VOLTCRAFT Three-phase adapter Operation Manual

Three-phase adapter
References marked on adapter or in instruction manual
:
Warning of a potential danger, comply with instruction manual.
Reference. Please use utmost attention.
Caution! Dangerous voltage. Danger of electrica l shock.
Equipment protected throughout by double insulation or
reinforced insulation.
Conformity symbol, the adapter complies with the valid directives. It complies with the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) with their valid standards.
The instruction manual contains information and refe­rences, necessary for safe operation and maintenance of the adapter.
kindly requested to thoroughly read the instruction ma­nual and comply with it in all sections.
Failure to read the instruction manual or to comply with the warnings and references contained herein can re- sult in serious bodily injury or adapter damage.
1.0 Introduction
You have purchased a high quality product of Ch. BEHA GmbH wich will allow you to carryout measurement over a long time period.
• For measurement of Low-Ohm, Insulation resistance, line re­sistance, loop resistance, RCD trip time-/ current and rotary field.
• Connection via five separate 4-mm sockets for L1, L2, L3, N and P E
• For use for all test adapters with 4-mm plugsystems.
1.1 Model and Type Designation
The type shield sticker is located on the rear of the adapter. When questions arise regarding the adapter, please always quote product designation.
Prior to using the adapter the user is
1.2 Productdescription
The measurement adapter is an universal adapter for use in combination with installation testers which enables to check three phase plugs.
1.3 Scope of Supply
1 pc. measurement adapter
2.0 Transport and Storage
In the case of an adapter being transported in extreme tempe­ratures, a recovery time of minimum 2 hours is required prior to adapter operation.
3.0 Safety
The measurement adaptor has been manufactured and tested to comply with the safety regulations and left our works in a safe condition.To maintain this condition, the user must ob­serve the safety instructions contained in this instruction ma­nual.
The respective accident prevention regulations establis­hed by the professional associations for electrical sys­tems and equipment must be strictly met at all times. In order to avoid electrical shock, the valid safety and na­tional regulations regarding excessive contact voltages must receive utmost attention, when working with volta­ges exceeding 120V (60V) DC or 50V (25V)rms AC. The values in brackets are valid for limited ranges (as for example medicine and agriculture). Measurements in dangerous proximity of electrical instal­lations are only to be executed when instructed by a re­sponsible electrical specialist, and never alone. Before each measurement make sure that the test leads and the adapter are undamaged.
The measurement adapter contains no fuses. The overlo­ad protection must be provided by the upstream con­nected over current device.
The measurement adapter must be used for measure­ment purposes only, and is not allowed be used for conti­nuous measurements. It must be used in the ranges as described in the technical data section.
If the operator’s safety is no longer ensured, the adapter is to be put out of service and protected against use. The safety is no longer insured, if the adapter:
• shows obvious damage
• does not carry out the desired measurements
• has been stored for too long under unfavourable condi­tions
• has been subjected to mechanical stress during trans­port.
Avoid any heating up of the adapter by direct sunlight to ensure perfect functioning and long adapter life.
3.1 Appropriate Usage
The adapter may only be used under those conditions and for those purposes for which it was conceived. For this reason, in particular the safety references, the techni­cal data including environmental conditions and the usage in dry environments must be followed.
When modifying or changing the adapter, the operational safety is no longer ensured. The adapter may only be opened by an authorised ser­vice technician.
3.2 Measurement using the three-phase current adapter Low ohm measurement
made from PE connector against the equipotential bonding or other conductible parts within a system. It is, of course, possi­ble to directly test the connection between N and PE.
Insulation resistance measurement
between all active conductors (L1, L2, L3, and N) against PE. Additionally, the measurement of all active conductors to­wards each other is required according to some regulations. The mains voltage must be switched off!
Line resistance
measurement (L1, L2, or L3) against N. Attention, for safety testing, PE must be connected for some test adapters!
Loop resistance/ impedance
(L1, L2, or L3) against PE. Attention, for safety testing, N must be connected at some test adapters!
RCD trip time/ trip current
L2, or L3) towards N and PE. Imperatively connect N and PE. Test adapters without probe perform contact voltage measure- ment!
Rotary field
PE are not required for this application.
Technical Data
for 16A adapter: 230V/400V max. 4A, CATIII 300V for 32A adapter: 230V/400V max. 4A, CATIII 300V
: for this, connect phase (L1, L2, and L3). N and
:
: for this application, measurement is
: measurement is made
: measured from the external conductor under
: also measured from the phase
: measured from the phase (L1,
4.0 Connections A) Socket connections (4 mm)
L1, L2, L3, N, PE
B) CEE-plug 5-poles
24 month Warranty
The products are subject to strict quality control. However, should the adapter function improperly during daily use, your are protected by our 24 months warranty (valid only with in­voice). We will repair free of charge any defects in workman­ship or material, provided the adapter is returned unopened. We will repair free of charge any defects in workmanship or material, provided the adapter is returned unopened and un­tampered with, i.e. with undamaged warranty label. Any da­mage due to dropping or incorrect handling are not covered by the warranty. If the adapter shows failure following expira- tion of warranty, our service department can offer you a quick and economical repair.