To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
All rights reserved. No part of this publication may be reproduced,
stored in a retrieval system, or transmitted, in any form or by any
means, mechanical, electronic, photocopying, recording, or
otherwise, without the prior written permission of Yaskawa. No
patent liability is assumed with respect to the use of the
information contained herein. Moreover, because Yaskawa is
constantly striving to improve its high-quality products, the
information contained in this manual is subject to change without
notice. Every precaution has been taken in the preparation of this
manual. Yaskawa assumes no responsibility for errors or
omissions. Neither is any liability assumed for damages resulting
from the use of the information contained in this publication.
4 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
1 Preface and Safety
J1000
1 Preface and Safety
◆ Applicable Documentation
The following manuals are available for the RS-232C Interface
Option:
Option Unit
Yaskawa AC Drive -RS-232C Interface
Option Technical Manual
Read this manual first.
The Technical Manual is packaged with the
RS-232C Interface Option and contains a
basic overview of wiring, settings, functions,
and fault diagnoses.
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 5
1 Preface and Safety
Yaskawa Drive
U.S. and Europe:
Yaskawa AC Drive
J1000 Quick Start
Guide
Other areas:
Yaskawa AC Drive
J1000 Installation &
Start-Up Manual
Yaskawa AC DriveJ1000
Technical Manual
To obtain instruction
manuals for Yaskawa
products access these
sites:
U.S.: http://
www.yaskawa.com
Europe: http://
www.yaskawa.eu.com
Japan: http://www.emechatronics.com
Other areas: contact a
Yaskawa representative.
For questions, contact the
local Yaskawa sales
office or the nearest
Yaskawa representative.
◆ Terms
Note: Indicates a supplement or precaution that
does not cause drive damage.
Drive:Yaskawa AC Drive -J1000 Series
Option:
6 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
Yaskawa AC Drive -J1000 RS-232C Interface
Option
1 Preface and Safety
DANGER
W ARNING
◆ Registered Trademarks
• Other company names and product names listed in this manual
are registered trademarks of those companies.
◆ Supplemental Safety Information
Read and understand this manual before installing, operating, or
servicing this option unit. The option unit must be installed
according to this manual and local codes.
The following conventions are used to indicate safety messages in
this manual. Failure to heed these messages could result in serious
or possibly even fatal injury or damage to the products or to related
equipment and systems.
Indicates a hazardous situation, which, if not avoided, will
result in death or serious injury.
Indicates a hazardous situation, which, if not avoided, could
result in death or serious injury.
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 7
1 Preface and Safety
CAUTION
NOTICE
Indicates a hazardous situation, which, if not avoided, could
result in minor or moderate injury.
Indicates an equipment damage message.
8 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
2 Receiving
2 Receiving
◆ Receiving
Confirm the packaging after receiving the RS-232C Interface
Option. If the wrong model is received or the RS-232C Interface
Option does not function properly, contact your supplier.
Components packaged with the option:
• The RS-232C Interface for copy unit/PC communication (SI232/J or SI-232/JC)
• Technical manual
◆ Additional Parts (Sold Separately)
Option
Drive Wizard
Plus
PC Interface
Cable
USB Copy UnitJVOP-181
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 9
Part
Number
-
WV103D-sub 9 pin - RJ-45
Comments
Available for download from
e-mechatronics.
www.e-mechatronics.com
for
or at www.yaskawa.com in the
U.S.
Provided with an RJ-45 cable
and a USB cable
2 Receiving
Blade width
3.0 mm max.
0.6 mm max.
Blade thickness
Option
LED OperatorJVOP-182
LED Operator
Cable
Part
Number
1 meter:
WV001
3 meter:
WV003
Comments
Available soon
(Contact Yaskawa for detail)
CAT5e UTP straight-through
cable with RJ-45 8 pin
connector
◆ Tool Requirements
Use a flat-blade screwdriver with the dimensions below for
installation or removal of the option cover and RS-232C option.
10 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
3 Product Overview
3 Product Overview
◆ About this Product
The RS-232C Interface Option allows the drive to be connected to
a network or external device.
Possible connected devices include:
• LED Operator
• Personal computer using DriveWizard Plus
•USB Copy Unit
These devices can be used to edit, view, and copy parameter
settings in the drive.
SI-232/JC can be more easily connected and disconnected than SI232/J. This is useful when copying parameter settings between
multiple drives.
◆ Applicable Models
The RS-232C Option can be used with Yaskawa drive models in
the table below.
DriveDrive Software Version <1>
CIMR-JABA≥1010
<1> See “PRG” on the drive nameplate for software version
number.
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 11
4 Option Components
4 Option Components
Figure1
A
J1000
B
C
D
A – RJ-45 PortC – Option
B–Option
Model
<1> Connection tabs are found only on the RS-232C interface (SI-
232/J).
12 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
Number
Connector to
Drive
D – Connection
Tab s
<1>
4 Option Components
◆ Dimensions
The installed Option interface adds 17.8 mm (0.70 in) to the total
depth of the drive.
2.8(0.11)
15(0.60)
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 13
mm(in)
5 Installation Procedure
DANGER
5 Installation Procedure
◆ Section Safety
Electrical Shock Hazard
Disconnect all power to the drive, before servicing.
Failure to comply will result in death or serious injury.
Wait at least one minutes after all indicators are off. The drive
has internal capacitors that remain charged even after the 24 V
Power Supply option is disconnected. The drive charge LED
will extinguish when the DC bus voltage is below 50Vdc.
Measure drive DC bus voltage to confirm safe level.
