Velleman PI600M, PI60024 User Manual

Page 1
DC TO AC POWER INVERTER
POWER : 600W
PI600M PI60024
for input voltage 12V for input voltage 24V
ATTENTION – OPGELET - ACHTUNG
OVERLOADING THIS DEVICE OR CONNECTING IT WITH AN IN DUCTIVE LOAD (e.g. refriger ator, fan, drill) WILL DAMAGE IT AND AUTOMATICALLY VOID THE WARRANTY !!
HET TOESTEL ZAL WORDEN BESCHADIGD INDIEN U HET OVERBELAST OF ER EEN INDUCTIEVE BELASTING (vb. koelkast, boormachine, ventilator) OP AANSLUIT. DE GARANTIE VERVALT DAN AUTOMATISCH !!
LA SURCHARGE DE L’APPAREIL OU LA CONNEXION D’UNE CHARGE INDUCTIVE (p.ex. vent ilat eu r, réfrigérateur, perceuse) ENDOMMAGERONT L’APPAREIL ET LA GARANTIE SERA INVALIDEE AUTOMATIQUEMENT !!
DIE GARANTIE ERLISCHT UND DER SPANNUNGSWANDLER KANN BESCHÄDIGT WERDEN, WENN SIE IHN ÜBERL ASTEN ODER MIT EINER INDUKTIVEN LAST VERBINDEN (z.B. Kühlschrank, Lüfter, Bohrmaschine).
User Manual Gebruikershandleiding Manuel d'utilisation Bedienungsanleitung
Page 2
1. DESCRIPTION
voltage
indicator
power
switch
crocodile
clips
AC output
socket
2. CONNECTIONS Connect the red cable from the "+" terminal (red term inal ) of the battery to the +
binding post (red connection) of the inverter and the black c able from the "-" terminal (black terminal) of the battery to the "-" binding post (black connection) of the inverter. The length of the cable is 2m.
Be sure to tighten the screws in order to avoid loos e con necti on.
3. OPERATION When connected to an appliance, remember to turn on the inverter before turning
on the appliance. If the buzzer sounds during operation, this indicates that the battery voltage is very low and that the inverter will be disconnected in 5 minutes.
then the
device
Switch on
inverter
PI600M & PI60024 v2 GB 1
Page 3
4. OUTPUT CAPACITY The inverter will switch off automatically if the total wattage of the electrical
appliances exceeds the inverter's output capacity. This will also happen if the temperature of the inverter exceeds 55°C due to prolonged use.
5. SPECIAL RECOMMENDATIONS Unplug the AC inverter when not in use and when starting the vehicle's motor. If the AC inverter makes a beeping sound : switch off your appliance, unplug the
inverter and restart your vehicle's engine. The beeping sound is simply the low­battery warning, which indicates that the voltage of your battery is getting low. Your inverter will shut down automatically if you do not restart your engine and continue the use of your inverter. This will leave your vehicle's battery at about
10.5VDC (21VDC when using a 24V inverter), enabling you to start your engine and resume operation of the inverter. It also eliminates the possibil ity of being stranded with a dead battery.
To avoid over-discharging the battery, you should let your engine run for 10 to 20 minutes after every 2-3 hours of use. This allows your vehicle's battery to recharge.
Please remember to connect the "+" wire to the "+" terminal and the "-" wire to the "-" terminal if you choose to use an adapter in order to establis h a di rect connection between the AC inverter and the battery terminals. IF YOU CONNECT THE WIRES TO INCORRECT TERMI NALS, THE POLARITY WILL BE REVERSED AND THIS WILL DAM AGE THE INVERTER. REVERSED POLARITY WILL INSTANTLY VOID YOUR INVERTER'S WARRANTY.
Please remember to disconnect the AC inverter before using the battery charger to replenish you battery's voltage. Failure to disconnect the inverter prior to connecting a charger may result in an input spike that will damage the inverter. CONNECTING THE INVERTER'S INPUT TO A BATTERY CHARGER WILL VOID THE WARRANTY AND MAY DAMAGE THE INVERTER
The battery's voltage must never exceed 15VDC (30 VDC for a 24V inverter). CONNECTING THE INVERTER TO A DC POW ER SOURCE GREATER THAN 15VDC (30VDC) WILL VOID THE WARRANTY AND MAY DAMAGE THE INVERTER.
PI600M & PI60024 v2 GB 2
Page 4
6. ADDING EXTENSION CO RDS We recommend that the buyer refrain from using an extension cord between the
DC power source and the inverter's DC input. Connecting an extension cord to the DC input will create a voltage drop, entailing reduced efficiency and output. Instead, we recommend the use of an extension cord between the AC output and the AC appliance. You may use up to 100ft (30m) of high quality extension cord. A longer cord may result in reduced power.
