Wolf ICBCT30E, ICBCT36EU, ICBCT30EU, ICBCT36E, ICBCT15E User Manual

ELECTRIC COOKTOPS
INSTALLATION INSTRUCTIONS
INSTRUCCIONES DE INSTALACIÓN
INSTRUCTIONS D’INSTALLATION
ISTRUZIONI PER L’INSTALLAZIONE
INSTALLATIONSANWEISUNGEN
3
ESPÃNOL 22
FRANÇAIS 40
ITALIANO 58
DEUTSCH 76
As you follow these instruc tions, you will notice WARNING and CAUTION symbols. This blocked information is impor tant for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights informa­tion that is especially relevant to a problem­free installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
WOLF®is a registered trademark of Wolf Appliance, Inc.
CONTACT INFORMATION
Website: wolfappliance.com
5
WOLF ELECTRIC COOKTOPS
BEFORE YOU START
Proper installation is your responsibility. Have a qualified technician install this cooktop. You must also assure that electri­cal installation is adequate and in compli­ance with all local codes and ordinances.
Installations and repairs must be performed by a qualified or licensed contractor or electrician qualified or licensed by the state, province, or region where this appliance is being installed.
Make sure you have everything necessary for correct installation. It is the responsibil­ity of the installer to comply with the installation clearances specified in this book and on the product rating plate. The rating plate is located on the underside of the cooktop. Refer to the illustration below.
Electrical ground is required; see Electrical Requirements on page 16.
This cooktop is intended for indoor use.
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation Instruc­tions prior to installation.
This installation must be completed by a qualified technician.
Installer:
please retain these instructions for local inspector’s reference, then leave them with the homeowner.
Homeowner:
please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
IMPORTANT NOTE:
This appliance must be installed in accordance local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and power ratings are listed on the product rating plate.
Record the model and serial numbers before installing the cooktop. Both numbers are on the rating plate, located on the underside of the cooktop. Refer to the illustration below.
RATING PLATE INFORMATION
Model Number
Serial Number
Rating plate location
Location of rating
plate under cooktop
6
WOLF ELECTRIC COOKTOPS
LOCATION IN COUNTERTOP
A)
Minimum flat countertop surface. Must be equal to or greater than cooktop width.
B)
Minimum 25 mm wide clearance from the cooktop side edge to any combustible surface up to 457 mm above the cooktop (noted by shaded area).
OVERHEAD CABINET DIMENSIONS
C)
Minimum spacing between overhead side cabinets must be greater than or equal to the nominal width of the cooktop unit(s).
D)
Minimum 457 mm vertical distance from the countertop to the bottom of side cabinets within minimum side clearance.
E)
Minimum vertical distance between the countertop and combustible materials above the cooktop must be 762 mm.
F)
Minimum 25 mm from rear wall.
G)
Maximum 330 mm depth of overhead and side cabinets directly above and within side clearance.
Failure to locate the cooktop unit without the proper clearances will result in a fire hazard.
C
G
D
A
B
B
E
F
Minimum clearances for installation
SITE PREPARATION
IMPORTANT NOTE:
Installation of the Wolf electric cooktop must meet the following location requirements. All dimensions listed are minimum requirements for safe operation. Refer to the illustration below.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a ventilation hood that projects horizontally a minimum of 127 mm beyond the bottom cabinets.
7
INSTALLATION INSTRUCTIONS
INSTALLATION SPECIFICATIONS
The illustrations on pages 8–13 provide the overall dimensions, installation specifications and countertop cut-out for each of the Wolf electric cooktop models.
These cooktops are designed to fit a standard 610 mm deep base cabinet with a 635 mm deep countertop. Before making the counter­top cut-out, verify that the cooktop will clear the side walls of the base cabinet below.
Clearance is required for the terminal block and conduit located at the right rear of the cooktop. Refer to the illustration below for dimensions.
FRAMED ELECTRIC COOKTOPS
For framed models, a minimum 146 mm clearance is required between the countertop and any combustible surface directly below the cooktop.
Wolf framed electric cooktops are designed to be installed in combination with other cooktop units.
IMPORTANT NOTE:
When multiple cooktop units are installed side by side, refer to the countertop cut-out dimensions on page 11.
Wolf framed electric cooktops can accommo­date a Wolf downdraft ventilation system. Refer to installation instructions provided with the downdraft for additional specifications.
56 mm
84 mm
24 mm
22 mm
32 mm
Terminal block dimensions
UNFRAMED ELECTRIC COOKTOPS
For unframed models, a minimum 159 mm clearance is required between the countertop and any combustible surface directly below the cooktop.
IMPORTANT NOTE:
Unframed electric cooktops are not designed to be installed in combination with other cooktops.
IMPORTANT NOTE:
Unframed electric cooktops cannot be installed with a downdraft ventilation system.
For installation options of the unframed electric cooktops, refer to Unframed Installa­tions on pages 14–15.
8
Overall Dimensions
Countertop Cut-Out
MODEL ICBCT15E
Overall Width 381 mm
Overall Height 96 mm
Overall Depth 533 mm
Minimum Cabinet Depth 578 mm
Minimum Height Clearance*
102 mm
Cut-Out Width 340 mm
Cut-Out Depth 489 mm
INSTALLATION SPECIFICATIONS – MODEL ICBCT15E
FRAMED MODEL ICBCT15E
The illustrations below provide installation specifications for Model ICBCT15E.
If Model ICBCT15E is installed above cabinets, the electrical placement is not critical. A grounded electrical box should be located within 1.2 m of the right rear of the cooktop.
For installation above an oven, unless you are using cabinets deeper than 610 mm, it is recommended that the electrical supply be placed in the base cabinet to the right of the oven.
