Whirlpool ACQ102PV, ACQ108PV, ACQ128GPW Use And Care Manual

0 (0)
®
ROOM AIR
CONDITIONER
Use & Care Guide
For questions about features, operation/performance, parts
or service, call: 1-877-465-3566.
or visit our website at... www.whirlpool.com
In Canada, for assistance, installation or service,
call: 1-800-360-2742
DE AIRE PARA
HABITACIÓN
Manual de uso y cuidado
Si tiene preguntas respecto a las características, funcionamiento,
o visite nuestro sito de internet en... www.whirlpool.com
rendimiento, partes o servicio técnico,
llame al: 1-877-465-3566
CLIMATISEUR
DE PIÈCE
Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service,
Table of Contents/Índice/Table des matières ...... 2
composez le : 1-800-360-2742
ou visitez notre site web à... www.whirlpool.com
1307258
TABLE OF CONTENTS
AIR CONDITIONER SAFETY .........................................................3
INSTALLATION REQUIREMENTS................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................4
Electrical Requirements ............................................................... 4
INSTALLATION INSTRUCTIONS..................................................5
Unpack the Air Conditioner.......................................................... 5
Prepare Air Conditioner for Installation........................................6
Prepare Window for Installation...................................................7
Position the Air Conditioner .........................................................7
Complete Installation ...................................................................9
AIR CONDITIONER USE................................................................9
Starting Your Air Conditioner—Digital Control ............................9
Using the Remote Control .........................................................11
ÍNDICE
SEGURIDAD DEL ACONDICIONADOR DE AIRE......................18
REQUISITOS DE INSTALACIÓN.................................................18
Herramientas y piezas................................................................18
Requisitos de ubicación.............................................................19
Requisitos eléctricos..................................................................19
INSTRUCCIONES DE INSTALACIÓN.........................................21
Desempaque el acondicionador de aire....................................21
Prepare el acondicionador de aire para la instalación ..............21
Prepare la ventana para la instalación.......................................22
Cómo colocar el acondicionador de aire ..................................22
Complete la instalación..............................................................24
CÓMO USAR SU ACONDICIONADOR DE AIRE.......................24
Cómo poner en marcha su acondicionador de aire—
Control digital .............................................................................24
Starting Your Air Conditioner—Rotary Control..........................13
Changing Air Direction ...............................................................13
Exhaust Air Vent .........................................................................14
Normal Sounds...........................................................................14
AIR CONDITIONER CARE ...........................................................14
Cleaning the Air Filter .................................................................14
Cleaning the Front Panel............................................................14
Repairing Paint Damage ............................................................14
Annual Maintenance...................................................................14
TROUBLESHOOTING ..................................................................15
ASSISTANCE OR SERVICE.........................................................16
In the U.S.A. ...............................................................................16
In Canada ...................................................................................16
Cómo usar el control remoto .....................................................26
Cómo poner en marcha su acondicionador de aire—
Control rotativo...........................................................................28
Cómo cambiar la dirección del aire ...........................................29
Ducto de escape de aire ...........................................................29
Sonidos normales.......................................................................29
CÓMO CUIDAR SU ACONDICIONADOR DE AIRE...................30
Limpieza del filtro de aire ...........................................................30
Limpieza del panel delantero .....................................................30
Reparación de la pintura dañada...............................................30
Mantenimiento anual..................................................................30
SOLUCIÓN DE PROBLEMAS......................................................30
AYUDA O SERVICIO TÉCNICO...................................................32
En los EE.UU. .............................................................................32
TABLE DES MATIÈRES
SÉCURITÉ DU CLIMATISEUR ....................................................33
SPÉCIFICATIONS D’INSTALLATION .........................................33
Outils et pièces...........................................................................33
Exigences d’emplacement.........................................................34
Spécifications électriques..........................................................34
INSTRUCTIONS D'INSTALLATION ............................................36
Déballage du climatiseur............................................................36
Préparer le climatiseur pour l’installation...................................36
Préparer la fenêtre pour l’installation.........................................37
Positionnement du climatiseur...................................................37
Pour compléter l’installation ......................................................39
UTILISATION DU CLIMATISEUR................................................39
Mise en marche du climatiseur—
Module de commande numérique.............................................39
Utilisation de la télécommande..................................................41
Mise en marche du climatiseur—
Module de commande rotatif.....................................................43
Changement de direction de l'air...............................................43
Ventilation...................................................................................44
Sons normaux ............................................................................44
ENTRETIEN DU CLIMATISEUR ..................................................44
Nettoyage du filtre à air..............................................................44
Nettoyage du panneau avant.....................................................44
Remise en état de la peinture ....................................................44
Entretien annuel..........................................................................44
DÉPANNAGE.................................................................................45
ASSISTANCE OU SERVICE.........................................................46
Aux États-Unis............................................................................46
Au Canada..................................................................................47
2
AIR CONDITIONER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
Plug into a grounded 3 prong outlet.
