Xantrex Technology 84-2009-01 User Manual

Xantrex Alternator Regulator
Regulates 12 volt P-Type Alternators
Designed for Mobile Power Applications
The Xantrex Alternator Regulator turns a high output alternator into an intelligent source of charging. Multistage regulation provides optimal charging voltage for common battery types including flooded, gel, AGM and Optima batteries.
With optional alternator and battery temperature sensors installed, the Xantrex Alternator Regulator protects against heat stress on the batteries and alternator, while maximizing charging performance. Start delay and soft ramp features reduce belt and engine wear, and the Amp Manager function adjusts the maximum alternator output.
Product Features
Selectable charging programs for gel, AGM , and optima deep-cycle flooded batteries
User programmable system time and voltage values
Equalization mode
Color coded LED display
Industry standard wiring harness and detailed installation instructions
Encapsulated for resistance to marine environment
One year warranty
Programmable Advanced Functions
Optional Battery Temperature Sensor regulates charging based on battery temperature
Optional Alternator Temperature Sensor protects against alternator overheating
Xantrex Technology Inc.
Headquarters 8999 Nelson Way Burnaby, British Columbia Canada V5A 4B5 800 670 0707 Toll Free 604 420 1591 Fax
5916 195th Street NE Arlington, Washington USA 98223 800 446 6180 Toll Free 360 925 5144 Fax
www.xantrex.com© 2003 Xantrex Technology Inc. All rights reserved. Xantrex is a registered trademarks of Xantrex International. Part Number 970-5049-01-01 Rev. B Printed in Canada
Xantrex Alternator Regulator
Regulates 12 volt P-Type Alternators
Specications
Output current 6 A
Available voltages 12 V and 24 V
Voltage regulation +/-3%
Dimensions (H x W x D) 4.9 x 3.25 x 1.5”
Weight 1 lb
Warranty One year
Part number 84-2006-01 (12 V alternator regulator)
84-2009-01 (24 V model available - see manual fo specifications)
76-2006-01 (optional battery temperature sensor)
76-2006-02 (optional alternator temperature sensor)
84-6001-00 (“Zap stop” – high voltage spike suppressor for alternators)
Note: Specifications subject to change without notice.
Primary Program Settings Prg-1 Prg-2 Prg-3 Prg-4 Prg-5
Universal Deep Cycle Gell Cell Absorbed Glass Optima Sprial
Mode Factory Program Flooded Lead Acid Mat (AGM) Wound
Start Delay (seconds) 45 45 45 45 45
Ramp Up (seconds) 60 60 60 60 60
Bulk Voltage (maximum) 14.1 14.6 14.1 14.4 14.6
Bulk Time (miminum) 36 min. 36 min. 36 min. 36 min. 36 min.
Absorption Voltage 13.9 14.4 13.9 14.4 14.6
Absorption Time (minimum) 0.2 hr. 0.2 hr 0.2-2.0 hr. 0.2-2.0 hr. 0.2-2.0 hr.
Float Voltage 13.4 13.4 13.7 13.4 13.4
Float Time (maximum) 6 hr. 6 hr. 6 hr. 6 hr. 6 hr.
High Voltage Alarm 15.2 15.6 15.1 15.4 15.6
Low Voltage Alarm 12.8 12.8 12.8 12.8 12.8
Max. Battery Temperature 125° F/52° C 125° F/52° C 125° F/52° C 125° F/52° C 125° F/52° C
Max. Alternator Temperature 225° F/107° C 225° F/107° C 225° F/107° C 225° F/107° C 225° F/107° C
Equalization Yes Yes No Consult Mfg. Consult Mfg
Loading...