WOLF
ELECTRIC COOKTOPS
IMPORTANT NOTE:
Do not block the cooling
fan located at the bottom of the cooktop.
*Minimum 146 mm clearance is required
between countertop and any combustible surface directly below the cooktop.
For detailed terminal block dimensions, refer to the illustration on page 7.
Dimensions may vary to ±3 mm.
533 mm
OVERALL
DEPTH
381 mm
96 mm
OVERALL WIDTH
127 mm
TERMINAL BOX
330 mm
max
51**
489 mm
mm
COOKTOP CUT-OUT
DEPTH
64 mm
min
457 mm
838 mm
51 mm*
min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
RECOMMENDED
CABINET WIDTH
340 mm
COOKTOP CUT-OUT
WIDTH
102 mm
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
E
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
NOTE: Application shown allows for installation of two 381 mm modules side-by-side with 838 mm recommended cabinet width. 457 mm recommended cabinet width for installation of single 381 mm cooktop or module. *Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
381 mm
340 mm
COOKTOP CUT-OUT
WIDTH
381 mm
489 mm
64 mm
min
FRONT OF COUNTERTOP
COOKTOP
CUT-OUT DEPTH
9
Overall Dimensions
Countertop Cut-Out
533 mm
OVERALL
DEPTH
762 mm
OVERALL WIDTH
127 mm
96 mm
TERMINAL BOX
FRAMED MODEL ICBCT30E
The illustrations below provide installation specifications for Model ICBCT30E.
For ease of installation, 838 mm cabinets are recommended for installation of Model ICBCT30E.
A Wolf 762 mm or 914 mm built-in single oven may be installed below Model ICBCT30E. For this installation, unless you are using cabinets deeper than 610 mm, it is recommended that the electrical supply be placed in the base cabinet to the right of the oven.
Refer to installation instructions provided with the built-in oven for additional specifications.
If Model ICBCT30E is installed above cabinets, the electrical placement is not critical. A grounded electrical box should be located within 1.2 m of the right rear of the cooktop.
IMPORTANT NOTE:
Do not block the cooling fan located at the bottom of the cooktop.
MODEL ICBCT30E
Overall Width 762 mm
Overall Height 96 mm
Overall Depth 533 mm
Minimum Cabinet Depth 578 mm
Minimum Height Clearance*
102 mm
Cut-Out Width 721 mm
Cut-Out Depth 489 mm
INSTALLATION SPECIFICATIONS – MODEL ICBCT30E
INSTALLATION
INSTRUCTIONS
*Minimum 146 mm clearance is required
between countertop and any combustible surface directly below the cooktop.
For detailed terminal block dimensions, refer to the illustration on page 7.
Dimensions may vary to ±3 mm.
330 mm
max
489 mm
51**
mm
COOKTOP CUT-OUT
DEPTH
610 mm min
457 mm
64 mm
min
914 mm
STANDARD FLOOR TO
COUNTERTOP
HEIGHT
838 mm
RECOMMENDED
51 mm*min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
CABINET WIDTH
762 mm min
721 mm COOKTOP
CUT-OUT WIDTH
102 mm
95 mm
89 mm
min
762 mm OVEN OPENING
254 mm
E
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
721 mm
COOKTOP CUT-OUT WIDTH
489 mm
64 mm
min
FRONT OF COUNTERTOP
COOKTOP
CUT-OUT DEPTH
10
WOLF ELECTRIC COOKTOPS
FRAMED MODEL ICBCT36E
The illustrations below provide installation specifications for Model ICBCT36E.
For ease of installation, 991 mm cabinets are recommended for installation of Model ICBCT36E.
A Wolf 762 mm or 914 mm built-in single oven may be installed below Model ICBCT36E. For this installation, unless you are using cabinets deeper than 610 mm, it is recommended that the electrical supply be placed in the base cabinet to the right of the oven.
Refer to installation instructions provided with the built-in oven for additional specifications.
If Model ICBCT36E is installed above cabinets, the electrical placement is not critical. A grounded electrical box should be located within 1.2 m of the right rear of the cooktop.
IMPORTANT NOTE:
Do not block the cooling
fan located at the bottom of the cooktop.
Overall Dimensions
Countertop Cut-Out
MODEL ICBCT36E
Overall Width 914 mm
Overall Height 96 mm
Overall Depth 533 mm
Minimum Cabinet Depth 578 mm
Minimum Height Clearance*
102 mm
Cut-Out Width 873 mm
Cut-Out Depth 489 mm
INSTALLATION SPECIFICATIONS – MODEL ICBCT36E
*Minimum 146 mm clearance is required
between countertop and any combustible surface directly below the cooktop.
For detailed terminal block dimensions, refer to the illustration on page 7.
Dimensions may vary to ±3 mm.
533 mm
OVERALL
DEPTH
914 mm
96 mm
OVERALL WIDTH
127 mm
TERMINAL BOX
330 mm
max
489 mm
51**
mm
COOKTOP CUT-OUT
DEPTH
610 mm min
457 mm
64 mm
min
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
51 mm*min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
RECOMMENDED CABINET WIDTH
991 mm
914 mm min
873 mm
COOKTOP CUT-OUT WIDTH
102 mm
95 mm
min
914 mm OVEN OPENING
89 mm
254 mm
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
E
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
873 mm
COOKTOP CUT-OUT WIDTH
489 mm
64 mm
min
FRONT OF COUNTERTOP
COOKTOP
CUT-OUT DEPTH
11
INSTALLATION INSTRUCTIONS
MULTIPLE COOKTOP
INSTALLATION
If the framed electric cooktop is to be used with any combination of additional cooktop units or modules with a filler strip, the cut-out width is calculated by adding the correspon­ding units' cut-out dimensions plus 32 mm for each additional unit. Refer to the illustration below.
