Wolf PW302418 Installation

I NSTALLATION I NSTRUCTIONS
P RO W ALL V ENTILATION H OODS
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
WOLF®is a registered trademark of Wolf Appliance Company, Inc.
CONTACT INFORMATION
Wolf Customer Service: 800-332-9513
Website: wolfappliance.com
3
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
This installation must be completed by a qualified installer or Wolf authorized service center technician.
Installer:
Please read the entire Installation Instructions prior to installation. Save these instructions for the local inspector’s refer­ence, then leave them with the homeowner.
Homeowner:
Please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
Any questions or problems about the installation should be directed to your Wolf dealer or Wolf Appliance Company, Inc. at 800-332-9513. You can also visit our website at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the Pro wall ventilation hood. Both numbers are listed on the rating plate, located on the left wall of the hood shell.
Model Number
Serial Number
WOLF PRO WALL VENTILATION HOODS
Low-Profile Wall Hood
Low-Profile Wall Hood (R) Rail Option
24" (610) Wall Hood
24" (610) Wall Hood (R) Rail Option
27" (686) Wall Hood
27" (686) Wall Hood (R) Rail Option
Dimensions in parentheses are in millimeters unless otherwise specified.
LIST OF MATERIALS
The following is a list of materials shipped with the Wolf Pro wall ventilation hood.
Stainless steel wall hood
Transition with backdraft damper (attached inside hood—needs to be removed)
Decorative stainless steel rail and installa­tion components—(R) model hoods only
Control knobs—two for low-profile and 24" (610) deep hoods, three for 27" (686) deep hoods
Filters and grease cups (installed in hood)
(10) #10 x 2" (51) self-tapping hex head screws
(10) 10-24 washer nuts
Installation package (taped to filters)
Installation Instructions
Use & Care Information and product registration card
Wolf logo nameplate
4
WOLF PRO WALL VENTILATION HOODS
IMPORTANT NOTE:
Wolf recommends that the Pro wall ventilation hood be installed 30" (762) to 36" (914) above the countertop.
Rail option (R) wall hoods come with a classic stainless steel decorative rail and stand-offs. Optional platinum or brass rails are available to match Wolf dual fuel range bezels. Contact your Wolf dealer for details.
ELECTRICAL REQUIREMENTS
Wolf Pro wall ventilation hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply within the shaded area shown in the Installation Specifications illustration for your specific wall hood on page 6.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
DUCT COVER
If you are installing a Wolf duct cover with the wall hood, refer to instructions on page 21 before installing the hood.
RECIRCULATING KIT
If you are installing the accessory recirculating kit, refer to the instructions included with the kit before installing the hood.
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.
INSTALLATION CONSIDERATIONS
Wolf Pro wall ventilation hoods are recommended for use with all Wolf cooking appliances.
IMPORTANT NOTE:
For optimal performance, a Pro 27" (686) deep wall hood is recom­mended for use with ranges and rangetops that contain a charbroiler or griddle.
Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Wolf Warranty. Refer to the Wolf Pro Ventilation Hoods Use & Care Information for warranty details, or visit the Contact/ Help section of our website, wolfappliance.com.
Make sure you have the tools and materials necessary for proper installation.
Warranty service must be performed by a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation.
IMPORTANT NOTE:
Wolf Pro ventilation hoods are shipped without the blower assembly. Wolf internal, in-line and remote blower assemblies are available, refer to page
20. Use only a Wolf blower with the Pro wall ventilation hood.
5
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
10" (254)
OVERALL
HEIGHT
OVERALL WIDTH
4" (102)
22" (559)
OVERALL DEPTH
12"
(305)
2"
(51)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL WIDTH
4" (102)
24" (610)
OVERALL DEPTH
12"
(305)
18" (457)
OVERALL
HEIGHT
2"
(51)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL WIDTH
27" (686)
OVERALL DEPTH
12"
(305)
18" (457)
OVERALL
HEIGHT
2"
(51)
4" (102)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL DIMENSIONS
LOW-PROFILE WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067) and 48" (1219)
Overall Height
10" (254)
Overall Depth (
excluding
rail) 22" (559)
Shipping Weight (shell only) 39–55 lbs
(18–25 kg)
Dimensions may vary to ±1/8" (3).
24" (610) DEEP WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067), 48" (1219), 54" (1372),
60" (1524) and 66" (1676)
Overall Height
18" (457)
Overall Depth (
excluding
rail) 24" (610)
Shipping Weight (shell only) 67–126 lbs
(30–57 kg)
Dimensions may vary to ±1/8" (3).
27" (686) DEEP WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067), 48" (1219), 54" (1372),
60" (1524) and 66" (1676)
Overall Height
18" (457)
Overall Depth (
excluding
rail) 27" (686)
Shipping Weight (shell only) 69–128 lbs
(31–58 kg)
Dimensions may vary to ±1/8" (3).
Low Profile Wall Hood
shown with (R) rail option
24" (610) Deep Wall Hood
shown with (R) rail option
27" (686) Deep Wall Hood
shown with (R) rail option
6
WOLF PRO WALL VENTILATION HOODS
30" TO 36"
(762–914)
TO COUNTERTOP
30" TO 36"
(762–914)
TO COUNTERTOP
10" (254) 18" (457)
HEIGHT
OF HOOD
22" (559) 24" (610)
DEPTH OF HOOD
WIDTH OF HOOD
NOTE: Low-profile and 24" (610) deep wall hoods have a vertical or horizontal discharge; discharge direction varies with blower model.
