or later For W56H rmware 61.85.0.20 or later
For CP930W rmware 87.85.0.20 or later
For DD phone rmware 66.85.0.15 or later
Table of Contents
English ..........................................1
Deutsch ........................................7
Español ......................................13
Français .....................................19
Package Contents
+
+
2
2
(0.118”)
SN/MAC/RF
PI
La
bel
100mm
I
nter
net
DC5V
Quick Start Guide
Installation
1. Connect the power and the network.
a. AC Power Option
Label
100mm
SN/MAC/RFPI
Internet
DC5V
InternetDC5V
b. PoE (Power over Ethernet) Option
IEEE 802.3af compliant PoE Hub/Switch
InternetDC5V
Note:
If you choose method a, use Yealink supplied power adapter (5V/1.2A). A third-party power adapter may damage the device.
If you choose method b, you do not need to connect the power adapter. Make sure the hub/switch is PoE-compliant.
2. Mount W90DM/W90B on the wall.
Optional
E N G L
I S H
S
N/M A C/RFP
I
100mm
Label
30 mm
Max:4.5mm (0.177”)
25 mm
Max:3mm
Max:8mm (0.315”)
Min:6.5mm (0.256”)
100mm
1
E
3. Adjust the antenna angle.
N G L
I S H
180°
90°
Dening the Device Role
The W90DM is shipped as a DECT Manager (DM) and the W90B is shipped as a base station.
Base Mode Options
The following shows the LED status after the W90DM/W90B connects to the power and network:
Base Mode
Option
1 Base Green Green Off 2 DM Green Orange Off
Role LAN LED ROLE LED DECT LED
Accessing the Web User Interface
1. Do one of the following:
Find the current IP address of the device on the DHCP server in the list of registered DHCP clients.
Find the current IP address of the device through a PC scanning tool - Yea­link Discovery Tool.
2. Open a web browser on your computer, enter the IP address into the address bar (for example, "http://192.168.0.10" or "192.168.0.10"), and then
press the Enter.
3. Enter the user name (default: admin) and password (default: admin) in the login page and click Login.
2
Regulatory Notices
Operating Ambient Temperatures
Operating temperature: +32 to 104°F (0 to 40°C)
Relative humidity: 5% to 90%, noncondensing
Storage temperature: -22 to +160°F (-30 to +70°C)
Warranty
Our product warranty is limited only to the unit itself, when used normally in accordance with the operating instructions and the system environment. We are not liable for damage or loss resulting from the use of this product, or for any claim from a third party. We are not liable for problems with Yealink device arising from the use of this product; we are not liable for nancial damages, lost prots, claims from third parties, etc., arising from the use of this product. DC symbol
is the DC voltage symbol.
Restriction of Hazardous Substances Directive (RoHS) This device complies with the requirements of the EU RoHS Directive. Statements of compliance can be obtained by contacting support@yealink.com. Safety Instructions
Save these instructions. Read these safety instructions before use!
To reduce risk of re, severe personal injury and damage to property, read the following safety information carefully before using the product.
Environmental Requirements
Place the product on a stable, level and non-slip surface.
Do not place the product close to heat sources, in direct sunlight or next to any
house hold appliance with strong magnetic eld or electromagnetic eld, such as a microwave oven or a refrigerator.
Do not allow the product to come into contact with water, dust and chemicals.
Protect the product from aggressive liquids and vapors.
Do not place the product on or near any inammable or re-vulnerable object, such
as rubber-made materials.
Do not install the product in rooms with high humidity, for example, in bathrooms, laundry rooms and wet basements.
Safety Notes During Operation
E N G L
I S H
Use only spare parts and accessories supplied or authorized by Yealink. The operation of non-authorized parts cannot be guaranteed.
Do not place heavy objects on top of the handset or the base station in case of dam age and deformation caused by the heavy load.
Do not open the handset or the base station by yourself for repair purpose, which could expose you to high votages. Have all repairs carried out by authorized service
personel.
Addr: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C
Tel: +86-592-5702000
Fax: +86-592-5702455
3
E
Do not let a child operate the product without guidance.
N G
Keep the small accessories contained in your product out of reach of small children in case of accidental swallowing.
L
I
Before plugging or unplugging any cable, make sure that your hands are completely
S
dr y.
H
Do not hold the handset up to your ear when speakerphone is on or when the ringer is ringing as the volume can be very loud, which may be harmful to your hearing.
During a thunderstorm, stop using the product and disconnect it from the power supply to avoid lightning strike.
If the product is left unused for a rather long time, disconnect the base station from the power supply and unplug the power adapter.
When there is smoke emitted from the product, or some abnormal noise or smell, disconnect the product from the power supply, and unplug the power adapter
immediately.
Remove the electrical cord from an outlet by pulling gently on the power adapter,
not by pulling the cord.
Notices of Cleaning
Before cleaning the base station, stop using it and disconnect it from the power supply.
Remove the battery before cleaning the handset to reduce risk of electric shock.
Only clean your product with a piece of slightly moist and anti-static cloth.
Keep the power plug clean and dry. Using a dir ty or wet power plug may lead to electric shock or other perils.
