Failure to follow these
instructions may result in product damage,
equipment damage, and serious or fatal
injury to personnel.
Introduction
Warner Electric's CBC-700 clutch/brake
control is a basic overexcitation control for
electromagnetic clutches and brakes.
Overexcitation, a momentary high voltage spike,
builds up electromagnetic flux very quickly in
the clutch and/or brake coil for quick
engagement and superior accuracy. The
CBC-700 works on the capacitive discharge
principle, boosting AC input voltage and storing
a high voltage pulse. No torque adjustment is
provided, so full torque is available from the
"on" clutch (or brake) by providing it with full
rated voltage. Two models of the CBC-700 are
available:
CBC-700-9090 volt magnets
CBC-700-2424 volt magnets
The CBC-700 requires only two adjustments.
Overexcitation pulse duration is adjustable in
seven ranges to custom tailor control function
for each application and to minimize coil
temperatures. A time delay between
clutch/brake engagement is also adjustable
between 0 and 100 milliseconds for the
CBC-700-90, and 0 to 50 milliseconds for the
CBC-700-24, by providing a rest period
between brake and clutch engagement. This
eliminates overlap and reduces heating and
wear of the clutch and brake units.
The CBC-700's sophisticated coil suppression
circuitry allows extremely short time delays and
quick response. Optically isolated switching
inputs promote full switching flexibility.
The CBC-700-90 incorporates several new
features:
A short circuit protection for the clutch and
brake outputs. If a short is present, an amber
L.E.D. will illuminate and the outputs will be
isabled. The short circuit L.E.D. is reset by
turning off the power to the control for 10
seconds.
• An O.E.X. on/off switch allows the user to
turn off the O.E.X. pulse for custom
applications.
• Two output L.E.D.s indicate when the brake
(red) or clutch (green) is on.
Note: CBC-700-90C has a right angle terminal strip and is conformally coated.
Warner Electric • 800-234-3369P-272A • 819-0527
3
Page 4
Installation
4.50 (114.3)
1.85
(47)
2.50 (63.5)
5.00
(127)
3.25
(82.5)
4.65
(118.1)
0.125R, TYP
(3.2)
0.50
(12.7)
0.50
(12.7)
6 PLS
0.20 (5.1)
0.95
(24)
0.100 R, TYP
(2.54)
CBC-700-90: 120 VAC
CBC-700-24: 24 VAC
AuxiliaryC
Supply
(12V)
Brake
Input
(10-30 VDC)
Clutch
Input
(10-30 VDC)
(Ch.1)
Brake
Ch.2
Clutch
1
2345
6
78
9
10
11
+
+
+
-
-
-
2-Wire
10-30 VDC*
Open: Brake
Closed: Clutch
3-Wire
10-30 VDC*
10-30 VDC*
+
+
--
56 7
8
3
45
6
7
8
+
-
Sensor
NPN
Brake/Stop Input From Sensor (NPN)
Powered From Auxiliary Supley
4
Output
Clutch/Start Input
Through External
Momentary Contact
1
11
23
4
5
67
89
10
®
DIST. AUTORIZADO
MEX(55) 53 63 23 31QRO (442) 1 95 72 60
MTY (81) 83 54 10 18ventas@industrialmagza.com
The voltages in this control can cause serious injury (even death). When installing
or wiring this control, make sure the input power is off, and main capacitors discharged. Do not
apply voltage to the control until it is securely mounted and completely wired in accordance with
local codes and all installation work, including cleanup, has been completed.
Connection Diagram
Switching Options
The control may be operated in either 2-wire (level) or 3-wire (pulse) mode.
2-Wire
3-Wire
*Input voltage can be customer supplied or furnished by the 12 VDC auxiliary supply.
Example
Below is an example of a common approach using an external contact closure for the start signal
and a sensor to initiate braking.
Dimensional Diagram
The control may be mounted on its base (two mounting slots) or on its back (for mounting slots). All
dimensions are nominal.
This is a floating-type control and is not referenced to AC ground. Under no circumstances should any of
the output wire leads be connected to earth or chassis ground
as the unit will be destroyed.
*For the units with a shuttle armature, the
overlap setting should be zero (0).
Control Adjustments
The duration of the OEX Pulse and Anti-Overlap Time Delay can be optimized to a specific clutch/
brake. The chart above designates switch settings for 90 and 24 VDC Warner Electric clutch/brake
models.