E
6"
(152)
5"
(127)
LOCATION OF ELECTRICAL
30" TO 36"
(762–914)
TO COUNTERTOP
30" TO 36"
(762–914)
TO COUNTERTOP
18" (457)
HEIGHT
OF HOOD
27" (686)
DEPTH OF HOOD
WIDTH OF HOOD
E
6"
(152)
5"
(127)
LOCATION OF ELECTRICAL
NOTE: 27" (686) deep wall hoods are vertical discharge only.
INSTALLATION SPECIFICATIONS
Low-Profile and 24" (610) Deep Wall Hoods
27" (686) Deep Wall Hoods
7
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
INSTALLATION SPECIFICATIONS
The following chart provides dimensions specific to each wall hood model. These dimensions are critical for proper installation. Also refer to the illustration below.
Low-Profile Wall Hoods
Model (A) (B) (C) (D)
W302210I 30" (762) 71/2" (191) 15" (381) 411/16" (119)
W362210I 36" (914) 71/2" (191) 18" (457) 411/16" (119)
W362210 36" (914) 71/2" (191) 18" (457) 411/16" (119)
W422210 42" (1067) 71/2" (191) 21" (533) 411/16" (119)
W482210 48" (1219) 71/2" (191) 24" (610) 411/16" (119)
24" (610) Deep Wall Hoods
Model (A) (B) (C) (D)
W302418 30" (762) 91/2" (241) 15" (381) 513/16" (148)
W362418 36" (914) 91/2" (241) 18" (457) 513/16" (148)
W422418 42" (1067) 91/2" (241) 21" (533) 513/16" (148)
W482418 48" (1219) 91/2" (241) 24" (610) 513/16" (148)
W542418 54" (1372) 91/2" (241) 27" (686) 513/16" (148)
W602418 60" (1524) 91/2" (241) 30" (762) 513/16" (148)
W662418 66" (1676) 91/2" (241) 33" (838) 513/16" (148)
27" (686) Deep Wall Hoods
Model (A) (B) (C) (D)
W302718 30" (762) 91/2" (241) 15" (381) 513/16" (148)
W362718 36" (914) 91/2" (241) 18" (457) 513/16" (148)
W422718 42" (1067) 91/2" (241) 21" (533) 513/16" (148)
W482718 48" (1219) 91/2" (241) 24" (610) 513/16" (148)
W542718 54" (1372) 91/2" (241) 27" (686) 513/16" (148)
W602718 60" (1524) 91/2" (241) 30" (762) 513/16" (148)
W662718 66" (1676) 91/2" (241) 33" (838) 513/16" (148)
Letters correspond to those in the illustration.
B
HEIGHT OF
TRANSITION
TO CENTER
OF TRANSITION
D
C
TO CENTER
OF TRANSITION
A
WIDTH
OF HOOD
8
LOW-PROFILE AND 24" (610) HOODS
STEP 1: INSTALL DUCTWORK
IMPORTANT NOTE:
Wolf recommends that the Pro wall ventilation hood be installed 30" (762) to 36" (914) above the countertop.
IMPORTANT NOTE:
Consult a qualified HVAC Engineer for specific ducting applications.
IMPORTANT NOTE:
All Wolf Pro wall hoods must exhaust to the outdoors except when used with the accessory recirculating kit. Always use metal ducting. Do not use flex ducting.
Decide where the ductwork will run between the hood and the outside. A straight, short duct run will allow the hood to perform more efficiently. Limit the number of elbows and transitions to as few as possible. Long duct runs, elbows and transitions will reduce the performance of the hood. Wolf recommends the maximum linear duct run be no greater than 50' (15 m). The low-profile and 24" (610) deep wall hoods have an adjustable discharge that can run vertically or horizontally.
Horizontal discharge is only applicable on low-profile wall hoods (excluding W302210I and W362210I) used with a remote blower. In-line blowers and WBLOWER-60INT are not for use in horizontal discharge applications with a low-profile wall hood.
Horizontal discharge is applicable on 24" (610) deep wall hoods used with WBLOWER-60INT, WBLOWER-120INT or any Wolf remote blower. In-line blowers and WBLOWER-90INT are not for use in horizontal discharge applications.
IMPORTANT NOTE:
There is a possibility of noise issues if there is a short duct run coupled with a remote blower.
To reduce the risk of fire, use only metal ductwork.
WOLF PRO WALL VENTILATION HOODS
DUCTWORK INSTALLATION
THROUGH ROOF
22" (559)
DEPTH OF HOOD
8" ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
REMOTE BLOWER
*HORIZONTAL DISCHARGE APPLICABLE ON LOW-PROFILE WALL HOODS
(EXCLUDING W302210I AND W362210I) USING A REMOTE BLOWER. LOW-PROFILE WALL
HOODS WITH AN INTERNAL OR IN-LINE BLOWER MUST USE VERTICAL DISCHARGE.
DUCTWORK INSTALLATION
THROUGH WALL
DISCHARGE COLLAR
HORIZONTAL DISCHARGE*
VERTICAL DISCHARGE
TRANSITION
17
3
/4"W x 41/4"D TO 8" ROUND
9
3
/8"H (INCLUDING FLANGES)
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
10" (254)
HEIGHT OF HOOD
WALL HOOD
ROOF CAP OR REMOTE BLOWER –
TRANSITION FROM 8" (203) TO 10" (254) DUCT
REQUIRED FOR REMOTE BLOWER
Ducting options for low-profile wall hoods
Loading...