PARTS LIST
BLOCK & LEVEL DIAGRAM (ブロック&レベルダイアグラム)
CIRCUIT DIAGRAM (回路図)
Copyright (c) Yamaha Corporation. All rights reserved. 08.06
MSR250
IMPORTANT NOTICE
This manual has been provided for the use of authorized Yamaha Retailers and their service personnel. It has been assumed that basic service
procedures inherent to the industry, and more specifically Yamaha Products, are already known and understood by the users, and have
therefore not been restated.
WARNING:Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruc-
tion of expensive components and failure of the product to perform as specified. For these reasons, we advise all Yamaha
product owners that all service required should be performed by an authorized Yamaha Retailer or the appointed service
representative.
IMPORTANT: This presentation or sale of this manual to any individual or firm does not constitute authorization, certification, recognition of
any applicable technical capabilities, or establish a principal-agent relationship of any form.
The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research engineering, and service
departments of Yamaha are continually striving to improve Yamaha products. Modifications are, therefore, inevitable and changes in specification are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributor’s Service
Division.
WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body may have accumulated by
IMPORTANT: Turn the unit OFF during disassembly and parts replacement. Recheck all work before you apply power to the unit.
WARNING: This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON WHAT SO
EVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux
vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before handling food.
grounding yourself to the ground bus in the unit (heavy gauge black wires connect to this bus).
IMPORTANT NOTICE FOR THE UNITED KINGDOM
Connecting the Plug and Cord
WARNING:THIS APPARATUS MUST BE EARTHED
IMPORTANT. The wires in this mains lead are coloured in accordance with the following code:
GREEN-AND-YELLOW:EARTH
BLUE:NEUTRAL
BROWN:LIVE
As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your
plug, proceed as follows:
The wire which is coloured GREEN and YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety
earth symbol or colored GREEN or colored GREEN and YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.
■ WARNING
Components having special characteristics are marked and must be replaced with parts having specification equal to those originally
installed.
6.Amplifier Assembly
(Time required: About 2 minute)
6-1Remove the ten (10) screws marked [30]. The amplifier
assembly can then be removed. (Fig. 5)
6-2Disconnect the connector assembly connected to the
connector CN546 (2P) of the MOTHER circuit board.
(Fig. 6)
7.MOTHER Circuit Board
(Time required: About 4 minutes)
7-1Remove the amplifier assembly. (See procedure 6.)
7-2Disconnect the connector assemblies connected to the
connectors CN541 (5P) and CN542 (5P) of the MOTHER
circuit board. (Fig. 6)
7-3Remove the three (3) screws marked [200A]. (Fig. 6)
7-4Remove the MOTHER circuit board from the connec-
tors 1100 (11P) and 1101 (10P) of the AMP circuit board.
(Fig. 6)
*The positive thermistor marked [171] and two
(2) black tubes marked [172] are not parts of the
MOTHER circuit board. When replacing the
MOTHER circuit board, be sure to remove these
parts and attach them to the new MOTHER circuit board.
8.INPUT circuit board
(Time required: About 6 minutes)
8-1Remove the amplifier assembly. (See procedure 6.)
8-2Remove the MOTHER circuit board. (See procedure 7.)
8-3Remove the three (3) screws marked [130], four (4)
hexagonal nuts and four (4) washers. (Fig. 7)
8-4Remove the INPUT circuit board from the connector
CN26 (6P) of the CONTROL circuit board. (Fig. 7)
*The push button marked [150] and push spacer
marked [155] are not parts of the INPUT circuit
board. When replacing the INPUT circuit board,
be sure to remove these parts and attach them
to the new INPUT circuit board.
9.CONTROL circuit board
(Time required: About 8 minutes)
9-1Remove the amplifier assembly. (See procedure 6.)
9-2Remove the MOTHER circuit board. (See procedure 7.)
9-3Remove the INPUT circuit board. (See procedure 8.)
9-4Disconnect the connector assembly connected to the
connector CN802 (3P) of the POWER-b circuit board.
(Fig. 8)
9-5Remove the four (4) screws marked [80A]. The CON-
TROL circuit board can then be removed. (Fig. 8)
*The six (6) volume knobs marked [160] are not
parts of the CONTROL circuit board. When replacing the CONTROL circuit board, be sure to
remove these parts and attach them to the new
CONTROL circuit board.
10.AMP Circuit Board
(Time required: About 7 minutes)
10-1Remove the amplifier assembly. (See procedure 6.)
10-2Remove the MOTHER circuit board. (See procedure 7.)
10-3Remove the INPUT circuit board. (See procedure 8.)
10-4 Remove the two (2) screws marked [200B]. The AMP
circuit board can then be removed. (Fig. 9)
11.POWER-b Circuit Board
(Time required: About 4 minutes)
11-1Remove the amplifier assembly. (See procedure 6.)
11-2Disconnect the connector assemblies connected to the
connectors CN801 (5P), CN802 (3P) and CN803 (2P)
of the POWER-b circuit board and the connector assembly connected to the connector CN541 (5P) of the
MOTHER circuit board.
11-3Remove the four (4) screws marked [80B]. The POWER-
[230]: PANHEADTAPPINGSCREW-B3x12CR3(WP927900)B タイト+ PAN
Fig. 11(図 11)
12
MSR250
13.Power Transformer and POWER-a Circuit Board
(Time required: About 5 minutes)
13-1Remove the amplifier assembly. (See procedure 6.)
13-2Disconnect the connector assemblies connected to the
connectors CN810 (2P), CN812 (2P) of the POWER-a
circuit board and the connector CN801 (5P) of the
POWER-b circuit board. (Fig. 12)
13-3Remove the four (4) screws marked [25]. The power
transformer can then be removed together with the
POWER-a circuit board. (Fig. 12)
13-4Unsolder the leads of the power transformer. The
POWER-a circuit board and power transformer can then
be separated.
*The three (3) fuses marked [31], [32] and [33] are
not parts of the POWER-a circuit board. When
replacing the POWER-a circuit board, be sure to
remove these parts and attach them to the new
POWER-a circuit board.