ÉTAPES D’INSTALLATION FINALES ............................................................56
LISTE DE VÉRIFICATION POUR L’ACHÈVEMENT
DE L’INSTALLATION ......................................................................................59
Índice
SEGURIDAD DE LA LAVADORA/SECADORA .............................................60
REQUISITOS DE INSTALACIÓN ...................................................................63
REQUISITOS DE UBICACIÓN .......................................................................65
DIMENSIONES Y ESPACIOS LIBRES, MODELOS DE 27" (69 CM) ...........66
DIMENSIONES Y ESPACIOS LIBRES, MODELOS DE 24" (61 CM) ...........67
SISTEMA DE DESAGÜE ................................................................................68
REQUISITOS ELÉCTRICOS, MODELOS ELÉCTRICOS DE 240V ...............69
REQUISITOS ELÉCTRICOS, MODELOS ELÉCTRICOS DE 120V
(MODELOS DE 24" [61 CM] SOLAMENTE) ..................................................70
REQUISITOS ELÉCTRICOS, MODELOS A GAS
(MODELOS DE 27" [69 CM] SOLAMENTE) ..................................................71
REQUISITOS DEL SUMINISTRO DE GAS, MODELOS A GAS
(MODELOS DE 27" [69 CM] SOLAMENTE) ..................................................72
INSTALLATION NOTES
Date of purchase: ________________________________________
Date of installation: _______________________________________
Installer: _________________________________________________
Model number: ___________________________________________
Serial number: ___________________________________________
NOTAS DE INSTALACIÓN
Fecha de la compra: ______________________________________
Fecha de la instalación: ___________________________________
Instalador: _______________________________________________
Número de modelo: ______________________________________
Número de serie: _________________________________________
QUITE EL EMBALAJE DE HULE ESPUMA (MODELOS DE 24" [61 CM]) ....73
CONEXIÓN ELÉCTRICA, MODELOS ELÉCTRICOS
DE 27" (69 CM) (EE.UU. SOLAMENTE) ........................................................74
CONEXIÓN ELÉCTRICA, MODELOS ELÉCTRICOS
DE 24" (61 CM) DE 240V (EE.UU. SOLAMENTE) .........................................80
CONECTE LA MANGUERA DE DESAGÜE ...................................................87
CONECTE LAS MANGUERAS DE ENTRADA ..............................................88
CONEXIÓN DEL SUMINISTRO DE GAS (MODELOS A GAS
DE 27" [69 CM] SOLAMENTE) ......................................................................89
CONECTE EL DUCTO DE ESCAPE ..............................................................90
PASOS FINALES DE INSTALACIÓN .............................................................91
LISTA DE CONTROL PARA LA REALIZACIÓN
DE LA INSTALACIÓN .....................................................................................94
NOTES CONCERNANT L’INSTALLATION
Date d’achat : ____________________________________________
Date d’installation : _______________________________________
Installateur : _____________________________________________
Numéro de modèle : ______________________________________
Numéro de série : ________________________________________
W11028718A
Washer/Dryer Safety
2
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property
damage.
–
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this
or any other appliance.
–
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Clear the room, building, or area of all occupants.
•
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
•
instructions.
If you cannot reach your gas supplier, call the re department.
•
–
Installation and service must be performed by a qualied installer, service agency, or
the gas supplier.
In the State of Massachusetts, the following installation instructions apply:
■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by
the State of Massachusetts.
■ Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed.
■ A flexible gas connector, when used, must not exceed 4 feet (121.9 cm).
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part 1, CSA C22.1.
3
4
Installation Requirements
Tools and Parts
Gather required tools and parts before starting installation.