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
follow instructions.
can be killed or seriously injured if you don't
You instructions.
Do not use an extension cord.
follow
Do not remove ground prong.
Do not use an adapter.
SAVE THESE INSTRUCTIONS
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Too ls ne ed ed
Phillips screwdriver
Scissors
Level
Tape measure
Cordless drill and ¹⁄₈" bit
Pencil
Unplug air conditioner before servicing.
Use two or more people to move and install air conditioner.
Parts supplied
Check that all parts are included in parts package.
A
B
G
³⁄₄
" screws (12)
F.
G. Side curtains (2)
A. Adhesive seal B. Foam seal
C
D
C. L brackets (2) D. Side brackets (2)
E.
³⁄₈
" screws (8)
EF
3
Location Requirements
A
A
IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation. The location should provide:
Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner. NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
Adequate wall support for weight of air conditioner. Air
conditioner weighs 71 lbs to 135 lbs (32.2 kg to 61.2 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.
Window installation
Window opening measurements:
24" (61 cm) minimum to 36" (91.4 cm) maximum opening
width.
15" (38.1 cm) minimum opening height.
A
B
A. 24" (61 cm) minimum B. 15" (38.1 cm) minimum
A. Cabinet louvers
Electrical Requirements
WARNING
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located on the right-hand side of the air conditioner cabinet.
Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.
Power supply cord Wiring requirements
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer's responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer.
4
It is the customer's responsibility:
B
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 ­latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association One Batterymarch Park Quincy, MA 02269
Power Supply Cord
NOTE: Your air conditioner’s device may differ from the one
shown.
A
RESET
TEST
A. Test button B. Reset button
This room air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is crushed, the electronics detect leakage current and power will be disconnected in a fraction of a second.
WARNING
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (on some devices, a green light will turn on).
3. Press TEST (listen for click; Reset button will trip, and on
some devices, a green light will turn off).
4. Press and release RESET (listen for click; Reset button will
latch, and on some devices, a green light will turn on). The power supply cord is ready for operation.
NOTES:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch. The
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer and must not be repaired.
The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and performance claims.
INSTALLATION INSTRUCTIONS
WARNING
Excessive Weight Hazard
Use two or more people to move and install air conditioner.
Failure to do so can result in back or other injury.
Remove packaging materials
Remove and dispose of/recycle packaging materials.
Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.
Unpack the Air Conditioner
Do not use sharp instruments, rubbing alcohol, flammable
fluids or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner.
Handle the air conditioner gently.
5
Prepare Air Conditioner for Installation
Install Side Curtains
NOTE: Attach curtains to the air conditioner before placing the air
conditioner in window.
1. Locate provided bag of screws.
2. Insert top and then bottom of right-hand curtain housing in
top and bottom curtain channels on air conditioner.
Back View
3. Extend right-hand curtain outward so you may insert a ³⁄₈"
screw through the top hole in the curtain. Using a ³⁄₈" screw, screw curtain to the top hole in the air conditioner cabinet.
NOTE: This screw is required to correctly attach curtain (top to bottom) to the air conditioner cabinet.