Addr: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C
4
Tel: +86-592-5702000
Fax: +86-592-5702455
ENVIRONMENTAL RECYCLING
Never dispose of the device with domestic waste
Ask your Town Council about how to dispose of it in an environmentally friendly way. The cardboard box, plastic packaging and player compo­nents may be recycled in accordance with prevailing recycling regula-
tions in your country.
Always adhere to prevailing regulations
Those who fail to do so may be ned or prosecuted in accordance with the law. The crossed out garbage can that appears on the device means that when it has reached the end of its useful life, it should be taken to a special waste disposal center and treated separately to general urban waste.
Troubleshooting The unit cannot supply power to Yealink device. There is a bad connection with the plug.
1. Clean the plug with a dry cloth.
2. Connect it to another wall outlet. The usage environment is out of operating temperature range.
1. Use in the operating temperature range. The cable between the unit and the Yealink device is connected incorrectly.
1. Connect the cable correctly. You cannot connect the cable properly.
1. You may have connected a wrong Yealink device.
2. Use the correct power supply. Some dust, etc., may be in the port.
1. Clean the port. Contact your dealer or authorized service facility for any further questions. Contact Information YEALINK NETWORK TECHNOLOGY CO.,LTD. 309, 3rd Floor, No.16, Yun Ding North Road, Huli District, Xiamen City, Fujian, P.R.C YEALINK (EUROPE) NETWORK TECHNOLOGY B.V. Strawinskylaan 3127, Atrium Building, 8th oor, 1077ZX Amsterdam, The Netherlands YEALINK (USA) NETWORK TECHNOLOGY CO., LTD. 999 Peachtree Street Suite 2300, Fulton, Atlanta, GA, 30309, USA
Made in China
E N G L
I S H
Addr: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C
Tel: +86-592-5702000
Fax: +86-592-5702455
5
E
NAME: DATE
TITLE:
N G L
I S H
We, YEALINK(XIAMEN) NETWORK TECHNOLOGY CO.,LTD, Address: 309, 3rd Floor, No.16, Yun Ding North Road, Huli District, Xiamen City, Fujian, P.R.C
CE DATE: 20th /September/2020
declare that the product
Type: DECT IP Multi-Cell Base Station, DECT IP Multi-Cell Dect Manager Model: W90B,W90DM
meets the essential requirements and other relevant provisions according to the following EC directive Directive: 2014/30/EU, 2014/35/EU, RED 2014/53/EU; The presumption of conformity with the essential requirement is ensure according to: Article 3.1 a : (protection of the health &the safety of the user) Safety: EN 62368-1:2014/AC2015 SAR: ETSI EN 50385:2017 Article 3.1 b : (protection requirement with respect to electromagnetic compatibility) EMC: EN55032:2012+AC:2013 and EN55032:2015+AC2016 EN55035:2017 EN301489-6 V2.2.2,EN301489-1 V2.2.2 Article 3.2 (effective use of the radio spectrum) Radio: ETSI EN 301406 V2.2.2 Directive 2011/65/EU and (EU)2015/863 of the European Parliament and of the Council of 8 June 2011 and 4 June 2015 on the restriction of the use of certain hazardous substanc­es in electrical and electronic equipment(RoHS 2.0) Directive 2012/19/EU of the European Parliament and of the Council of 4.July.2012 on Waste electrical and electronic equipment(WEEE) Regulation (EC) No.1907/2006 of the European Parliament and of the Council of 18. December.2006 on Registration, Evaluation, Authorization, and Restriction of Chemicals (REACH)
Declaration of Conformity
YEALINK (XIAMEN) NETWORK TECHNOLOGY CO.,LTD
WWW.YEALINK.COM
Stone Lu 20/Sep
/2020
:
Vice President
Addr: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C
6
YEALINK (EUROPE) NETWORK TECHNOLO­GY B.V Address: Strawinskylaan 3127, Atrium Building, 8th oor, 1077ZX Amsterdam, the Netherlands Telephone: +31(0)646111373 Email: EUROPE@Yealink.com
Tel: +86-592-5702000
Fax: +86-592-5702455
Verpackungsinhalt
+
+
2
2
(0.118”)
SN/MAC/RF
PI
La
bel
100mm
I
nter
net
DC5V
Quick Start Guide
Optional
Montage
1. Stellen Sie die Stromversorgungs- und Netzwerkverbindung.
a. Option Wechselstromversorgung
Label
100mm
SN/MAC/RFPI
Internet
DC5V
InternetDC5V
b. Option Power-over-Ethernet (PoE)
IEEE 802.3af-konform PoE Hub/Switch
InternetDC5V
Hinweis:
Wenn Sie sich für Methode a entscheiden, verwenden Sie das von Yealink mitgelieferte Netz­teil (5V/1,2A).
Die Verwendung von Netzteilen anderer Hersteller kann das Gerät beschädigen.
Wenn Sie sich für Methode b entscheiden, müssen Sie das Netzteil nicht anschließen. Stellen
Sie sicher, dass der Hub/Switch PoE-konform ist.
2. Montieren W90DM/W90B an der Wand.
D E U T S C H
S N/M A
C/RFP
I
100mm
Label
30 mm
Max:4.5mm (0.177”)
25 mm
Max:3mm
Max:8mm (0.315”)
Min:6.5mm (0.256”)
100mm
7
Loading...
+ 19 hidden pages