IMPORTANT NOTE:
For Model ICBCT15E, the cut-out width should be increased from 340 mm to 356 mm when installed with multiple units.
IMPORTANT NOTE:
Unframed electric cooktops Models ICBCT30EU and ICBCT36EU are not designed to be installed in combination with other cooktop units.
IMPORTANT NOTE:
When multiple units are installed side by side, each unit must have its own separate recommended electrical circuit.
Countertop cut-out dimensions for installation of multiple cooktops
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit our website, wolfappliance.com.
When two or more modules are installed together, an integrated module filler strip (IFILLER/S) is recommended. If a 762 mm downdraft ventilation system is also installed, an integrated module support for downdraft ventilation (ISUPPORT) is also required. Contact your Wolf dealer for information on these accessory components.
1518 mm – FOUR MODULES WIDTH OR
1511 mm – 762 mm COOKTOP AND TWO MODULES OR
1276 mm – 914 mm COOKTOP AND ONE MODULE
1130 mm – THREE MODULES WIDTH OR
1124 mm – 762 mm COOKTOP AND ONE MODULE
743 mm
TWO MODULES WIDTH
356 mm
CUT-OUT
64 mm
min
WIDTH
FRONT OF COUNTERTOP
489 mm
CUT-OUT
DEPTH
12
51 mm*min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
457 mm
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
762 mm OVEN OPENING
838 mm
RECOMMENDED
CABINET WIDTH
762 mm min
721 mm COOKTOP
CUT-OUT WIDTH
33 mm
RADIUS
62 mm
492 mm
COOKTOP
CUT-OUT DEPTH
11 mm RADIUS
765 mm**
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
FRONT OF COUNTERTOP
40 mm
537 mm**
RECESSED AREA FOR FLUSH MOUNT INSTALLATION ONLY
**Minimum dimension, but may be exceeded by up to 3 mm.
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
8 mm
22 mm
max
COUNTERTOP
PROFILE
330 mm
max
610 mm min
102 mm min
SEE COUNTERTOP
CUT-OUT BELOW
SEE COUNTERTOP
CUT-OUT BELOW
*Minimum clearance from both side edges and back edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
51 mm*
E
254 mm
102 mm
min TO OVEN OPENING
89 mm
114 mm
Overall Dimensions
Countertop Cut-Out
UNFRAMED MODEL ICBCT30EU
The illustrations below provide installation specifications for Model ICBCT30EU.
For ease of installation, 838 mm cabinets are recommended for installation of Model ICBCT30EU.
A Wolf 762 mm built-in single oven may be installed below Model ICBCT30EU. For this installation, unless you are using cabinets deeper than 610 mm, it is recommended that the electrical supply be placed in the base cabinet to the right of the oven. Refer to instal­lation instructions provided with the built-in oven for additional specifications.
If Model ICBCT30EU is installed above cabinets, electrical placement is not critical. A grounded electrical box should be located within 1.2 m of the right rear of the cooktop.
For Model ICBCT30EU installation options, refer to Unframed Installations on pages 14–15.
IMPORTANT NOTE:
For flush mount applica­tions, it is recommended to measure the cooktop glass before cutting the countertop to ensure a proper fit. Small variances may exist between the template and the cooktop.
MODEL ICBCT30EU
Overall Width 762 mm
Overall Height 108 mm
Overall Depth 533 mm
Minimum Cabinet Depth 578 mm
Minimum Height Clearance*
114 mm
Cut-Out Width 721 mm
Cut-Out Depth 492 mm
INSTALLATION SPECIFICATIONS – MODEL ICBCT30EU
WOLF ELECTRIC COOKTOPS
*Minimum 159 mm clearance is required
between countertop and any combustible surface directly below the cooktop.
For detailed terminal block dimensions, refer to the illustration on page 7.
Dimensions may vary to ±3 mm.
533 mm
OVERALL
DEPTH
762 mm
OVERALL WIDTH
108 mm
TERMINAL BOX
140 mm
13
INSTALLATION INSTRUCTIONS
UNFRAMED MODEL ICBCT36EU
The illustrations below provide installation specifications for Model ICBCT36EU.
For ease of installation, 991 mm cabinets are recommended for installation of Model ICBCT36EU.
A Wolf 914 mm built-in single oven may be installed below Model ICBCT36EU. For this installation, unless you are using cabinets deeper than 610 mm, it is recommended that the electrical supply be placed in the base cabinet to the right of the oven. Refer to instal­lation instructions provided with the built-in oven for additional specifications.
If Model ICBCT36EU is installed above cabinets, electrical placement is not critical. A grounded electrical box should be located within 1.2 m of the right rear of the cooktop.
For Model ICBCT36EU installation options, refer to Unframed Installations on pages 14–15.
IMPORTANT NOTE:
For flush mount applica­tions, it is recommended to measure the cooktop glass before cutting the countertop to ensure a proper fit. Small variances may exist between the template and the cooktop.