Front View
Bottom View
A. Curtain housing B. Curtain bottom channel on air conditioner
A
A. Curtain housing B. Curtain top channel on air conditioner
B
A
B
4. While the right-hand curtain is still extended, insert ³⁄₈" screws
through the other three holes in the curtain. Screw curtain to all four holes in the air conditioner cabinet.
5. Slide the curtain housing into the channels as far as it will go.
6. Repeat above steps for the left-hand curtain.
6
Prepare Window for Installation
B
C
Attach Adhesive Seal
1. Cut the adhesive seal to the width of the lower window sash.
2. Remove the backing from the seal and attach the seal to the
bottom of the lower window sash.
2. Use ¹⁄₈" drill bit to drill a starter hole for each of the two L
brackets located 8¹⁄₈" from the center line.
3. Using ³⁄₄" screws, install the L brackets on the outside
windowsill. The short side of the brackets should face toward the outside.
B
C
A
D
B
F
E
E
Install L Brackets
1. Measure the width of the window opening and mark the
center line on the outside windowsill.
A
B
A. Width of window opening B. Center line
Position the Air Conditioner
WARNING
Excessive Weight Hazard
Use two or more people to move and install air conditioner.
Failure to do so can result in back or other injury.
A. Outside windowsill
³⁄₄
" screw
B. C. Inside windowsill
D. Center line
E. 7
¹⁄₂
"
F. Short side of bracket
NOTE: Your model may differ from the one shown.
NOTES:
Handle air conditioner gently.
Be sure your air conditioner does not fall out of the opening
during installation or removal.
The place where the power cord exits the air conditioner
should be no more than 6 ft (182.9 cm) from a grounded outlet.
Do not block the louvers in the front panel.
Do not block the louvers on the outside of the air conditioner.
1. Center air conditioner in window. Be sure the bottom
channels on the air conditioner drop into the notches of the L brackets. Lower the window sash behind the top channel to hold cabinet in place.
A
A. Side curtain against window channel B. Window sash behind top channel
C. Bottom channel in bracket notches
7
2. Remove the screw on the right-hand side of the air
conditioner cabinet near the bottom.
6. Repeat for side bracket installation on the left-hand side of
the air conditioner.
Attach Side Curtains to Window
1. Pull the left-hand curtain out until it fits into the window
channel.
2. Use ¹⁄₈" drill bit to drill a starter hole through the hole in the
side curtain and window sash.
3. Insert one of the ³⁄₄" screws through the left-hand curtain and
into the window sash.
4. Repeat for the right-hand curtain.
3. Attach the side bracket to the air conditioner cabinet.
4. Use ¹⁄₈" drill bit to drill a starter hole through the holes in the
side bracket and windowsill.
5. Using two ³⁄₄" screws, attach the side bracket to the
windowsill.
Window Sash View
A
B
C
A. Window sash B. Hole in side curtain C.
³⁄₄
" screw
5. Drill a starter hole through the notch in the side curtain and
the windowsill.
6. Insert one of the ³⁄₄" screws through curtain notch and into
the windowsill.
7. Repeat for the right-hand curtain.
8
Windowsill View
A
B
C
³⁄₄
" screw
A. B. Notch in side curtain C. Windowsill
Complete Installation
B
1. Insert foam seal behind the top of the lower window sash and
against the glass of the upper window.
A
A. Top of lower window sash B. Foam seal
2. Use a ¹⁄₈" drill bit to drill a starter hole through the hole in the
top channel.
3. Attach the top channel to the window sash with one ³⁄₄" screw
to secure the window in place.
WARNING
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
4. Plug into a grounded 3 prong outlet.
5. Press RESET on the power supply cord. See “Electrical
Requirements.”
AIR CONDITIONER USE
Operating your air conditioner properly helps you to obtain the best possible results.
This section explains proper air conditioner operation. IMPORTANT:
If you turn off the air conditioner, wait at least 3 minutes
before turning it back on. This prevents the air conditioner from blowing a fuse or tripping a circuit breaker.
