White Rodgers 1F87-361, 1F80-361 Wiring and Configuration

N/A
Step
Press Button(s)
COMMENTSPress or to select:
Displayed
(Factory Default)
HOLD (0:00)
0 to 8 hrs (in
15 minute increments)
2
(FA)
SL
Select temporary Hold time
N/A
N/A
E
(ON)
OFF
4
5
LOC
(OFF)
ON
0 HI
(0)
4 LO to
4 HI
°(F) °C
Returns to normal operation
Returns to normal operation
6
7
Select Energy Management Recovery OFF or ON
Select Compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to °F or °C
RUN
PRGM
and RUN
*
*
3
d-L
(ON)
OFF
Select display backlight OFF or ON
*
*
Filter (000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
*
*
*
Select FA or SL (Fast or Slow) heating cycle rate
Configuration Menu
N/A
Step
2
N/A
4
5
6
7
8
3
1
Step
2
4
5
6
7
8
9
3
1
1
SYSTEM switch must be OFF to configure thermostat options
Set SYSTEM
switch to OFF
Set SYSTEM
switch to HEAT
or COOL
1N/AN/A
N/AN/A
N/AN/A
Step
2
4
N/A
5
6
7
8
3
1F80-241
1F80-361
1F86-241
1F86-344
1F87-361
Press Button(s)
RUN
1
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
N/A
1
N/A
*9
Step
2
4
5
N/A
6
7
8
3
*1F80-240
1
N/A
8
Step
2
N/A
N/A
4
5
6
7
3
1F80-224
* 1F80/1F87 - Press
HOLD to advance to next item or TIME to move backwards to previous item
1F86 - Press and
to advance to next item
1F80-240 is HEAT onl
y
RH
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Heat only, 3-wire, single transformer systems
TRANSFORMER
Heating System
Fan
Relay
YC
RC
JUMPER
WIRE
OB
For 1F80-361 and 1F86-344 2-wire Heat only, attach to RH and W.
NOTE
RH
Y
24 VAC
120 VAC
Hot
Neutral
TRANSFORMER
THERMOSTAT
SYSTEM
G W
Cool only, 3-wire, single transformer systems
Cooling System
Fan
Relay
RCOB
C
JUMPER
WIRE
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Heat/cool, 4-wire, single transformer systems
TRANSFORMER
Heating System
Fan
Relay
Cooling System
RC
JUMPER
WIRE
OC‡B
RED jumper wire (provided with thermostat) must be
connected between thermostat RH and RC terminals for proper thermostat operation with this system.
NOTE
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Heat/cool, 5-wire, two-transformer systems
HEATING
TRANSFORMER
Heating System
Fan
Relay
Cooling System
RC
24 VAC
120 VAC
Hot
Neutral
COOLING TRANSFORMER
OBC
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Heat pump with reversing valve energized in COOL
TRANSFORMER
Reversing
Valve*
RCOBC
JUMPER
WIRE
Compressor
Contactor
JUMPER
WIRE
* Reversing valve is energized when the system switch is in the COOL position
Fan
Relay
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Heat pump with reversing valve energized in HEAT
TRANSFORMER
Reversing
Valve*
RCOBC
JUMPER
WIRE
Compressor
Contactor
JUMPER
WIRE
* Reversing valve is energized when the system switch is in the HEAT position
Fan
Relay
CONFIGURATION AND
TECHNICAL HELP
www.white-rodgers.com
157
TYPICAL WIRING DIAGRAMS
1F80-224 / 1F80-240 / 1F80-241/1F80-361
1F86-241 / 1F86-344 / 1F87-361
CONFIGURATION
The following table allows you to customize the options on your Comfort-Set thermostat.
TYPICAL WIRING DIAGRAMS