51 mm*min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
457 mm
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
*Minimum clearance from both side edges and back edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
991 mm
RECOMMENDED CABINET WIDTH
914 mm min
914 mm OVEN OPENING
918 mm**
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
873 mm
COOKTOP CUT-OUT WIDTH
33 mm
RADIUS
FRONT OF COUNTERTOP
62 mm
492 mm
COOKTOP
CUT-OUT DEPTH
40 mm
537 mm**
RECESSED AREA FOR FLUSH MOUNT INSTALLATION ONLY
11 mm RADIUS
**Minimum dimension, but may be exceeded by up to 3 mm.
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
8 mm
22 mm
max
COUNTERTOP
PROFILE
SEE COUNTERTOP
CUT-OUT BELOW
330 mm
max
610 mm min
SEE COUNTERTOP
CUT-OUT BELOW
51 mm*
102 mm
min
E
254 mm
102 mm
min
TO OVEN
OPENING
89 mm
114 mm
Overall Dimensions
Countertop Cut-Out
MODEL ICBCT36EU
Overall Width 914 mm
Overall Height 108 mm
Overall Depth 533 mm
Minimum Cabinet Depth 578 mm
Minimum Height Clearance*
114 mm
Cut-Out Width 873 mm
Cut-Out Depth 492 mm
INSTALLATION SPECIFICATIONS – MODEL ICBCT36EU
*Minimum 159 mm clearance is required
between countertop and any combustible surface directly below the cooktop.
For detailed terminal block dimensions, refer to the illustration on page 7.
Dimensions may vary to ±3 mm.
533 mm
OVERALL
DEPTH
914 mm
OVERALL WIDTH
108 mm
TERMINAL BOX
140 mm
14
WOLF ELECTRIC COOKTOPS
UNFRAMED INSTALLATIONS
MODELS ICBCT30EU AND ICBCT36EU
Unframed electric cooktop Models ICBCT30EU and ICBCT36EU can be mounted flush with the top of the countertop or as a frameless instal­lation with the glass mounted on top of the countertop surface.
IMPORTANT NOTE:
The materials required for a flush mount installation are provided with the unframed Models ICBCT30EU and ICBCT36EU. Refer to the instructions provided with the unframed cooktop installation kit (#811358) for additional specifications.
FLUSH MOUNT INSTALLATION
There are two options for a flush mount installation of the unframed electric cooktop; Option 1 and Option 2.
OPTION 1:
For this flush mount installation, a recessed area surrounding the standard coun­tertop cut-out is required. Fabrication of the recessed area must take place before the final countertop installation. A template of the coun­tertop cut-out is provided with the unframed cooktop for fabrication purposes.
IMPORTANT NOTE:
This fabrication method is not recommended for molded backsplash style countertops (triple cove).
For countertop cut-out dimensions, refer to the Installation Specifications illustration on page 12 for Model ICBCT30EU and page 13 for Model ICBCT36EU.
In order to rout the required recessed area for this flush mount installation, a second template must be made from 13 mm plywood. The template will be used as a guide for a top bearing router bit.
Make the wood template wide enough so that clamps used to hold this template to the coun­tertop do not interfere with the router base. The cut-out dimension of the wood template should match the outer perimeter of the template supplied with the cooktop.
Center the wood template over the existing cut-out in the countertop and clamp. It may be helpful to use medium-strength double-sided tape to adhere the template to the countertop; this will keep the template from shifting during the routing operation. Make sure that the adhesive can be easily removed by testing it on a scrap piece of the countertop. Using a top bearing router bit with the wood template as a guide, rout out a 8 mm deep recessed area in the countertop cut-out.
Flush mount installations are intended for granite, solid surface or stone coun­tertop surfaces only. Failure to use high heat resistant surface will result in coun­tertop damage if hot cooking utensils are accidentally moved off the cooking surface.
15
INSTALLATION INSTRUCTIONS
FRAMELESS INSTALLATION
Unframed electric cooktop Models ICBCT30EU and ICBCT36EU can be installed as a frameless application, with the glass mounted on top of the countertop surface. For countertop cut-out dimensions, refer to the Installation Specifica­tions illustration on page 12 for Model ICBCT30EU and page 13 for Model ICBCT36EU.
UNFRAMED INSTALLATIONS
FLUSH MOUNT INSTALLATION
OPTION 2:
For this flush mount installation, the countertop cut-out will be the same size as the outer edge of the glass top. It is recom­mended that cooktop itself be used as the template for the cut-out. Turn the cooktop over and mark the opening using the glass top as a template.
It will be necessary to attach L-shaped brackets or cleats to the inner perimeter of the cut-out to support the cooktop. The top edge of the bracket can be no wider than 22 mm and will be attached 8 mm below the surface of the countertop. Refer to the illustration below. Attachment of the brackets is up to the installer's discretion, wherever enough coun­tertop material is present.
For additional support in the cut-out area, adhere scrap countertop material to the bottom side of the countertop. Consult your countertop supplier for the proper methods of attachment.
Flush mount installation brackets
8 mm
22 mm
L-Shaped
Brackets
16
WOLF ELECTRIC COOKTOPS
ELECTRICAL REQUIREMENTS
REQUIRED POWER SUPPLY
Model ICBCT15E
220-240 V AC, 50/60 Hz
Models ICBCT30E and ICBCT30EU
220-240 V AC, 50/60 Hz
Models ICBCT36E and ICBCT36EU
220-240 V AC, 50/60 Hz
MAXIMUM CONNECTED LOAD
Model ICBCT15E
3.7 kW
Models ICBCT30E and ICBCT30EU
8.1 kW
Models ICBCT36E and ICBCT36EU
10.5 kW
Verify that power is disconnected from the electrical box before proceeding.
This appliance must be installed in accordance with local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency and power ratings are listed on the product rating plate, located on the underside of the cooktop. Refer to the illustra­tion on page 5 for location of the rating plate.
17
INSTALLATION INSTRUCTIONS
ELECTRICAL REQUIREMENTS
A properly rated cord should be attached to the power supply of the electric cooktop as shown in the illustration below. Open the power box to expose the screws with corre­sponding numbers. Loosen the 1, 5, and ground screws. Run the cord through the circular hole and into the supply box. Attach the Neutral wire to the number 1 position. Attach the line wire to the number 5 position and attach the ground wire to the correspon­ding ground screw. After tightening the screws, tighten the cord strain relief then close the cover to the power supply box without pinching any of the wires.