14 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
5 Installation Procedure
NOTICE
Damage to Equipment
Use only Yaskawa connection cables or recommended
cables.
Failure to comply may cause the drive or option to function
incorrectly.
Properly connect the connectors.
Failure to comply may prevent proper operation and possibly
damage equipment.
Do not exceed communication cable bend radius
specifications.
Failure to comply may result in broken wires or loose
connections.
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 15
5 Installation Procedure
Ta b
CN5 port
flat-blade
screwdriver
TababTa b
◆ Attaching the Option Interface
1. Insert a flat-blade screwdriver into the
opening as shown in the diagram below to
remove the option cover from the drive.
2. Insert the connector on the back of the
interface into the CN5 port on the drive so
that it clicks into place.
Note: The RS-232C Interface (SI-232/J) has three
additional connection tabs that must also
click into place to properly mount the
option.
16 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
5 Installation Procedure
J1000
underside of
interface unit
flat-blade
screwdriver
◆ Removing the option interface
1. Use a flat-blade screwdriver as shown in
the diagram to press gently against the
small openings and disconnect the option
unit.
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 17
5 Installation Procedure
Copy
Ver
ify
Read
LOCK
YASKAWA
JVOP-181
USB Copy Unit
COM ERR
CN5
<2>
<3>
<4><1>
SI-232/JC
USB Copy Unit
SI-232/J
or
LED Operator
(Available soon)
DriveWizardPlus
connect
AC drive J1000
J1000J1000
◆ Connecting Peripheral Devices to the
RS-232C Interface Option
NOTICE: Only use specific cables recommended by
Yaskawa. Yaskawa cannot guarantee proper operation if
non-specified cables are used.
18 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
5 Installation Procedure
<1> Use the LED operator cable, WV001 or WV003.
<2> Only use the RJ-45 cable supplied with the USB Copy Unit.
<3> Only use the USB cable supplied with the USB Copy Unit.
<4> Only use the cable, PN: WV103, when connecting the drive
to a PC.
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 19
6 Related Drive Parameters
6 Related Drive Parameters
No.NameDescriptionDefault
Determines if the drive will
stop when the digital operator
Operation
Selection
o2-06
when Digital
Operator is
Disconnected
20 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
is removed in Local mode or
with b1-02 set to zero.
0: Disabled - The drive will
not stop when the digital
operator is removed.
1: Enabled - The drive will
fault (OPR) and coast to
stop when the digital
operator is removed.
0
7 Troubleshooting
7 Troubleshooting
Problems with the option interface may trigger an operator error.
Refer to the J1000 Technical Manual for all other errors.
◆ Fault
LED Operator
Display
oPrDigital operator connection fault
CausePossible solution
LED operator is
not properly
connected to the
drive or cables are
damaged
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 21
• Check the connection between the LED
operator and the drive
• Replace the cable if damaged
• Turn off the drive input power and
disconnect the LED operator
• Next reconnect the operator and turn the
drive input power back on
Fault Name
8 Specifications
8 Specifications
◆ Drive Specification
ItemSpecification
Model
Number
Storage/
Installation
Area
Ambient
Temperature
Humidity95% RH or less with no condensation
Storage
Temperature
Altitude1000 m or less
22 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
SI-232/J: RS-232C Interface for use with remote
digital operator
SI-232/JC: RS-232C Interface for use with copy
Indoors (an area free from oil mist and dust)
-10 to +50°C
-20 to +60°C allowed for short-term transport of
the product
Room 1011, Tower W3 Oriental Plaza, No. 1 East Chang An Ave.,
Dong Cheng District, Beijing, 100738, China
Phone: 86-10-8518-4086
YASKAWA ELECTRIC TAIWAN CORPORATION
9F, 16, Nanking E. Rd., Sec. 3, Taipei, 104, Taiwan
Phone: 886-2-2502-5003
YASKAWA ELECTRIC INDIA PRIVATE LIMITED
#17/A Electronics City, Hosur Road Bangalore 560 100 (Karnataka), India
Phone: 91-80-4244-1900
http://www.yaskawaindia.in
YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual 23
Fax: 55-11-5581-8795
Fax: 44-1236-458182
Fax: 82-2-784-8495
Fax: 65-6289-3003
Fax: 86-21-5385-3299
Fax: 86-10-8518-4082
Fax: 886-2-2505-1280
Fax: 91-80-4244-1901
(Address revision No.: 12-7-9)
10 Revision History
MANUAL NO. TOBP C730600 32A
Published in Japan May 2008 07-12
Date of
publication
Date of original
publication
Revision
number
1
65432
1
10 Revision History
The revision dates and numbers of the revised manuals are given
on the bottom of the back cover.
Date of
Publication
January 2013Chapter 9 Revision: Address
July 2011
September 2010Chapter 9 Revision: Address
April 2010Chapter 9 Revision: Address
July 2008Chapter 9 Revision: Address
May 2008Chapter 1
December 2007 ––First edition
24 YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual
Rev.
SectionRevised Content
No.
Front cover,
back cover
Revision: Format
Revision: Applicable
Documentation
YASKAWA AC Drive-J1000 Option
RS-232C Interface
Technical Manual
J1000オプションユニット
RS-232C
オプションユニット
取扱説明書
Any inquiries related to the product can be directed to the address listed at chapter 9.
この製品に関するお問い合わせ先については,9章お問い合わせ先をご覧ください。
In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture
thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations. Therefore, be sure to
follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply.
Specifications are subject to change without notice for ongoing product modifications and improvements.