Whirlpool AKM 489, AKM 488/IX, AKM489 / IX Manual

0 (0)

INSTRUCTIONS FOR USE

PRODUCT DESCRIPTION AND SYMBOLS

USING THE BURNERS

PRACTICAL ADVICE ON USING THE HOB

POSITIONING THE PAN SUPPORTS AND WOK SUPPORT HOOD AND CABINETRY CLEARANCES (MM)

INJECTOR TABLE

WARNINGS AND SUGGESTIONS

SAFEGUARDING THE ENVIRONMENT

INSTALLATION (FLUSH AND TRADITIONAL FITTING) GAS CONNECTION

ELECTRICAL CONNECTION

FIXING THE HOB TO THE WORK TOP. TRADITIONALLY FITTED MODEL

FIXING THE HOB TO THE WORK TOP. FLUSH FITTED MODEL ADAPTION TO A DIFFERENT TYPE OF GAS SUPPLY REPLACING THE INJECTORS

FITTING THE WOK BURNER

REGULATING THE MINIMUM FLOW LEVEL OF THE GAS TAPS GENERAL CLEANING & MAINTENANCE

CARE AND MAINTENANCE OF THE GAS BURNERS TROUBLESHOOTING GUIDE

AFTER SALES SERVICE

17

PRODUCT DESCRIPTION AND SYMBOLS

1.Removable pan supports

2.1 kWh auxiliary burner

3.1.65 kWh semi-fast burner

4.3 kWh fast burner

5.1.65 kWh semi-fast burner

6.Professional wok burner

7. Auxiliary burner control knob

8. Semi-fast burner control knob

9. Fast burner control knob

10. Semi-fast burner control knob

11. Professional wok burner control knob

Control Symbols

Off

Maximum flame

Minimum flame

USING THE BURNERS

To turn on one of the burners:

1.Turn the corresponding control knob anticlockwise until the indicator coincides with the maximum flame symbol .

2.Press the control knob to ignite the burner.

3.Once the burner has lit, keep the control knob pressed for about 5 seconds to allow the safety thermocouple fitted to each burner to engage. The thermocouple will switch off the gas supply to the burner should the flame be accidentally lost (A gust of air, momentary interruption of gas supply or liquid spillage etc).

If the burner does not ignite within about 15 seconds, switch off the burner, check the fitting of the burner cap and plate for correct fitting. Wait at least 1 minute before trying again.

If the burner goes out when the control knob is released, the thermocouple did not engage. wait at least 1 minute before repeating steps 1 to 3.

18

Whirlpool AKM 489, AKM 488/IX, AKM489 / IX Manual

PRACTICAL ADVICE ON USING THE HOB

Read the instructions to get the best out of your hob.

Use pans with a similar diameter to the burner (see the table on this page).

Use flat bottomed pans except with the wok support.

Do not use excessive water when cooking foods and use the lid.

Ensure that pans are fully supported by the pan supports and do not protrude over the edges.

You should never use:

two burners simultaneously with just one container such as a fish kettle.

Important:

Do not rest or drag the pan supports upside down on the hob as this could scratch it.

Failure to comply with these recommendations could lead to the glass ceramic hob being damaged, or broken and the safety of your appliance being compromised.

Burner

Pan diameter

wok

from 24 to 26 cm

fast

from 24 to 26 cm

semi fast

from 16 to 24 cm

auxiliary

from 8 to 14 cm

POSITIONING THE PAN SUPPORTS AND WOK SUPPORT

Position the pan supports and wok support as indicated in the diagram.

19

HOOD AND CABINETRY CLEARANCES (MM)

If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct height above the hob.

INJECTOR TABLE

CATEGORY: II2H3+

 

 

 

 

 

Control

Nominal

 

 

 

Reduced

Gas pressure

Type of gas

Type of

Injector

primary

heat

 

Nominal

 

(mbar)

 

 

heat flow

 

 

used

burner

label

air (X)

flow

consumption

 

 

 

 

 

min.

nom.

max.

 

 

 

 

 

(mm)

 

kW

 

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

wok

 

145

6

 

4,20

 

400 l/h

1.40

 

 

 

 

 

 

GAS

fast

 

128

-

 

 

3,00

 

286 l/h

0.90

 

17

 

20

 

25

(Methane)

semi-fast

95

-

 

 

1,65

 

157 l/h

0.40

 

 

 

 

 

 

 

 

 

 

 

 

G20

auxiliary

78

-

 

 

1,00

 

 

95 l/

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

wok

 

100

11

 

4,20

 

305 g/h

1.40

 

 

 

 

 

 

PETROLEUM

fast

 

85

-

 

 

3,00

 

218 g/h

0.90

 

25

 

30

 

35

GAS (Butane)

semi-fast

65

-

 

 

1,65

 

120 g/h

0.40

 

 

 

 

 

 

 

 

 

 

 

 

G30

auxiliary

50

-

 

 

1,00

 

73 g/h

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

wok

 

100

11

 

4,20

 

300 g/h

1.40

 

 

 

 

 

 

PETROLEUM

fast

 

85

-

 

 

3,00

 

214 g/h

0.90

 

25

 

30

 

35

GAS (Propane)

semi-fast

65

-

 

 

1,65

 

118 g/h

0.40

 

 

 

 

 

 

 

 

 

 

 

 

G31

auxiliary

50

-

 

 

1,00

 

71 g/h

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuration

 

Nominal heat

 

Overall nominal

 

Required air (m3)

Type of gas used

 

 

 

 

 

for the

 

 

 

model

 

 

 

flow kW

 

 

consumption

 

combustion 1 m3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G20 20 mbar

 

 

5 burners

 

 

 

11,50

 

 

1090 l/h

 

 

9,52

 

 

G30 28-30 mbar

 

 

5 burners

 

 

 

11,50

 

 

836 g/h

 

 

30,94

 

 

G31 37 mbar

 

 

5 burners

 

 

 

11,50

 

 

821 g/h

 

 

23,80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electric Power: 230 V - 50 Hz