Tools needed:
Flat-blade screwdriver#2 Phillips screwdriver
Adjustable or open-end
wrench 9/16" (14 mm)
4" min
(102 mm)
Wood block
Pliers that open to 19/16"
(39.5 mm)
Level
Ruler or measuring tape
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Tin snips (new vent
installations)
Tools needed for gas installations:
8" (203 mm) or 10"
(254 mm) pipe wrench
Pipe-joint compound
resistant to propane gas
8" (203 mm) or 10"
(254 mm) adjustable wrench
(for gas connections)
Optional tools:
1/4" (6.5 mm) nut driver
(recommended)
Caulking gun and compound
(new vent installations)
FlashlightBucket
Wire stripper
Utility knife
5
Parts supplied:
NOTE: Remove parts package from the washer basket.
Check that all parts were included.
Plastic strap
Silver double-wire
hose clamp
Drain hose
Anti-tip brackets (2)
and screws (4)
(27" [69 cm] models)
Parts needed: (Not supplied with washer/dryer)
n
Vent clamps
n
Vent elbows and ductwork
n
Mobile Home Installation Kit
(Part Number 346764)
n
Metal exhaust system hardware
Alternate parts:(Not supplied with washer/dryer)
Your installation may require additional parts. To order, please
refer to the toll-free numbers on the back page of your Use and
Care Guide.
If you have: You will need:
Overhead sewer Standard 20 gal. (76 L) 39" (991 mm)
tall Drain Tub or Utility Sink, Sump
Pump and Connectors (available from
local plumbing suppliers)
Floor drain Siphon Break Part Number 285320,
Additional Drain Hose Part Number
285702, and Connector Kit Part
Number 285442
1" (25 mm) standpipe 2" (51 mm) diameter to 1" (25 mm)
diameter Standpipe Adapter
Part Number 3363920,
Connector Kit Part Number 285835
Laundry tub or Sump pump system (if not already
standpipe taller than available)
96" (2.4 m)
Drain hose too short Extension Drain Hose
Part Number 285863,
Connector Kit Part Number 285835
Lint clogged drain Drain Protector Part Number 367031,
Connector Kit Part Number 285835
Water faucets Two longer water ll hoses:
beyond reach 6 ft (1.8 m) Part Number 76314,
of ll hoses 10 ft (3.0 m) Part Number 350008
Inlet hoses with
flat washers
Check local codes, electrical supply and venting, and read
“Electrical Requirements” and “Venting Requirements” before
purchasing parts. Mobile home installations require metal
exhaust system hardware available for purchase from the
dealer from whom you purchased your washer/dryer. For
further information, please reference the “Assistance or
Service” section of the Washer/Dryer Use and Care Guide.
Optional equipment: (Not supplied with washer/dryer)
Refer to your Use and Care Guide for information about
accessories available for your washer/dryer.
6
Location Requirements
(155 cm
Recessed area or closet installation
2
48 in.
(310 cm2)
3"
(76 mm)
Select proper location for your washer/dryer to improve
performance and minimize noise and possible “washer walk.”
Install your washer/dryer in a basement, laundry room, closet,
or recessed area.
You will need:
nA location that allows for proper exhaust installation.
A washer/dryer must be exhausted to the outdoors.
See “Venting Requirements.”
n For 27" (69 cm) and 24" (61 cm) 240V electric models, a
separate 30 amp circuit. For 24" (61 cm) 120V electric models,
a separate 20 amp circuit. For gas models, a separate 120V
15 or 20 amp circuit.
nFor 27" (69 cm) electric models using a power supply
cord, for 24" (61 cm) electric models, and for gas models,
a grounded electrical outlet located within 2 ft (610 mm) of
either side of the washer/ dryer. See “Electrical Requirements.”
nA sturdy oor to support the washer/dryer weight (washer/
dryer, water, and load) of 500 lbs (226.8 kg).
nA level oor with a maximum slope of 1" (25 mm) under entire
washer/dryer. Clothes may not tumble properly and automatic
sensor cycles may not operate correctly if washer/dryer is not
level. Installing on carpet is not recommended.
n A water heater set to deliver 120°F (49°C) water to the washer.
nHot and cold water faucets located within 4 ft (1.2 m) of the
hot and cold water ll valves, and water pressure of 5–100 psi
(34.5–689.6 kPa).
