PLEASE NOTE:
THE CANADIAN (CSA) VERSION OF THIS FAN IS RATED AT 95W THIS IS FOR CONNECTION TO TYPE B1 AND B2 FANS ONLY.
SEE "IDENTIFYING FAN TYPE" SECTION.
Low High
0I
45mm
210mm
86
m
m
86
m
m
208mm
Low High
0I
41mm
210mm
8
6m
m
8
1m
m
182mm
F1
F3
F4
F5
E
N
1
2
3
NF
3
21L N E
L
N
11
14
13
12
F2
N
L3
2 1
L
N
13
11
12
E N
NF
3
2
1
L
E N L
2
3
NF
E N
2 1
L3
L
N
12
13
11
1
9
5
4
3
8
2
1
6
7
10
F6
14
14
L N
A double pole isolating switch with a minimum contact
gap of 3mm (Wall or Ceiling mounted).
Suitably rated 5-core cable to connect the controller to
the fan. If the fan is window mounted, use flexible cable (Available from Xpelair).
Suitably rated 3-core cable to connect the controller to
the Main Electrical Supply.
If using flexible cable, suitable glands incorporating cable clamps must be fitted to the knockouts in the Controller Box. (Refer to Fig. 1).
These Instructions are for the Installation and Operation of the FR22/30 Fan Controller only. For Fan
Installation and Operating Instructions refer to literature provided with the appropriate fan.
♦♦
♦♦
Not where ambient temperatures are likely to exceed
50°C.
♦♦
♦♦
If installed in a kitchen the Controller must not be
mounted immediately above a cooker hood or eye level grill.
♦♦
♦♦
When intended for use in possible chemical corrosive
atmospheres, consult our Technical Service Department (Outside the UK contact your local Xpelair distributor).
♦♦
♦♦
If installed in a shower room or bathroom the
controller and isolating switch must be situated so that they cannot be touched by persons making use of the bath or shower.
This appliance is designed to control the operation of Xpelair fans of the GX9, GX12, WX9, WX12, RX9 & RX12 ranges (wall & window mounted). The controller may be either surface mounted, or recess mounted within it’s own patress box. You may only wire one fan to each controller.
For the purpose of these instructions current and previous versions of the fans are identified into Type A & Type B, as follows:
If wiring to Type A fans
A link is fitted between terminals 2 and 3 in the fan socket, this must be removed before connecting the Controller. If you do not remove it, the Controller will be permanently damaged.
If wiring to Type B fans
There is no wire link to be removed.
If the fan is already installed
1 Ensure the power supply is isolated. 2 Disconnect the mains connections from the fan’s
terminal socket or from the terminal block.
3 Remove the existing wiring and make it safe.
1 Route the 5-core cable from the Fan to the Controller
position.
2 Wire one end of the cable into the fan connections as
shown thus:
3 Leave the other end ready to be connected to the
Controller.
Type A1
Type A2
Type B1
Type B2
Location of the Controller
Wire the fan electrical connections
Description
What the installer will need
Identifying Fan Type
Preparing the Fan
General Information Working with the Fan
If the fan is not yet installed.
1 Check that the fan electrical rating matches the power
supply.
FAN TYPE
F1 F2 F3
DIAGRAM
Type A1 Type A2 Type B
Table 1.
If wiring to an existing installation isolate mains supply and remove applicable fuses prior to any electrical procedure.
FR22/30 Fan Controller Installation and
Operating Instructions
These installation instructions are for the installation of the controller when used in combination with Xpelair supplied fans.
The controller must be installed to fixed wiring. Ensure the Main Electrical Supply matches the rating shown on the controller casing.
This appliance must be earthed.
All installation must be supervised by a qualified electrician. Installation and wiring must conform to current IEE wiring regulations (UK), or local appropriate regulations (other countries).
If you have any queries either before, during and after the installation of the controller, please do not hesitate to contact the UK Xpelair hotline (number on back page). Customers outside the UK: contact your local Xpelair distributor.
Installing the Controller
Remove the Cover and Mounting Frame
Eye protection must be worn during all drilling & chiselling operations.
Check there are no buried Pipes or Cables in the wall or obstructions on the outside e.g. Electricity, Gas, Water.