7. EARTHING CONNECTION
WARNING : YOU MUST PROVIDE THE INVE RTER WITH AN EARTHING CONNECTION BEFORE USING THE INVERTER.
The rear panel of the inverter is equipped with a terminal fitted with a wing nut. This terminal is connected to the case of the inverter and also to the ea rthi ng terminal of the AC output socket. The nature of your installation will determine whether or not you need this terminal. Always use heavy-duty yellow and green wiring for this connection.
In a stationary land-based installation, the earthing terminal should be connected to a metal earthing stake driven into the ground to a minimum depth of 1.2m. One of the battery terminals (preferably the negative one) should also be connected to the earthing stake if the battery system powering the inverter is not equipped with a ground connection.
If the inverter is used in a vehicle, where it is wired directly to the battery, the earthing terminal is simply connected to the chassis. If, however, the inverter has to power equipment used outside the vehicle, an earthing s t ake should be used as described above.
Connect the earthing terminal to the existing grounding system when the inverter is used on a boat.
NOTE : The earthing terminal of the AC outlet is connected to the neutral
terminal. This is the same as with a standard household po wer point where the neutral connection is bonded to earth and there is no voltage between the two.
PI600M & PI60024 v2 GB 3
Page 5
8. FUSE Please check the fuse if the voltage indicator is not lit during operation. Replace
blown fuses with an identical one. FUSE : max. 35A for a 12V inverter or 20A for a 24V inverter.
9. MEASURING AC VOLTAGES The output wave of the AC inverter is a MODIFIED SINEWAVE. If you choose to
measure the AC output voltage, you must use an AUTHENTIC RMS VOLT METER. Using any other type of voltage measuring device will result in an AC voltage reading that is up to 20 to 30 volts lower than the rated value. The reading will only be accurate when using an authentic RMS voltmeter.
10. VENTILATION IMPORTANT ! During operation, make sure the fan keeps revolving. Check the
inverter for possible malfunctions if the fan does not work when this unit is being used.
Make sure the fan is not blocked in order to avoid poor ventilation.
BAD
GOOD
PI600M & PI60024 v2 GB 4
Page 6
11. CHASSIS EARTHING The chassis earthing lug should be connected to an earthing point, which will vary
depending on where the power inverter is installed. In a vehicle, connect the chassis ground lug to the chassis of the vehicle. In a boat, connect to the boat's grounding systems. In a fixed location, connect to earth.
12. CAUTION In case of trouble with the AC output, e.g. short-circuit, overload, etc… the
protection circuit will automatically cut off the output. In such cases : (A) switch off the power at once (B) disconnect all units (C) check the connected devices (D) use the units again as soon as any problems
concerning the connected devices have been solved
When in use for a prolonged period of time, the AC output may suddenly be cut off although the battery voltage is still very strong. This may be caused by excessive temperatures. If this happens, please proceed as follo ws : (A) Switch off the inverter at once (B) Disconnect some of the appl iances or wait until the inverter cools off (C) Switch the inverter back on
Always keep the inverter in an environment which is : (A) Well-ventilated (B) Not exposed to direct sunlight or any other heat source (C) Inaccessible to child ren (D) Safe from water/moisture, oil or grease (E) Safe from any flammable substance
If the inverter is connected in the wrong way, this will void the warranty.
PI600M & PI60024 v2 GB 5
Page 7
13. MAINTENANCE Very little maintenance is required to keep your inverter operating smoothly.
Clean the exterior of the device periodically using a damp cloth in order to prevent the accumulation of dust and dirt. Tighten the scre ws on the DC input terminals whenever you are cleaning the device.
14. SPECIFICATIONS
DC input voltage : 12V / 24V, refer to model label !!!
AC output voltage : 230V
Output frequency : 50Hz
Continuous output power : 600W
Output waveform : modified sinewave
No load current : < 1A
Battery low alarm & shutdown : 10.5 ± 0.5VDC for a 12V input
21
±
1VDC for a 24V input
Input current at 100% load : 64A for a 12V inverter, 32A for a 24V inverter
Output curre nt at 100% loa d : 2.6A
Overheating protection : 55 ± 5°C
Dimensions : 205 x 73 x 290mm
Weight : 2.1kg
15. NOTE All specifications are typical at nominal input voltage, 50% load and 25°C unless
otherwise noted. All specifications are subjec t to change without prior notice.
WARNING : DO NOT DISASSEMBLE THIS UNIT AS DOING SO MAY CAUSE HAZARDOUS VOLTAGES !! RETURN THIS UNIT TO THE DEALER IN CASE OF TROUBLE !!
IMPORTANT : DO NOT CONNECT ANY INDUCTIVE LOADS WITH THIS
DEVICE !
PI600M & PI60024 v2 GB 6
Loading...