Installation Preparation Document (for physical installation of the product only)
Xerox DocuTech 6155/6180
Customer Support
The Xerox Customer Support Center is available to provide general
information, answer questions, and take service calls. You can reach
the Customer Support Center at the following toll-free phone number:
Your Xerox Analyst will provide fee-based training upon request.
United States 1-800-821-2797
Space Requirements / Service Envelope
The components of the DocuTech 6180 system are:
• DocuSP Controller (monitor, keyboard, mouse)
• Printer
D
DocuTech 61xx
WIDTH
Representation only.
Note: The 6155 and 6180 are available with and without a stand to
support the controller. If a stand (098S04797) is ordered, it will be
positioned to the left of the printer, within the service space envelope.
If no stand is ordered, the controller will be placed on the floor to the
left of the printer in the service space envelope.
Note: The dimensions shown below provide the overall service
space required, including the space to the nearest obstruction. The
dimensions are in inches and are absolute minimums
Configuration
6155, 6180 with
interposer and
finisher
With stand Without stand
Width Depth Width Depth
243.0" 114.0” 240.0” 114.0"
E
P
T
H
Electrical Requirements – DocuTech 6155 / 6180
For the printer one (1) electrical service option is available – 2-phase,
dual power cord.
Voltage 208/240(4 wire) 208/240 (4 wire)
Amperage 50 30
Cycles 60 Hz 60 Hz
Receptacle Xerox Part No. 600S3779 600S3277
Receptacle NEMA Part No. 14-50R 14-30R
Receptacle Diagram
Power Cord Kit Number 98K59581
Power Cord Length 15 feet 15 feet
MultiSource
2-phase, dual power cord
configuration
Electrical Requirements
Digital Front End (DFE) Controller Platform:
Line Options: Dedicated
Voltage 110
Amperage 15
Cycles 60 Hz
15 amp Receptacle Xerox Part No.
20 amp Receptacle Xerox Part No.
Receptacle NEMA Part No. 5 - 20R or 5 - 15R
Receptacle Diagram
600S3704
600S3703
or
• All controller configurations require a 110VAC, 15 Amp
grounded receptacle for the outlet strip that provides
for the
controller and its peripheral devices (monitor, modem,
CDROM drive, and tape drive)
• Adapters that eliminate the ground connection to the outlet can
not be used.
• Xerox provides 15 feet of cabling with Teflon coating (Plenum
rated), to connect the controller to the Processor/Finisher.
receptacles
Environmental Requirements
Temperature 68o F – 76oF
Humidity 45% +/-10% 30% RH 60% RH
Heat Emission –
with Binder On
(with processor,
interposer, finisher
and binder)
Heat Emission –
with Binder Off
(with processor,
interposer, finisher
and binder)
Altitude (above
sea level)
* The system will inhibit software problems and shut down above 90 o F
Recommended Min. Max.
o
F
(20o C-24o C)
- 14,185
- 13,609
Up to 6,000 ft. - 9,000 ft.
50
(10o C)
BTU/Hr
(with vent kit)
BTU/Hr
(with vent kit)
o
F*
85
(29o C)
22,165
BTU/Hr
(Running)
21,265
BTU/Hr
(Running)
701P43858
June 2005
Please ensure electrical, space, and supplies are available prior to equipment delivery.
Installation Preparation Document (for physical installation of the product only)
Xerox DocuTech 6155/6180
Installation Considerations
• There should be a minimum of 78 inches (1,981mm) clearance
from the floor to the nearest overhead obstruction.
• Dedicated power outlets are required. Ensure each power cord
has a separate circuit that cannot be shared with other devices.
• Electrical outlet must be located within 13.1 feet of the
equipment.
• Mobility Assist Device - The optional mobility assist device
reduces the installation clearance required to 30
inches
(760mm) at the processor end of the printer and 15 inches (380
mm) at the finisher end.
• For proper operation, the printer must be perfectly level. The
floor must be level within 2 degrees in any direction. On floors
less than 2 degrees out of level, installation personnel install a
leveling kit to level the machine.
• If the floor is more than 2 degrees out of level, this condition
cannot be corrected by the leveling kit. Another suitable location
must be found for the printer to be installed properly.
• A minimum 50-inch clearance of exclusive operator area must
be maintained in front of each component. This space cannot
be shared.
• A minimum of 36 inches of clearance in the back of each
component for general service clearance.
Physical requirements
• The DocuSP Controller Monitor and Keyboard are designed to
be positioned on top of the DocuTech 61XX printer. The
controller platform is designed to either be mounted in a stand to
the left of the printer, or to be positioned on the floor to the left of
the printer
• Warning: Due to safety requirements, under no circumstances
should the user interface be visually separated from the printer
module. All system installations must enable mobility of the user
interface to within 30” (760 mm) of the printer for service and
customer maintenance actions
.
Operating Supplies
Reorder No. Impressions / Unit
Dry Ink 6R206 220,000 / Carton
1
Developer 5R161 600,000 / Carton
Fuser Agent 8R2955 250,000 / Bottle
Stitcher Wire 8R1174 32,000 / Reel
Binder Tape - Black 8R2928 425 Binds / Reel
Binder Tape - White 8R3601 425 Binds / Reel
Binder Tape - Gray 8R3602 425 Binds / Reel
Binder Tape - Blue 8R3603 425 Binds / Reel
Binder Tape - Brown 8R3604 425 Binds / Reel
Binder Tape - Red 8R3824 425 Binds / Reel
1
Expected dry ink yield is based on 6% coverage on letter paper. Actual
usage will vary widely with % area coverage, density settings, and paper size
used.
The US supplies Marketing Center, 1.800.822.2200 is available for ordering all
Xerox supplies, including paper and throughput material
.
Network Requirements
• The Ethernet interface on the DocuSP controller is a 10/100-
MB/sec twisted pair standard (10BaseT).
• The Ethernet connection to the DocuSP controller must be
compatible with the Institute of Electrical and Electronics
Engineers (IEEE) 802.3 standard. (The physical form of this
connector is RJ45 and must be correctly wired.)
• The DocuSP controller supports TCP-IP, SPX/IPX, and
EtherTalk Link Access Protocol (ELAP) protocols if the proper
gateways are installed on the controller.
• The DocuSP controller does not provide Novell
Server network
services. To use the SPX/IPX protocol, a Novell server installed
on the network is required.
• A Xerox Token Ring solution is available for the 61XX family.
When Token Ring is installed, it becomes a Token Ring
only
connectivity solution. The NetWare gateway and AppleTalk
gateway will not function, and the built in Ethernet bge0 twisted
pair interfaces are disabled. (Gigabit Ethernet is supported –
some customers have asked for this option.)
Telephone Requirements
A voice telephone line is required where the DocuTech 6155 or 6180
is installed.
Voice line will be used when the operator, administrator, or Xerox
Service Personnel is asked to read the screen information from the
DocuSP controller dialogs to Xerox Customer Support or Technical
Support Center Personnel.
Position / Performance at Maturity
UM*
C
14
a
l
12
l
A
s
10
v
e
P
8
r
e
a
r
6
g
e
M
o
n
1
t
h
*Unscheduled Maintenance
Note:
• This product is targeted for the 1.8 to 6.0 million impressions per
month market segment. Usage above this range may result in a
higher service frequency.
• Variables other than monthly print volume affect average
number of service calls. Please contact your sales
representative or Customer Service Engineer for more
information.
1M 4M 6M
2M
Average Monthly Print Volume
Optimum Range
3M 5M
(M = Million)
701P43858
June 2005
Please ensure electrical, space, and supplies are available prior to equipment delivery.