Wolf RB36 User Manual

Item #_____________ C.S.I. Section 11420
MODEL: RB36
GAS SALAMANDER BROILER
BASIC MODEL: RB36 Gas salamander broiler.
Stainless steel front, top and sides. Six 11,000 BTU/hr bar-type burners with stainless steel
radiants; 66,000 BTU/hr total input.
Infinite heat control valve. Standing pilot ignition system. Chrome plated trigger grip control handle provides positive
positioning of the broiling carriage. Heavy-duty chrome plated broiling grid measures 27½"w x 13"d.
Removable full width spillage pan. ¾" top gas connection and gas pressure regulator. One year limited parts and labor warranty.
Model RB36
CSA design certified. NSF listed.
Approved by _______________________
OPTIONAL FEATURES:
Set of chrome wall mount brackets. Set of four 4" legs with adjustable feet.
DESCRIPTION:
Gas salamander broiler, Wolf Model No. RB36. Six 11,000 BTU/ hr bar-type burners with stainless steel radiants; 66,000 BTU/ hr total input. Infinite heat control valve. Pilot ignition system. Chrome plated trigger grip control handle provides positive positioning of the broiling carriage. Heavy-duty chrome plated broiling grid measures 27½"w x 13"d. Removable full width spillage pan. ¾" top gas connection and gas pressure regulator.
Exterior dimensions: 36"w x 19"d x 17½"h.
MODEL: RB36 Gas Salamander Broiler
Date: _____________________________
SPECIFY TYPE OF GAS WHEN ORDERING. SPECIFY ALTITUDE WHEN ABOVE 2,000 FT.
F-39078 (04-07)
Wolf Range Company Division of ITW Food Equipment Group LLC (800) 366-9653 www.wolfrange.com
Gas Salamander Broiler
INSTALLATION REQUIREMENTS:
1. A gas pressure regulator sized for this unit is included. Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2. Gas line connecting to appliance must be ¾" diameter or larger. If flexible connectors are used, the inside diameter must be the same as the ¾" iron pipe.
3. An adequate ventilation system is required for commer cial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org. When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accordance with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat­est edition). Copies may be obtained from The American Gas Association, Accredited Standards Committee Z223
Model RB36
-
@ 400N. Capital St. NW, Washington, DC 20001, or the Secretary Standards Council, NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or
exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR.
5. Clearances: Combustible Non-Combustible Rear 0" 0" Sides 6" 0" Bottom 10" 4"
Model Grid Rack No. of Total Approx. Shp. No. Width Depth Height (w x d) Burners BTU/hr. Wt. (lbs./kg)
RB36 36" 19" 17½" 27½" x 13" 6 66,000 180/81
NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39078 (04-07)
Loading...