Starting Your Air Conditioner—Digital Control
NOTE: When the air conditioner is set to Fan mode and the room temperature is below 32ºF (0ºC), the display will show LO. If the room temperature is above 99ºF (37ºC), the display will show HI.
Do not try to operate your air conditioner in the Cool mode
when outside temperature is below 65°F (18°C). The inside evaporator coil will freeze up, and the air conditioner will not operate properly.
NOTE: In the event of a power failure, your air conditioner will operate at the previous settings when the power is restored.
1. Remove the clear protective film from the front panel badge.
2. Press POWER to turn on the air conditioner.
NOTE: When the air conditioner is turned on for the first time
after it is plugged in, the display will show the current room temperature and will run in the 6 When the air conditioner is turned on at all other times, the display will show the previous settings for 5 seconds, and then show the current room temperature.
3. Select mode. See “Mode.”
4. Select fan speed. See “Fan Speed.”
5. Set temperature. See “Temperature.”
th
Sense™ System control.
9
Mode
Filter Monitor
1. Press MODE until you see the indicator light glow for the
desired setting.
2. Choose Cool, Dry or Fan.
CoolCools the room. Press FAN SPEED to select High,
Med, Low or Auto. Press the plus or minus TEMP button to adjust the temperature.
Dry—Dries the room. The air conditioner automatically
selects the temperature. Fan runs on Low speed only. NOTE: Dry mode should not be used to cool the room.
FanOnly the fan runs. Press FAN SPEED to select High,
Med or Low. The display shows the current room temperature.
NOTE: Auto fan speed cannot be selected in Fan mode.
NOTE: After 5 seconds, display will show the current room
temperature.
Fan Speed
NOTE: The Fan Speed button will operate only when the Cool or
Fan mode has been selected.
1. Press FAN SPEED until you see the indicator light glow for
the desired setting.
2. Choose High, Med, Low or Auto.
Highfor maximum cooling
Medfor normal cooling
Lowfor sleeping comfort
Autoautomatically controls the fan speed depending on
the current room temperature and temperature control setting
NOTE: Auto fan speed cannot be selected in Fan mode.
1. When Filter Monitor indicator light is lit, remove, clean and
replace the air filter. See “Cleaning the Air Filter.”
2. Press FILTER MONITOR after cleaning and replacing the air
filter. This resets the filter monitor.
NOTE: After 360 hours of fan operating time, the filter indicator light will turn on. It will remain on for 180 hours or until you press FILTER MONITOR. After 180 hours, it will turn off automatically.
Temperature
Press the plus TEMP button to raise the temperature. Each
time you press or hold the plus TEMP button, the temperature will go up 2ºF (1ºC) until it reaches 90°F (32°C).
NOTE: After 5 seconds, the display will show the current room temperature.
Press the minus TEMP button to lower the temperature. Each
time you press or hold the minus TEMP button, the temperature will go down 2ºF (1ºC) until it reaches 64°F (18°C).
NOTE: After 5 seconds, the display will show the current room temperature.
NOTE: After 5 seconds, the display will show the current room temperature.
10
Timer Delay
To set the Timer for a 30-minute to 24-hour delay until the air conditioner turns off (the air conditioner must be On):
1. Press TIMER. Timer indicator light will flash. Display will show
remaining hours before the air conditioner will turn off.
2. Press the plus or minus TEMP button to change the delay
time from 30 minutes to 24 hours.
3. After 5 seconds, Timer indicator light will remain on. Display
will show the current room temperature.
To set the Timer to turn on the air conditioner, keeping previous settings:
1. Turn off air conditioner.
2. Press TIMER. Timer indicator light will flash. Display will show
remaining hours before the air conditioner will turn on.
3. Press the plus or minus TEMP button to change the delay
time from 30 minutes to 24 hours.
4. After 5 seconds, Timer indicator light will remain on. Display
will show the current room temperature.
To set the Timer to turn on the air conditioner, changing the previous settings:
1. Turn on air conditioner.
2. Adjust the mode to Cool, Dry or Fan.
3. For Cool mode:
Adjust fan speed to High, Med, Low or Auto.
