White Rodgers 50A55-3797 Specification

Trane Single Stage — 120V Ignitor HSI Integrated Furnace Control Kit
OEM Replacement
50A55-3797
Replaces:
White-Rodgers and Trane Single Stage HSI Controls with 120V Ignitors
Direct Replacement Is Fast and Easy.
50A55-3797 simplifies installation and ensures peak system performance.
Easy-Install Kit includes everything you need for quick and accurate replacement:
• Ignition Control Module
• Installation Instructions and OEM Cross-Reference
Integrated Furnace Module – 50A55-3797
Trane Single Stage — 120V Ignitor
OEM HSI Integrated Furnace Control Kit
Replaces:
White-Rodgers and Trane Single Stage HSI Controls with 120V Ignitors
Features
• 120 VAC Ignitor Output
• 120 VAC Humidifier Output
• 120 VAC Electronic Air Cleaner Output
• 120 VAC 2-Speed PSC Circulator Output
• Fuse Protection — 5 Amp
• Furnace Status LED
• Heat Fan OFF Delay (Dipswitch Selectable)
• Y, W, R, G, C
50A55-3797 Cross Reference
50A55-3797 Replaces:
Trane White-Rodgers
CNT02789 CNT02891 CNT03799 D341122P01 D341235P01 D341235P03
50A55-474 50A55-476 50A55-3797 50A55-571
Replacement
50A55-3797
Specifications
Electrical Ratings [@ 77°F (25°C)]
Input Voltage: 25 VAC 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp
Relay Load Ratings
Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive) Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VAC Circulator Relay: 14.5 FLA–25.0 LRA @ 120 VAC
Flame Current Requirements
Minimum current to insure flame detection: 1 µa DC* Maximum current for non-detection: 0.1 µa DC* Maximum allowable leakage resistance: 100 M ohms
*Measured with a DC microammeter in the flame probe lead
Operating Temperature Range
-40° to 175°F (-40° to 80°C)
Humidity Range
5% to 93% relative humidity (non-condensing)
Mounting
Surface mount multipoise
Timing Specifications (@ 60 Hz**)
Maximum Flame Establishing Time: 0.8 sec Flame Failure Response Time: 2.0 sec
**At 50 Hz, all timing specifications should be increased by 20%
Gases Approved: Natural, Manufactured, Mixed, Liquified Petroleum and LP Gas/Air Mixtures are all approved for use.
Dimensions
4.4" W x 5.9" H x 1.25" D
For Additional Information
Visit www.white-rodgers.com
Timing Specifications
(All times are in seconds unless noted otherwise)
50A55-3797
Pre-purge 0 Ignitor warm-up 17
(1st 64 attempts) Minimum ignitor warm-up 11 Maximum ignitor warm-up 21 Ignition activation period 3 Trial for ignition period 4 Retries 2 times Valve sequence period 12 Interpurge 60 Post-purge 5 Lockout time 300 Heat delay to fan ON 45 Heat delay to fan OFF* 60/100/140/180 Cool delay to fan ON 2 Cool delay to fan OFF 0/180 Auto reset 60 minutes Humidifier Yes Electronic air cleaner Yes
* These times will vary depending on option switch position. See OPERATION section for further information.
Saint Louis, Missouri Markham, Ontario
314-553-3600 905-948-3411
www.white-rodgers.com
www.emersonclimate.com
The Emerson logo is a trademark and a service mark of Emerson Electric Co.
WR-2258