Mounting the Wall Box
If surface mounting
1 Insert suitable glands into the knockouts. 2 Feed both cables through the glands. 3 Fix the Wall Box and Plastic Surround to the wall, using
the mounting holes provided.
4 Reconnect the earth lead to the Wall Box.
If recess mounting
1 Make a hole in the wall big enough to take the Wall Box.
Discard the Plastic Surround. 2 Insert suitable glands into the knockouts. 3 Feed both cables through these glands. 4 Fix the Wall Box to the wall. Ensure that the
flange of the mounting frame fits flush to the finished
surface of the wall (Refer diagram F6). 5 Reconnect the earth lead to the Wall Box.
Wire the Controller electrical connections
1 Mount the Isolation Switch in accordance with the
manufacturers instructions.
2 Wire the Controller to the Isolation Switch and to the Fan
as shown in the appropriate diagram (Refer to Table 1). 3 Refit Mounting Frame to Metal Wall Box. 4 Refit the Fascia to the Mounting Frame. 5 Refit the Screw Covers.
1 Ensure power supply is isolated and fuses are
removed.
2 Route the Cable from the Isolating Switch to the point of
connection to the power supply. 3 Make all connections within the Isolating Switch in
accordance with the manufacturers instructions. 4 Following all local regulations make connection at point of
power supply. 5 Make a final check to ensure all earth points are connected
and all covers have been correctly replaced on the fan,
controller and isolating switch. 6 Replace all fuses, and switch on the power supply.
For fixed wiring circuits the protective fuse for the appliance must not exceed 5 amps.
For Australia only:
These models are permanently connected to the supply & operation is controlled by a remote switch. They should be directly wired to the supply through an approved 10 amp wall mounted surface switch with at least 3mm clearance between contacts.
Mounting the Controller
1 Detach the Fascia from the Mounting Frame by removing
the screw covers and two screws (Refer to Fig. 2a&b).
2 Detach the Mounting Frame from the Wall Box by
removing the two screws (Refer to Fig. 2c). 3 Lift the Wall Box away from the Plastic Surround. 4 Check that the electrical rating shown inside the controller
matches the power supply. 5 Disconnect the earth wire from the Wall Box. 6 Make cable entry holes in the plastic and metal boxes by
removing suitable knockouts (Refer to Fig. 1).
Connect to Power Supply
Fig. 1 : Cable Gland Positions
Fig. 2a : Removing screw covers Fig. 2b:Removing fascia Fig. 2c: Removing mounting frame
Cleaning
1 Before cleaning isolate the Controller completely
from the power supply.
2 Wipe the Cover carefully with a damp cloth. 3 Dry thoroughly. 4 Ensure ventilation slots are free from obstuctions at all
times.
♦♦
♦♦
Never immerse the Controller in water or other liquids.
♦♦
♦♦
Never use solvents to clean the Controller.
♦♦
♦♦
Apart from cleaning, no other maintenance is required.
Looking after the Controller
Operating the Controller
Using your Controller
1 On / Off switch 2 Intake / Extract switch
3 High / Low speed
4 Indicator light 5 Ventilation slots 6 Screw cover 7 Fascia
8 Mounting Frame 9 Wall Box 10 Plastic Surround 11 Controllers Terminal Block 12 Fan’s Terminal Block 13 Double Pole Isolator switch 14 Fuses
The Controller has the following features: (Refer to diagrams F1-F4).
♦♦
♦♦
Deze niet aanbrengen waar de omgevingstemperaturen
50CN te boven gaan.
♦♦
♦♦
Wanneer in een keuken aangebracht mag de regelaar
niet direct boven een wasemkap of ooghoogte van de grill worden gemonteerd.
♦♦
♦♦
Wanneer bestemd voor gebruik in mogelijk chemisch
corrosieve atmosferen eerst onze Technische Service afdeling raadplegen. (Buiten GB: neem contact op met uw lokale Xpelair dealer).
♦♦
♦♦
Wanneer gemonteerd in een douche- of badkamer dan
moet de regelaar daar worden aangebracht waar zij niet kunnen worden aangeraakt door personen die de douche of het bad gebruiken.
Een tweepolige schakelaar met een minimum
contactafstand van 3 mm (muur- of plafondmontage).
