Wolf Pwc542418r, Pwc482418r, Pwc362418r, Pwc422418r Installation Instruction

P R O W A L L C H I M N E Y V E N T I L A T I O N H O O D S
I N STA L L AT I O N I N S T RU C T I O N S
READ AND SAVE THESE IN STRUCTIONS
C O N TA C T I N F O R M A T I O N
Wolf Customer Service: 800-332-9513
Website: wolfappliance.com
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
READ AND SAVE THESE INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A)
Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
B)
Always turn hood ON when cooking at high heat or when flambéing food (crêpes suzette, cherries jubilee, peppercorn beef flambé).
C)
Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
D)
Use proper pan size. Always use cookware appropriate for the size of the surface element.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights informa­tion that is especially relevant to a problem­free installation.
WOLF®is a registered trademark of Wolf Appliance, Inc.
WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1)
SMOTHER FLAMES with a close-fitting lid, baking sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDI­ATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2)
NEVER PICK UP A FLAMING PAN—You may be burned.
3)
DO NOT USE WATER, including wet dish­cloths or towels—This could cause a violent steam explosion.
4)
Use an extinguisher ONLY IF:
A. You own a class ABC extinguisher and you know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit
*Based on kitchen fire safety tips published by NFPA.
W O L F P R O W A L L C H I M N E Y V E N T I L A T I O N H O O D S
I N S TA L L AT I O N R E Q U I R E M E N T S
IMPORTANT NOTE:
This installation must be completed by a qualified installer or Wolf authorized service center technician.
Installer:
Please read the entire Installation Instructions prior to installation. Save these instructions for the local inspector’s refer­ence, then leave them with the homeowner.
Homeowner:
Please read and keep these instructions for future reference and be sure to read the entire use & care information prior to use.
Any questions or problems about the installa­tion should be directed to your Wolf dealer or Wolf Appliance, Inc. at 800-332-9513. You can also visit our website at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be installed in accordance with national electrical codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A)
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B)
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
C)
Ducted fans must always be vented to the outdoors.
The hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it has cooled down. If the motor continues to shut off and restart, have the hood serviced.
AT I N G P L A T E
R I N F O R M AT I O N
Model Number
Serial Number
Record the model and serial numbers before installing the hood. Both numbers are listed on the rating plate, located on the back wall of the hood shell. Refer to the illustration below.
Rating plate located
inside back wall
Rating plate location
Dimensions in parentheses are in millimeters unless otherwise specified.
3
W O L F P R O W A L L C H I M N E Y V E N T I L A T I O N H O O D S
all Chimney Hood
W
Wall Chimney Hood (R) Rail Option
L I S T O F M AT E R I A L S
The following is a list of materials shipped with the Wolf pro wall chimney hood.
Stainless steel wall chimney hood
Transition with backdraft damper— attached inside hood (needs to be removed)
Decorative stainless steel rail and installa­tion components— (R) model hoods only
Two control knobs
Filters and grease cups (installed in hood)
Wood mounting strip
Installation package
Installation Instructions
Use & care information and product registration card
Wolf logo nameplate
I N S TA L L AT I O N C O N S I D E R A T I O N S
Wolf pro wall chimney ventilation hoods are recommended for use with all Wolf cooking appliances.
Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Wolf warranty. Refer to the Wolf pro ventilation hoods use & care information for warranty details, or visit the contact & support section of our website, wolfappliance.com.
Make sure you have the tools and materials necessary for proper installation.
Warranty service must be performed by a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation.
IMPORTANT NOTE:
Wolf pro ventilation hoods are shipped without the blower assembly. Wolf internal, in-line and remote blower assemblies are available, refer to page
17. Use only a Wolf blower with the pro wall chimney hood.
IMPORTANT NOTE:
Wolf recommends that the pro wall chimney hood be installed 30" (762) to 36" (914) above the countertop.
Rail option (R) wall chimney hoods come with a classic stainless steel decorative rail and stand-offs. Optional platinum or brass rails are available to match Wolf dual fuel range bezels. Contact your Wolf dealer for details.
If you are installing an optional duct cover with the pro wall chimney hood, refer to instruc­tions on page 10 before installing the hood.
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
4
I N S TA L L AT I O N I N S T R U C T I O N S
TOP WIDTH
S
UBTRACT 18" (457) FROM OVERALL WIDTH
O
VERALL WIDTH
4" (
102)
131/2"
(343)
24" (610)
OVERALL DEPTH
18" (457)
O
VERALL
H
EIGHT
2"
(51)
3
/4" (19)
DIAMETER
O
F RAIL
E
6"
(152)
5"
(127)
LOCATION OF
ELECTRICAL
30" TO 36"
(762–914)
TO COUNTERTOP
30" TO 36"
(762–914)
TO COUNTERTOP
18" (457)
HEIGHT
OF HOOD
24" (610)
DEPTH OF HOOD
WIDTH OF HOOD
NOTE: Pro wall chimney hoods have a vertical discharge.
E L E C T R I C A L R E Q U I R E M E N T S
Wolf pro wall chimney ventilation hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply through the top of the hood as shown in the installation specifications illustration below. Refer to install wiring on pages 12–13.
You must follow all national electrical code regulations. In addition, be aware of local codes and ordinances when installing your service.
OV E R A L L D I M E N S I O N S
P R O W A L L C H I M N E Y H O O D S
Overall Widths 36" (914), 42" (1067),
48" (1219), and 54" (1372)
Overall Height
Overall Depth (
excluding
rail) 24" (610)
18" (457)
Shipping Weight (shell only) 67–126 lbs
(30–57 kg)
Unit dimensions may vary to ±1/8" (3).
Pro wall chimney hood shown with (R) rail option.
I N S TA L L AT I O N S P E C I F I C A T I O N S
Dimensions in parentheses are in millimeters unless otherwise specified.
5
W O L F P R O W A L L C H I M N E Y V E N T I L A T I O N H O O D S
I N S TA L L AT I O N S P E C I F I C A T I O N S
The illustration and chart below provides dimensions specific to each pro wall chimney hood model. These dimensions are critical for proper installation.
To reduce the risk of fire and electric shock, install this ventilation hood only with a blower manufactured by Wolf.
lower model numbers are listed on
B page 17.
Pro Wall Chimney Hoods
Model (A) (B) (C) (D)
PWC362418(R) 36" (914) 18" (457) 7" (178) 9" (228)
PWC422418(R) 42" (1067) 24" (610) 7" (178) 12" (304)
PWC482418(R) 48" (1219) 30" (762) 7" (178) 15" (381)
PWC542418(R) 54" (1372) 36" (914) 7" (178) 18" (457)
Letters correspond to those in the illustrations.
6
Loading...