Adjust temperature between 64ºF and 90ºF (18ºC and
32ºC).
4. For Fan mode, adjust fan speed to High, Med or Low. NOTE: In Fan mode, temperature cannot be set.
5. For Dry mode, adjust temperature up or down by 4ºF (2ºC).
Using the Remote Control
NOTE: Remote control may differ in appearance.
6. Turn off air conditioner.
7. Press TIMER. Timer indicator light will flash. Display will show
remaining hours before the air conditioner will turn on.
8. Press the plus or minus TEMP button to change the delay
time from 30 minutes to 24 hours.
9. After 5 seconds, Timer indicator light will remain on. Display
will show the current room temperature.
To clear Timer delay program:
NOTE: Air conditioner can be either on or off.
1. Press TIMER once after it has been programmed. Display will
show remaining time.
2. While the display is showing the remaining time, press TIMER
again. Timer indicator light will turn off.
To see or change the remaining time (in hours):
1. Press TIMER once after it has been programmed. Display will
show remaining time.
2. While the display is showing the remaining time, press the
plus or minus TEMP button to increase or decrease the time.
3. After 5 seconds, the display will show the current room
temperature.
Power
NOTE: One CR2025 battery (included) powers the remote
control. Replace battery after 6 months of use, or when the remote control starts to lose power.
Press POWER to turn on air conditioner.
Mode
Press MODE to choose Cool, Dry or Fan.
6th Sense™ System Control
The air conditioner automatically selects Cool or Dry mode, depending on room temperature and sets the temperature to 79ºF (26ºC).
The temperature set point can be adjusted down to 75ºF
(24ºC) or up to 83ºF (28ºC). Press the up or down arrow button once to change the temperature 2ºF (1ºC) or twice to change it 4ºF (2ºC).
If the current room temperature is lower than the temperature
set point, Dry mode is selected. Fan runs on Auto speed only.
If the current room temperature is higher than the
temperature set point, Cool mode is selected. Fan speed may be selected by the user.
th
1. Press 6
Sense™ System control.
2. In Cool mode, press FAN to select High, Med, Low or Auto.
11
RapidCool™ Control
Temperature
Used for fast cooling. The air conditioner automatically sets the fan speed to High and temperature to 64°F (18ºC).
NOTE: 6 RapidCool
th
Sense™ System control button does not operate when
control is selected.
1. Press RapidCool™ control. The air conditioner automatically sets the fan speed to High and temperature to 64°F (18ºC).
2. To turn RapidCool
control off, press the RapidCool control
button, Mode, Fan, Power or the up arrow button.
Fan Speed
Press FAN to choose High, Med, Low or Auto.
NOTE: Auto fan speed cannot be selected in Fan mode.
Sleep Control
NOTES:
If the current room temperature is 80ºF (26ºC) or higher, the
set temperature will not change when Sleep control is activated.
If the current room temperature is below 80ºF (26ºC), the set
temperature will automatically increase 2ºF (1ºC) during the first 2 hours after Sleep control is activated.
The set temperature will not increase during the last 6 hours of Sleep control.
1. Press MODE to select Cool or Dry.
2. Press FAN to select High, Med or Low.
3. Press the up or down arrow button to set the temperature.
4. Press SLEEP. After 10 seconds, the lights on the control
panel display will dim. The mode indicator lights will remain on.
NOTE: The mode, temperature and fan speed may be adjusted during Sleep control. After 10 seconds, the lights on the control panel display will dim again.
5. To turn off Sleep control, press SLEEP again. or wait 8 hours for the air conditioner to turn off automatically.
NOTE: The air conditioner will return to previous settings after Sleep control is turned off.
Press the up arrow button to raise the temperature. Each time
you press or hold the up arrow button, the temperature will go up 2ºF (1ºC) until it reaches 90°F (32°C).
Press the down arrow button to lower the temperature. Each
time you press or hold the down arrow button, the temperature will go down 2ºF (1ºC) until it reaches 64°F (18°C).