The complete appliance must be properly grounded at all times when electrical power is applied.
Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must be utilized.
If aluminum house supply wiring is utilized, splice the appliance copper wire to the aluminum house wiring using special connectors designed and agency certified for joining copper and aluminum. Follow the connector manu­facturer's recommended procedure care­fully. Improper connection can result in a fire hazard!
IMPORTANT NOTE
This appliance must be installed in accordance with local codes.
Wiring diagram
N
L1
GROUND
18
COOKTOP INSTALLATION
Attach the foam strip to the underside of the cooktop frame. Refer to the illustration below.
IMPORTANT NOTE:
For frameless installa­tions, adhere the foam strip to the outer edge of the glass, not the support frame.
IMPORTANT NOTE:
The materials required for a flush mount installation are provided with the unframed Models ICBCT30EU and ICBCT36EU. Refer to the instructions provided with the unframed cooktop installation kit (#811358).
Gently lower the unit into the cut-out area in the countertop and center. Check that the front edge of cooktop is parallel to the front edge of the countertop. Check that all required clear­ances are met.
Attach the brackets to the bottom of the unit, as shown in the illustration below. Install the clamping screws into the bracket and tighten until the screws contact the underside of the countertop.
Do not overtighten the screws.
IMPORTANT NOTE:
Do not seal the cooktop to the countertop. It must be removed if service is necessary.
COOKTOP
FOAM STRIP
COOKTOP
COUNTERTOP
BRACKET
SCREWS
BRACKET
102 mm
CLAMPING
SCREW
Foam strip Installation brackets
If the ceramic glass top of the cooktop is broken, turn off power to the unit. Do not operate until glass has been replaced by a Wolf authorized service center.
WOLF ELECTRIC COOKTOPS
19
BEFORE OPERATING THE COOKTOP
Clean the ceramic glass surface carefully using the Cooktop Cleaning Crème provided with the cooktop. Remove all cleaning residue.
Read the entire Wolf Electric Cooktops Use & Care Information included with the cooktop.
COOKTOP
REMOVAL
IMPORTANT NOTE:
This procedure should only be performed by a Wolf authorized service center.
If it is necessary to remove the cooktop for cleaning or service, disconnect the electrical supply. Remove the mounting brackets on the right and left side of the unit and remove the cooktop. Reinstall in the reverse order.
IMPORTANT NOTE:
For flush mount installa­tions, use a razor blade to carefully cut around the RTV perimeter seal. A new RTV installation kit (#811358) will be required to reinstall the cooktop. This kit is available through your Wolf dealer. To obtain local dealer information, visit our website, wolfappliance.com.
INSTALLATION INSTRUCTIONS
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit our website, wolfappliance.com.
20
This cooktop must be repaired only by a Wolf authorized service center. The unit must be disconnected from power prior to service.
WOLF ELECTRIC COOKTOPS
TROUBLESHOOTING
IF COOKTOP DOES NOT OPERATE
IMPORTANT NOTE:
If the electric cooktop does not operate properly, follow these troubleshooting steps:
Verify that power is being supplied to the cooktop.
Check electrical connections to ensure that the installation has been completed correctly.
Follow troubleshooting procedures as described in the Wolf Electric Cooktops Use & Care Information.
If the cooktop still does not work, contact a Wolf authorized service center. Do not attempt to repair the cooktop yourself. Wolf is not responsible for service required to correct a faulty installation.
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit our website, wolfappliance.com.
21
IF YOU NEED SERVICE
If service is necessary, maintain the quality built into your electric cooktop by calling a Wolf authorized service center.
To obtain the name and number of a Wolf authorized service center, visit our website,
wolfappliance.com
.
When calling for service, you will need the cooktop model and serial numbers. Both numbers are listed on the rating plate, located on the underside of the cooktop. Refer to the illustration on page 5 for location of the rating plate.
The information and images in this book are the copyright property of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc.
©Wolf Appliance, Inc. all rights reserved.
CONTACT INFORMATION
Website: wolfappliance.com
INSTALLATION INSTRUCTIONS
Cuando consulte las instrucciones que aparecen en esta guía, encontrará símbolos de ADVERTENCIA y PRECAUCIÓN. Esta información en recuadros es importante para instalar el equipo de Wolf de forma segura y eficaz. Existen dos tipos de posibles riesgos que pueden producirse durante una instalación.
Otro tipo de anotación que es importante resaltar es la que se incluye en NOTA IMPORTANTE: En esta nota se resalta la información que resulta especial­mente importante para que la instalación se realice sin problemas.
indica una situación en la que se pueden sufrir heridas leves o provocar daños secundarios al producto si no se siguen las instrucciones.
indica peligro de que se produzcan heridas personales graves o incluso puede provocar la muerte si no se siguen las precauciones especificadas.
WOLF®es una marca comercial registrada de Wolf Appliance, Inc.
INFORMACIÓN DE CONTACTO
Página Web: wolfappliance.com
23
PLACAS VITROCERÁMICAS DE WOLF
ANTES DE COMENZAR
Es responsabilidad del propietario asegurarse de que la instalación se realiza de manera correcta. Esta placa debe ser instalada por un técnico cua­lificado. Debe asegurarse de que la instalación eléctrica es la correcta y que cumple todos los códigos y normativas nacionales.
Las instalaciones y reparaciones deben ser reali­zadas por un contratista cualificado o autorizado o por un electricista cualificado o autorizado por el estado, provincia o región en la que se va a instalar este aparato.
