1. INSTALLATION
The unit is intended to be mounted on a Wall Mount. Installation of the pan and tilt drive to the wall mount requires a stainless steel 1/4-20 screw supplied with the wall mount. Note the ribs on the underside of the unit base engage slots in the mount. This allows positioning of the unit in any of four directions with respect to the wall mount. Secure unit to the wall mount using screw from underside of wall mount into unit and tighten.
2. WIRING OF UNIT
Fabricate the interconnecting cable in accordance with Figure 1. for proper operation.
3. INVERTED MOUNTING
When the unit is mounted in the inverted position, the left-right directions are reversed for manual operation. This must be corrected when wiring the cable between control unit and the pan and tilt drive. Simply reverse leads going to terminals 3 and 4.
4. ADJUSTING LIMIT STOPS
After cable is installed and unit has been mounted, proceed as follow :
1. Plug control unit into AC 24V source. Be sure auto switch is in the OFF position.
POWER (red) COMMON (black) TILT DOWN (yellow) TILT UP (blue) PAN RIGHT (gr een ) PAN LEFT (white)
Figure 1
Cable Assembly Diagram
VSCP1-VISP1 VELLEMAN
1
2. To adjust pan limit stops (see Figure 2), loosen screws securing both stops (1) and (3) to unit. Slide stops around unit to desired locations and secure by tightening screws.
3. To adjust tilt limit stops (see Figure 2) located in each end plate, remove two screws securing each end cap to unit. Loosen and adjust tilt limit stop screws for desired tilt limit position. Tighten limit stop screws and reinstall each end caps to unit and secure with two screws.
Figure 2
Limit Stop Adjustment and Camera Mounting Plate