Timer
To set Timer for a 30-minute to 24-hour delay before air conditioner is turned off (air conditioner must be On):
1. Press TIMER. Timer indicator light on the air conditioner
control panel will flash.
2. Press up or down arrow button to change the delay time from
30 minutes to 24 hours.
3. After 5 seconds, Timer indicator light on the air conditioner
control panel will remain on.
To set Timer to turn on air conditioner, keeping previous settings:
1. Turn off the air conditioner.
2. Press TIMER. Timer indicator light on the air conditioner
control panel will flash.
3. Press up or down arrow button to change the delay time from
30 minutes to 24 hours.
4. After 5 seconds, Timer indicator light on the air conditioner
control panel will remain on.
To set Timer to turn on air conditioner, changing the previous settings:
1. Turn on air conditioner.
2. Adjust the mode to 6th Sense™ System control, Cool, Dry, Fan
or RapidCool
3. For Cool mode:
Adjust fan speed to High, Med, Low or Auto.
Adjust temperature between 64ºF and 90ºF (18ºC and
32ºC).
control.
12
4. For Fan mode, adjust fan speed to High, Med or Low. NOTE: In Fan mode, temperature cannot be set.
th
5. For 6
Sense™ System control, adjust fan speed to High,
Med, Low or Auto.
6. For Dry mode and 6th Sense™ System control, adjust temperature up or down by 4ºF (2ºC).
7. Turn off air conditioner.
8. Press TIMER. Timer indicator light on the air conditioner
control panel will flash.
9. Press up or down arrow button to change the delay time from 30 minutes to 24 hours.
10. After 5 seconds, Timer indicator light on the air conditioner control panel will remain on.
Starting Your Air Conditioner—Rotary Control
To clear Timer delay program:
NOTE: Air conditioner can be either on or off.
1. Press TIMER once after it has been programmed. Display will
show remaining time.
2. While the display is showing the remaining time, press TIMER
again. Timer indicator light will turn off.
To see or change the remaining time (in hours):
1. Press TIMER once after it has been programmed. Display will
show remaining time.
2. While the display is showing the remaining time, press the
plus or minus TEMP button to increase or decrease the time.
3. After 5 seconds, the display will show the current room
temperature.
Low Fan—for quiet continuous air movement without cooling
Thermostat
1. Select Mode. See “Mode.”
2. Set temperature. See “Thermostat.”
Mode
Set Mode to the desired setting. When the air conditioner is operating, the fan circulates air continuously.
High Coolfor maximum cooling
Med Cool—for normal cooling
Low Coolfor sleeping comfort
High Fan—for maximum continuous air movement without
cooling
Med Fan—for normal continuous air movement without
cooling
Turn the Thermostat control to a mid-setting. Adjust the air conditioner's performance by turning the Thermostat control clockwise for maximum cooling. For less cooling, turn the Thermostat control counterclockwise. Experiment to find the setting that suits you best.
Changing Air Direction
Use wheel to direct the air right or left. Use the whole cartridge to direct air up, down or straight ahead.
A
A
A. Wheel
A. Cartridge
13
Exhaust Air Vent
Pull out the exhaust air vent control to Open the exhaust air
vent and draw stale or smoky air from the room.
Push in the exhaust air vent control to close the exhaust air
vent for maximum continuous cooling.
A
A. Exhaust air vent control
NOTE: The exhaust air vent control will function only when the Fan Speed control is operating.
When your air conditioner is operating normally, you may hear sounds such as:
Droplets of water hitting the condenser, causing a pinging or
clicking sound. The water droplets help cool the condenser.
Air movement from the fan.
Clicks from the thermostat cycle.
Vibrations or noise due to poor wall or window construction.
A high-pitched hum or pulsating noise caused by the modern
high-efficiency compressor cycling on and off.
Normal Sounds
AIR CONDITIONER CARE
Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly. Call your local authorized dealer for an annual checkup. Remember… the cost of this service call is your responsibility.