The washer/dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
Do not operate your washer in temperatures at or below 32ºF
(0ºC). Some water can remain in the washer and can cause
damage in low temperatures. See “Washer/Dryer Care” in the
Washer/Dryer Use and Care Guide for winterizing information.
Do not operate your dryer at temperatures below 45°F (7°C).
At lower temperatures, the dryer might not shut off at the end
of an automatic cycle. This can result in longer drying times.
Check code requirements. Some codes limit, or do not permit,
installation of the washer/dryer in garages, closets, mobile
homes, or sleeping quarters. Contact your local building
inspector.
Front
View
24 in.
2
2
)
Closet
door
3"
(76 mm)
The spacing dimensions on the following pages are
recommended for this washer/dryer. This washer/dryer
has been tested for spacing of 0" (0 mm) clearance at
the sides and back. Recommended spacing should be
considered for the following reasons:
nAdditional spacing should be considered for ease of
installation and servicing.
nAdditional clearances might be required for wall, door,
and oor moldings.
nAdditional spacing on all sides of the washer/dryer is
recommended to reduce noise transfer.
nFor closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
NOTE: For gas models, no other fuel-burning appliance can
be installed in the same closet as the washer/dryer.
Mobile Home – Additional Installation Requirements
This washer/dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or the Canadian
Manufactured Home Standard, CAN/CSA-Z240 MH.
Mobile home installations require:
nMetal exhaust system hardware, which is available
for purchase from your dealer.
nMobile Home Installation Kit Part Number 346764 (gas
models only). See “Tools and Parts” for ordering information.
nSpecial provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
7
Dimensions/Clearances, 27" (69 cm) Models
(1918 mm)
(824 mm)
Dimensions
Front View
Side View
75½"
(1918 mm)
4715/16"
(1218 mm)
1
27
/4"
(692 mm)
(704 mm)
Clearances
Side Clearances (recommended/minimum)
1"/0"
(25 mm/0 mm)
11
27
/16"
Front/Back/Top Clearances (recommended/minimum)
1"/0"
(25 mm/0 mm)
Back View
6113/16"
(1570 mm)
11½"
(292 mm)
35¾"
(908 mm)
271/4"
(692 mm)
327/16"
75½"
75½"
(1918 mm)
1"
(25 mm)
(Closet)*
(25 mm/0 mm)
5"
(127 mm)**
1"/0"
13"
45"
(1143 mm)
39"
(991 mm)
(330 mm)
3615/16"
(938 mm)
**Required spacing.
** Rear clearance may be 0" (0 mm) when house exhaust system is lined up directly with dryer exhaust.
8
Dimensions/Clearances, 24" (61 cm) Models
)
(25 mm/0 mm
Dimensions
Front View
Side View
74¼"
(1886 mm)
7
/16"
36
(926 mm)
7
23
/8"
(607 mm)
20
¾
(527 mm)
Clearances
Side Clearances (recommended/minimum)
1"/0"
)
"
Front/Back/Top Clearances
1"/0"
(25 mm/0 mm
12"
(305 mm)
62"
(1575 mm)
Back View
5
47
(1210 mm)
/8"
3311/16"
(856 mm)
12"
(305 mm)
401/8"
(1019 mm)
265/8"
(676 mm)
237/8"
(607 mm)
40¼"
(1022 mm)
12"
(305 mm)
3115/16"
(811 mm)
74¼"
(1886 mm)
74¼"
(1886 mm)
1"
(25 mm)
(Closet)*
5"
(127 mm)**
**Required spacing.
** Rear clearance may be 0" (0 mm) when house exhaust system is lined up directly with dryer exhaust.
9
Drain System
Drain system can be installed using a oor drain, wall standpipe,
oor standpipe, or laundry tub. Select method you need.
