INSTALLATION GUIDE
Pro Ventilation Hood Liners
Contents
Important Note
Wolf Pro Hood Liners. . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 4
Pro Hood Liner Specifications . . . . . . . . . . . . . . . . . . . 5
Pro Hood Liner Installation . . . . . . . . . . . . . . . . . . . . . . 7
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Features and specifications are subject to change at any time
without notice. Visit wolfappliance.com/specs for the most
up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient use of Wolf equipment,
T
please take note of the following types of highlighted
information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION signals a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
Wolf Pro Hood Liners 3
wolfappliance.com/specs
Pro Hood Liner Installation
IMPORTANT NOTE: T
his installation must be completed
by a qualified installer or Wolf factory certified service.
Read this entire installation guide and blower installation
instructions prior to installation and save for the local
inspector’s reference. The homeowner should keep this
installation guide for future reference.
This appliance must be installed in accordance with
National Electrical Codes, as well as all state, municipal
and local codes. The correct voltage, frequency and
amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly
sized circuit breaker or time delay fuse. The proper
voltage, frequency and amperage ratings are listed on the
product rating plate.
Record the model and serial numbers before installing the
hood liner. Both numbers are listed on the product rating
plate, located inside the left wall of the hood liner shell.
Refer to the illustration below.
olf Pro Hood Liner
W
Model Number
Serial Number
RATING PLATE
Location of rating plate
(inside hood).
Installation Considerations 4
IMPORTANT INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY, OBSERVE THE FOLLOWING:
•
Installation work and electrical wiring must be
done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated
construction.
•
Two installers are recommended due to the size and
weight of the pro hood liner.
•
Install the pro hood liner only with a blower manufactured by Wolf.
•
When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
•
Ducted fans must always be vented to the outdoors.
To reduce the risk of fire and properly exhaust air,
be certain to duct air outside. Do not vent exhaust
air into spaces within walls or ceilings or into attics,
crawl spaces or garages.
Installation Considerations
olf pro hood liners are recommended for use with all
W
Wolf cooking appliances.
• Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Wolf warranty. Refer to the Wolf pro
ventilation hoods use & care guide for warranty details,
or visit the contact & support section of our website,
wolfappliance.com.
• Warranty service must be performed by Wolf factory
certified service. Wolf is not responsible for service
required to correct a faulty installation.
DECORATIVE HOODS
The bottom edge of the decorative hood can not extend
below the hood liner. The bottom
is stainless steel. The remaining reveal is galvanized metal.
Verify the decorative hood does not extend beyond
(19) to ensure the most visually appealing installation.
BLOWER ASSEMBLIES
Wolf pro hood liners are shipped without a blower
assembly. Internal, in-line and remote blowers are available through your authorized Wolf dealer. For local dealer
information, visit the find a showroom section of our
website, wolfappliance.com.
3
/4" (19) of the hood liner
3
/4"
Blower size is dependant on the size of the cooking
surface, volume of air being moved and length of the duct
run. Refer to ventilation recommendations in the Wolf
design guide.
In-line and remote blowers require a Romex
provided) from the blower to the ventilation hood.
For blower installation, refer to specific instructions
provided with each blower. Additional information can also
be found on our website, wolfappliance.com.
®
(not