OEX Duration Settings
Warner Electric • 800-234-3369P-272A • 819-0527
Anti-Overlap Time Delay
Potentiometer PI
1000
5
Page 6
Template for Mounting CBC-700
®
DIST. AUTORIZADO
MEX(55) 53 63 23 31QRO (442) 1 95 72 60
MTY (81) 83 54 10 18ventas@industrialmagza.com
Base Mount
Warner Electric • 800-234-3369P-272A • 819-0527
6
Wall Mount
Page 7
System Troubleshooting
®
DIST. AUTORIZADO
MEX(55) 53 63 23 31QRO (442) 1 95 72 60
MTY (81) 83 54 10 18ventas@industrialmagza.com
The chart below will be helpful when attempting to isolate problems which may occur in the control
system. It will also prove helpful when encountering problems during initial system start-up.
Symptom A: No output on either clutch or brake upon power-up.
Probable CauseSolution
Improper wiringCheck wiring and correct if necessary.
No power availableCheck that AC power is available to control.
Blown fuse* See Fuse keeps blowing, Symptom C.
Faulty controlReplace control.
Symptom B: Clutch activates upon power-up.
Probable CauseSolution
Improper wiringCheck wiring and correct if necessary.
Faulty input switching circuitCheck that input switching network is providing proper signal.
Symptom C: Fuse keeps blowing.
Probable CauseSolution
Improper wiringCheck wiring and replace fuse.
Shorted brake/clutch coilCheck coil resistance and replace if necessary.
Ground FaultCheck coil to earth ground resistance.
Improper AC line voltageCheck line voltage and correct if necessary.
Improper magnet voltageCheck magnet voltage rating and replace with correct magnet if necessary.
Symptom D: Magnets do not appear to have enough torque.
Probable CauseSolution
Improper OEX switch settingSet pulse duration switch settings according to setup chart.
Magnets incorrectly sizedVerify sizing by repeating the selection process.
Incorrectly wired inputsCheck wiring and correct if necessary.
Faulty switching deviceCheck for proper operation and replace if defective.
Faulty controlReplace control.
Symptom F: Switching time too long or too short.
Probable CauseSolution
Improper overlap pot settingSet overlap according to setup chart.
Symptom G: Amber L.E.D. illuminated *
Probable CauseSolution
Improper wiringCheck wiring and correct if necessary.
Shorted brake/clutch coilCheck coil resistance and replace if necessary.
Faulty controlReplace control.
* Turn off power to control for 10 seconds to turn off amber L.E.D.
Warner Electric • 800-234-3369P-272A • 819-0527
7
Page 8
Warranty
®
DIST. AUTORIZADO
MEX(55) 53 63 23 31QRO (442) 1 95 72 60
MTY (81) 83 54 10 18ventas@industrialmagza.com
Warner Electric LLC warrants that it will repair or replace (whichever it deems advisable) any product
manufactured and sold by it which proves to be defective in material or workmanship within a period of
one (1) year from the date of original purchase for consumer, commercial or industrial use.
This warranty extends only to the original purchaser and is not transferable or assignable without Warner
Electric LLC’s prior consent.
Warranty service can be obtained in the U.S.A. by returning any defective product, transportation charges
prepaid, to the appropriate Warner Electric LLC factory. Additional warranty information may be obtained
by writing the Customer Satisfaction Department, Warner Electric LLC, 449 Gardner Street, South Beloit,
Illinois 61080, or by calling 815-389-3771.
A purchase receipt or other proof of original purchase will be required before warranty service is rendered.
If found defective under the terms of this warranty, repair or replacement will be made, without charge,
together with a refund for transportation costs. If found not to be defective, you will be notified and, with
your consent, the item will be repaired or replaced and returned to you at your expense.
This warranty covers normal use and does not cover damage or defect which results from alteration,
accident, neglect, or improper installation, operation, or maintenance.
Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not
apply to you.
Warner Electric LLC’s obligation under this warranty is limited to the repair or replacement of the
defective product and in no event shall Warner Electric LLC be liable for consequential, indirect, or
incidental damages of any kind incurred by reason of the manufacture, sale or use of any defective
product. Warner Electric LLC neither assumes nor authorizes any other person to give any other warranty
or to assume any other obligation or liability on its behalf.
WITH RESPECT TO CONSUMER USE OF THE PRODUCT, ANY IMPLIED WARRANTIES WHICH THE
CONSUMER MAY HAVE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL
CONSUMER PURCHASE. WITH RESPECT TO COMMERCIAL AND INDUSTRIAL USES OF THE
PRODUCT, THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES,
WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING, BUT NOT
LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also
have other rights which vary from state to state.
Changes in Dimensions and Specifications
All dimensions and specifications shown in Warner Electric catalogs are subject to change without notice.
Weights do not include weight of boxing for shipment. Certified prints will be furnished without charge on
request to Warner Electric.
P-272A • 819-0527 6/08Printed in USA
Warner Electric LLC
449 Gardner Street • South Beloit, IL 61080
815-389-3771 • Fax: 815-389-2582
www.warnerelectric.com
An Altra Industrial Motion Company
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.