World Dryer J4, J4-162 Installation Manual

Operating Instructions and Parts Manual Model “J4”
Please read and save these instructions. Read carefully before attempting to a ssemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.
_____________________________________________________________________________
Description
World warm air hand dryer, powered by universal brush motor, delivers 1100 Watts of drying power. This hand dryer runs on 230 Volts AC electrical supply. An infrared sensor is used to automatically turn the dryer on and off. This model is intended for use in commercial, industrial, office and public facility environments.
General Specifications
Model Drying Cycle Dimensions Weight (W x H x D)
J4-162 Black Auto 8.9” x 10.6” x 6.4” 7.1 lbs J4-974 White Auto (22.6cm x 27cm x 16.2cm) (3.2 Kg) J4-970 Chrome Auto
Electrical Specifications
UL LISTED E320188
Model Type Electrical Input Amperage Watts
J4 Automatic 230VAC-50/60Hz 4.8A 1100
Unpacking
1. Remove all packing material.
Recycling is recommended.
2. Carefully remove the hand dryer from the shipping carton, using care not to drop the
appliance.
3. Inspect carefully for any damage that may have occurred during transit. Check for any
loose, missing or damaged parts. If the hand dryer is damaged, promptly inform the dealer where you purchased it.
68-300 Rev v.3
Printed in China
Operating Instructions and Parts Manual J4 WORLD DRYER AIRFORCE™
High Efficiency Hand Dryer
General Safety Information
DANGER Failure to disconnect the power source before installation can result in serious
injury or death from electric shock.
- Always disconnect the power source before servicing or installing the hand dryer.
DANGER Failure to properly ground this unit could result in severe electrical shock
and/or death
- This hand dryer must be properly grounded (Earthed) for safe operation. An identified
ground connection point is supplied on the chassis of the hand dryer.
- We recommend GFCI protection in wet or damp locations or as required by local code.
WARNING Risk of fire, personal injury or property damage are possible if local codes, or
safety recommendations are not followed.
- Use only the electrical power (voltage and frequency) specified for the model hand dryer
being installed.
- Connect the hand dryer to the nearest suitable distribution panel.
- To limit a voltage drop, and insure efficient operation, use No. 12 wire or larger as required
by local or National Electrical Code.
- Do not connect to a branch circuit with circuit breaker or fuse protection over 15 Amps.
- All automatic model hand dryers must have dedicated circuit.
- Route all field wiring away from moving parts within the hand dryer.
CAUTION Improper mounting could result in personal injury or property damage.
- Follow the mounting recommendations in Table 1.
- On a stud wall, one side of the hand dryer should be mounted to an existing stud.
Installation
1. Disconnect the power source.
2. Use the security hex key supplied to turn the cover mounting screws clockwise to remove
the cover from the dryer.
3. Place the hand dryer base on the wall at the desired location using Table 1 to determine the
recommended mounting height. With the base so located, use it as a template to mark locations of the 4 mounting bolt holes on the wall. Ensure that no reflective object (such as a hand basin) is located directly under infra-red sensor eye; the minimum distance is 18 inches (46 cm).
4. Fasten the base to the wall, using the type of bolts suggested in Table 2.
5. All automatic dryers must have their own dedicated 15 amp circuit.
6. Connect the dryer to the nearest suitable distribution panel.
7. Replace cover, turn screws counter-clockwise making certain not to over-tighten.
IMPORTANT: Consult local and general regulations before performing dryer installation. Ensure that the electrical network is not overloaded. Do not connect to a branch circuit over 15 amps.