Compruebe que tiene todo lo necesario para que la instalación se lleve a cabo de la manera correcta. Es responsabilidad del instalador dejar los espacios requeridos para la instalación que se especifican en este documento y en la placa de datos del producto. La placa de datos está ubicada en la parte inferior del aparato. Observe la siguiente ilustración.
Este aparato necesita una conexión a tierra; consulte la sección Requisitos eléctricos en la página 34.
Esta placa está diseñada para que se utilice en espacios interiores.
REQUISITOS DE INSTALACIÓN
NOTA IMPORTANTE:
Guarde estas instrucciones de instalación para que el inspector local pueda utilizarlas.
Lea las instrucciones de instalación antes de llevar a cabo la instalación.
Esta instalación debe ser realizada por un técnico cualificado.
Instalador:
guarde estas instrucciones para que el inspector local pueda utilizarlas como referen­cia y, a continuación, entréguelas al propietario del aparato.
Propietario:
lea y guarde estas instrucciones para que pueda utilizarlas como referencia en el futuro y asegúrese de leer la guía de uso y mantenimiento antes de utilizar el aparato.
NOTA IMPORTANTE:
Este aparato debe instalarse siguiendo las normativas nacionales correspondi­entes. Se debe aplicar al aparato el voltaje, la frecuencia y el amperaje adecuados desde una instalación eléctrica resistente con toma de tierra protegida por un fusible de retardo. El voltaje, la frecuencia y la potencia se muestran en la placa de datos del producto.
Apunte la referencia del modelo y el número de serie antes de instalar el aparato. Esta información se muestra en la placa de datos del producto situada en la parte inferior de la placa. Observe la siguiente ilustración.
INFORMACIÓN DE LA PLACA DE DATOS
Referencia del modelo
Número de serie
Ubicación de la placa de datos
Ubicación de la placa
de datos debajo
de la vitrocerámica
24
PLACAS VITROCERÁMICAS DE WOLF
COLOCACIÓN EN LA ENCIMERA
A)
Superficie mínima de encimera plana. Debe ser igual o superior al ancho de la placa.
B)
Espacio mínimo de 25 mm desde el borde lateral de la placa a cualquier superficie combustible situada 457 mm por encima de la placa (área sombreada de la ilustración).
MEDIDAS DE LOS ARMARIOS SUPERIORES
C)
El espacio mínimo entre los armarios laterales superiores debe ser igual o superior al ancho nominal de la placa o placas.
D)
Debe existir una distancia vertical mínima de 457 mm desde la encimera hasta la parte inferior de los armarios laterales con una distancia lateral mínima.
E)
La distancia vertical mínima entre la encimera y los materiales combustibles situados por encima de la placa debe ser de 762 mm.
F)
Distancia mínima de 25 mm a la pared trasera.
G)
El fondo máximo de los armarios superiores laterales situados por encima de la placa debe ser de 330 mm con una distancia lateral mínima.
Si no coloca la placa siguiendo las distancias de separación correctas, es posible que se produzca un incendio.
C
G
D
A
B
B
E
F
Distancias mínimas de instalación
PREPARACIÓN DEL SITIO
NOTA IMPORTANTE:
La instalación de la placa vitrocerámica de Wolf debe cumplir los siguientes requisitos de colocación. Las medidas que se especi­fican son las mínimas para que el funcionamiento de la placa sea seguro. Observe la siguiente ilustración.
Para eliminar el riesgo de sufrir quemaduras o de que se produzca un incendio al alcanzar las superficies calientes, debe evitar colocar armarios por encima de los módulos de super­ficie. Si va a colocar armarios, el riesgo se puede reducir instalando una campana de extracción que sobresalga horizontalmente un mínimo de 127 mm de la parte inferior de los armarios.
25
INSTRUCCIONES DE INSTALACIÓN
ESPECIFICACIONES DE LA
INSTALACIÓN
Las ilustraciones de las páginas 26–31 proporcionan las medidas totales, las especificaciones de la insta­lación y las medidas del corte de la encimera para cada uno de los modelos de placas vitrocerámicas de Wolf.
Esta placa está diseñada para que se adapte a un armario de base estándar de 610 mm de fondo con una encimera de 635 mm de fondo. Antes de cortar la encimera, compruebe que la placa va a quedar separada de las paredes laterales del armario inferior.
Se necesita dejar un espacio para el bloque de termi­nales y para los cables en la parte trasera derecha de la placa. Observe la siguiente ilustración para ver las medidas.
VITROCERÁMICAS CON MARCO
Para los modelos con marco, debe dejar un espacio de 146 mm entre la encimera y cualquier superficie combustible por debajo de la placa.
Las vitrocerámicas con marco de Wolf están diseñadas para que se puedan instalar junto con otras placas.
NOTA IMPORTANTE:
Cuando instale varias placas juntas, consulte las dimensiones de corte de la encimera en la página 29.
Las vitrocerámicas con marco de Wolf pueden instalarse con un sistema de ventilación de tiro ascendente de Wolf. Consulte las instrucciones de instalación que se proporcionan con el sistema de ventilación de tiro ascendente para obtener más información.
56 mm
84 mm
24 mm
22 mm
32 mm
Medidas del bloque de terminales
VITROCERÁMICAS SIN MARCO
Para los modelos sin marco, debe dejar un espacio de 159 mm entre la encimera y cualquier superficie combustible que haya debajo de la placa.
NOTA IMPORTANTE:
Las vitrocerámicas sin marco de Wolf están diseñadas para que se puedan instalar junto con otras placas.
NOTA IMPORTANTE:
Las vitrocerámicas sin marco no se pueden instalar con un sistema de ventilación de tiro ascendente.
Si desea consultar las opciones de instalación de las vitrocerámicas sin marco, consulte la sección Instala­ciones sin marco en las páginas 32–33.
