Xpelair Simply SilentTM
Illumi Shower Fan Complete
Installation and Maintenance Instructions
SSISFC100 (93087AW)
IMPORTANT - PLEASE READ
Do read the entire instruction leaflet before commencing installation.
Do check that the electrical rating shown on the unit matches the mains supply. Rating label is
located inside the back-plate.
This appliance is intended for connection to fixed wiring only, WITH A MAXIMUM FUSE RATING 5A.
Do install the product with a means for disconnection in all poles in the fixed wiring.
Do ensure the mains supply is switched off before attempting to make electrical connections or
carry out any maintenance or cleaning.
All installations must be supervised by a qualified electrician. Installations and wiring must conform
to current IEE Regulations (UK), local or appropriate regulations (other countries).
Please leave this leaflet with the product for the benefit of the user
UK customers:
If you have any queries before or after installing this product call the Xpelair Helpline on +44 [0]344
879 3588. Our engineers are there to help you during normal office hours.
Customers outside the UK:
Please contact your local Xpelair distributor.
1
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory
capabilities or lack of experience and knowledge, if they
have been given supervision or instruction concerning
the use of the appliance in a safe way and understand the
hazards involved.
Children shall not play with the appliance.
Cleaning and maintenance of the appliance shall not be
made by children.
Before any cleaning or maintenance, isolate the fan
completely from the mains supply.
A means of disconnection in all poles must be provided in the fixed
wiring in accordance with the wiring rules.
When the fan is installed in a room containing a fuel burning
appliance, precautions must be taken to avoid the backflow of
gasses into the room from the open flue of the burning appliance.
The Xpelair Simply SilentTM Illumi Shower Fan Complete has
the following features:
Single speed extraction
12 V (ac) fan operation
12 V (dc) light operation
When switched off, the fan continues to run for a pre-set delay from 30 seconds to 30 minutes
A transformer provides a Safety Extra Low Voltage (SELV) power supply.
THE APPLIANCE IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH CONNECTION.
The contents of this kit includes:
1x Xpelair Simply Silent
1x Safety Extra Low Voltage (SELV) Transformer
1x 3m flexible duct
1x External Wall Grill
2x Tie wraps
7x Screws and wall plugs
TM
Illumi Shower Fan Complete unit
2
FIGURE 2 - SELV Transformer Dimensions
FIGURE 1 - Unit Dimensions
Dimensions in mm
3
FIGURE 3 – Opening the unit
FIGURE 4 - Fixing positions
Dimensions in mm
4