Viking VGIC53024BBU Manual

0 (0)
Installation
Professional Freestanding Open Burner Ranges
VGIC5301 VGIC5361
2
Table of Contents
Warnings & Important Safety Instructions ____________________________________________ 3
Dimensions________________________________________________________________________ 6
Specifications ______________________________________________________________________8
Clearance Dimensions (Wood/Composite Overlay) ____________________________________10
Electrical & Gas Requirements______________________________________________________ 11
General Information ______________________________________________________________ 13
Installation ______________________________________________________________________ 14
Door Removal ______________________________________________________________ 14
Leg Installation ______________________________________________________________ 15
Leveling/Adjustments/Alignment ______________________________________________ 16
Anit-tip Device Installation
Wall Mount ______________________________________________________________17
Connecting Gas & Electrical __________________________________________________ 19
Final Installation ____________________________________________________________ 20
Door Replacement and Adjustment ____________________________________________ 21
Final Preparation__________________________________________________________________ 22
Performance Checklist ____________________________________________________________22
Service & Registration ____________________________________________________________ 23
IMPORTANT–Read and Follow!
3
• Before beginning, please read these instructions completely and carefully.
DO NOT remove permanently affixed labels, warnings, or plates from product. This may void the warranty.
• All local and national codes and ordinances must be observed. Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSI Z223.1 INFPA54.
• The installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
In Canada: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.
In Massachusetts: All gas products must be installed by a “Massachusetts” licensed plumber or gasfitter. A “T” type handle manual valve must be installed in the gas supply line to the appliance.
An air curtain or other overhead range hood which operates by blowing a downward airflow onto the range, shall not be used with a gas range
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER,” “WARNING” or “CAUTION.” These words mean:
Hazards or unsafe practices
which WILL result in severe personal
injury or death
DANGER
Hazards or unsafe practices
which COULD result in severe personal injury
or death
Hazards or unsafe practices which COULD
result in minor personal injury or property
damage.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
WARNING
CAUTION
IMPORTANT–Read and Follow!
4
DANGER
FIRE/EXPLOSION HAZARD
IF THE INFORMATION IN
THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
• DO NOT store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
–DO NOT try to light any appliance. –DO NOT touch any electrical switch;
DO NOT use any phone in your building.
–Immediately call your gas supplier from
a neighbor’s phone. –Follow the gas supplier’s instructions. –If you cannot reach your gas supplier,
call the fire department.
• Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
WARNING
To prevent possible damage to cabinets and cabinet finishes, use only materials and finishes that will not discolor or delaminate and will withstand temperatures up to 194°F (90°C). Heat resistant adhesive must be used if the product is to be installed in laminated cabinetry. Check with your builder or cabinet supplier to make sure that the materials meet these requirements.
A GFI
shall be used if required by NFPA-70 (National Electric Code), federal/state/local
laws, or local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.
• Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
5
DANGER
GAS LEAK HAZARD
To avoid risk of personal injury or death; leak testing of the
appliance must be conducted according to the manufacturer’s instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution.
• DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.
DANGER
ELECTRICAL SHOCK HAZARD
To avoid risk of electrical shock,
personal injury or death; verify your appliance has been properly grounded in accordance with local codes or in absence of codes, with the National Electrical Code (NEC). ANSI/NFPA 70­latest edition.
WARNING
MOVING HAZARD
To avoid risk of severe personal injury; this appliance
requires two or more personnel while handling and moving. Possible use of appliance moving devices is recommended.
DANGER
CHEMICAL HAZARD
To avoid risk of property damage and/or personal injury or death; this appliance is not
too be used as a heating source.
• Benzene is a chemical which is part of the gas supply to this cooking product, which is consumed in the flames during combustion. Exposure to a small amount of benzene is possible if a gas leak occurs. Formaldehyde and soot are by­products of incomplete combustion.
• This appliance contains or produces chemicals which can cause serious injury or death and which are known to the state of California to cause cancer, birth defects or other reproductive harm. To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed, operated, and maintained in accordance to the instructions in this document.
WARNING
TIPPING HAZARD
To reduce the risk of property damage or personal injury; install anti-tipping device provided in accordance with the installation instructions in this document. Device must be engaged properly to prevent product from tipping over.
• This range can tip.
• Injuries to persons can result.
• Install anti-tip device packed with range.
• See installation instructions.
Dimensions
6
35-7/8”
(91.1 cm) min.
to
37”
(94.0 cm) max.
1”
(2.5 cm)
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
Gas 30 and 36” W. Ranges
Note: Unit shown with standard island trim.
Dimensions
7
Gas 30 and 36 W. Ranges
Note: Unit shown with standard island trim.
8-1/8”
(20.6 cm)
28-1/16” (71.2 cm)
1-5/8”
(4.1 cm)
26-7/16” (67.2 cm)
1” (2.5 cm)
19-3/8”
(49.2 cm)
35-7/8”
(91.1 cm) min.
to
37”
(94.0 cm) max.
25-3/4” (65.4 cm)
45-1/8” (114.6 cm)
24-5/16” (61.8 cm)
Specifications
8
Minimum clearances from adjacent combustible construction: Below cooking surface (36” [91.4 cm] and below)
• Sides - 0”
• Top grate support - 36” (91.4 cm)
Above cooking surface (above 36” [91.4 cm])
• Sides - 6” (15.2 cm)
• Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm) above cooking surface
• Wall cabinets directly above product must be a minimum of 42” (106.7 cm) above cooking surface
• Rear - 0” with 8” backguard or high shelf; 0” with island trim and non-combustible rear wall;
• 6” (15.2 cm) with island trim and combustible rear wall
Gas 30 and 36” W. Ranges
Description
30 W. Models 36 W. Models
Overall width 29-7/8” (75.9 cm) 35-7/8” (91.1 cm)
Overall height To top of side trim - 35-7/8” (91.1 cm) min. 37” (94.0 cm) max.
Legs adjust - 1-1/8” (2.9 cm)
Overall depth from rear*
To end of side panel - 24-5/16” (61.8 cm)
To front of door - 25-3/4” (65.4 cm)
To end of landing ledge - 28-1/16” (71.2 cm)
To end of door handle - 28-11/16” (72.9 cm)
*Add 1” to overall depth for ranges with backguards installed against a combustible wall.
Additions to Base Height
To top of island trim - add 1” (2.5 cm)
To top of backguard - add 8” (20.3 cm)
To top of high shelf - add 23-1/2” (59.7 cm)
Gas Requirements Shipped Natural or LP/Propane, field convert with conversion kit (purchased separately);
accepts standard residential 1/2” (1.3 cm) ID gas service line
Gas Manifold Pressure Natural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.
Electrical Requirements 120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded
3-prong plug attached to unit
Max Amp Usage
.83 amps 1.5 amps
Surface Burner Rating Natural/LP
15,000 BTU (4.4 kW)/12,500 BTU (3.7 kW)
Broil Burner Rating Natural/LP
18,000 BTU (5.3 kW)/16,000 BTU (4.7 kW)
Oven Burner Rating Natural/LP
30,000 BTU (8.8 kW) Nat./LP
Oven(s) Interior Width 23” (58.4 cm) 29” (73.7 cm)
Oven(s) Interior Height 16-1/8” (40.9 cm)
Oven(s) Interior Depth Overall - 18-3/4” (47.6 cm)
Oven(s) Volume Overall AHAM
4.0 cu. ft.
3.7 cu. ft.
5.1 cu. ft.
4.6 cu. ft.
Approximate shipping weight
410 lbs.
(184.5 kg)
500 lbs. (225 kg)
Loading...
+ 16 hidden pages