26
Medidas totales
Corte de la encimera
MODELO ICBCT15E
Anchura total 381 mm
Altura total 96 mm
Fondo total 533 mm
Fondo mínimo del armario 578 mm
Espacio mínimo de altura*
102 mm
Ancho del corte 340 mm
Fondo del corte 489 mm
ESPECIFICACIONES DE LA INSTALACIÓN – MODELO ICBCT15E
CON MARCO MODELO ICBCT15E
Las siguientes ilustraciones proporcionan las especi­ficaciones de instalación del modelo ICBCT15E.
Si instala el modelo ICBCT15E encima de los armarios, la colocación de la toma eléctrica no es importante. Es necesario colocar una caja de cone­xiones a una distancia de 1,2 m de la parte trasera derecha de la placa.
Cuando instale la placa encima de un horno, a menos que vaya a utilizar armarios con un fondo superior a 610 mm, se recomienda que la toma eléctrica se coloque en un armario base situado a la derecha del horno.
PLACAS VITROCERÁMICAS DE WOLF
NOTA IMPORTANTE:
No bloquee el ventilador
situado en la parte inferior de la placa.
*Se necesita dejar un espacio mínimo de altura
de 146 mm entre la encimera y cualquier super­ficie combustible que se encuentre justo encima de la placa.
Si desea obtener las medidas detalladas del
bloque de terminales, consulte la ilustración en la página 25.
Las medidas pueden variar ±3 mm.
533 mm
FONDO
TOTAL
381 mm
96 mm
ANCHURA TOTAL
127 mm
CAJA PARA TERMINAL
51** mm
330 mm
máx
489 mm
FONDO DE CORTE
DE LA PLACA
64 mm
mín
457 mm
914 mm
ALTURA ESTÁNDAR DEL SUELO
A LA ENCIMERA
838 mm
FONDO DEL ARMARIO
51 mm*mín
CORTE A
LOS MATERIALES
COMBUSTIBLES (AMBOS LADOS)
RECOMENDADO
340 mm
ANCHURA DE CORTE
DE LA PLACA
E
381 mm
102 mm
381 mm
762 mm
ENCIMERA A
SUPERFICIE
INFLAMABLE
SOBRE LA PLACA
NOTA: La aplicación que se muestra permite la instalación de dos módulos contiguos de 381 mm con un armario con una anchura recomendada de 838 mm. 457 mm de anchura de armario recomendada para la instalación de un solo módulo o superficie de cocción de 381 mm. *Espacio mínimo desde ambos bordes laterales del corte de la superficie de cocción hasta la superficie inflamable situada a 457 mm por encima de la encimera. **Espacio mínimo desde el borde trasero del corte de la superficie de cocción a la superficie inflamable situada a 457 mm sobre la encimera.
340 mm
ANCHURA DE CORTE
DE LA PLACA
489 mm
64 mm
mín
PARTE DELANTERA DE LA ENCIMERA
FONDO DE CORTE
DE LA PLACA
27
Medidas totales
Corte de la encimera
533 mm FONDO
TOTAL
762 mm
ANCHURA TOTAL
127 mm
96 mm
CAJA PARA TERMINAL
CON MARCO MODELO ICBCT30E
Las siguientes ilustraciones proporcionan las especi­ficaciones de instalación del modelo ICBCT30E.
Para que la instalación le resulte más sencilla, cuando instale el modelo ICBCT30E se recomienda utilizar armarios de 838 mm.
Se puede instalar un horno integrable sencillo de 914 mm ó 762 mm debajo del modelo ICBCT30E. Para esta instalación, a menos que vaya a utilizar armarios con un fondo superior a 610 mm, se recomienda que la toma eléctrica se coloque en un armario base situado a la derecha del horno.
Consulte las instrucciones de instalación que se proporcionan con el horno integrable para obtener más información.
Si instala el modelo ICBCT30E encima de los armarios, la colocación de la toma eléctrica no es importante. Es necesario colocar una caja de cone­xiones a una distancia de 1,2 m de la parte trasera derecha de la placa.
NOTA IMPORTANTE:
No bloquee el ventilador
situado en la parte inferior de la placa.
MODELO ICBCT30E
Anchura total 762 mm
Altura total 96 mm
Fondo total 533 mm
Fondo mínimo del armario 578 mm
Espacio mínimo de altura*
102 mm
Ancho del corte 721 mm
Fondo del corte 489 mm
ESPECIFICACIONES DE LA INSTALACIÓN – MODELO ICBCT30E
INSTRUCCIONES DE INSTALACIÓN
*Se necesita dejar un espacio mínimo de altura
de 146 mm entre la encimera y cualquier super­ficie combustible que se encuentre justo encima de la placa.
Si desea obtener las medidas detalladas del
bloque de terminales, consulte la ilustración en la página 25.
Las medidas pueden variar ±3 mm.
330 mm
51** mm
máx
489 mm
FONDO DE CORTE
DE LA PLACA
64 mm
mín
457 mm
610 mm mín
914 mm
ALTURA ESTÁNDAR DEL SUELO
A LA ENCIMERA
838 mm
FONDO DEL ARMARIO
RECOMENDADO
51 mm*min
CORTE A
LOS MATERIALES
COMBUSTIBLES (AMBOS LADOS)
762 mm mín
721 mm ANCHURA DE CORTE
DE LA PLACA
102 mm
95 mm
mín
762 mm CAVIDAD DEL HORNO
89 mm
254 mm
SOBRE LA PLACA
E
762 mm
ENCIMERA A
SUPERFICIE INFLAMABLE
*Espacio mínimo desde ambos bordes laterales del corte de la superficie de cocción hasta la superficie inflamable situada a 457 mm por encima de la encimera. **Espacio mínimo desde el borde trasero del corte de la superficie de cocción a la superficie inflamable situada a 457 mm sobre la encimera.