Floor standpipe drain system
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum
carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe
must be at least 39" (991 mm) high; install no higher than 96"
(2.4 m) from bottom of washer/dryer. If you must install higher
than 96" (2.4 m), you will need a sump pump system.
Wall standpipe drain system
See requirements for oor standpipe drain system.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number
285834), two Connector Kits (Part Number 285385), and an
Extension Drain Hose (Part Number 285863) that may be
purchased separately. To order, please see toll-free phone
numbers in your Use and Care Guide. Minimum siphon break:
28" (710 mm) from bottom of washer/dryer. (Additional hoses
may be needed.)
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be
at least 39" (991 mm) above oor on 27" (69 cm) models, or 34"
(864 mm) above oor on 24" (61 cm) models; install no higher
than 96" (2.4 m) from bottom of washer/dryer.
IMPORTANT: To avoid siphoning, no more than 4.5" (114 mm)
of drain hose should be inside standpipe or below the top of
wash tub. Secure drain hose with plastic strap.
10
Electrical Requirements, 240V Electric Models – U.S.A.
n This washer/dryer is manufactured ready to install with a
3-wire electrical supply connection. The neutral ground wire is
permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection, the neutral ground wire must be removed
from the external ground connector (green screw), and
secured under the neutral terminal (center or white wire) of the
terminal block. When the neutral ground wire is secured under
the neutral terminal (center or white wire) of the terminal block,
the dryer cabinet is isolated from the neutral conductor.
n If local codes do not permit the connection of a neutral ground
wire to the neutral wire, see “Optional 3-wire connection” in
the “Electrical Connection” section.
n A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes prohibit grounding through the neutral
conductors.
If using a power supply cord:
n It is recommended that a separate circuit breaker serving
only this appliance be provided.
n To minimize possible shock hazard, the cord must be plugged
into a mating, 3 or 4 prong, grounding-type outlet, grounded
in accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly grounded
outlet installed by a qualied electrician.
n If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
n Check with a qualied electrician if you are not sure the
washer/dryer is properly grounded.
n Do not have a fuse in the neutral or ground circuit.
It is your responsibility:
n To contact a qualied electrical installer.
n To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70 – latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
n To supply the required 3- or 4-wire, single phase, 120/240
volt, 60 Hz., AC only electrical supply (or 3- or 4-wire, 120/208
volt electrical supply, if specied on the serial/rating plate) on
a separate 30 amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit.
n Do not use an extension cord.
Electrical Connection
To properly install your washer/dryer, you must determine the
type of electrical connection you will be using and follow the
instructions provided for it here.
Use a UL Listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
n A UL Listed 30 amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
n A UL Listed strain relief.
If your outlet looks like this:
Then choose a 4-wire power supply cord with ring
or spade terminals and UL Listed strain relief. The
4-wire power supply cord, at least 4 ft (1.22 m)
long, must have four 10-gauge copper wires and
match a 4-wire receptacle of NEMA Type 14-30R.
4-wire
receptacle
(14-30R)
The ground wire (ground conductor) may be either
green or bare. The neutral conductor must be
identied by a white cover.
If your outlet looks like this:
Then choose a 3-wire power supply cord with ring
or spade terminals and UL Listed strain relief. The
3-wire power supply cord, at least 4 ft (1.22 m) long,
must have three 10-gauge copper wires and match
a 3-wire receptacle of NEMA Type 10-30R.
3-wire
receptacle
(10-30R)
If connecting by direct wire (27" [69 cm] models only):
Power supply cable must match power supply (4-wire or 3-wire)
and be:
n Flexible armored cable or nonmetallic sheathed copper
cable (with ground wire), covered with exible metallic
conduit. All current-carrying wires must be insulated.
n 10-gauge solid copper wire (do not use aluminum).
n At least 5 ft (1.52 m) long.