RACKMOUNT POWER MADE EASY
• Compact UPS system with intuitive control panel
• Optimized modules minimize space used in the rack
• Easily configurable
Shown here is the Liebert ITA2 UPS with (2) battery cabinets.
Vertiv™ Liebert® ITA2 UPS
8 and 10 kVA, 208/220V Three-Phase
The Small Three-Phase UPS Solution
Overview
The Vertiv™ Liebert® ITA2 is an online
UPS designed to power three-phase
(in/out), 208/220V IT systems simply,
reliably, and economically.
For three-phase critical systems under 10kVA, consider the Vertiv Liebert ITA2 UPS. It
stabilizes power to protect systems and data. Professionals can define the feature set
they need to meet their IT performance goals.
Rackmount power made easy
Key Benefits
y Flexible placement. Use inside a
rack or in a tower configuration
y Compact, high power density
y Easy to install and manage
y High power factor maximizes the
usable power
y Operates eiciently to save
energy
y Optimized maintenance bypass
maintains power, even during
servicing (optional)
y Extended battery runtimes
(optional)
y Flexible, easy to configure
power distribution
Ideally Suited For Powering
Many IT Systems
y IT closets, servers and more
y Branch, small-midsize
IT systems
y Medical/lab testing equipment
y VoIP
y Compact UPS system with intuitive control panel
y Optimized modules minimize space used in the rack
y Easily configurable
Shown here is the Liebert® ITA2 with
(2) battery cabinets
Vertical/Tower Placement
y Support base provides convenient and stable
placement on a floor
y Adjustable display panel ensures readable and
ease of use
y Configuration easily extends to batteries and the
maintenance bypass cabinet
Shown here is the UPS and battery cabinets in a tower management
Flexible, Reliable and Functional
The Vertiv Liebert ITA2 oers a space-saving design to meet your power needs. Options
are available to address specific runtimes, distribution and availability requirements.
y ISDN & frame relay applications
y Storage systems
y Security systems
y Light industrial
y Replacement for aging UPS
Save Now, Save Later.
Compared to Competitive Models.
y Lower first costs
y Reduce operating costs
y Minimize downtime costs
y Lower TCO
Protect Critical IT Systems From All
Key Electrical Threats
Outages
Transient
Sags
Frequency
Deviation
Surges
Under-
Voltage
Spikes
Over-
Voltage
Noise
Harmonics
1
Vertiv™ Liebert® ITA2 UPS
More of What You Need: High Power Density
The Vertiv™ Liebert® ITA2 is designed with a high power factor in a small footprint. This increased power density maximizes the usable
power to meet the needs of advanced IT operations.
Get Up to 10% More Power
kW
Liebert®
Liebert
ITA2 UPS
ITA2 UPS
Brand E
UPS
Battery Cabinet
Maintenance Bypass Cabinet Enables Availability and Flexibility
Utilize the optimized maintenance bypass option to enhance availability and keep your critical systems running during routine service
or replacement. A maintenance bypass interlock ensures proper bypass operation.
Front view (panel o) oers easy access to breakers Rear view with I/O connections and Power Output
Distribution options (hardwire and/or PODs)
Power Distribution: Easier, Faster, Less Costly Deployment
Fast, flexible and easy to deploy power output distribution options can be quickly matched for specific power requirements.
Hardwired is standard, with several integrated options to obtain convenient receptacle connectivity.
Distribution Option Qty Of Receptacles Part Number
Hardwire -
L21-30R 2 PD3-001
L21-20R 2 PD3-009
L6-30R 6 PD3-002
L6-20R 6 PD3-006
L5-30R 6 PD3-003
L5-20R 6 PD3-005
L15-30R 6 PD3-007
L15-20R 6 PD3-010
CS8364C 1 PD3-008
IEC60309 3W+G 1 PD3-004
IEC60309 4W+G
1
Mix and match POD assemblies to power dierent loads. Refer to your Rack PDU for details.
2
Does Not Apply
PD3-011