721 mm
ANCHURA DE CORTE DE LA PLACA
489 mm
FONDO DE CORTE
64 mm
mín
PARTE DELANTERA DE LA ENCIMERA
DE LA PLACA
28
PLACAS VITROCERÁMICAS DE WOLF
CON MARCO MODELO ICBCT36E
Las siguientes ilustraciones proporcionan las especi­ficaciones de instalación del modelo ICBCT36E.
Para que la instalación le resulte más sencilla, cuando instale el modelo ICBCT36E se recomienda utilizar armarios de 991 mm.
Se puede instalar un horno integrable sencillo de 914 mm o 762 mm debajo del modelo ICBCT36E. Para esta instalación, a menos que vaya a utilizar armarios con un fondo superior a 610 mm, se recomienda que la toma eléctrica se coloque en un armario base situado a la derecha del horno.
Consulte las instrucciones de instalación que se proporcionan con el horno integrable para obtener más información.
Si instala el modelo ICBCT36E encima de los armarios, la colocación de la toma eléctrica no es importante. Es necesario colocar una caja de cone­xiones a una distancia de 1,2 m de la parte trasera derecha de la placa.
NOTA IMPORTANTE:
No bloquee el ventilador
situado en la parte inferior de la placa.
Medidas totales
Corte de la encimera
MODELO ICBCT36E
Anchura total 914 mm
Altura total 96 mm
Fondo total 533 mm
Fondo mínimo del armario 578 mm
Espacio mínimo de altura*
102 mm
Ancho del corte 873 mm
Fondo del corte 489 mm
ESPECIFICACIONES DE LA INSTALACIÓN – MODELO ICBCT36E
*Se necesita dejar un espacio mínimo de altura
de 146 mm entre la encimera y cualquier super­ficie combustible que se encuentre justo encima de la placa.
Si desea obtener las medidas detalladas del
bloque de terminales, consulte la ilustración en la página 25.
Las medidas pueden variar ±3 mm.
533 mm FONDO
TOTAL
914 mm
96 mm
ANCHURA TOTAL
127 mm
CAJA PARA TERMINAL
51** mm
330 mm
máx
489 mm
FONDO DE CORTE
DE LA PLACA
610 mm mín
457 mm
64 mm
mín
914 mm
ALTURA ESTÁNDAR DEL SUELO
A LA ENCIMERA
991 mm
914 mm mín
873 mm
102 mm
95 mm
mín
914 mm CAVIDAD DEL HORNO
89 mm
254 mm
SOBRE LA PLACA
E
762 mm
ENCIMERA A
SUPERFICIE
INFLAMABLE
51 mm*mín
CORTE A LOS
MATERIALES COMBUSTIBLES (AMBOS LADOS)
FONDO DEL ARMARIO RECOMENDADO
ANCHURA DE CORTE DE LA PLACA
*Espacio mínimo desde ambos bordes laterales del corte de la superficie de cocción hasta la superficie inflamable situada a 457 mm por encima de la encimera. **Espacio mínimo desde el borde trasero del corte de la superficie de cocción a la superficie inflamable situada a 457 mm sobre la encimera.
ANCHURA DE CORTE DE LA PLACA
873 mm
FONDO DE CORTE
64 mm
mín
PARTE DELANTERA DE LA ENCIMERA
DE LA PLACA
489 mm
29
INSTRUCCIONES DE INSTALACIÓN
INSTALACIÓN DE OTRAS SUPERFICIES
DE COCCIÓN
Si la vitrocerámica con marco se va a utilizar con otras combinaciones de módulos o unidades de cocción adicionales con un embellecedor, el ancho del corte se calcula sumando las medidas de corte de las unidades correspondientes más 32 mm por cada unidad adicional. Observe la siguiente ilus­tración.
NOTA IMPORTANTE:
Para el modelo ICBCT15E, el ancho del corte debe aumentarse de 340 mm a 356 mm cuando se instale con varias unidades.
NOTA IMPORTANTE:
Las vitrocerámicas sin marco modelo ICBCT30EU y ICBCT36EU están diseñadas para que se puedan instalar junto con otras placas.
NOTA IMPORTANTE:
Cuando se instalen varias unidades juntas, cada unidad debe tener su propio circuito eléctrico recomendado.
Dimensiones de corte de la encimera para la instalación de otras superficies de cocción
ACCESORIOS
Podrá disponer de accesorios opcionales a través de su distribuidor de Wolf. Para obtener la infor­mación del distribuidor más cercano, visite nuestra página Web wolfappliance.com
Cuando se instalen dos o más módulos juntos, se recomienda utilizar un embellecedor de módulo integrado (IFILLER/S). Si además se instala un extractor de tiro ascendente de 762 mm, es nece­sario disponer de un soporte del módulo integrado para el extractor de tiro ascendente (ISUPPORT). Póngase en contacto con su distribuidor de Wolf para obtener información sobre estos accesorios.
1518 mm – ANCHURA DE CUATRO MÓDULOS O
1511 mm – 762 mm SUPERFICIE DE COCCIÓN Y DOS MÓDULOS Ó
1276 mm – 914 mm SUPERFICIE DE COCCIÓN Y UN MÓDULO
1130 mm – ANCHURA DE TRES MÓDULOS Ó
1124 mm – 762 mm SUPERFICIE DE COCCIÓN Y UN MÓDULO
743 mm
ANCHURA DE DOS MÓDULOS
356 mm
ANCHURA
64 mm
DEL CORTE
mín
PARTE DELANTERA DE LA ENCIMERA
489 mm
FONDO
DEL CORTE
Loading...