o ensure the safe and efficient use of Wolf equipment,
T please take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially important.
CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or death if precautions are not followed.
Wolf Pro Hood Liners 3
wolfappliance.com/specs
Pro Hood Liner Installation
IMPORTANT NOTE: T
his installation must be completed
by a qualified installer or Wolf factory certified service.
Read this entire installation guide and blower installation instructions prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference.
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedi­cated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the hood liner. Both numbers are listed on the product rating plate, located inside the left wall of the hood liner shell. Refer to the illustration below.
olf Pro Hood Liner
W
Model Number
Serial Number
RATING PLATE
Location of rating plate (inside hood).
Installation Considerations 4
IMPORTANT INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Two installers are recommended due to the size and weight of the pro hood liner.
Install the pro hood liner only with a blower manufac­tured by Wolf.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
To reduce the risk of fire and properly exhaust air, be certain to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
Installation Considerations
olf pro hood liners are recommended for use with all
W Wolf cooking appliances.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Wolf warranty. Refer to the Wolf pro ventilation hoods use & care guide for warranty details, or visit the contact & support section of our website, wolfappliance.com.
Warranty service must be performed by Wolf factory
certified service. Wolf is not responsible for service required to correct a faulty installation.
DECORATIVE HOODS
The bottom edge of the decorative hood can not extend below the hood liner. The bottom is stainless steel. The remaining reveal is galvanized metal. Verify the decorative hood does not extend beyond
(19) to ensure the most visually appealing installation.
BLOWER ASSEMBLIES
Wolf pro hood liners are shipped without a blower assembly. Internal, in-line and remote blowers are avail­able through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
3
/4" (19) of the hood liner
3
/4"
Blower size is dependant on the size of the cooking surface, volume of air being moved and length of the duct run. Refer to ventilation recommendations in the Wolf design guide.
In-line and remote blowers require a Romex provided) from the blower to the ventilation hood.
For blower installation, refer to specific instructions provided with each blower. Additional information can also be found on our website, wolfappliance.com.
®