3. Use a vacuum cleaner to clean air filter. If the air filter is very
Cleaning the Air Filter
The air filter is removable for easy cleaning. A clean filter helps remove dust, lint, and other particles from the air and is important for best cooling and operating efficiency. Check the filter every 2 weeks to see whether it needs cleaning.
NOTE: Do not operate the air conditioner without the filter in place.
1. Turn off the air conditioner.
2. Remove the air filter by sliding the air filter from either side of
the front panel.
dirty, wash it in warm water with a mild detergent. Do not wash the air filter in the dishwasher or use any chemical cleaners. Air dry the air filter completely before replacing to ensure maximum efficiency.
4. Replace the air filter by sliding the air filter back in on either
side of the front panel.
Cleaning the Front Panel
1. Turn off the air conditioner.
2. Clean the front panel with a soft, damp cloth.
3. Air dry the front panel completely.
Repairing Paint Damage
Check once or twice a year for paint damage. This is very important, especially in areas near oceans or where rust is a problem. If needed, touch up with a good grade enamel paint.
Annual Maintenance
Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call your local authorized dealer to schedule an annual checkup. The expense of an annual inspection is your responsibility.
14
TROUBLESHOOTING
Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.
Air conditioner will not operate
WARNING
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
The power supply cord is unplugged. Plug into a grounded
3 prong outlet. See “Electrical Requirements.”
The power supply cord has tripped (Reset button has
popped out). Press and release RESET (listen for click; Reset button will latch and on some devices, a green light will turn on) to resume operation.
A household fuse has blown, or circuit breaker has
tripped. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician. See “Electrical Requirements.”
The Power button has not been pressed or the Mode
control knob is turned to Off. Press POWER or turn the Mode control knob to an active setting.
The local power has failed. Wait for power to be restored.
Air conditioner blows fuses or trips circuit breakers
Too many appliances are being used on the same circuit.
Unplug or relocate appliances that share the same circuit.
Time-delay fuse or circuit breaker of the wrong capacity
is being used. Replace with a time-delay fuse or circuit breaker of the correct capacity. See “Electrical Requirements.”
An extension cord is being used. Do not use an extension
cord with this or any other appliance.
You are trying to restart the air conditioner too soon after
turning off the air conditioner. Wait at least 3 minutes after turning off the air conditioner before trying to restart the air conditioner.
Air conditioner power supply cord trips (Reset button pops out)
Disturbances in your electrical current can trip (Reset
button will pop out) the power supply cord. Press and release RESET (listen for click; Reset button will latch and on some devices, a green light will turn on) to resume operation.
Electrical overloading, overheating, cord pinching or
aging can trip (Reset button will pop out) the power supply cord. After correcting the problem, press and release
RESET (listen for click; Reset button will latch and on some devices, a green light will turn on) to resume operation.
NOTE: A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.
Air conditioner seems to run too much
The current air conditioner replaced an older model. The
use of more efficient components may cause the air conditioner to run longer than an older model, but the total energy consumption will be less. Newer air conditioners do not emit the “blast” of cold air you may be accustomed to from older air conditioners, but this is not an indication of lesser cooling capacity or efficiency. Refer to the efficiency rating (EER) and capacity rating (in Btu/h) marked on the air conditioner.
The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room. Use exhaust vent fans while cooking or bathing and try not to use heat­producing appliances during the hottest part of the day. A higher capacity air conditioner may be required, depending on the size of the room being cooled.
Air conditioner cycles on and off too much or does not cool room in cooling mode
The air conditioner is not properly sized for your room.
Check the cooling capabilities of your room air conditioner. Room air conditioners are not designed to cool multiple rooms.
The filter is dirty or obstructed by debris. Clean the filter.
The inside evaporator and outside condenser coils are
dirty or obstructed by debris. See “Annual Maintenance.”
There is excessive heat or moisture (open container
cooking, showers, etc.) in the room. Use a fan to exhaust heat or moisture from the room. Try not to use heat­producing appliances during the hottest part of the day.
The louvers are blocked. Install the air conditioner in a
location where the louvers are free from curtains, blinds, furniture, etc.
15
Loading...
+ 33 hidden pages