Passende 5-aderige kabel om de regelaar aan de ventilator
aan te sluiten. Als de ventilator raam-gemonteerd wordt dan moet een flexibele kabel worden gebruiken. (Verkrijgbaar bij Xpelair).
Passende 3-aderige kabel voor de aansluiting van de
regelaar aan de hoofdstroomtoevoer.
Wanneer flexibele kabel wordt gebruikt moeten passende doorvoeren worden aangebracht via de uitbreekplaatjes in de doos van de regelaar. (Zie Afb. 1.)
Deze voorschriften zijn uitsluitend bestemd voor de installatie en bediening van de FR22/30 ventilator-regeleenheid. Voor de Installatie- en bedieningsvoorschriften van de ventilator gelieve u de met de betreffende ventilator meegeleverde literatuur te raadplegen.
Dit apparaat is bedoeld om de bediening te besturen van de Xpelair ventilatoren type GX9, GX12, WX9, WX12, RX9 & RX12 (wand- of raammontage). De regelaar kan of op een oppervlak worden gemonteerd, of in een uitsparing voor zijn eigen gegalvaniseerd metalen inbouwdoos. U mag enkel één ventilator aan elke regelaar aansluiten.
Ten behoeve van deze voorschriften worden de huidige en vroegere versies ventilatoren geïdentificeerd als Type A & Type B, zie hierna:
Bij aansluiting van Type A ventilatoren
In de contactdoos van de ventilator is tussen klem 2 en 3 een verbindingsdraad aangebracht die moet worden verwijderd voordat de regelaar wordt aangesloten. Als u de verbindingsdraad niet verwijderd zal dit permanente beschadiging van de regelaar tot gevolg hebben.
Bij aansluiting van Type B ventilatoren
Hier hoeft geen verbindingsdraad te worden verwijderd.
Als de ventilator reeds is geinstalleerd
1. Zorg ervoor dat de netvoeding is geisoleerd.
2. Maak de elektrische aansluitingen los van de klembus of van het klemmenblok van de ventilator.
3. Verwijder de bestaande bedrading en maak deze veilig.
Type A1
Type A2
Type B1
Type B2
Als de ventilator nog niet is geinstalleerd
1 Controleer of de toelaatbare nominale waarde van de
ventilator overeenkomt met de stroomtoevoer.
Wanneer de ventilator aan een bestaande installatie wordt aangesloten moet eerst de stroomtoevoer worden geisoleerd en van toepassing zijnde zekeringen worden verwijderd en wel voordat aan gelijk welke elektrische procedure wordt begonnen.
Installatie- en bedieningsvoorschriften
voor de regeleenheid van de FR22/30 Ventilator
Deze installatievoorschriften zijn bestemd voor de installatie van de besturingseenheid wanneer deze wordt gebruikt in combinatie met door Xpelair geleverde ventilatoren.
Deze regelaar moet aan vaste bedrading worden aangebracht. Zorg ervoor dat de hoofdstroomtoevoer overeenkomt met de toelaatbare nominale waarde als afgebeeld op het huis van de regelaar. Denk eraan, dit apparaat moet geaard zijn.
Alle installatiewerkzaamheden moeten worden verricht onder toezicht van een erkend elektricien. Installatie en aansluiting moeten worden uitgevoerd conform de huidige IEE reglementen (VK), of de lokaal van toepassing zijnde reglementen (andere landen).
Wanneer u voor, tijdens of na de installatie van de regelaar nog vragen mocht hebben, aarzel dan niet contact op te nemen met de GB hotline (voor nummer zie laatste bladzijde). Klanten buiten GB wordt aangeraden contact op te nemen met hun plaatselijke Xpelair dealer.
Beschrijving
Algemene informatie
Installeren van de regeleenheid
Nodig voor de installatie
Aanbrengen van de regeleenheid
Preparatie van de ventilator
Werken met de ventilator
Identificeren van het type ventilator
Bedrading van de elektrische aansluitingen
van de ventilator
1. Breng de 5-aderige kabel aan van de ventilator naar de regelaar.
2. Sluit één kant van de kabel aan in de aansluitingen van de ventilator, als hierna afgebeeld:
3. Maak de nadere kant klaar om aan de regelaar te worden
aangesloten.